Back to Authors

Kaufman, Kenton R.

https://orcid.org/0000-0002-7311-3781

Mayo Clinic

Mayo Clinic

Citations 96

Design and Development of a Powered Myoelectric Elbow Orthosis for Neuromuscular Injuries
Vignola, Claudio, Bhat, Sandesh G. , Hollander, Kevin W., Kane, Paul H., Miller, Emily J. , Martin, W. Brandon , Shin, Alexander Y. , Sugar, Thomas G. , Kane, Paul, Miller, Emily , Kaufman, Kenton R , Shin, Alexander Y , Bhat, Sandesh G , Kaufman, Kenton R.

Military Medicine | April 3, 2024 | Volume: 189 | Issue: Supplement_3 | Pages: 585-591

10.1093/milmed/usae196 Get It

ABSTRACT Introduction Recovering from neuromuscular injuries or conditions can be a challenging journey that involves complex surgeries and extensive physical rehabilitation. During this process, individuals often rely on orthotic devices to support and enable movement of the affected limb. However, users have criticized current commercially available powered orthotic devices for their bulky and heavy design. To address these limitations, we developed a novel powered myoelectric elbow orthosis. Materials and Methods The orthosis incorporates 3 mechanisms: a solenoid brake, a Bowden cable-powered constant torque elbow mechanism, and an extension limiter. The device controller and battery are in a backpack to reduce the weight on the affected arm. We performed extensive calculations and testing to ensure that the orthosis could withstand at least 15 Nm of elbow torque. We developed a custom software effectively control the orthosis, enhancing its usability and functionality. A certified orthotist fitted a subject who had undergone a gracilis free functioning muscle transfer surgery with the device. We studied the subject under Mayo clinic IRB no. 20-006849 and obtained objective measurements to assess the orthosis’s impact on upper extremity functionality during daily activities. Results The results are promising since the orthosis significantly improved elbow flexion range of motion by 40° and reduced compensatory movements at the shoulder (humerothoracic joint) by 50°. Additionally, the subject was able to perform tasks which were not possible before, such as carrying a basket with weights, highlighting the enhanced functionality provided by the orthosis. Conclusion In brief, by addressing the limitations of existing devices, this novel powered myoelectric elbow orthosis offers individuals with neuromuscular injuries/conditions improved quality of life. Further research will expand the patient population and control mechanisms.
McArdle’s sign: a specific sign of multiple sclerosis (P1.087)
Weinshenker, Brian, Hu, Wei , Delgado, Adriana, Mandrekar, Jayawant, Berglund, Lawrence J., Savoldi, Filippo , Nasr, Zahra , Schilaty, Nathan D. , Kaufman, Kenton R.

Neurology | December 7, 2023 | Volume: 90 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.90.15_supplement.p1.087 Get It

Neuroimaging Correlates of Gait Abnormalities in Progressive Supranuclear Palsy (P1-1.Virtual)
Sintini, Irene , Loushin, Stacy R. , Christopher, Schwarz, Lowe, Val J. , Josephs, Keith A. , Whitwell, Jennifer L. , Ali, Farwa , Kaufman, Kenton R. , Botha, Hugo , Senjem, Matthew L. , Reid, Robert I. , Jack, Clifford R.

Neurology | December 6, 2023 | Volume: 98 | Issue: 18_supplement | Pages: No page available

10.1212/wnl.98.18_supplement.1364 Get It

Wrist Motion Assessment in Tennis Players using Three-Dimensional Motion Capture and Dynamic Electromyography
Israel, Jacqueline S. , Loushin, Stacy R. , Tetzloff, Sabine U. , Ellenbecker, Todd S. , Kakar, Sanjeev , Kaufman, Kenton R , Kakar, Sanjeev , Kaufman, Kenton R.

Journal of Wrist Surgery | December 1, 2023 | Volume: 13 | Issue: 03 | Pages: 264-271

10.1055/s-0043-1777024 Get It

Abstract Background Tennis players often present with ulnar-sided wrist pain, which may reflect repetitive stress and/or faulty mechanics. There is a role for investigating the biomechanics of tennis strokes and how they may relate to wrist pathology. The purpose of this study was to investigate whether three-dimensional motion capture technology and dynamic electromyography (EMG), when used to study groundstrokes in elite junior tennis players, reveals patterns of upper extremity motion that may correlate with the development of clinically relevant pathology. Case Description Three-dimensional kinematic and EMG data were collected from two United States Tennis Association-ranked adolescent tennis players during groundstrokes. There were several observed differences in the two players' degree and timing of pronation/supination, ulnar/radial deviation, and flexion/extension during their strokes. Clinical Significance Advanced motion capture technology facilitates a nuanced understanding of complex movements involved in groundstroke production. This methodology may be useful for identifying athletes who are at risk for injury and guiding rehabilitation for players experiencing pain. Level of Evidence IV
Experimental Determination Of Human Skeletal Muscle Specific Tension
Persad, Lomas S. , Litchy, Bill, Lieber, Richard L. , Binder‐Markey, Benjamin I. , Shin, Alexander Y. , Kaufman, Kenton R.

