Back to Authors

Karau, Melissa J.

https://orcid.org/0000-0001-6021-4033

Mayo Clinic

Mayo Clinic

Citations 53

Antimicrobial Susceptibility and Clonality of Clinical Ureaplasma Isolates in the United States
Fernández, Javier , Karau, Melissa J. , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Antimicrobial Agents and Chemotherapy | June 1, 2016 | Volume: 60 | Issue: 8 | Pages: 4793-4798

10.1128/aac.00671-16 Get It

ABSTRACT Ureaplasma urealyticum and Ureaplasma parvum are pathogens involved in urogenital tract and intrauterine infections and also in systemic diseases in newborns and immunosuppressed patients. There is limited information on the antimicrobial susceptibility and clonality of these species. In this study, we report the susceptibility of 250 contemporary isolates of Ureaplasma (202 U. parvum and 48 U. urealyticum isolates) recovered at Mayo Clinic, Rochester, MN. MICs of doxycycline, azithromycin, ciprofloxacin, tetracycline, erythromycin, and levofloxacin were determined by broth microdilution, with MICS of the last three interpreted according to CLSI guidelines. Levofloxacin resistance was found in 6.4% and 5.2% of U. parvum and U. urealyticum isolates, respectively, while 27.2% and 68.8% of isolates, respectively, showed ciprofloxacin MICs of ≥4 μg/ml. The resistance mechanism of levofloxacin-resistant isolates was due to mutations in parC , with the Ser83Leu substitution being most frequent, followed by Glu87Lys. No macrolide resistance was found among the 250 isolates studied; a single U. parvum isolate was tetracycline resistant. tet (M) was found in 10 U. parvum isolates, including the single tetracycline-resistant isolate, as well as in 9 isolates which had low tetracycline and doxycycline MICs. Multilocus sequence typing (MLST) performed on a selection of 46 isolates showed high diversity within the clinical Ureaplasma isolates studied, regardless of antimicrobial susceptibility. The present work extends previous knowledge regarding susceptibility to antimicrobial agents, resistance mechanisms, and clonality of Ureaplasma species in the United States.
Direct Electrical Current Reduces Bacterial and Yeast Biofilm Formation
Ruiz‐Ruigómez, María , Badiola, Jon , Schmidt-Malan, Suzannah M., Greenwood‐Quaintance, Kerryl E. , Karau, Melissa J. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Greenwood-Quaintance, Kerryl, Patel, Robin

International Journal of Bacteriology | March 17, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-6

10.1155/2016/9727810 Get It

New strategies are needed for prevention of biofilm formation. We have previously shown that 24 hr of 2,000 µA of direct current (DC) reducesStaphylococcus epidermidisbiofilm formationin vitro. Herein, we examined the effect of a lower amount of DC exposure onS. epidermidis,Staphylococcus aureus,Escherichia coli,Pseudomonas aeruginosa,Propionibacterium acnes, andCandida albicansbiofilm formation. 12 hr of 500 µA DC decreasedS. epidermidis,S. aureus,E. coli, andP. aeruginosabiofilm formation on Teflon discs by 2, 1, 1, and 2 log10cfu/cm2, respectively (p<0.05). Reductions inS. epidermidis,S. aureus, andE. colibiofilm formation were observed with as few as 12 hr of 200 µA DC (2, 2 and 0.4 log10 cfu/cm2, resp.); a 1 log10 cfu/cm2reduction inP. aeruginosabiofilm formation was observed at 36 hr. 24 hr of 500 µA DC decreasedC. albicansbiofilm formation on Teflon discs by 2 log10 cfu/cm2. No reduction inP. acnesbiofilm formation was observed. 1 and 2 log10 cfu/cm2reductions inE. coliandS. epidermidisbiofilm formation on titanium discs, respectively, were observed with 12 hr of exposure to 500 µA. Electrical current is a potential strategy to reduce biofilm formation on medical biomaterials.
Antibiofilm Activity of Electrical Current in a Catheter Model
Voegele, Paul, Badiola, Jon , Schmidt-Malan, Suzannah M., Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | December 29, 2015 | Volume: 60 | Issue: 3 | Pages: 1476-1480

