Abstract Objectives To compare the efficacy and safety of pharmacologic therapies for spontaneous epistaxis in hereditary hemorrhagic telangiectasia (HHT). Data Sources PubMed, Scopus, Embase, Web of Science, and the Cochrane Library were systematically searched up to August 2025. Review Methods Eligible randomized controlled trials evaluating bevacizumab, doxycycline, tranexamic acid, or β‐blockers versus placebo or standard care were included. Outcomes included epistaxis frequency and duration, hemoglobin (Hb), epistaxis severity score (ESS), transfusion or emergent‐care requirements, quality of life (QOL), and adverse events. Results Tranexamic acid did not significantly reduce epistaxis duration or frequency or improve Hb, and it did not change transfusion or emergent‐care needs, but it increased diarrhea (odds ratio 3.8, 95% confidence interval [CI] [1.7; 8.5]). Bevacizumab produced a modest reduction in epistaxis frequency (standardized mean difference −0.25, 95% CI [−0.47; −0.02]), without significant effects on duration, ESS, Hb, or QOL. Doxycycline showed no significant benefit for duration or frequency. Topical or systemic β‐blockers did not significantly affect ESS, QOL, Hb, or overall adverse events. Across agents, between‐study heterogeneity was generally low to moderate and CIs were wide, reflecting limited sample sizes. Conclusion No pharmacologic agent demonstrated consistent, clinically robust superiority over placebo across primary endpoints. Bevacizumab may modestly reduce bleeding burden, whereas tranexamic acid increases gastrointestinal toxicity without clear efficacy. Pharmacologic control of HHT‐related epistaxis remains suboptimal, underscoring the need for adequately powered trials with standardized outcome measures and optimized dosing and delivery strategies.
Effect of Exhalation Delivery System With Fluticasone for Chronic Rhinosinusitis: A Systematic Review and Meta-Analysis
An exhalation delivery system for fluticasone (EDS-FLU) is designed to deposit drug into sinonasal regions above the inferior turbinate, particularly sinus drainage pathways not reached by standard nasal steroid sprays. We evaluated the efficacy and safety of EDS-FLU for chronic rhinosinusitis (CRS). We reviewed four independent randomized controlled trials derived from three published articles identified through searches of PubMed, Embase, SCOPUS, Google Scholar, Web of Science, and the Cochrane Library up to April 2024. Outcomes included 22-item Sinonasal Outcome Test (SNOT-22) scores, nasal symptom scores, nasal polyp scores, patient global impression of change (PGIC), responder and surgical indication rates, and adverse events. Compared with EDS-placebo, EDS-FLU produced greater reductions in nasal polyp scores and SNOT-22 scores over 6 months. At 3 months, nasal congestion, facial pain, rhinorrhea, and olfactory dysfunction improved more with EDS-FLU, and PGIC responder and complete response rates were higher at 3 and 6 months. EDS-FLU reduced surgical indication and increased overall responder rates at 3 months but not at 6 months. Epistaxis and nasal septal erosion or ulceration occurred more frequently with EDS-FLU, whereas rates of headache, nasal congestion, nasopharyngitis, and upper respiratory infection were similar between groups. EDS-FLU provides clinically meaningful improvements in subjective and objective outcomes in CRS but is associated with an increased risk of local nasal adverse events, warranting individualized risk-benefit assessment.
