Chronic wound biofilm infections represent a major clinical challenge which results in a substantial burden to patients and healthcare systems. Treatment with topical antibiotics is oftentimes ineffective as a result of antibiotic‐resistant microorganisms and biofilm‐specific antibiotic tolerance. Use of biocides such as hypochlorous acid (HOCl) has gained increasing attention due to the lack of known resistance mechanisms. An HOCl‐generating electrochemical bandage (e‐bandage) is designed that delivers HOCl continuously at low concentrations targeting infected wound beds in a similar manner to adhesive antimicrobial wound dressings. A battery‐operated wearable potentiostat is developed that controls the e‐bandage electrodes at potentials suitable for HOCl generation. It is demonstrated that e‐bandage treatment is tunable by changing the applied potential. HOCl generation on electrode surfaces is verified using microelectrodes. The developed e‐bandage shows time‐dependent responses against in vitro Acinetobacter baumannii and Staphylococcus aureus biofilms, reducing viable cells to nondetectable levels within 6 and 12 h of treatment, respectively. The developed e‐bandage should be further evaluated as an alternative to topical antibiotics to treat wound biofilm infections.
Activity of a hypochlorous acid‐producing electrochemical bandage as assessed with a porcine explant biofilm model
AbstractThe activity of a hypochlorous acid‐producing electrochemical bandage (e‐bandage) in preventing methicillin‐resistant Staphylococcus aureus infection (MRSA) infection and removing biofilms formed by MRSA was assessed using a porcine explant biofilm model. e‐Bandages inhibited S. aureus infection (p = 0.029) after 12 h (h) of exposure and reduced 3‐day biofilm viable cell counts after 6, 12, and 24 h exposures (p = 0.029). Needle‐type microelectrodes were used to assess HOCl concentrations in explant tissue as a result of e‐bandage treatment; toxicity associated with e‐bandage treatment was evaluated. HOCl concentrations in infected and uninfected explant tissue varied between 30 and 80 µM, decreasing with increasing distance from the e‐bandage. Eukaryotic cell viability was reduced by an average of 71% and 65% in fresh and day 3‐old explants, respectively, when compared to explants exposed to nonpolarized e‐bandages. HOCl e‐bandages are a promising technology that can be further developed as an antibiotic‐free treatment for wound biofilm infections.
Efficacy and toxicity of hydrogen peroxide producing electrochemical bandages in a porcine explant biofilm model
Abstract Aims Effects of H2O2 producing electrochemical-bandages (e-bandages) on methicillin-resistant Staphylococcus aureus colonization and biofilm removal were assessed using a porcine explant biofilm model. Transport of H2O2 produced from the e-bandage into explant tissue and associated potential toxicity were evaluated. Methods and Results Viable prokaryotic cells from infected explants were quantified after 48 h treatment with e-bandages in three ex vivo S. aureus infection models: (1) reducing colonization, (2) removing young biofilms and (3) removing mature biofilms. H2O2 concentration-depth profiles in explants/biofilms were measured using microelectrodes. Reductions in eukaryotic cell viability of polarized and nonpolarized noninfected explants were compared. e-Bandages effectively reduced S. aureus colonization (p = 0.029) and reduced the viable prokaryotic cell concentrations of young biofilms (p = 0.029) with limited effects on mature biofilms (p > 0.1). H2O2 penetrated biofilms and explants and reduced eukaryotic cell viability by 32–44% compared to nonpolarized explants. Conclusions H2O2 producing e-bandages were most active when used to reduce colonization and remove young biofilms rather than to remove mature biofilms. Significance and Impact of Study The described e-bandages reduced S. aureus colonization and young S. aureus biofilms in a porcine explant wound model, supporting their further development as an antibiotic-free alternative for managing biofilm infections.
Hydrogen peroxide‐producing electrochemical bandage controlled by a wearable potentiostat for treatment of wound infections
AbstractChronic wound infections caused by biofilm‐forming microorganisms represent a major burden to healthcare systems. Treatment of chronic wound infections using conventional antibiotics is often ineffective due to the presence of bacteria with acquired antibiotic resistance and biofilm‐associated antibiotic tolerance. We previously developed an electrochemical scaffold that generates hydrogen peroxide (H2O2) at low concentrations in the vicinity of biofilms. The goal of this study was to transition our electrochemical scaffold into an H2O2‐generating electrochemical bandage (e‐bandage) that can be used in vivo. The developed e‐bandage uses a xanthan gum‐based hydrogel to maintain electrolytic conductivity between e‐bandage electrodes and biofilms. The e‐bandage is controlled using a lightweight, battery‐powered wearable potentiostat suitable for use in animal experiments. We show that e‐bandage treatment reduced colony‐forming units of Acinetobacter buamannii biofilms (treatment vs. control) in 12 h (7.32 ± 1.70 vs. 9.73 ± 0.09 log10[CFU/cm2]) and 24 h (4.10 ± 12.64 vs. 9.78 ± 0.08 log10[CFU/cm2]) treatments, with 48 h treatment reducing viable cells below the limit of detection of quantitative and broth cultures. The developed H2O2‐generating e‐bandage was effective against in vitro A. baumannii biofilms and should be further evaluated and developed as a potential alternative to topical antibiotic treatment of wound infections.