10.1128/aac.01628-15 Get It

ABSTRACT Catheter-associated infections are difficult to treat with available antimicrobial agents because of their biofilm etiology. We examined the effect of low-amperage direct electrical current (DC) exposure on established bacterial and fungal biofilms in a novel experimental in vitro catheter model. Staphylococcus epidermidis , Staphylococcus aureus , Escherichia coli , Pseudomonas aeruginosa , and Candida parapsilosis biofilms were grown on the inside surfaces of polyvinyl chloride (PVC) catheters, after which 0, 100, 200, or 500 μA of DC was delivered via intraluminally placed platinum electrodes. Catheter biofilms and intraluminal fluid were quantitatively cultured after 24 h and 4 days of DC exposure. Time- and dose-dependent biofilm killing was observed with all amperages and durations of DC administration. Twenty-four hours of 500 μA of DC sterilized the intraluminal fluid for all bacterial species studied; no viable bacteria were detected after treatment of S. epidermidis and S. aureus biofilms with 500 μA of DC for 4 days.
Novel Bone-Targeting Agent for Enhanced Delivery of Vancomycin to Bone
Albayati, Zaineb A.F., Sunkara, Manjula , Schmidt-Malan, Suzannah M., Karau, Melissa J. , Morris, Andrew J. , Steckelberg, James M., Patel, Robin , Breen, Philip J., Smeltzer, Mark S. , Taylor, K. Grant, Merten, Kevyn E., Pierce, William M., Crooks, Peter A. , Patel, Robin

Antimicrobial Agents and Chemotherapy | December 15, 2015 | Volume: 60 | Issue: 3 | Pages: 1865-1868

10.1128/aac.01609-15 Get It

ABSTRACT We examined the pharmacokinetic properties of vancomycin conjugated to a bone-targeting agent (BT) with high affinity for hydroxyapatite after systemic intravenous administration. The results confirm enhanced persistence of BT-vancomycin in plasma and enhanced accumulation in bone relative to vancomycin. This suggests that BT-vancomycin may be a potential carrier for the systemic targeted delivery of vancomycin in the treatment of bone infections, potentially reducing the reliance on surgical debridement to achieve the desired therapeutic outcome.
Superantigen-Producing Staphylococcus aureus Elicits Systemic Immune Activation in a Murine Wound Colonization Model
Kim, Choon Kwan , Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Tilahun, Ashenafi Y. , Krogman, Ashton , David, Chella S., Pritt, Bobbi S. , Patel, Robin , Rajagopalan, Govindarajan , Kim, Choon K, Patel, Robin , Pritt, Bobbi S

Toxins | December 9, 2015 | Volume: 7 | Issue: 12 | Pages: 5308-5319

10.3390/toxins7124886 Get It

Staphylococcus aureus, the most common cause of wound infection, produces several exotoxins, including superantigens (SAgs). SAgs are the potent activators of the immune system. Given this unique property, we hypothesized that SAgs produced by S. aureus in wounds would have local, as well as systemic immunologic effects. We tested our hypothesis using a novel staphylococcal skin wound infection model in transgenic mice expressing HLA-DR3. Skin wounds were left uninfected or colonized with S. aureus strains producing SAgs or an isogenic strain not producing any SAg. Animals with wounds challenged with SAg-producing S. aureus had increased morbidity and lower serum IL-17 levels compared to those challenged with the SAg non-producing S. aureus (p = 0.027 and p = 0.032, respectively). At Day 8 following microbial challenge, compared to mice with uninfected wounds, the proportion of Vβ8+CD4+ T cells was increased, while the proportion of Vβ8+CD8+ T cells was decreased only in the spleens of mice challenged with SAg-producing S. aureus (p < 0.001). No such changes were measured in mice challenged with SAg non-producing S. aureus. Lungs, livers and kidneys from mice challenged with SAg-producing, but not SAg non-producing, S. aureus showed inflammatory changes. Overall, SAg-mediated systemic immune activation in wounds harboring S. aureus may have clinical implications.
Antibiofilm Activity of Low-Amperage Continuous and Intermittent Direct Electrical Current
Schmidt-Malan, Suzannah M., Karau, Melissa J. , Cede, Julia , Greenwood‐Quaintance, Kerryl E. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | May 27, 2015 | Volume: 59 | Issue: 8 | Pages: 4610-4615

