Back to Authors

Zubirán, Rafael

https://orcid.org/0000-0003-4274-3585

Mayo Clinic

National Institutes of Health

Citations 5

Modern Low-Density Lipoprotein Cholesterol Formulas Outperform Direct Methods in Patients with Hypertriglyceridemia and Low Levels of Low-Density Lipoprotein Cholesterol
Meeusen, Jeffrey W. , Yi, Xin , Cotten, Steven W. , Nielsen, J. Nederby, Donato, Leslie J. , Jones, Patricia M , Muthukumar, Alagar R, Zubirán, Rafael , Remaley, Alan T. , Cao, Jing , Donato, Leslie , Nielsen, Jacob B

Clinical Chemistry | August 5, 2025 | Volume: 71 | Issue: 11 | Pages: 1138-1146

10.1093/clinchem/hvaf099 Get It

Abstract Background Direct measurement of low-density lipoprotein cholesterol (LDL-C) is widely used and recommended by professional society guidelines despite its potential limitations in patients with hypertriglyceridemia and low LDL-C. This study evaluated the performance of 3 direct LDL-C (LDL-CD) assays, 2 modern LDL-C calculation methods [LDL-C Martin (LDL-CM), LDL-C modified Sampson (LDL-CS)] and the conventional Friedewald (LDL-CF) method against the reference method, beta-quantification (LDL-CBQ). Methods A total of 181 remnant sera from patients with standard lipid panel orders or from patients with LDL-CBQ orders with triglycerides (TG) ≥ 400 mg/dL (4.5 mmol/L), or with TG ≥ 150 mg/dL (1.69 mmol/L) and LDL-C < 70 mg/dL (1.8 mmol/L) were included. LDL-CD and lipid panel data were gathered from Abbott Alinity, Roche Cobas, and Siemens Atellica platforms. Results LDL-CD among the 3 platforms showed a median CV of 11.2%. In patients with TG <400 mg/dL, LDL-CM and LDL-CS demonstrated less bias and less misclassification at the clinical decision LDL-C levels than LDL-CF or LDL-CD. In the 400 to 800 mg/dL (9.0 mmol/L) TG group, LDL-CS was superior to LDL-CD or LDL-CM in accuracy. When TG is ≥ 800 mg/dL, LDL-CD (Roche) showed substantial bias from LDL-CBQ while LDL-CS (Roche) showed smaller but significant bias. Conclusions In summary, LDL-CD or LDL-CF showed little advantage over the 2 modern LDL-C calculation methods. LDL-CS showed the best overall correlation with LDL-CBQ and therefore is recommended to replace LDL-CF and potentially LDL-CD when making clinical decisions in patients with low LDL-C and hypertriglyceridemia.
Lipid Ratio Plot: A Simple Graphical Approach for Investigating the Accuracy of LDL Cholesterol Equations or Direct Assays
Gcingca, Thando A, Sampson, Maureen , Zubirán, Rafael , Wolska, Anna , Meeusen, Jeffrey W. , Donato, Leslie J. , Jaffe, Allan S. , Remaley, Alan T. , Gcingca, Thando , Meeusen, Jeffrey, Donato, Leslie , Jaffe, Allan S. , Remaley, Alan T

The Journal of Applied Laboratory Medicine | June 16, 2025 | Volume: 10 | Issue: 5 | Pages: 1154-1167

