Back to Authors

Kaufman, Kenton R.

https://orcid.org/0000-0002-7311-3781

Mayo Clinic

Mayo Clinic

Citations 96

Evaluating longitudinal changes of gait parameters following shunt placement in patients with idiopathic normal pressure hydrocephalus
Pennington, Zach , Potes, Maria Astudillo , Hallak, Hana , Rezaei, Asghar , Jusué-Torres, Ignacio , Graff-Radford, Jonathan, Cutsforth‐Gregory, Jeremy K. , Ali, Farwa, Elder, Benjamin D. , Pennington, Zach , Jusue-Torres, Ignacio , Kumar, Rahul , Hamouda, Abdelrahman M. , Shafi, Mahnoor , Bhat, Sandesh G. , Graff‐Radford, Jonathan , Jones, David , Botha, Hugo , Ali, Farwa , Cogswell, Petrice M. , Kaufman, Kenton R.

Journal of Neurosurgery | June 27, 2025 | Volume: 143 | Issue: 5 | Pages: 1254-1261

10.3171/2025.3.jns241416 Get It

OBJECTIVE Idiopathic normal pressure hydrocephalus (iNPH) is characterized by gait deterioration, cognitive disturbances, and urinary incontinence. Gait deficits pose safety hazards due to frequent falls, yet objective investigations of gait improvement following ventriculoperitoneal shunt (VPS) placement are limited. Therefore, the aim of this study was to assess objective improvement in gait parameters for patients with iNPH after VPS placement. METHODS All patients treated with a VPS for iNPH by the senior author at a single tertiary care center from December 2017 to January 2023 were retrospectively reviewed. Patients who underwent detailed motion analysis testing before surgery with > 1 follow-up assessment were included. Analyzed parameters included gait velocity, gait cadence, stride length, stride width, gait stability ratio, total support, and single support. Time-dependent linear mixed-effects models and generalized additive mixed-effects models (GAMMs) were used to model short-term and longitudinal gait parameter changes, respectively. RESULTS A total of 212 patients (137 male, median age was 75.2 years) who underwent VPS placement for iNPH were included, with a total of 747 gait analyses performed at a median last-gait analysis follow-up duration of 12.0 months. Statistically significant changes in all gait parameter values were seen between the preoperative time point and first postoperative follow-up (within 3 months) time point (paired Wilcoxon p < 0.001), with a statistically significant majority of patients experiencing improvement (binominal p < 0.0001). Longitudinal analyses using a GAMM showed increased gait velocity, single support, and stride length, with decreased stability ratio, step width, and total support at early time points, while a plateau was achieved around 6 months. CONCLUSIONS A detailed gait analysis demonstrated significant improvements in objective ambulation metrics, particularly in the gait velocity, stride length, and gait stability ratio, following VPS placement in patients with iNPH. Most patients maintained marked improvement from baseline to the last follow-up assessment, although a plateau of the benefit was experienced over longer follow-up.
The Effect of an Osseointegration Implant on Gait Kinematics for Extremely Short Transfemoral Amputees
Wilke, Benjamin K. , Spaulding, Aaron , Patel, Janki H, Pompilio, Steve, Hemmen, Geoff , Weiss, Howard D., Kaufman, Kenton R , Spaulding, Aaron , Patel, Janki H , Pompilio, Steve , Hemmen, Geoff , Weiss, Howard , Wilke, B K , Kaufman, Kenton R.

JBJS Case Connector | June 12, 2025 | Volume: 15 | Issue: 2 | Pages: No page available

10.2106/jbjs.cc.25.00020 Get It

Case: We present a 55-year-old woman with a very short transfemoral amputation who underwent osseointegration. We compared gait analyses before and following osseointegration, demonstrating improvements in kinematics. At follow-up, the patient wore the prosthetic for 16 hours and averaged 10,000 steps daily. She achieved her goal of walking the beach with her prosthetic limb and often traveled without an assistive device. Conclusion: This case study of a patient with a very short transfemoral amputation demonstrated continued improvements in gait and significantly increased prosthetic use over time.
In vivo human gracilis muscle active force‐length relationship is explained by the sliding filament theory
Wang, Zheng , Persad, Lomas S. , Binder‐Markey, Benjamin I. , Hoffman, E. Matthew , Litchy, William J. , Lieber, Richard L. , Hoffman, Ernest Matthew , Lieber, Richard L , Shin, Alexander Y. , Kaufman, Kenton R.