10.1128/aac.00483-15 Get It

ABSTRACT Bacterial biofilms are difficult to treat using available antimicrobial agents, so new antibiofilm strategies are needed. We previously showed that 20, 200, and 2,000 μA of electrical current reduced bacterial biofilms of Staphylococcus aureus , Staphylococcus epidermidis , and Pseudomonas aeruginosa . Here, we tested continuous direct current at lower amperages, intermittent direct current, and combinations of surface materials (Teflon or titanium) and electrode compositions (stainless steel, graphite, titanium, or platinum) against S. aureus , S. epidermidis , and P. aeruginosa biofilms. In addition, we tested 200 or 2,000 μA for 1 and 4 days against biofilms of 33 strains representing 13 species of microorganisms. The logarithmic reduction factor was used to measure treatment effects. Using continuous current delivery, the lowest active amperage was 2 μA for 1, 4, or 7 days against P. aeruginosa and 5 μA for 7 days against S. epidermidis and S. aureus biofilms. Delivery of 200 μA for 4 h a day over 4 days reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on Teflon or titanium discs. A reduction of P. aeruginosa , S. aureus , and S. epidermidis biofilms was measured for 23 of 24 combinations of surface materials and electrode compositions tested. Four days of direct current delivery reduced biofilms of 25 of 33 strains studied. In conclusion, low-amperage current or 4 h a day of intermittent current delivered using a variety of electrode compositions reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on a variety of surface materials. The electricidal effect was observed against a majority of bacterial species studied.
Superantigens produced by catheter-associated Staphylococcus aureus elicit systemic inflammatory disease in the absence of bacteremia
Greenwood‐Quaintance, Kerryl E. , Karau, Melissa J. , Tilahun, Ashenafi Y. , Khaleghi, Shahryar, Chowdhary, Vaidehi , David, Chella S., Patel, Robin , Rajagopalan, Govindarajan , Chung, Jin-Won, Tilahun, Ashenafi, Khaleghi, Shahryar Rostamkolaei, Chowdhary, Vaidehi R, Chung, Jin-Won , Patel, Robin

Journal of Leukocyte Biology | May 16, 2015 | Volume: 98 | Issue: 2 | Pages: 271-281

10.1189/jlb.4a1214-577rr Get It

Abstract SAgs, produced by Staphylococcus aureus, play a major role in the pathogenesis of invasive staphylococcal diseases by inducing potent activation of the immune system. However, the role of SAgs, produced by S. aureus, associated with indwelling devices or tissues, are not known. Given the prevalence of device-associated infection with toxigenic S. aureus in clinical settings and the potency of SAgs, we hypothesized that continuous exposure to SAgs produced by catheter-associated S. aureus could have systemic consequences. To investigate these effects, we established a murine in vivo catheter colonization model. One centimeter long intravenous catheters were colonized with a clinical S. aureus isolate producing SAgs or isogenic S. aureus strains, capable or incapable of producing SAg. Catheters were subcutaneously implanted in age-matched HLA-DR3, B6, and AEo mice lacking MHC class II molecules and euthanized 7 d later. There was no evidence of systemic infection. However, in HLA-DR3 transgenic mice, which respond robustly to SSAgs, the SSAg-producing, but not the nonproducing strains, caused a transient increase in serum cytokine levels and a protracted expansion of splenic CD4+ T cells expressing SSAg-reactive TCR Vβ8. Lungs, livers, and kidneys from these mice showed infiltration with CD4+ and CD11b+ cells. These findings were absent in B6 and AEo mice, which are known to respond poorly to SSAgs. Overall, our novel findings suggest that systemic immune activation elicited by SAgs, produced by S. aureus colonizing foreign bodies, could have clinical consequences in humans.
The Impact ofStaphylococcus aureus-Associated Molecular Patterns on Staphylococcal Superantigen-Induced Toxic Shock Syndrome and Pneumonia
Tilahun, Ashenafi Y. , Karau, Melissa J. , Ballard, Alessandro D. , Gunaratna, Miluka P. , Thapa, Anusa , David, Chella S., Patel, Robin , Rajagopalan, Govindarajan , Karau, Melissa , Ballard, Alessandro , Patel, Robin