Role of Xylitol Nasal Irrigation in the Management of Chronic Sinusitis: A Systematic Review and Meta‐Analysis
ABSTRACT Objectives Xylitol, a low‐permeability sugar alcohol, is recommended for treating chronic rhinosinusitis (CRS) due to its ability to decrease liquid salt concentration at the airway surface. This study investigated the efficacy of xylitol nasal irrigation for the management of CRS and its postoperative care. Methods We analysed 7 studies with 263 participants after reviewing the studies that were retrieved from PubMed, SCOPUS, Embase, Web of Science, and Cochrane databases up to December 2024. Those comparing changes in endoscopic score, Sinonasal Outcome Test (SNOT), Nasal Obstruction Symptom Evaluation (NOSE), olfactory dysfunction, and CRS‐related visual analogue scale from baseline to post‐treatment between xylitol and normal saline nasal irrigation groups were analysed. Results Nasal irrigation with xylitol significantly improved sinonasal well‐being in CRS patients compared to irrigation with saline (SMD 0.6253, 95% CI [0.0067; 1.2438]; I 2 = 0.0%). Patients who underwent endoscopic sinus surgery showed substantial SNOT improvement (SMD 3.1284, 95% CI [0.5229; 5.7338]; I 2 = 86.1%), while no significant changes were observed in non‐ESS patients (SMD 0.2571, 95% CI [−0.4872; 1.0014]). The xylitol group also showed significant improvements in NOSE (SMD 0.5976, 95% CI [0.2297; 0.9656]; I 2 = 49.3%) and SNOT scores (SMD 0.3608, 95% CI [0.0724; 0.6493]; I 2 = 49.1%). However, there were no significant changes in endoscopic scoring (SMD 0.1309, 95% CI [−0.1777; 0.4396]; I 2 = 0.0%), olfaction (SMD −0.0292, 95% CI [−0.3633; 0.3050]; I 2 = 0.0%), or saccharine clearance time (SMD 0.3816, 95% CI [−0.3816; 1.1449]; I 2 = 61.6%). Xylitol irrigation was well tolerated, with minimal, transient side effects and no significant adverse events. Conclusion Nasal irrigation with xylitol significantly improves the subjective management of CRS and postoperative care compared to saline irrigation but does not alter objective outcomes.
Effect of the BiZact™ Low-Temperature Dissecting Device on Intra- and Postoperative Morbidities Related to Tonsillectomy—A Systematic Review and Meta-Analysis
Background and Objectives: We investigated the effects of using a BiZact™ device for tonsillectomy on operating time, intraoperative blood loss, postoperative bleeding rate, and pain through a meta-analysis of the relevant literature. Materials and Methods: We reviewed studies retrieved from the databases of PubMed, SCOPUS, Google Scholar, Embase, Web of Science, and Cochrane up to March 2024. The results were analyzed following PRISMA guidelines. Six studies that compared the outcomes of patients receiving perioperative BiZact™ tonsillectomy with those in control groups (cold steel dissection or bipolar tonsillectomy) were included for this analysis of the outcomes, which included intraoperative bleeding and time, postoperative pain, and frequency of postoperative bleeding. Results: The operative time (SMD −11.5985, 95%CI [−20.3326; −2.8644], I2 = 99.5%) in the treatment group was significantly reduced compared to the control group. However, BiZact™ showed no significant efficacy in reducing intraoperative bleeding when compared with the control group (SMD −0.0480, 95%CI [−1.8200; 1.7240], I2 = 98.6%). Postoperative pain on day 1 (SMD −0.0885, 95%CI [−0.4368; 0.2598], I2 = 98.9%), day 3 (SMD −0.2118, 95%CI [−0.6110; 0.1873], I2 = 99.5%), and later than day 7 (SMD 0.0924, 95%CI [−0.2491; 0.4338], I2 = 98.6%) in the treatment group was not significantly reduced relative to the control group. When compared to the control group, BiZact™ did not reduce the incidence of secondary postoperative bleeding control in the operation room (OR 0.5711, 95%CI [0.2476; 1.3173], I2 = 32.1%), primary bleeding (OR 0.4514, 95%CI [0.0568; 3.5894], I2 = 0.0%), or all postoperative bleeding events (OR 0.8117, 95%CI [0.5796; 1.1368], I2 = 26.3%). Conclusions: This study demonstrated that using the BiZact™ device for tonsillectomy significantly decreased the operative time but could not effectively reduce intraoperative bleeding or postoperative pain and bleeding.
