Back to Authors

Stybayeya, Gulnaz

0000-0002-1453-245X

Mayo Clinic

Mayo Clinic

Citations 16

Comparison of Liquid-Based Preparations with Conventional Smears in Thyroid Fine-Needle Aspirates: A Systematic Review and Meta-Analysis
Lee, Hyeon Woo, Stybayeva, Gulnaz , Hwang, Se Hwan , Stybayeya, Gulnaz , Hwang, Se Hwan , Kang, Yun Jin

Cancers | February 12, 2024 | Volume: 16 | Issue: 4 | Pages: 751

10.3390/cancers16040751 Get It

Background: To compare conventional smears (CSs) and liquid-based preparations (LBPs) for diagnosing thyroid malignant or suspicious lesions. Methods: Studies in the PubMed, SCOPUS, Embase, Web of Science, and Cochrane database published up to December 2023. We reviewed 17 studies, including 15,861 samples. Results: The diagnostic odds ratio (DOR) for CS was 23.6674. The area under the summary receiver operating characteristic curve (AUC) was 0.879, with sensitivity, specificity, negative predictive value, and positive predictive value of 0.8266, 0.8668, 0.8969, and 0.7841, respectively. The rate of inadequate specimens was 0.1280. For LBP, the DOR was 25.3587, with an AUC of 0.865. The sensitivity, specificity, negative predictive value, and positive predictive value were 0.8190, 0.8833, 0.8515, and 0.8562. The rate of inadequate specimens was 0.1729. For CS plus LBP, the AUC was 0.813, with a lower DOR of 9.4557 compared to individual methods. Diagnostic accuracy did not significantly differ among CS, LBP, and CS plus LBP. Subgroup analysis was used to compare ThinPrep and SurePath. The DORs were 29.1494 and 19.7734. SurePath had a significantly higher AUC. Conclusions: There was no significant difference in diagnostic accuracy or proportion of inadequate smears between CS and LBP. SurePath demonstrated higher diagnostic accuracy than ThinPrep. Recommendations for fine-needle aspiration cytology should consider cost, feasibility, and accuracy.
Effect of Infraorbital and/or Infratrochlear Nerve Blocks on Postoperative Care in Patients with Septorhinoplasty: A Meta-Analysis
Kim, Do Hyun , Park, Jun‐Beom , Kim, Sung Won , Stybayeva, Gulnaz , Hwang, Se Hwan , Stybayeya, Gulnaz , Kim, Do Hyun , Hwang, Se Hwan

Medicina | September 14, 2023 | Volume: 59 | Issue: 9 | Pages: 1659

10.3390/medicina59091659 Get It

Background and Objectives: Through a comprehensive meta-analysis of the pertinent literature, this study evaluated the utility and efficacy of perioperative infraorbital and/or infratrochlear nerve blocks in reducing postoperative pain and related morbidities in patients undergoing septorhinoplasty. Materials and Methods: We reviewed studies retrieved from the PubMed, SCOPUS, Embase, Web of Science, and Cochrane databases up to August 2023. The analysis included a selection of seven articles that compared a treatment group receiving perioperative infraorbital and/or infratrochlear nerve blocks with a control group that either received a placebo or no treatment. The evaluated outcomes covered parameters such as postoperative pain, the amount and frequency of analgesic medication administration, the incidence of postoperative nausea and vomiting, as well as the manifestation of emergence agitation. Results: The treatment group displayed a significant reduction in postoperative pain (mean difference = −1.7236 [−2.6825; −0.7646], I2 = 98.8%), as well as a significant decrease in both the amount (standardized mean difference = −2.4629 [−3.8042; −1.1216], I2 = 93.0%) and frequency (odds ratio = 0.3584 [0.1383; 0.9287], I2 = 59.7%) of analgesic medication use compared to the control. The incidence of emergence agitation (odds ratio = 0.2040 [0.0907; 0.4590], I2 = 0.0%) was notably lower in the treatment group. The incidence of postoperative nausea and vomiting (odds ratio = 0.5393 [0.1309; 2.2218], I2 = 60.4%) showed a trend towards reduction, although it was not statistically significant. While no adverse effects reaching statistical significance were reported in the analyzed studies, hematoma (proportional rate = 0.2133 [0.0905; 0.4250], I2 = 76.9%) and edema (proportional rate = 0.1935 [0.1048; 0.3296], I2 = 57.2%) after blocks appeared at rates of approximately 20%. Conclusions: Infraorbital and/or infratrochlear nerve blocks for septorhinoplasty effectively reduce postoperative pain and emergence agitation without notable adverse outcomes.
Guiding Hepatic Differentiation of Pluripotent Stem Cells Using 3D Microfluidic Co-Cultures with Human Hepatocytes
Fattahi, Pouria , Hoyos‐Vega, José M. de , Duffy, Caden D., Gonzalez‐Suarez, Alan M. , Ishida, Yuji , Nguyen, Kianna M. , Gwon, Kihak , Peterson, Quinn P. , Saito, Takeshi , Stybayeva, Gulnaz , Revzin, Alexander , de Hoyos-Vega, Jose M , Choi, Jong Hoon , Gonzalez-Suarez, Alan M , Nguyen, Kianna M , Saito, Takeshi , Stybayeya, Gulnaz , Gwon, Kihak , Peterson, Quinn , Choi, Jong Hoon

