Back to Authors

Gelston, Suzanne

0000-0001-6853-8067

Mayo Clinic

Washington State University

Citations 5

HOCl-producing electrochemical bandage is active in murine polymicrobial wound infection
Fleming, Derek , Bozyel, Ibrahim , Koscianski, Christina, Ozdemir, Dilara , Karau, Melissa J. , Cuello, Luz , Anoy, Md Monzurul Islam , Gelston, Suzanne , Schuetz, Audrey N. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Koscianski, Christina A, Beyenal, H , Patel, Robin , Schuetz, Audrey N , Fleming, Derek , Beyenal, Haluk , Patel, Robin

Microbiology Spectrum | August 20, 2024 | Volume: 12 | Issue: 10 | Pages: No page available

10.1128/spectrum.00626-24 Get It

ABSTRACT Wound infections, exacerbated by the prevalence of antibiotic-resistant bacterial pathogens, necessitate innovative antimicrobial approaches. Polymicrobial infections, often involving Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus (MRSA), present challenges due to biofilm formation and antibiotic resistance. Hypochlorous acid (HOCl), a potent antimicrobial agent, holds promise as an alternative therapy. An electrochemical bandage (e-bandage) that generates HOCl in situ via precise polarization controlled by a miniaturized potentiostat was evaluated for the treatment of murine wound biofilm infections containing both P. aeruginosa with “difficult-to-treat” resistance and MRSA. Previously, HOCl-producing e-bandage was shown to reduce murine wound biofilms containing P. aeruginosa alone. Here, in 5-mm excisional skin wounds containing 48-h biofilms comprising MRSA and P. aeruginosa combined, polarized e-bandage treatment reduced MRSA by 1.1 log 10 CFU/g ( P = 0.026) vs non-polarized e-bandage treatment (no HOCl production), and 1.4 log 10 CFU/g (0.0015) vs Tegaderm only controls; P. aeruginosa was similarly reduced by 1.6 log 10 CFU/g ( P = 0.0032) and 1.6 log 10 CFU/g ( P = 0.0015), respectively. For wounds infected with MRSA alone, polarized e-bandage treatment reduced bacterial load by 1.1 log 10 CFU/g ( P = 0.0048) and 1.3 log 10 CFU/g ( P = 0.0048) compared with non-polarized e-bandage and Tegaderm only, respectively. The e-bandage treatment did not negatively impact wound healing or cause tissue toxicity. The addition of systemic antibiotics did not enhance the antimicrobial efficacy of e-bandages. This study provides additional evidence for the HOCl-producing e-bandage as a novel antimicrobial strategy for managing wound infections, including in the context of antibiotic resistance and polymicrobial infections. IMPORTANCE New approaches are needed to combat the rise of antimicrobial-resistant infections. The HOCl-producing electrochemical bandage (e-bandage) leverages in situ generation of HOCl, a natural biocide, for broad-spectrum killing of wound pathogens. Unlike traditional therapies that may exhibit limited activity against biofilms and antimicrobial-resistant organisms, the e-bandage offers a potent, standalone solution that does not contribute to further resistance or require adjunctive antibiotic therapy. Here, we show the ability of the e-bandage to address polymicrobial infection by antimicrobial resistant clinical isolates of Staphylococcus aureus and Pseudomonas aeruginosa , two commonly isolated, co-infecting wound pathogens. Effectiveness of the HOCl-producing e-bandage in reducing pathogen load while minimizing tissue toxicity and avoiding the need for systemic antibiotics underscores its potential as a tool in managing complex wound infections.
Evaluation of treatment of methicillin-resistant Staphylococcus aureus biofilms with intermittent electrochemically generated H 2 O 2 or HOCl
Anoy, Md Monzurul Islam , Kim, Won‐Jun , Gelston, Suzanne , Fleming, Derek , Patel, Robin , Beyenal, Haluk , Patel, Robin , Beyenal, H , Fleming, Derek , Kim, Won-Jun