Effects of glossopharyngeal nerve block on pain control after tonsillectomy: a systemic review and meta‐analysis
AbstractBackgroundWe investigated the role of perioperative intraoral glossopharyngeal nerve block to minimize postoperative pain in patients undergoing tonsillectomy through a meta‐analysis of the relevant literature.MethodsWe retrieved eight studies from PubMed, Scopus, Embase, Web of Science, and Cochrane databases up to August 2023. We compared perioperative glossopharyngeal nerve block with a control group, in order to examine postoperative pain, analgesic use, and other postoperative morbidities.ResultsPostoperative pain was significantly reduced at 1–4 h (SMD −1.26, 95% CI [−2.35; −0.17], I2 = 94.7%, P = 0.02) and 5–8 hours (SMD −1.40, 95% CI [−2.47; −0.34], I2 = 96.1%, p = 0.01) in the treatment groups compared to the control group. However, glossopharyngeal nerve block showed no efficacy in reducing pain or use of analgesic drugs after 12 h compared to the control group. The incidences of postoperative bleeding (OR 0.95, 95% CI [0.35; 2.52], I2 = 0.0%), local agent toxicity (OR 4.14, 95% CI [0.44; 38.63], I2 = 0.0%), nasal problems (OR 1.25, 95% CI [0.60; 2.61], I2 = 0.0%), postoperative nausea and vomiting (OR 1.35, 95% CI [0.78; 2.33], I2 = 0.0%), swallowing difficulty (OR 1.61, 95% CI [0.76; 3.42], I2 = 56.0%), and voice change (OR 3.11, 95% CI [0.31; 30.80], I2 = 0.0%) were not significantly different between the treatment and control groups. The treatment group showed higher prevalence of respiratory problems and dry mouth compared to control without statistical significance, but a significant increase in throat discomfort (p = 0.02).ConclusionIntraoral glossopharyngeal nerve block for tonsillectomy did not significantly impact postoperative pain management and was associated with some adverse effects with increases in respiratory problems, dry mouth, and throat discomfort compared to controls.
Comparison of Liquid-Based Preparations with Conventional Smears in Thyroid Fine-Needle Aspirates: A Systematic Review and Meta-Analysis
Background: To compare conventional smears (CSs) and liquid-based preparations (LBPs) for diagnosing thyroid malignant or suspicious lesions. Methods: Studies in the PubMed, SCOPUS, Embase, Web of Science, and Cochrane database published up to December 2023. We reviewed 17 studies, including 15,861 samples. Results: The diagnostic odds ratio (DOR) for CS was 23.6674. The area under the summary receiver operating characteristic curve (AUC) was 0.879, with sensitivity, specificity, negative predictive value, and positive predictive value of 0.8266, 0.8668, 0.8969, and 0.7841, respectively. The rate of inadequate specimens was 0.1280. For LBP, the DOR was 25.3587, with an AUC of 0.865. The sensitivity, specificity, negative predictive value, and positive predictive value were 0.8190, 0.8833, 0.8515, and 0.8562. The rate of inadequate specimens was 0.1729. For CS plus LBP, the AUC was 0.813, with a lower DOR of 9.4557 compared to individual methods. Diagnostic accuracy did not significantly differ among CS, LBP, and CS plus LBP. Subgroup analysis was used to compare ThinPrep and SurePath. The DORs were 29.1494 and 19.7734. SurePath had a significantly higher AUC. Conclusions: There was no significant difference in diagnostic accuracy or proportion of inadequate smears between CS and LBP. SurePath demonstrated higher diagnostic accuracy than ThinPrep. Recommendations for fine-needle aspiration cytology should consider cost, feasibility, and accuracy.