The Journal of Physiology | May 11, 2025 | Volume: 603 | Issue: 10 | Pages: 3049-3059

10.1113/jp288322 Get It

AbstractThe sliding filament theory explains skeletal muscle fibre force change as a function of length based on the overlap of actin and myosin filaments. Although this length‐tension (LT) relationship has been well investigated in animal models, it is not known whether this microscopic sarcomere LT property can be scaled up five orders of magnitude to explain the LT behaviour of a long human muscle such as the gracilis. The goal of this study is to validate the sarcomere LT curve in humans based on human filament length combined with in vivo experimental data. Intraoperative measurements of maximal tetanic force and muscle‐tendon unit length at four different joint configurations (JC) were obtained from 19 patients undergoing free functioning muscle transfer surgery. With physiologically measured fibre length and estimated sarcomere shortening resulting from tendon compliance, we show that 79.7% variance in isometric force data is explained by a simple human sarcomere LT model. This study demonstrates that the human whole muscle LT relationship can be modelled by the sliding filament theory given patient‐specific fibre length, filament length, tendon compliance and sarcomere shortening. imageKey points Whole human gracilis muscle isometric length‐tension relationships were measured in the operating room. Grouped whole muscle raw length‐tension curves showed no obvious form. The width of each experimental length‐tension curve was highly variable across subjects and used to predict fibre length (serial sarcomere number). After whole muscle length‐tension curves were normalized to each patient's serial sarcomere number, the whole human muscle length‐tension curve was well predicted by the sliding filament theory.
Reactive Balance in Adolescent Idiopathic Scoliosis: A Prospective Motion Analysis Study
Paradkar, Ria, Regan, Christina , Bernhardt, Kathie A., Kaufman, Kenton R. , Milbrandt, Todd A. , Larson, A. Noelle , Bernhardt, Kathie, Larson, A Noelle , Kaufman, Kenton R , Paradkar, Ria

Journal of Clinical Medicine | March 4, 2025 | Volume: 14 | Issue: 5 | Pages: 1715

10.3390/jcm14051715 Get It

Background/Objectives: Traditional fusion leads to a loss of spine mobility across the fused vertebrae. Vertebral body tethering (VBT) was developed with the goal of increasing flexibility and maintaining some spinal mobility. However, it is not known if the additional mobility leads to significant functional improvement. This prospective motion analysis study evaluates functional outcomes, specifically gait stability, in pre-operative, post-fusion, and post-VBT patients by using postural perturbations on a treadmill. Methods: Overall, 79 subjects underwent a computer-controlled treadmill study with postural perturbations, which simulated trips and slips. The subjects were harnessed for safety. Overall, 21 subjects were healthy controls, 18 patients were at least one-year post-VBT, 15 patients were at least one-year post-fusion, and 25 were pre-operative scoliosis patients. Subject weight, height, and treadmill acceleration were recorded and used to determine anteroposterior single (ASSTs, PSSTs) and multiple (AMSTs, PMSTs) stepping thresholds to describe the maximum torque a patient could withstand before failing to recover from the simulated trip. Independent t-tests were run to compare groups under the advice of a master statistician with expertise in orthopedic surgery. Results: Pre-operative scoliosis patients had lower PSSTs than healthy controls (uncorrected p = 0.036). No significant differences were observed between pre-operative and post-operative groups for both fusion and VBT. There was no significant difference in ASST, AMST, or PMST between any of the groups. Conclusions: The lower PSST in pre-operative scoliosis patients compared to healthy controls may reflect impaired reactive balance and potentially increased fall risk. Interestingly, there was no significant difference in reactive balance measures between pre-operative and post-operative scoliosis patients or between post-fusion and post-VBT patients.
The potential of preoperative dynamic electromyography in guiding targeted surgical procedures for elbow spasticity
Wang, Zheng , Lunasin, Ray M. , Hoffman, E. Matthew , Rhee, Peter C. , Hoffman, Ernest M., Kaufman, Kenton R , Lieber, Richard L. , Kaufman, Kenton R.

