Back to Authors

Pamporis, Konstantinos

0000-0001-5411-6461

Mayo Clinic

National and Kapodistrian University of Athens

Citations 2

Conduction system vs. biventricular pacing in heart failure with reduced ejection fraction: a meta-analysis of randomized controlled trials
Karakasis, Paschalis , Vlachos, Konstantinos , Siontis, Konstantinos C. , Cano, Óscar , Tzeis, Stylianos , Strik, Marc , Pamporis, Konstantinos , Leventopoulos, Georgios , Antoniadis, Antonios P. , Jaı̈s, Pierre , Burri, Haran , Fragakis, Nikolaos , Karakasis, Paschalis , Pamporis, Konstantinos , Antoniadis, Antonios P , Jaïs, Pierre , Burri, Haran

Europace | July 1, 2026 | Volume: 28 | Issue: 8 | Pages: No page available

10.1093/europace/euag170 Get It

Abstract Aims Conduction system pacing (CSP) has emerged as a physiologic alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BiVP) in heart failure with reduced ejection fraction (HFrEF), yet its comparative effects remain uncertain. This meta-analysis sought to compare outcomes of CSP vs. BiVP in patients with HFrEF undergoing CRT. Methods and results MEDLINE, Embase, Scopus, and the Cochrane Database were searched through 4 May 2026. Randomized controlled trials (RCTs) were synthesized using random-effects meta-analysis. Thirteen RCTs including 1320 participants were analysed (657 CSP, 663 BiVP). Conduction system pacing was associated with a lower risk of the composite of hospitalization for heart failure (HHF) or all-cause mortality compared with BiVP (46 vs. 83 events; odds ratio [OR] 0.51, 95% confidence interval [CI] 0.28–0.93). No significant differences were observed for HHF alone (OR 0.68, 95% CI 0.36–1.27) or all-cause mortality (OR 0.75, 95% CI 0.36–1.58). Conduction system pacing was associated with greater improvement in the 6-min walk distance (mean difference [MD] 21.53 m, 95% CI 4.33–38.73) and New York Heart Association functional class (standardized mean difference [SMD] −0.27, 95% CI −0.47 to −0.07), but not quality of life. Conduction system pacing also reduced QRS duration compared with BiVP (MD −10.94 ms, 95% CI −17.55 to −4.34), with no significant differences in left ventricular ejection fraction, left ventricular end-systolic volume, overall pacing threshold, total procedure time, fluoroscopy time, any complication, or reintervention. Conclusion In patients with HFrEF undergoing CRT, CSP is associated with lower composite risk of HHF or all-cause mortality compared with BiVP. Conduction system pacing is also associated with improved functional capacity, without significant differences in safety or procedural outcomes.
Safety and efficacy of intracardiac echocardiography in atrial fibrillation ablation: a meta-analysis
Karakasis, Paschalis , Tzeis, Stylianos , Pamporis, Konstantinos , Vlachos, Konstantinos , Siontis, Konstantinos C, Antoniadis, Antonios P , Bénali, Karim , Theofilis, Panagiotis null, Tsiachris, Dimitris , Chun, Julian, Jaïs, Pierre , Fragakis, Nikolaos, Karakasis, Paschalis , Pamporis, Konstantinos , Antoniadis, Antonios P. , Siontis, Konstantinos C , Theofilis, Panagiotis , Tsiachris, Dimitrios , Chun, Julian K R , Fragakis, Nikolaos , Tzeis, Stylianos , Siontis, Konstantinos C. , Benali, Karim , Jaı̈s, Pierre

Europace | January 8, 2026 | Volume: 28 | Issue: 2 | Pages: No page available

10.1093/europace/euag002 Get It

Abstract Aims Intracardiac echocardiography (ICE) is increasingly incorporated into atrial fibrillation (AF) ablation workflows, enabling real-time anatomic guidance and procedural precision. Nevertheless, ICE utilization shows substantial geographic variability, and its clinical benefit remains incompletely understood. This meta-analysis evaluated the efficacy, safety, and procedural performance of ICE-guided vs. non-ICE-guided AF ablation. Methods and results MEDLINE, the Cochrane Library, and Scopus were systematically searched through 3 August 2025. Three reviewers independently performed study selection, data extraction, and risk-of-bias assessment. Random-effects models were used to pool data from 44 AF ablation studies comprising 482 043 patients. ICE guidance was associated with lower odds of any complication (OR 0.69; 95% CI 0.53–0.89), including significant reductions in cardiac tamponade (OR 0.58; 95% CI 0.53–0.62) and mortality (OR 0.21; 95% CI 0.16–0.27). ICE-guided ablation was also associated with shorter total procedure and fluoroscopy times, reduced radiation exposure, and lower contrast agent utilization. Atrial tachyarrhythmia (AT) recurrence did not differ between groups (OR 0.92; 95% CI 0.79–1.06). However, ICE use was associated with higher odds of first-pass pulmonary vein isolation (OR 1.62; 95% CI 1.09–2.41) and successful isolation of all pulmonary veins at the end of the procedure (OR 2.12; 95% CI 1.37–3.27), and lower odds of repeat ablation (OR 0.65; 95% CI 0.59–0.72). Conclusion ICE-guided AF ablation is associated with superior procedural safety and efficiency and a similar risk of AT recurrence compared to non-ICE-guided approaches.