10.1093/jalm/jfaf093 Get It

Abstract Background β-Quantification (BQ) is the reference method for low-density lipoprotein cholesterol (LDL-C) determination. It is not widely available, making it challenging for laboratories to assess the accuracy of LDL-C methods. Our goal was to develop an indirect graphical approach for comparing LDL-C test results to the BQ reference method. Methods BQ results from Mayo Medical Laboratories (n = 39 969) and the National Institutes of Health (n = 17 825) were used to investigate the interrelationships between lipid panel tests. A plot of LDL-C/non high-density lipoprotein cholesterol (nonHDL-C) vs (triglyceride (TG)/nonHDL-C)0.5 (lipid ratio plot) resulted in a negative linear regression line (y = −34.2x + 115). Based on simulation analysis, the minimum sample size for calculating its slope and intercept with a coefficient of variation of about 7.5% was 80. Results The regression lines for the lipid ratio plot of LDL-C calculated by the Sampson–NIH (y = −37.6x + 118) and enhanced Sampson–NIH (y = −33.1x + 116) equations closely overlapped with the BQ method. In contrast, the Martin–Hopkins equation showed a positive bias with an increasing TG/nonHDL-C ratio and exceeded the recommended bias limit of 4% on hypertriglyceridemic samples (y = −25.5x + 107). The Friedewald equation showed an even larger negative bias with hypertriglyceridemia (y = −47.5x + 126). Lipid ratio plots of the Roche direct assay revealed a fixed positive bias of approximately 4% (y = −33.9x + 120), whereas a much larger proportional positive bias was observed with increasing triglycerides for the Beckman direct assay (y = −14.6x + 97.8). Conclusions The lipid ratio plot is a simple graphical approach that can be readily performed by clinical laboratories for investigating the accuracy of LDL-C assays by calculation methods or direct assays.
A Modified Sampson–NIH Equation with Improved Accuracy for Estimating Low Levels of Low-Density Lipoprotein-Cholesterol
Sampson, Maureen , Zubirán, Rafael , Wolska, Anna , Meeusen, Jeffrey W. , Donato, Leslie J. , Jaffe, Allan S. , Sabatine, Marc S. , Marston, Nicholas , Remaley, Alan T. , Marston, Nicholas A , Remaley, Alan T , Donato, Leslie , Jaffe, Allan S. , Melloni, Giorgio E. M. , Giugliano, Robert Patrick

Clinical Chemistry | June 5, 2025 | Volume: 71 | Issue: 11 | Pages: 1125-1137

10.1093/clinchem/hvaf073 Get It

Abstract Background Cardiovascular guidelines have long recommended low-density lipoprotein-cholesterol (LDL-C) as the primary target for lipid-lowering therapy. Recent guidelines have emphasized the importance of achieving low LDL-C levels; hence, the accurate measurement of low LDL-C is increasingly clinically relevant. Methods Using lipid panel test results from the Mayo Clinic (n = 24 590) and the FOURIER clinical trial of evolocumab (n = 9605), the following modified Sampson equation was developed by least-squares regression to match LDL-C (mg/dL) by the β-quantification reference method, by combining terms into non High Density Lipoprotein Cholesterol (nonHDLC = Total Cholesterol – High Density Lipoprotein Cholesterol) and forcing the coefficient to be one: Results The modified Sampson equation demonstrated significant improvement in its concordance to the reference method compared to other equations (the Lin Concordance Correlation Coefficient 0.992, P < 0.001). By overall kappa analysis, it showed the best agreement to the reference method at the 55 mg/dL cutpoint (1.4 mmol/L, 0.98 [P < 0.001], Sampson–NIH: 0.96, Martin–Hopkins: 0.96, Friedewald: 0.94) and the 70 mg/dL cutpoint (1.8 mmol/L, 0.97 [P < 0.001], Sampson–NIH: 0.94, Martin–Hopkins: 0.95, Friedewald: 0.92). The false classification rate of the modified Sampson equation was also significantly lower compared to the other equations at 55 mg/dL (15%, [P < 0.001], Sampson–NIH: 29%, Martin–Hopkins: 28%, Friedewald: 37%) and 70 mg/dL (18%, [P < 0.001]; Sampson–NIH: 30%, Martin–Hopkins: 28.%, Friedewald: 34%). The new equation increases the percentage of correctly classified patients with low LDL-C by approximately 10% to 20% over the other equations based on its net reclassification index. Conclusions The modified Sampson equation shows improved accuracy compared to other equations for low LDL-C. It more accurately identifies high-risk patients, who are not at their LDL-C goals and could benefit from more intensive lipid-lowering therapy.
A-228 Evaluation of an Equation for Low-Density Lipoproteins-Triglycerides in Predicting ASCVD Risk in the UK Biobank Population
Meeusen, Jeffrey W. , Jaffe, Allan S. , Remaley, Alan T. , Wolska, Anna , Sampson, Maureen , Zubirán, Rafael , Donato, Leslie J. , Jaffe, Allan S.

