Abstract Background Machine perfusion represents the most significant breakthrough in liver transplantation (LT) since the discovery of cyclosporin. Yet, the optimal perfusion strategy remains unsettled. Randomized trials demonstrate that hypothermic oxygenated perfusion (HOPE) improves graft survival and function and reduces ischemic cholangiopathy, whereas normothermic machine perfusion (NMP) decreases post-transplant injury. Real-world comparisons are lacking and challenging due to heterogeneity in donor-recipient risk profiles and regional differences. Aims To compare real-world outcomes of HOPE and NMP in LT. Methods We analyzed consecutive NMP-preserved LTs from seven North American centers between 2021 and 2024. We compared NMP to the European HOPE-REAL cohort, comprising HOPE-treated LTs from 22 centers between 2012 and 2021. Analyses were stratifyied by graft type and risk category and adjusted for donor age, donor risk index, and balance of risk score using entropy balancing. Results A total of 470 NMP and 1202 HOPE-treated grafts were analyzed, revealing major differences in risk profiles (Figure 1). In NMP, death-censored graft survivals at 1, 2, and 3 years were >95% in donation after brain death (DBD) and >94% in donation after circulatory death (DCD) grafts. Comparable outcomes were observed in the HOPE cohort with >93%, in DBD, and >87% in DCD after up to 3 years, despite significantly higher donor age and longer functional warm ischemia in the HOPE DCD cohort (Figure 2). After risk adjustment, death-censored graft survival remained similar between both modalities (Table 1). Non-anastomotic biliary stricture rates after DCD-LT were comparable (8.5% vs. 12.4%), independent of whether continuous or end-ischemic NMP was performed. Conclusion This first transatlantic real-world report demonstrates excellent outcomes with both NMP and HOPE despite higher graft risk in Europe. Machine perfusion is the new standard of care in LT, while further understanding is needed regarding the distinct benefits of each modality across risk profiles.Figure 1.Graft risk in NMP and HOPE stratified by graft type. Benchmark case was defined as primary transplant with MELD <20 and BAR score <9, extended criteria as either BMI >30kg/m2, donor age >65 years, CIT >12h. DCD grafts were categorized as definedFor image description, please refer to the figure legend and surrounding text. Figure 2.Death-censored graft survival in liver transplantation following NMP and HOPE stratified by graft type. Abbreviations: NMP (Normothermic Machine Perfusion), HOPE (Hypothermic Oxygenated Perfusion), DBD (Donation after Brain Death), DCD (Donation after circulatory death)For image description, please refer to the figure legend and surrounding text. Table 1.Risk-adjusted comparison of death-censored graft survival between NMP and HOPE.For image description, please refer to the figure legend and surrounding text.
Objective: To establish international benchmark values for relevant outcome parameters in robotic Whipple. Summary Background Data: For safe adoption of surgical innovation, robust quality control is essential. Benchmarking is a validated tool for assessing surgical performance. Recent international consensus identified establishing benchmark values for robotic Whipple as top priority. Methods: We analyzed consecutive patients undergoing robotic Whipple between 2020-2023 with a minimum one-year follow-up. Reference centers were required to perform ≥15 cases/year, be scientifically active in the field, and maintain a prospective database. Benchmark criteria included benign or resectable malignant disease without neoadjuvant therapy, arterial resection, major co-morbidities, or significant previous abdominal surgery. Benchmarks were established for 13 outcome parameters. Result: The benchmark cohort comprised 418 patients from 12 centers across four continents. Benchmark values were: conversion rate ≤4.3%, transfusion rate ≤2.1%, 6-month mortality ≤2.2%, major complications ≤23.2%, and CCI® ≤20.9. Clinically relevant pancreatic fistula (grade B/C) and hemorrhage (grade B/C) rates were ≤23.6% and ≤12.7%, respectively. For pancreatic ductal adenocarcinoma (n=123), the benchmark for lymph node yield was ≥20. Higher surgical difficulty was associated with increased overall postoperative morbidity (R 2 =0.38, P =0.019), higher center caseload with reduced pancreas-specific complications (R 2 =0.28, P =0.044). Independent POPF predictors included duct diameter ≤4 mm (OR 1.37, 95% CI: 1.03, 1.82), anticoagulation (OR 2.45, 95% CI: 1.47, 3.99), and indication other than PDAC (OR 2.33, 95% CI: 1.68, 3.27). Conclusions: This study establishes the first international benchmarks for robotic Whipple, demonstrating oncologic outcomes and morbidity comparable to open surgery with the benefits of minimally invasive surgery.