Journal of Hand Surgery (European Volume) | February 28, 2025 | Volume: 50 | Issue: 11 | Pages: 1534-1537

10.1177/17531934251323078 Get It

Six patients treated by hyperselective neurectomy were assessed using preoperative dynamic electromyography and intraoperative force measurements. Patients with lower preoperative biceps dynamic electromyography activation had significantly reduced force production at operation, suggesting that these findings could guide and improve procedure selection. Level of evidence: IV
Effects of Age and Muscle Activation on Three-Dimensional Spine Kinematics and Asymmetry in Elderly Adults
Rezaei, Asghar , Cheng, Chih-Hsiu , Pignolo, Robert J. , Lu, Lichun , Kaufman, Kenton R. , Kaufman, Kenton R

Journal of Clinical Medicine | February 27, 2025 | Volume: 14 | Issue: 5 | Pages: 1610

10.3390/jcm14051610 Get It

Background/Objectives: Limited spinal range of motion (ROM) is linked to low back disorders, emphasizing the need to maintain mobility in the elderly. This study measured maximum spinal ROM, asymmetrical patterns, and the effects of age and muscle activation on spinal mobility. Methods: Forty healthy participants aged 50 and older were recruited. An optical motion capture system recorded three-dimensional coordinates of reflective markers placed on spinal landmarks. Asymmetry was analyzed in sidebending and axial rotation. Electromyography (EMG) data were collected bilaterally from paraspinal muscles at L3 during flexion, extension, sidebending, and axial rotation. Results: Trunk ROM averaged 111° in flexion, 38° in extension, 46° in sidebending, and 87° in axial rotation. Kinematic asymmetry was observed in sidebending and axial rotation. ROM decreased with age in flexion motion (p ≤ 0.04). EMG activity was significantly correlated with ROM data for all combined motions (p = 0.0002). The strongest EMG signal was recorded during flexion, whereas the weakest signal was observed during extension. EMG activity also correlated with kinematic asymmetry (p ≤ 0.03). Conclusions: Age and muscle activation significantly influence spinal ROM in the elderly. Lumbar kinematic asymmetry can be partially attributed to paraspinal muscle activation, underscoring the importance of analyzing asymmetrical motions in conjunction with EMG activity.
Enhanced Functionality Using a Powered Upper Extremity Exoskeleton in Patients With Brachial Plexus Injuries
Bhat, Sandesh G. , Miller, Emily J. , Kane, Paul H., Hollander, Kevin W., Vignola, Claudio, Sugar, Thomas G. , Bhat, Sandesh G , Shin, Alexander Y. , Kaufman, Kenton R.

IEEE Transactions on Neural Systems and Rehabilitation Engineering | February 13, 2025 | Volume: 33 | Issue: No issue available | Pages: 780-786

10.1109/tnsre.2025.3538175 Get It

Specific tension of human muscle in vivo: a systematic review
Persad, Lomas S. , Wang, Zheng , Pino, Paula A. , Binder‐Markey, Benjamin I. , Lieber, Richard L. , Lieber, Richard L , Kaufman, Kenton R.

Journal of Applied Physiology | August 22, 2024 | Volume: 137 | Issue: 4 | Pages: 945-962