Effectiveness of Radiofrequency Device Treatment for Nasal Valve Collapse in Patients With Nasal Obstruction
AbstractObjectiveInternal nasal valve dysfunction is a prevalent cause of nasal obstruction. This systematic review, along with a Meta‐analysis, evaluated the efficacy of temperature‐controlled radiofrequency device (RFD) treatment in alleviating nasal obstruction by rectifying nasal valve collapse.Data SourcesA comprehensive review of studies retrieved from PubMed, SCOPUS, Embase, Web of Science, and Cochrane databases (up to December 2022) was conducted.Review MethodsWe included studies that evaluated the quality of life and nasal obstruction scores before and after RFD treatment. In addition, sham‐controlled studies were analyzed.ResultsIn total, 451 patients across 8 studies were included in the analysis. Patients who underwent RFD treatment reported a significantly enhanced quality of life 24 months after treatment compared to pretreatment scores. The rates of clinically improved states and positive responses regarding quality of life after treatment were 82% and 91%, respectively. Moreover, the disease‐specific quality of life, as assessed by the Nasal Obstruction Symptom Evaluation score, significantly improved.ConclusionRFD may help improve nasal obstruction symptoms. Further randomized clinical studies on larger cohorts are essential to substantiate its efficacy in enhancing nasal valve function.
Diagnostic Performance of ACR and Kwak TI-RADS for Benign and Malignant Thyroid Nodules: An Update Systematic Review and Meta-Analysis
(1) Background: To determine the optimal cut-off values of two risk stratification systems to discriminate malignant thyroid nodules and to compare the diagnostic performance; (2) Methods: True and false positive and negative data were collected, and methodological quality was assessed for forty-six studies involving 39,085 patients; (3) Results: The highest area under the receiver operating characteristic (ROC) curve (AUC) of ACR and Kwak TI-RADS were 0.875 and 0.884. Based on the optimal sensitivity and specificity, the highest accuracy values of ROC curves or diagnostic odds ratios (DOR) were taken as the cut-off values for TR4 (moderate suspicious) and 4B. The sensitivity, specificity, DOR, and AUC by ACR (TR4) and Kwak TI-RADS (4B) for malignancy risk stratification of thyroid nodules were 94.3% and 96.4%; 52.2% and 53.7%; 17.5185 and 31.8051; 0.786 and 0.884, respectively. There were no significant differences in diagnostic accuracy in any of the direction comparisons of the two systems; (4) Conclusions: ACR and Kwak TI-RADS had good diagnostic performances (AUCs > 85%). Although we determined the best cut-off values in individual risk stratification systems based on statistical assessment, clinicians can adjust the optimal cut-off value according to the clinical purpose of the ultrasonography because raising or lowering cut-points leads to reciprocal changes in sensitivity and specificity.
Safety and Efficacy of Transoral Robotic Thyroidectomy for Thyroid Tumor: A Systematic Review and Meta-Analysis
Background: To assess the safety and effectiveness of transoral robotic thyroidectomy (TORT) in thyroid tumor. Methods: PubMed, Embase, Web of Science, SCOPUS, Cochrane database, and Google Scholar up to June 2022. Studies comparing outcomes and complications between TORT and control groups (robotic bilateral axillo-breast, trans-axillary, postauricular approach, conventional open thyroidectomy (OT), and transoral endoscopic approach) were analyzed. Results: Ten studies of 1420 individuals. The operative time (SMD 1.15, 95%CI [0.48; 1.89]) was significantly longer and the number of retrieved lymph nodes (LNs) (SMD −0.27, 95%CI [−0.39; −0.16]) was fewer in TORT than in the control group. The postoperative cosmetic satisfaction score (SMD 0.60, 95%CI [0.28; 0.92]) was statistically higher in TORT than in the control group. In subgroup analysis, there was no significant difference between robotic surgeries. However, TORT had significantly longer operative times (SMD 2.08, 95%CI [0.95; 3.20]) and fewer retrieved LNs (SMD −0.32, 95%CI [−0.46; −0.17]) than OT. TORT satisfied significantly more patients in cosmetic view. However, it increased hospitalization days and postoperative pain on the operation day and first day compared to OT. Conclusions: TORT is not inferior to other robotic-assisted approaches. Its operation time and hospitalization days are longer and postoperative pain is greater than OT, although its cosmetic satisfaction is high.