Back to Authors

Li, Bo

https://orcid.org/0000-0002-6129-321X

Mayo Clinic

Amsterdam UMC Location University of Amsterdam

Citations 2

Calibration of Flow Cytometers Enables Reproducible Measurements of Extracellular Vesicle Concentrations and Reference Range Establishment
Bettin, Britta , Li, Bo , Falkena, Kim, Leeuwen, Ton G. van , Gollwitzer, Christian , Varga, Zoltán , Antović, Jovan P. , Berckmans, Pascale , Buzás, Edit I. , Cook, Sean, Dignat‐George, Françoise , Lacroix, Romaric , Maaninka, Katariina , Menezes, Erika G. Marques de , Meyer, Annette, Mizenko, Rachel R. , Nelissen, Inge , Norris, Philip J. , Pink, Desmond , Poudel, Sumeet , Robert, Stéphane, Siljander, Pia , Tang, Vera A. , Broeck, Tina Van Den, Bettin, Britta A , van Leeuwen, Ton G , Ajzenberg, Nadine , Berckmans, Pascale , Buzas, Edit I , Carney, Randy P , Dignat-George, Françoise , Faille, Dorothee , Giebel, Bernd , Jones, Jennifer C , Lacroix, Romaric , Lannigan, Joanne , Lucien, Fabrice , Maaninka, Katariina , de Menezes, Erika G Marques , Mizenko, Rachel R , Nelissen, Inge , Pink, Desmond , Poudel, Sumeet , Siljander, Pia R-M , Tang, Vera A , Tertel, Tobias , Wang, Lili , Welsh, Joshua A , Nieuwland, Rienk , van der Pol, Edwin , Cook, Sean M, Giebel, Bernd , Jones, Jennifer , Kim, Yohan , Lucien, Fabrice , Meyer, Annette, Nolan, John, Welsh, Joshua A , Nieuwland, Rienk

Journal of Extracellular Vesicles | December 15, 2025 | Volume: 14 | Issue: 12 | Pages: No page available

10.1002/jev2.70189 Get It

ABSTRACT The concentration of cells is a key component of modern blood tests. Given the biomarker potential of extracellular vesicles (EVs) in blood, we aimed to establish reference ranges for blood cell‐derived EVs using flow cytometry. To address the orders‐of‐magnitude variability in reported EV concentrations between different flow cytometers (FCMs), we first validated a calibration methodology to enable reproducible EV concentration measurements. The methodology was evaluated in an interlaboratory comparison study and shows that calibration reduces the median absolute deviation of EV concentrations measured on 25 different FCMs from 67 % to 25 %–31 %. The calibration methodology was then used to determine reference ranges of erythrocyte‐, leukocyte‐, and platelet‐derived EVs in human blood plasma in a cohort of healthy individuals ( n = 224). This study demonstrates that calibration enables comparable concentration measurements of blood cell‐derived EVs, thereby bringing EVs one step closer to clinical applications.
MIBlood‐EV: Minimal information to enhance the quality and reproducibility of blood extracellular vesicle research
Lenassi, Metka , Teske, Jacob J. , Boilard, Éric , Hohenberg, Katharina Clemm von , Falcón‐Pérez, Juan Manuel , Gualerzi, Alice , Jones, Jennifer , Lawson, Charlotte, Nazarenko, Irina , Pink, Ryan , Siljander, Pia , Hendrix, An , Witwer, Kenneth W. , Lucien, Fabrice , Lenassi, Metka , Falcón-Perez, Juan Manual , Gualerzi, Alice , Nazarenko, Irina , Pink, Ryan , Siljander, Pia R-M , Welsh, Joshua A , Witwer, Kenneth W , Nieuwland, Rienk , Teske, Jacob J , Jones, Jennifer C , Lucien, Fabrice , Gustafson, Dakota , Li, Bo , Reale, Antonia , Lässer, Cecilia , O’Driscoll, Lorraine , Soekmadji, Carolina , Welsh, Joshua A , Nieuwland, Rienk

Journal of Extracellular Vesicles | December 8, 2023 | Volume: 12 | Issue: 12 | Pages: No page available

10.1002/jev2.12385 Get It

Abstract Blood is the most commonly used body fluid for extracellular vesicle (EV) research. The composition of a blood sample and its derivatives (i.e., plasma and serum) are not only donor‐dependent but also influenced by collection and preparation protocols. Since there are hundreds of pre‐analytical protocols and over forty variables, the development of standard operating procedures for EV research is very challenging. To improve the reproducibility of blood EV research, the International Society for Extracellular Vesicles (ISEV) Blood EV Task Force proposes standardized reporting of (i) the applied blood collection and preparation protocol and (ii) the quality of the prepared plasma and serum samples. Gathering detailed information will provide insight into the performance of the protocols and more effectively identify potential confounders in the prepared plasma and serum samples. To collect this information, the ISEV Blood EV Task Force created the Minimal Information for Blood EV research (MIBlood‐EV), a tool to record and report information about pre‐analytical protocols used for plasma and serum preparation as well as assays used to assess the quality of these preparations. This tool does not require modifications of established local pre‐analytical protocols and can be easily implemented to enhance existing databases thereby enabling evidence‐based optimization of pre‐analytical protocols through meta‐analysis. Taken together, insight into the quality of prepared plasma and serum samples will (i) improve the quality of biobanks for EV research, (ii) guide the exchange of plasma and serum samples between biobanks and laboratories, (iii) facilitate inter‐laboratory comparative EV studies, and (iv) improve the peer review process.