Antimicrobial Agents and Chemotherapy | May 21, 2024 | Volume: 68 | Issue: 7 | Pages: No page available

10.1128/aac.01722-23 Get It

ABSTRACT Chronic wound infections can be difficult to treat and may lead to impaired healing and worsened patient outcomes. Novel treatment strategies are needed. This study evaluated the effects of intermittently produced hydrogen peroxide (H 2 O 2 ) and hypochlorous acid (HOCl), generated via an electrochemical bandage (e-bandage), against methicillin-resistant Staphylococcus aureus biofilms in an agar membrane biofilm model. By changing the working electrode potential, the e-bandage generated either HOCl (1.5 V Ag/AgCl ) or H 2 O 2 (−0.6 V Ag/AgCl ). The degree of biocidal activity of intermittent treatment with HOCl and H 2 O 2 correlated with HOCl treatment time; HOCl treatment durations of 0, 1.5, 3, 4.5, and 6 hours (with the rest of the 6-hour total treatment time devoted to H 2 O 2 generation) resulted in mean biofilm reductions of 1.36 ± 0.2, 2.22 ± 0.16, 3.46 ± 0.38, 4.63 ± 0.74, and 7.66 ± 0.5 log CFU/cm 2 , respectively, vs. non-polarized controls, respectively. However, application of H 2 O 2 immediately after HOCl treatment was detrimental to biofilm removal. For example, 3 hours HOCl treatment followed by 3 hours H 2 O 2 resulted in a 1.90 ± 0.84 log CFU/cm 2 lower mean biofilm reduction than 3 hours HOCl treatment followed by 3 hours non-polarization. HOCl generated over 3 hours exhibited biocidal activity for at least 7.5 hours after e-bandage operation ceased; 3 hours of HOCl generation followed by 7.5 hours of non-polarization resulted in a biofilm cell reduction of 7.92 ± 0.12 log CFU/cm 2 vs. non-polarized controls. Finally, intermittent treatment with HOCl (i.e., interspersed with periods of e-bandage non-polarization) for various intervals showed similar effects (approximately 6 log CFU/cm 2 reduction vs. non-polarized control) to continuous treatment with HOCl for 3 hours, followed by 3 hours of non-polarization. These findings suggest that timing and sequencing of HOCl and H 2 O 2 treatments are crucial for maximizing biofilm control when using an e-bandage strategy.
Antibiofilm Activity of a Tunable Hypochlorous Acid‐Generating Electrochemical Bandage Controlled by a Wearable Potentiostat
Raval, Yash S. , Gelston, Suzanne , Tibbits, Gretchen , Flurin, Laure , Greenwood‐Quaintance, Kerryl E. , Patel, Robin , Beyenal, Haluk , Patel, Robin , Beyenal, H , Greenwood-Quaintance, Kerryl , Raval, Yash S. , Mohamed, Abdelrhman , Ay, Suat Utku

Advanced Engineering Materials | October 26, 2022 | Volume: 25 | Issue: 1 | Pages: No page available

10.1002/adem.202200792 Get It

Chronic wound biofilm infections represent a major clinical challenge which results in a substantial burden to patients and healthcare systems. Treatment with topical antibiotics is oftentimes ineffective as a result of antibiotic‐resistant microorganisms and biofilm‐specific antibiotic tolerance. Use of biocides such as hypochlorous acid (HOCl) has gained increasing attention due to the lack of known resistance mechanisms. An HOCl‐generating electrochemical bandage (e‐bandage) is designed that delivers HOCl continuously at low concentrations targeting infected wound beds in a similar manner to adhesive antimicrobial wound dressings. A battery‐operated wearable potentiostat is developed that controls the e‐bandage electrodes at potentials suitable for HOCl generation. It is demonstrated that e‐bandage treatment is tunable by changing the applied potential. HOCl generation on electrode surfaces is verified using microelectrodes. The developed e‐bandage shows time‐dependent responses against in vitro Acinetobacter baumannii and Staphylococcus aureus biofilms, reducing viable cells to nondetectable levels within 6 and 12 h of treatment, respectively. The developed e‐bandage should be further evaluated as an alternative to topical antibiotics to treat wound biofilm infections.
Activity of a hypochlorous acid‐producing electrochemical bandage as assessed with a porcine explant biofilm model
Tibbits, Gretchen , Mohamed, Abdelrhman , Gelston, Suzanne , Flurin, Laure , Raval, Yash S. , Greenwood‐Quaintance, Kerryl E. , Patel, Robin , Beyenal, Haluk , Patel, Robin , Mohamed, A , Beyenal, H , Greenwood-Quaintance, Kerryl , Raval, Yash S.

