Back to Authors

Burri, Haran

https://orcid.org/0000-0002-4393-5338

Mayo Clinic

University Hospital of Geneva

Citations 2

Conduction system vs. biventricular pacing in heart failure with reduced ejection fraction: a meta-analysis of randomized controlled trials
Karakasis, Paschalis , Vlachos, Konstantinos , Siontis, Konstantinos C. , Cano, Óscar , Tzeis, Stylianos , Strik, Marc , Pamporis, Konstantinos , Leventopoulos, Georgios , Antoniadis, Antonios P. , Jaı̈s, Pierre , Burri, Haran , Fragakis, Nikolaos , Karakasis, Paschalis , Pamporis, Konstantinos , Antoniadis, Antonios P , Jaïs, Pierre , Burri, Haran

Europace | July 1, 2026 | Volume: 28 | Issue: 8 | Pages: No page available

10.1093/europace/euag170 Get It

Abstract Aims Conduction system pacing (CSP) has emerged as a physiologic alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BiVP) in heart failure with reduced ejection fraction (HFrEF), yet its comparative effects remain uncertain. This meta-analysis sought to compare outcomes of CSP vs. BiVP in patients with HFrEF undergoing CRT. Methods and results MEDLINE, Embase, Scopus, and the Cochrane Database were searched through 4 May 2026. Randomized controlled trials (RCTs) were synthesized using random-effects meta-analysis. Thirteen RCTs including 1320 participants were analysed (657 CSP, 663 BiVP). Conduction system pacing was associated with a lower risk of the composite of hospitalization for heart failure (HHF) or all-cause mortality compared with BiVP (46 vs. 83 events; odds ratio [OR] 0.51, 95% confidence interval [CI] 0.28–0.93). No significant differences were observed for HHF alone (OR 0.68, 95% CI 0.36–1.27) or all-cause mortality (OR 0.75, 95% CI 0.36–1.58). Conduction system pacing was associated with greater improvement in the 6-min walk distance (mean difference [MD] 21.53 m, 95% CI 4.33–38.73) and New York Heart Association functional class (standardized mean difference [SMD] −0.27, 95% CI −0.47 to −0.07), but not quality of life. Conduction system pacing also reduced QRS duration compared with BiVP (MD −10.94 ms, 95% CI −17.55 to −4.34), with no significant differences in left ventricular ejection fraction, left ventricular end-systolic volume, overall pacing threshold, total procedure time, fluoroscopy time, any complication, or reintervention. Conclusion In patients with HFrEF undergoing CRT, CSP is associated with lower composite risk of HHF or all-cause mortality compared with BiVP. Conduction system pacing is also associated with improved functional capacity, without significant differences in safety or procedural outcomes.