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.225 Get It

Abstract Background Low-density lipoprotein-cholesterol (LDL-C) is the main univariate risk marker recommended for initial atherosclerotic cardiovascular disease (ASCVD) risk stratification. LDL, however, transports other constituents that can serve as pro-atherogenic risk markers. Like LDL-C, the triglyceride content of LDL (LDL-TG) can also be estimated from the lipid panel. Using data from UK Biobank (UKB), we compared LDL-C to LDL-TG for predicting future ASCVD events. Methods A UKB dataset (N=270,436) of primary prevention individuals not on lipid lowering therapy was used for analysis. LDL-C was calculated by the following equations: Friedewald, Extended Martin-Hopkins, Sampson-NIH, and Enhanced Sampson-NIH. LDL-TG was calculated by our newly devised equation (eLDL-TG = TG/38.46 + nonHDL-C/5.75 + (TG/nonHDL-C)/0.103 + (1/HDL-C)/0.0041 - 2.95)), which was derived from a dyslipidemic cohort (N=40,202) analyzed by the beta-quantification reference method. Results Although there was only a modest comparison between eLDL-TG and measured LDL-TG (R2=0.601, slope=0.611), eLDL-TG appeared to be a better risk marker than LDL-C in UKB. When the population was divided into quintiles and analyzed by survival curve analysis, eLDL-TG was better than LDL-C in segregating patients into low- and high-risk groups (Figure). Similar findings on the relative value of LDL-TG over other risk markers were also found when analyzed by ROC analysis (AUC: eLDL-TG>HDL-C>remnant-cholesterol>NonHDL-C>TG>apoB>Sampson-NIH-LDL-C). By Cox-proportional hazard analysis eLDL-TG showed alongside apoB and NonHDL-C the strongest association with future ASCVD events. Discordance analysis showed that when stratified as LDL-TG/LDL-C as High/Low there was an 26% increased risk for ASCVD, and when as High/High showed an 40% increased risk for ASCVD. Conclusions Like LDL-C, LDL-TG levels can also be estimated from the standard lipid panel. If our findings hold in other populations, the superiority of LDL-TG over LDL-C as a risk marker suggest that the reporting of calculated LDL-TG along with LDL-C could be a new strategy for improving ASCVD risk stratification.
Accuracy and Clinical Impact of Estimating Low-Density Lipoprotein-Cholesterol at High and Low Levels by Different Equations
Sampson, Maureen , Wolska, Anna , Cole, Justine , Zubirán, Rafael , Otvos, James D. , Meeusen, Jeff W., Jaffe, Allan S. , Remaley, Alan T. , Donato, Leslie J. , Meeusen, Jeffrey W. , Jaffe, Allan S.

Biomedicines | December 7, 2022 | Volume: 10 | Issue: 12 | Pages: 3156

10.3390/biomedicines10123156 Get It

New more effective lipid-lowering therapies have made it important to accurately determine Low-density lipoprotein-cholesterol (LDL-C) at both high and low levels. LDL-C was measured by the β-quantification reference method (BQ) (N = 40,346) and compared to Friedewald (F-LDL-C), Martin (M-LDL-C), extended Martin (eM-LDL-C) and Sampson (S-LDL-C) equations by regression analysis, error-grid analysis, and concordance with the BQ method for classification into different LDL-C treatment intervals. For triglycerides (TG) < 175 mg/dL, the four LDL-C equations yielded similarly accurate results, but for TG between 175 and 800 mg/dL, the S-LDL-C equation when compared to the BQ method had a lower mean absolute difference (mg/dL) (MAD = 10.66) than F-LDL-C (MAD = 13.09), M-LDL-C (MAD = 13.16) or eM-LDL-C (MAD = 12.70) equations. By error-grid analysis, the S-LDL-C equation for TG > 400 mg/dL not only had the least analytical errors but also the lowest frequency of clinically relevant errors at the low (<70 mg/dL) and high (>190 mg/dL) LDL-C cut-points (S-LDL-C: 13.5%, F-LDL-C: 23.0%, M-LDL-C: 20.5%) and eM-LDL-C: 20.0%) equations. The S-LDL-C equation also had the best overall concordance to the BQ reference method for classifying patients into different LDL-C treatment intervals. The S-LDL-C equation is both more analytically accurate than alternative equations and results in less clinically relevant errors at high and low LDL-C levels.