Biotechnology and Bioengineering | September 28, 2022 | Volume: 120 | Issue: 1 | Pages: 250-259

10.1002/bit.28248 Get It

AbstractThe activity of a hypochlorous acid‐producing electrochemical bandage (e‐bandage) in preventing methicillin‐resistant Staphylococcus aureus infection (MRSA) infection and removing biofilms formed by MRSA was assessed using a porcine explant biofilm model. e‐Bandages inhibited S. aureus infection (p = 0.029) after 12 h (h) of exposure and reduced 3‐day biofilm viable cell counts after 6, 12, and 24 h exposures (p = 0.029). Needle‐type microelectrodes were used to assess HOCl concentrations in explant tissue as a result of e‐bandage treatment; toxicity associated with e‐bandage treatment was evaluated. HOCl concentrations in infected and uninfected explant tissue varied between 30 and 80 µM, decreasing with increasing distance from the e‐bandage. Eukaryotic cell viability was reduced by an average of 71% and 65% in fresh and day 3‐old explants, respectively, when compared to explants exposed to nonpolarized e‐bandages. HOCl e‐bandages are a promising technology that can be further developed as an antibiotic‐free treatment for wound biofilm infections.
Efficacy and toxicity of hydrogen peroxide producing electrochemical bandages in a porcine explant biofilm model
Tibbits, Gretchen , Mohamed, Abdelrhman , Gelston, Suzanne , Flurin, Laure , Raval, Yash S. , Greenwood‐Quaintance, Kerryl E. , Patel, Robin , Beyenal, Haluk , Greenwood-Quaintance, Kerryl , Patel, Robin , Mohamed, A , Beyenal, H , Raval, Yash S.

Journal of Applied Microbiology | September 8, 2022 | Volume: 133 | Issue: 6 | Pages: 3755-3767

10.1111/jam.15812 Get It

Abstract Aims Effects of H2O2 producing electrochemical-bandages (e-bandages) on methicillin-resistant Staphylococcus aureus colonization and biofilm removal were assessed using a porcine explant biofilm model. Transport of H2O2 produced from the e-bandage into explant tissue and associated potential toxicity were evaluated. Methods and Results Viable prokaryotic cells from infected explants were quantified after 48 h treatment with e-bandages in three ex vivo S. aureus infection models: (1) reducing colonization, (2) removing young biofilms and (3) removing mature biofilms. H2O2 concentration-depth profiles in explants/biofilms were measured using microelectrodes. Reductions in eukaryotic cell viability of polarized and nonpolarized noninfected explants were compared. e-Bandages effectively reduced S. aureus colonization (p = 0.029) and reduced the viable prokaryotic cell concentrations of young biofilms (p = 0.029) with limited effects on mature biofilms (p > 0.1). H2O2 penetrated biofilms and explants and reduced eukaryotic cell viability by 32–44% compared to nonpolarized explants. Conclusions H2O2 producing e-bandages were most active when used to reduce colonization and remove young biofilms rather than to remove mature biofilms. Significance and Impact of Study The described e-bandages reduced S. aureus colonization and young S. aureus biofilms in a porcine explant wound model, supporting their further development as an antibiotic-free alternative for managing biofilm infections.