Mediators of Inflammation | June 12, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-13

10.1155/2014/468285 Get It

Staphylococcus aureusis capable of causing a spectrum of human illnesses. During seriousS. aureusinfections, the staphylococcal pathogen-associated molecular patterns (PAMPs) such as peptidoglycan, lipoteichoic acid, and lipoproteins and even intactS. aureus, are believed to act in conjunction with the staphylococcal superantigens (SSAg) to activate the innate and adaptive immune system, respectively, and cause immunopathology. However, recent studies have shown that staphylococcal PAMPs could suppress inflammation by several mechanisms and protect from staphylococcal toxic shock syndrome, a life-threatening systemic disease caused by toxigenicS. aureus. Given the contradictory pro- and anti-inflammatory roles of staphylococcal PAMPs, we examined the effects ofS. aureus-derived molecular patterns on immune responses driven by SSAgin vivousing HLA-DR3 and HLA-DQ8 transgenic mice. Our study showed that neitherS. aureus-derived peptidoglycans (PGN), lipoteichoic acid (LTA), nor heat-killedStaphylococcus aureus(HKSA) inhibited SSAg-induced T cell proliferationin vitro. They failed to antagonize the immunostimulatory effects of SSAgin vivoas determined by their inability to attenuate systemic cytokine/chemokine response and reduce SSAg-induced T cell expansion. These staphylococcal PAMPs also failed to protect HLA-DR3 as well as HLA-DQ8 transgenic mice from either SSAg-induced toxic shock or pneumonia induced by a SSAg-producing strain ofS. aureus.
Microbial Biofilms and Breast Tissue Expanders
Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Schmidt, Suzannah M., Tran, Nho V. , Convery, Phyllis A., Jacobson, Steven R., Bite, Uldis, Clay, Ricky P., Petty, Paul M., Johnson, C. H. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

BioMed Research International | July 16, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-6

10.1155/2013/254940 Get It

We previously developed and validated a vortexing-sonication technique for detection of biofilm bacteria on the surface of explanted prosthetic joints. Herein, we evaluated this technique for diagnosis of infected breast tissue expanders and used it to assess colonization of breast tissue expanders. From April 2008 to December 2011, we studied 328 breast tissue expanders at Mayo Clinic, Rochester, MN, USA. Of seven clinically infected breast tissue expanders, six (85.7%) had positive cultures, one of which grewPropionibacteriumspecies. Fifty-two of 321 breast tissue expanders (16.2%, 95% CI, 12.3–20.7%) without clinical evidence of infection also had positive cultures, 45 growingPropionibacteriumspecies and ten coagulase-negative staphylococci. While vortexing-sonication can detect clinically infected breast tissue expanders, 16 percent of breast tissue expanders appear to be asymptomatically colonized with normal skin flora, most commonly,Propionibacteriumspecies.
Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection
Cazanave, Charles , Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Karau, Melissa J. , Schmidt, Suzannah M., Urena, Eric O. Gomez, Mandrekar, Jayawant N. , Osmon, Douglas R. , Lough, Lindsay E., Pritt, Bobbi S. , Steckelberg, James M., Patel, Robin , Patel, Robin , Pritt, Bobbi S

Journal of Clinical Microbiology | May 9, 2013 | Volume: 51 | Issue: 7 | Pages: 2280-2287

10.1128/jcm.00335-13 Get It

ABSTRACT We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee ( n = 272) or hip ( n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture ( P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure.