Back to Authors

Batra, Hitesh

https://orcid.org/0000-0002-4934-1434

Mayo Clinic

University of Alabama at Birmingham

Citations 2

Shape-sensing robotic-assisted bronchoscopy with integrated mobile cone-beam CT for small nodules: results from the prospective multicentre CONFIRM study
Husta, Bryan C, Cheng, George Z. , Batra, Hitesh , Reisenauer, J., Bartek, William, Kalchiem‐Dekel, Or , Zouk, Aline, Patel, Niral, Chawla, Mohit, Eapen, George A. , Jiménez, C. Delgado, Lee, R. J., Bott, Matthew J. , Oh, Scott , Casal, Roberto F, Casal, Roberto , Reisenauer, Janani , Zouk, Aline N., Patel, Niral M. , Chawla, Mohit , Casal, Roberto F.

Thorax | February 16, 2026 | Volume: 81 | Issue: 3 | Pages: 267-275

10.1136/thorax-2025-223272 Get It

Background The use of 3D imaging with navigation bronchoscopy has increased with the introduction of mobile cone-beam CT (mCBCT). Shape-sensing robotic-assisted bronchoscopy (ssRAB) integrated with mCBCT has been introduced to correct for CT to body divergence (CT-BD) during the biopsy of peripheral pulmonary nodules (PPNs). Methods Prospective observational multicentre study, enrolling patients with a PPN of ≤20 mm suspicious for malignancy, assessing tool-in-lesion (TIL), diagnostic yield, sensitivity for malignancy and incidence of pneumothorax or airway bleeding. Non-malignant index biopsies were followed for 12 months. Descriptive statistics are reported for all variables along with 95% CI for primary endpoints. Results 155 consecutive patients were enrolled at six centres. Median nodule size was 14.0 mm (IQR 11.0–17.0), with 54.8% of nodules (85/155) in the upper lobes, 25.8% (40/155) with CT bronchus sign present and median distance to the nearest pleural surface of 8.2 mm (IQR 1.8–20.0). TIL was achieved in 154/155 (99.4%, 95% CI 96.5 to 100.0) procedures. A median of two (IQR 1–3) mCBCT spins were performed, with median dose area product of 25.7 Gy · cm 2 (IQR 11.0–46.7). Diagnostic yield per the American Thoracic Society/American College of Chest Physicians (ATC/ACCP) definition was 89.0% (n=138/155; 95% CI 83.0 to 93.5) and sensitivity for malignancy was 91.5% (95% CI 86.4 to 96.5). No pneumothorax (0%, 95% CI 0.0 to 2.4) and two Nashville Grade three bleeding events were reported (1.3%, 95% CI 0.2 to 4.6). Interpretation The first prospective multicentre study of integrated ssRAB and mCBCT for small peripheral nodules resulted in diagnostic outcomes similar to those reported for transthoracic biopsy with a more favourable safety profile. Trial registration number ClinicalTrials.gov ID: NCT05562895 .
Interventional Pulmonary Fellowship Training: End of the Beginning
Lee, Hans J. , Akulian, Jason , Argento, A. Christine , Batra, Hitesh , Lamb, Carla, Mullon, John J., Murgu, Septimiu , Mullon, John

ATS Scholar | September 7, 2023 | Volume: 4 | Issue: 4 | Pages: 405-412

10.34197/ats-scholar.2022-0107ps Get It

Abstract Interventional pulmonology (IP) fellowship training has undergone increased popularity and growth. The Accreditation Council of Graduate Medical Education recently recognized IP medicine as a new subspecialty, which leads to new challenges and opportunities for a young subspecialty. Although the specialty-specific requirements are in progress, IP fellowship programs must plan ahead for the known common program requirements and anticipated accreditation process. The educational leadership in IP must identify and execute solutions to sustain continued excellence. This includes transitioning to a new regulatory environment with issues of funding new fellowships, keeping up to date with training/assessment of new procedures, and shaping the future through recruitment of talent to lead the young subspecialty.