10.1152/japplphysiol.00296.2024 Get It

The intrinsic force production capability of human muscle can be expressed as “Specific Tension,” or, the maximum force generated per cross-sectional area of muscle fibers. This value can be used to determine, for example, whether muscle quality changes during exercise, atrophy, disease, or hypertrophy. A value of 22.5 N/cm 2 for mammalian muscle has generally become accepted based on detailed studies of small mammals. Determining the specific tension of human muscle is much more challenging as almost all determinations are indirect. Calculation of human muscle specific tension requires an understanding of that muscle’s contribution to joint torque, its activation magnitude, tendon compliance, and joint moment arm. Determining any of these parameters is technically challenging in humans and thus, it is no surprise that human specific tension values reported vary from 2 to 73 N/cm 2 . In this systematic review, we screened 1,506 published papers and identified the 30 studies published between 1983 and 2023 that used appropriate methods and which reported 96 human specific tension values. We weighted each parameter based on whether it was directly measured, estimated, or calculated based on the literature, with decreasing weighting used, the more indirect the methods. Based on this exhaustive review of the relevant human literature, we suggest that the most accurate value that should be used for human muscle specific tension is 26.8 N/cm 2 .
Validation of Pelvis and Trunk Range of Motion as Assessed Using Inertial Measurement Units
Ali, Farwa , Hogen, Cecilia A., Miller, Emily J. , Kaufman, Kenton R.

Bioengineering | June 28, 2024 | Volume: 11 | Issue: 7 | Pages: 659

10.3390/bioengineering11070659 Get It

Trunk and pelvis range of motion (ROM) is essential to perform activities of daily living. The ROM may become limited with aging or with neuromusculoskeletal disorders. Inertial measurement units (IMU) with out-of-the box software solutions are increasingly being used to assess motion. We hypothesize that the accuracy (validity) and reliability (consistency) of the trunk and pelvis ROM during steady-state gait in normal individuals as measured using the Opal APDM 6 sensor IMU system and calculated using Mobility Lab version 4 software will be comparable to a gold-standard optoelectric motion capture system. Thirteen healthy young adults participated in the study. Trunk ROM, measured using the IMU was within 5–7 degrees of the motion capture system for all three planes and within 10 degrees for pelvis ROM. We also used a triad of markers mounted on the sternum and sacrum IMU for a head-to-head comparison of trunk and pelvis ROM. The IMU measurements were within 5–10 degrees of the triad. A greater variability of ROM measurements was seen for the pelvis in the transverse plane. IMUs and their custom software provide a valid and reliable measurement for trunk and pelvis ROM in normal individuals, and important considerations for future applications are discussed.
Mechanical Method for Rapid Determination of Step Count Sensor Settings
Lundell, Sydney , Kaufman, Kenton R.

Bioengineering | May 27, 2024 | Volume: 11 | Issue: 6 | Pages: 547

10.3390/bioengineering11060547 Get It

With the increased push for personalized medicine, researchers and clinicians have begun exploring the use of wearable sensors to track patient activity. These sensors typically prioritize device life over robust onboard analysis, which results in lower accuracies in step count, particularly at lower cadences. To optimize the accuracy of activity-monitoring devices, particularly at slower walking speeds, proven methods must be established to identify suitable settings in a controlled and repeatable manner prior to human validation trials. Currently, there are no methods for optimizing these low-power wearable sensor settings prior to human validation, which requires manual counting for in-laboratory participants and is limited by time and the cadences that can be tested. This article proposes a novel method for determining sensor step counting accuracy prior to human validation trials by using a mechanical camshaft actuator that produces continuous steps. Sensor error was identified across a representative subspace of possible sensor setting combinations at cadences ranging from 30 steps/min to 110 steps/min. These true errors were then used to train a multivariate polynomial regression to model errors across all possible setting combinations and cadences. The resulting model predicted errors with an R2 of 0.8 and root-mean-square error (RMSE) of 0.044 across all setting combinations. An optimization algorithm was then used to determine the combinations of settings that produced the lowest RMSE and median error for three ranges of cadence that represent disabled low-mobility ambulators, disabled high-mobility ambulators, and healthy ambulators (30–60, 20–90, and 30–110 steps/min, respectively). The model identified six setting combinations for each range of interest that achieved a ±10% error in cadence prior to human validation. The anticipated range of errors from the optimized settings at lower walking speeds are lower than the reported errors of wearable sensors (±30%), suggesting that pre-human-validation optimization of sensors may decrease errors at lower cadences. This method provides a novel and efficient approach to optimizing the accuracy of wearable activity monitors prior to human validation trials.