Cells | August 1, 2023 | Volume: 12 | Issue: 15 | Pages: 1982

10.3390/cells12151982 Get It

Human pluripotent stem cells (hPSCs) are capable of unlimited proliferation and can undergo differentiation to give rise to cells and tissues of the three primary germ layers. While directing lineage selection of hPSCs has been an active area of research, improving the efficiency of differentiation remains an important objective. In this study, we describe a two-compartment microfluidic device for co-cultivation of adult human hepatocytes and stem cells. Both cell types were cultured in a 3D or spheroid format. Adult hepatocytes remained highly functional in the microfluidic device over the course of 4 weeks and served as a source of instructive paracrine cues to drive hepatic differentiation of stem cells cultured in the neighboring compartment. The differentiation of stem cells was more pronounced in microfluidic co-cultures compared to a standard hepatic differentiation protocol. In addition to improving stem cell differentiation outcomes, the microfluidic co-culture system described here may be used for parsing signals and mechanisms controlling hepatic cell fate.
Diagnostic Performance of Various Ultrasound Risk Stratification Systems for Benign and Malignant Thyroid Nodules: A Meta-Analysis
Kim, Ji‐Sun , Kim, Byung Guk , Stybayeva, Gulnaz , Hwang, Se Hwan , Stybayeya, Gulnaz , Hwang, Se Hwan

Cancers | January 9, 2023 | Volume: 15 | Issue: 2 | Pages: 424

10.3390/cancers15020424 Get It

Background: To evaluate the diagnostic performance of ultrasound risk-stratification systems for the discrimination of benign and malignant thyroid nodules and to determine the optimal cutoff values of individual risk-stratification systems. Methods: PubMed, Embase, SCOPUS, Web of Science, and Cochrane library databases were searched up to August 2022. Sensitivity and specificity data were collected along with the characteristics of each study related to ultrasound risk stratification systems. Results: Sixty-seven studies involving 76,512 thyroid nodules were included in this research. The sensitivity, specificity, diagnostic odds ratios, and area under the curves by K-TIRADS (4), ACR-TIRADS (TR5), ATA (high suspicion), EU-TIRADS (5), and Kwak-TIRADS (4b) for malignancy risk stratification of thyroid nodules were 92.5%, 63.5%, 69.8%, 70.6%, and 95.8%, respectively; 62.8%, 89.6%, 87.2%, 83.9%, and 63.8%, respectively; 20.7111, 16.8442, 15.7398, 12.2986, and 38.0578, respectively; and 0.792, 0.882, 0.859, 0.843, and 0.929, respectively. Conclusion: All ultrasound-based risk-stratification systems had good diagnostic performance. Although this study determined the best cutoff values in individual risk-stratification systems based on statistical assessment, clinicians could adjust or alter cutoff values based on the clinical purpose of the ultrasound and the reciprocal changes in sensitivity and specificity.
Diagnostic Performance of ACR and Kwak TI-RADS for Benign and Malignant Thyroid Nodules: An Update Systematic Review and Meta-Analysis
Kang, Yun Jin , Stybayeya, Gulnaz , Lee, Ju Eun , Hwang, Se Hwan , Stybayeva, Gulnaz , Hwang, Se Hwan , Lee, Ju Eun

Cancers | December 2, 2022 | Volume: 14 | Issue: 23 | Pages: 5961

10.3390/cancers14235961 Get It

(1) Background: To determine the optimal cut-off values of two risk stratification systems to discriminate malignant thyroid nodules and to compare the diagnostic performance; (2) Methods: True and false positive and negative data were collected, and methodological quality was assessed for forty-six studies involving 39,085 patients; (3) Results: The highest area under the receiver operating characteristic (ROC) curve (AUC) of ACR and Kwak TI-RADS were 0.875 and 0.884. Based on the optimal sensitivity and specificity, the highest accuracy values of ROC curves or diagnostic odds ratios (DOR) were taken as the cut-off values for TR4 (moderate suspicious) and 4B. The sensitivity, specificity, DOR, and AUC by ACR (TR4) and Kwak TI-RADS (4B) for malignancy risk stratification of thyroid nodules were 94.3% and 96.4%; 52.2% and 53.7%; 17.5185 and 31.8051; 0.786 and 0.884, respectively. There were no significant differences in diagnostic accuracy in any of the direction comparisons of the two systems; (4) Conclusions: ACR and Kwak TI-RADS had good diagnostic performances (AUCs > 85%). Although we determined the best cut-off values in individual risk stratification systems based on statistical assessment, clinicians can adjust the optimal cut-off value according to the clinical purpose of the ultrasonography because raising or lowering cut-points leads to reciprocal changes in sensitivity and specificity.
Hepatocyte cultures: From collagen gel sandwiches to microfluidic devices with integrated biosensors
Hoyos‐Vega, José M. de , Hong, Hye Jin , Stybayeva, Gulnaz , Revzin, Alexander , de Hoyos-Vega, Jose M , Stybayeya, Gulnaz

APL Bioengineering | October 14, 2021 | Volume: 5 | Issue: 4 | Pages: No page available

10.1063/5.0058798 Get It

Hepatocytes are parenchymal cells of the liver responsible for drug detoxification, urea and bile production, serum protein synthesis, and glucose homeostasis. Hepatocytes are widely used for drug toxicity studies in bioartificial liver devices and for cell-based liver therapies. Because hepatocytes are highly differentiated cells residing in a complex microenvironment in vivo, they tend to lose hepatic phenotype and function in vitro. This paper first reviews traditional culture approaches used to rescue hepatic function in vitro and then discusses the benefits of emerging microfluidic-based culture approaches. We conclude by reviewing integration of hepatocyte cultures with bioanalytical or sensing approaches.