Medicine & Science in Sports & Exercise | September 26, 2023 | Volume: 55 | Issue: 9S | Pages: 214-214

10.1249/01.mss.0000981700.54222.72 Get It

Poster 204: Changes in Elbow Stress and Ball Velocity During Reduced Effort Pitching: A Marker-Based Motion Capture Analysis
Fiegen, Anthony P. , Nezlek, Stuart, Loushin, Stacy R. , Christoffer, Daniel J., Verhoeven, Martijn, Kaufman, Kenton R. , Camp, Christopher L.

Orthopaedic Journal of Sports Medicine | July 31, 2023 | Volume: 11 | Issue: 7_suppl3 | Pages: No page available

10.1177/2325967123s00189 Get It

Objectives: Baseball pitchers often participate in throwing programs that involve throwing at reduced effort levels to gradually increase the amount of stress experienced across the elbow. It is currently unknown how reduced effort pitching compares to maximum effort with respect to elbow stress and ball velocity. The purpose of this study is to determine whether elbow stress and ball velocity correlate with reduced effort pitching, whether elbow stress and ball velocity decrease proportionally while throwing at a reduced effort, and to assess intrathrower reliability. Methods: Ten healthy male high school baseball pitchers threw 5 pitches from a regulation pitching mound at 3 effort levels: maximum effort, 75% effort, and 50% effort. Elbow stress, specifically elbow varus torque, was calculated for all pitches using a marker-based 3D motion capture system. Ball velocity was measured using a Doppler radar gun. Intrathrower variability was calculated for each effort level. Results: Elbow stress and ball velocity decreased with reduced effort throws (p<0.001 and p=0.003, respectively). However, the reductions in elbow stress and ball velocity were not proportional. At 75% effort throws, elbow stress decreased only 19% and ball velocity decreased only 10%. At 50% effort throws, elbow stress decreased only 25% and ball velocity decreased only 15%. Intrathrower reliability was excellent for elbow stress and ball velocity, with intraclass correlation coefficients all greater than or equal to 0.80. Conclusions: Pitching at a reduced effort level resulted in decreased elbow stress and ball velocity. However, for every 25% reduction in perceived effort, elbow stress decreased by a mean of 13% and ball velocity decreased 8%. When baseball pitchers attempt to throw at a reduced effort of maximum, throwing metrics do not decrease proportionately. While pitching at a reduced effort of maximum decreases elbow stress and ball velocity, the decrease is not proportional, subjecting the elbow to more stress than intended. This has significant clinical importance to pitchers, coaches, and medical professionals in the setting of injury prevention and return to sport. [Table: see text]
Direct measurement of human skeletal muscle specific tension and fiber length
Persad, Lomas S. , Lieber, Richard L. , Binder‐Markey, Benjamin I. , Shin, Alexander Y. , Kaufman, Kenton R.

Physiology | May 29, 2023 | Volume: 38 | Issue: S1 | Pages: No page available

10.1152/physiol.2023.38.s1.5723751 Get It

Skeletal muscle’s isometric contractile properties are one of the classic structure-function relationships in all of physiology allowing for extrapolation of single fiber mechanical properties to whole muscle properties based on the muscle’s optimal fiber length and physiological cross-sectional area (PCSA). However, this relationship has only been validated in small animals and then extrapolated to human muscles which are much larger in terms of length and PCSA. We leveraged a unique surgical technique in which an intact, living, human gracilis muscle is transferred from the thigh to the arm, restoring elbow flexion after brachial plexus injury. During this surgery we directly measured subject specific gracilis muscle force-length relationship in situ and properties ex vivo. We hypothesized that the human gracilis would have a functional fiber length of about 23 cm, based on the anatomical literature, and a specific tension of 225 kPa, based on the physiological literature. Data are provided as mean±standard deviation of the mean. Twelve subjects (7 males, average age 54±12 years). In situ passive and active tension were directly measured using a buckle force transducer (BFT) placed on the distal gracilis tendon. Passive tension was measured in each of four joint configurations (JC) prior to muscle stimulation, and, to produce active tension, the anterior branch of the obturator nerve was stimulated. The muscle was progressively lengthened by extending the knee and abducting the hip. Since we could not measure optimal fiber length directly in our subjects during isometric testing we used a functional surrogate for optimal fiber length, the full-width at half-maximum (FWHM) defined from their force vs. length relationship. The FWHM is the width of the active force vs. muscle length curve at half the maximum force. A linear relationship between FWHM and optimal fiber length has been established across several mammalian species and muscles. Thus, to calculate FWHM, we fit each patient’s calculated fully active force vs. muscle length data to a quadratic curve and then calculated width at half the calculated maximum force from the equation. Optimal fiber length was then calculated from the previously established linear relationship between FWHM and optimal fiber length. Each subject’s PCSA was calculated from their muscle volume and optimal fiber length.From these experimental data we established a human muscle fiber-specific tension of 171±84 kPa (n=12). We also determined the average gracilis optimal fiber length was 12.9±3.3 cm (n=12). Surprisingly, these fiber lengths were about half of the previously reported optimal fascicle lengths of 23 cm. Thus, the long gracilis muscle appears to be composed of relatively short fibers acting in parallel that may not have been appreciated based on traditional anatomical methods. We thus suggest that the value of 171 kPa be considered the best current estimate of human muscle specific tension. This work was supported the Department of Veterans Affairs grant 1 I01 RX002462 and, in part, by Research Career Scientist Award Number IK6 RX003351 from the United States (U.S.) Department of Veterans Affairs Rehabilitation R&D (Rehab RD) Service. Pilot projects leading to this protocol were supported by the Shirley Ryan AbilityLab Catalyst Grant Program, National Science Foundation Graduate Research Fellowship under Grant No. 1255833 and the Mayo Clinic Graduate School. This is the full abstract presented at the American Physiology Summit 2023 meeting and is only available in HTML format. There are no additional versions or additional content available for this abstract. Physiology was not involved in the peer review process.
Are 4D Motion Sensors Valid and Reliable for Studying Baseball Pitching?
Loushin, Stacy R. , Verhoeven, Martijn, Christoffer, Daniel J., Camp, Christopher L. , Kaufman, Kenton R.

The American Journal of Sports Medicine | April 17, 2023 | Volume: 51 | Issue: 6 | Pages: 1608-1614

10.1177/03635465231166423 Get It

Background: Baseball pitching injuries are on the rise. Inertial measurement units (IMUs) provide immediate feedback to players and coaches, allowing for collection outside of the traditional laboratory setting with real-world application. The 4D Motion system provides kinematics throughout the pitching motion and may be beneficial for individualized programs in the throwing athlete. A systematic analysis of these sensors has not been completed. Purpose: To evaluate the validity of the 4D Motion IMU system for analyzing the baseball pitching motion compared with marker-based motion capture, and evaluate the internal reliability and consistency of the device. Study Design: Controlled laboratory study. Methods: Ten high school pitchers participated in this study (10 male; 9 right-hand dominant; mean age, 16.6 ± 1.3 years; mean body mass index, 24.1 ± 3.9). Participants were simultaneously outfitted with six 4D Motion IMU sensors and retroreflective markers. The pitchers threw fastballs at maximum effort off a mound at the standard height and distance. A comparison was made between the IMUs and corresponding motion capture values for shoulder external rotation, elbow flexion, chest extension, pelvis and chest rotation velocity, and rotation acceleration. Results: Significant differences were found for 5 of 7 metrics analyzed. The IMU overreported most metrics, except for elbow flexion and pelvis rotation angular acceleration, where both positive and negative errors were observed. The root mean square error and percentage errors indicated smaller discrepancies for chest extension (4°± 5°) and pelvis (38 ± 19 deg/s) and chest (96 ± 42 deg/s) rotation velocity, with elbow flexion having the largest variance (21°± 9°). Conclusion: The values of the 4D Motion IMU system should not be considered equivalent when compared with marker-based motion capture studies. The system lacked internal consistency and reliability, with angular velocities being the most consistent. Caution should be used when using the metrics provided by an IMU-based system for individualized monitoring. Clinical Relevance: If found valid and reliable, IMUs could be used for longitudinal workload monitoring, individualized throwing and rehabilitation programs, and ultimately injury prevention. This study demonstrates that the data obtained from a 4D Motion system using Gen 3 sensors are not equivalent to the data obtained from a marker-based motion capture system.
Objective assessment of patients with idiopathic normal pressure hydrocephalus following ventriculoperitoneal shunt placement using activity-monitoring data: pilot study
Jusué-Torres, Ignacio , Pennington, Zach , Ali, Farwa, Graff‐Radford, Neill R. , Cutsforth‐Gregory, Jeremy K. , Graff-Radford, Jonathan, Elder, Benjamin D. , Pennington, Zach , Jusue-Torres, Ignacio , Brown, Desmond , Cogswell, Petrice M. , Ali, Farwa , Jones, David , Graff‐Radford, Jonathan , Kaufman, Kenton R.