Recommendations on Perihilar Cholangiocarcinoma. The Milan Jury-Based Consensus
Objective: To establish comprehensive recommendations on the management of perihilar cholangiocarcinoma (pCCA) and to identify areas in need of future investigation. Summary Background Data: The lack of consensus in management of pCCA across institutions worldwide impairs optimal patient care and best-achievable oncological outcome. A holistic and critical assessment of the body of evidence and collaborative guidance are required. Methods: The Consensus4pCCA conference developed unbiased consensus using the Zurich-Danish model. An impartial and multidisciplinary jury adopted comprehensive recommendations grounded on the work of eight expert panels answering predefined clinical questions and considering the best-quality evidence through a systematic review. The development of recommendations complied with GRADE and SIGN50 methodologies. Results: Seventy-one international experts considered 570 studies. Ten jury members concluded 71 recommendations covering definition and diagnosis, preoperative assessment and optimization, surgical resection, liver transplantation, and outcome reporting for pCCA patients. The consensus underscored that making patients amenable to high-quality curative resection and reducing its associated morbidity must be of highest priority. As such, multidisciplinary expertise and centralized care at all stages of disease management are critical to ensure both safety and oncological adequacy. To overcome the evidence-gap for rare diseases like pCCA, the jury urged large-scale registries to address open questions across the disease continuum and highlighted priorities for future investigation. Conclusion: The Consensus4pCCA represents an unprecedented commitment to collectively harmonize global treatment strategies for pCCA. This collective effort bridges the gap between expert opinions and clinical evidence and holds great promise to improve patient outcomes in the future.
Novel Benchmark for Robotic Liver Resection – Bridging Tradition with Innovation
Objective: To establish benchmark cutoffs for robotic liver resection (R-LR), encompassing both major and minor resections, and to determine the impact of patient selection on outcomes. Background: R-LR is a key advancement in minimally invasive liver surgery but lacks standardized benchmarks, especially for minor resections. While guidelines endorse R-LR, its role in optimizing outcomes remains unclear. This study establishes the first benchmarks for R-LR, enabling comparisons across surgical modalities and refining patient selection. Methods: This retrospective, multicenter study analyzed consecutive adult patients undergoing R-LR at 30 international centers (2020–2023). Benchmark centers had an annual case volume of ≥15 R-LR. Benchmark criteria included ASA ≤2, no major comorbidities, no prior liver resections, and Child-Pugh A status. Benchmark cutoffs for 14 key outcomes were set at the 50th and 75th percentiles of median values across benchmark centers. Multivariable logistic regression identified predictors of textbook outcomes. Results: Eighteen high-volume centers contributed 4028 cases with 2632 (65.3%) meeting benchmark criteria. Malignancy was the indication in 29.6%, most commonly hepatocellular carcinoma followed by colorectal liver metastases. Major liver resection was performed in 42.6%. The distribution of Iwate difficulty scores was low (25.4%), intermediate (53.9%), advanced (15.9%), and expert (4.9%). Benchmark cutoffs were established for minor and major resection, and stratified by Iwate low (0-3), intermediate (4-6) and high (7-12): Open conversion (≤6.5% minor, ≤10.5% major), major complications within 90 days (≤5.2% minor, ≤16.7% major), R1 resection (≤9.2% minor, ≤6.7% major). Benchmark cases performed at low-volume centers were able to achieve outcomes within the corresponding benchmark cutoffs. In fact, patient selection reflected by the proportion of benchmark patients, rather than case volume, was associated with textbook outcomes. Conclusions: This study defines R-LR benchmarks, emphasizing patient selection over center volume for optimal outcomes. Benchmark cutoffs guide training and support the expansion of R-LR.
Novel Benchmarks for Robotic Whipple Surgery - A Global Multicenter Cohort Study
Abstract Background Robotic Whipple holds the promise to overcome safety concerns associated with laparoscopy, paving the way for widespread implementation of minimal-invasive surgery in this complex procedure. However, randomized data comparing robot vs. open Whipple demonstrate more pancreas-specific complications and R1-resections in the robotic arm. Recent international consensus identified establishing benchmarks as critical to ensure safe adoption of the robot. Benchmarking is a validated quality improvement tool, enabling comparison of surgical performance. Aims The aim was to define benchmarks for outcome parameters in robotic Whipple. Methods We analyzed consecutive patients undergoing robotic Whipple from January 2020 until December 2023 in 11 centers across 4 continents, with a minimum one-year follow-up. Centers had to perform ≥15 cases/year and have mounted their learning curve. Benchmark criteria included benign or resectable malignant disease without neoadjuvant therapy, arterial resection, major co-morbidities, or significant previous abdominal surgery. Medians across centers represented benchmark cutoffs. Results Eleven centers performed 1’037 Whipple procedures, of which 603 (58%) were benchmark cases. One third (n=192) were pancreatic ductal adenocarcinoma (PDAC) patients. Key benchmarks at 6 months included ≤1.2% mortality, ≤24.2% major complications, and ≤ 8.7 points Comprehensive Complication Index®. Pancreas-specific cutoffs included ≤13.0% postoperative pancreatic fistula (POPF) B/C and ≤3.4% post-pancreatectomy hemorrhage B/C, with 100% R0-resection and ≥19 harvested lymph nodes in PDAC patients. One-year actuarial overall and recurrence-free survival was 87% and 77%. In the entire cohort POPF B/C occurred in 16% (n=195). Independent POPF predictors included duct diameter ≤4mm (OR 1.79 95%CI [1.27-2.55]), anticoagulation (OR 3.68 95%CI [2.14-6.24]), and indication other than PDAC (OR 3.17, 95%CI [2.13-4.85]). Conclusion This study establishes benchmarks for key outcomes in robotic Whipple, demonstrating oncologic adequacy and morbidity comparable to open surgery. Risk factors for POPF in open surgery also hold true in the robotic approach.