Neurosurgical Focus | April 1, 2023 | Volume: 54 | Issue: 4 | Pages: E6

10.3171/2023.1.focus22640 Get It

OBJECTIVE Idiopathic normal pressure hydrocephalus (iNPH) results in significant morbidity in the elderly with symptoms of dementia, gait instability, and urinary incontinence. In well-selected patients, ventriculoperitoneal shunt (VPS) placement often results in clinical improvement. Most postshunt assessments of patients rely on subjective scales. The goal of this study was to assess the utility of remote activity monitoring to provide objective evidence of gait improvement following VPS placement for iNPH. METHODS Patients with iNPH were prospectively enrolled and fitted with 5 activity monitors (on the hip and bilateral thighs and ankles) that they wore for 4 days preoperatively within 30 days of surgery and for 4 days within 30 days postoperatively. Monitors collected continuous data for number of steps, cadence, body position (upright, prone, supine, and lateral decubitus), gait entropy, and the proportion of each day spent active or static. Data were retrieved from the devices and a comparison of pre- and postoperative movement assessment was performed. The gait data were also correlated with formal clinical gait assessments before and after lumbar puncture and with motion analysis laboratory testing at baseline and 1 month and 1 year after VPS placement. RESULTS Twenty patients fulfilled the inclusion and exclusion criteria (median age 76 years). The baseline median number of daily steps was 1929, the median percentage of the day spent inactive was 70%, the median percentage of the day with a static posture was 95%, the median gait velocity was 0.49 m/sec, and the median number of steps required to turn was 8. There was objective improvement in median entropy from pre- to postoperatively, increasing from 0.6 to 0.8 (p = 0.002). There were no statistically significant differences for any of the remaining variables measured by the activity monitors when comparing the preoperative to the 1-month postoperative time point. All variables from motion analysis testing showed statistically significant differences or a trend toward significance at 1 year after VPS placement. Among the significantly correlated variables at baseline, cadence was inversely correlated with percentage of gait cycle spent in the support phase (contact with ground vs swing phase). CONCLUSIONS This pilot study suggests that activity monitoring provides an early objective measure of improvement in gait entropy after VPS placement among patients with iNPH, although a more significant improvement was noted on the detailed clinical gait assessments. Further long-term studies are needed to determine the utility of remote monitoring for assessing gait improvement following VPS placement.
Direct intraoperative measurement of isometric contractile properties in living human muscle
Binder‐Markey, Benjamin I. , Persad, Lomas S. , Litchy, William J. , Lieber, Richard L. , Lieber, Richard L , Shin, Alexander Y. , Kaufman, Kenton R.

The Journal of Physiology | March 11, 2023 | Volume: 601 | Issue: 10 | Pages: 1817-1830

10.1113/jp284092 Get It

AbstractSkeletal muscle's isometric contractile properties are one of the classic structure–function relationships in all of biology allowing for extrapolation of single fibre mechanical properties to whole muscle properties based on the muscle's optimal fibre length and physiological cross‐sectional area (PCSA). However, this relationship has only been validated in small animals and then extrapolated to human muscles, which are much larger in terms of length and PCSA. The present study aimed to measure directly the in situ properties and function of the human gracilis muscle to validate this relationship. We leveraged a unique surgical technique in which a human gracilis muscle is transferred from the thigh to the arm, restoring elbow flexion after brachial plexus injury. During this surgery, we directly measured subject specific gracilis muscle force–length relationship in situ and properties ex vivo. Each subject's optimal fibre length was calculated from their muscle's length‐tension properties. Each subject's PCSA was calculated from their muscle volume and optimal fibre length. From these experimental data, we established a human muscle fibre‐specific tension of 171 kPa. We also determined that average gracilis optimal fibre length is 12.9 cm. Using this subject‐specific fibre length, we observed an excellent fit between experimental and theorical active length‐tension curves. However, these fibre lengths were about half of the previously reported optimal fascicle lengths of 23 cm. Thus, the long gracilis muscle appears to be composed of relatively short fibres acting in parallel that may not have been appreciated based on traditional anatomical methods. imageKey points Skeletal muscle's isometric contractile properties represent one of the classic structure–function relationships in all of biology and allow scaling single fibre mechanical properties to whole muscle properties based on the muscle's architecture. This physiological relationship has only been validated in small animals but is often extrapolated to human muscles, which are orders of magnitude larger. We leverage a unique surgical technique in which a human gracilis muscle is transplanted from the thigh to the arm to restore elbow flexion after brachial plexus injury, aiming to directly measure muscles properties in situ and test directly the architectural scaling predictions. Using these direct measurements, we establish human muscle fibre‐specific tension of ∼170 kPa. Furthermore, we show that the gracilis muscle actually functions as a muscle with relatively short fibres acting in parallel vs. long fibres as previously assumed based on traditional anatomical models.