BACKGROUND The implications of hypotension occurring during dobutamine stress echocardiography have not been elucidated. We observed in some patients that hyperdynamic left ventricular function developed during dobutamine stress echocardiography and hypothesized that intracavitary obstruction was occurring and might account for hypotension in some patients. METHODS AND RESULTS Fifty-seven consecutive patients undergoing dobutamine stress echocardiography underwent pulsed-wave and continuous-wave Doppler examination of the left ventricular cavity at rest and at peak dobutamine infusion. The development of an intraventricular gradient with dobutamine stress was defined as a late-peaking left ventricular Doppler velocity profile that exceeded basal velocity by at least 1 m/sec. During dobutamine stress testing, left ventricular outflow velocity or intracavitary velocity increased in all patients. Obstruction occurred in 12 patients (21%, group 1). Group 2 was the remaining 45 patients. Peak velocities in group 1 ranged from 2.0 to 5.0 m/sec (mean, 3.5 m/sec), and the mean increase from velocity at rest was 2.3 m/sec. The mean change in systolic blood pressure was significantly lower in patients in group 1 (-15 versus 4 mm Hg, p = 0.02). When the 18 patients with an ischemic response to stress testing (evidenced by new or worsening wall motion abnormalities) were excluded from analysis, systolic blood pressure response was still significantly different for the two groups (-19 versus 2 mm Hg, p = 0.03). CONCLUSIONS Dynamic left ventricular obstruction is a new observation; it may develop frequently in patients undergoing dobutamine stress echocardiography. Obstruction rather than ischemia may explain a decrease in blood pressure during dobutamine stress echocardiography.
Echocardiographic Pattern of Right Ventricular Diastolic Volume Overload in Children
Echocardiograms were performed on 20 children who were 1-14 years old. Ten children had secundum atrial septal defects (ASD 2°); four had partial and two had complete atrioventricular canal defects (AVC); and three had partial and one had total anomalous pulmonary venous connection (APVC). Twenty-eight normal children were also examined. Echocardiograms of nine patients with ASD 2° revealed increased right ventricular dimension index (RVDI) and abnormal (paradoxic) ventricular septal (VS) motion. The remaining patient with ASD 2°, who had a Qp/Qs of 1.2 (smallest in the series), had a normal echocardiogram. All four patients with APVC had increased RVDI, and three had abnormal VS motion. The patient with normal septal motion had associated mild aortic stenosis, but he too had a small left-to-right shunt (19%). The echocardiograms of two patients with partial AVC revealed features similar to ASD 2°, but in the third patient who had significant mitral regurgitation (MR) the VS motion was normal, indicating that the degree of associated MR influences the VS motion in this anomaly. The septal motion was normal in both patients with complete AVC. Three patients in the series had abnormal systolic anterior motion of mitral valve. Postoperative echocardiograms revealed persistence of increased RVDI and "paradoxic" VS motion.
Constrictive Pericarditis and Restrictive Cardiomyopathy in the Modern Era
It has previously been demonstrated that predictable changes occur in mitral flow velocities under different loading conditions. The purpose of this study was to relate changes in pulmonary venous and mitral flow velocities during different loading conditions as assessed by transesophageal echocardiography in the operating room. Nineteen patients had measurements of hemodynamics, that is, mitral and pulmonary vein flow velocities during the control situation, a decrease in preload by administration of nitroglycerin, an increase in preload by administration of fluids, and an increase in afterload by infusion of phenylephrine. There was a direct correlation between the changes in the mitral E velocity and the early peak diastolic velocity in the pulmonary vein curves (r = 0.61) as well as a direct correlation between the deceleration time of the mitral and pulmonary venous flow velocities in early diastole (r = 0.84). This indicates that diastolic flow velocity in the pulmonary vein is determined by the same factors that influence the mitral flow velocity curves. A decrease in preload caused a significant reduction in the initial E velocity and prolongation of deceleration time, and an increase in preload caused an increase in E velocity and shortening of deceleration time. An increase in afterload produced a variable effect on the initial E velocity and deceleration time and was dependent on the left ventricular filling pressure. The change in systolic forward flow velocity in the pulmonary vein was directly proportional to the change in cardiac output (r = 0.60). The pulmonary capillary wedge pressure correlated best with the flow velocity reversal in the pulmonary vein at atrial contraction (r = 0.81). Use of pulmonary vein velocities in conjunction with mitral flow velocities can help in understanding left ventricular filling.
Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.
Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valves (20 aortic, 20 mitral, one tricuspid, and one pulmonary) were studied. Catheter gradients were obtained using a dual-catheter technique. The simultaneous pressure tracings and Doppler flow velocity profiles were digitized at 10-msec intervals to derive the corresponding maximal and mean gradients. The correlation between the maximal Doppler gradient and the simultaneously measured maximal catheter gradient was 0.94 (SEE = 6), and that between the Doppler gradient and the simultaneously measured mean catheter gradient was 0.96 (SEE = 3). There were no significant differences in correlation between gradients for the 32 mechanical valves (maximal gradients: r = 0.95, SEE = 6; mean gradients: r = 0.96, SEE = 3) and the 10 bioprosthetic valves (maximal gradients: r = 0.89, SEE = 6; mean gradients: r = 0.93, SEE = 3). In patients with mitral prostheses, Doppler gradients correlated well with the corresponding catheter gradients obtained with direct measurement of left atrial pressure (maximal gradients: r = 0.96, SEE = 2; mean gradients: r = 0.97, SEE = 1.2). A close correlation between corresponding Doppler and catheter gradients also was found in patients with aortic prostheses (maximal gradients: r = 0.94, SEE = 6; mean gradients: r = 0.94, SEE = 3). Thus, continuous wave Doppler echocardiography can accurately predict the pressure gradient across prosthetic valves.
Doppler evaluation of results of percutaneous aortic balloon valvuloplasty in calcific aortic stenosis.
To evaluate the short-term results of percutaneous aortic balloon valvuloplasty, 55 consecutive elderly patients with symptomatic, severe aortic stenosis who were at high risk for surgical intervention underwent the procedure, with follow-up by clinical evaluation and Doppler echocardiography. Over a mean follow-up of 6.2 months, there were three early deaths (less than 30 days) and eight late deaths. Nine patients underwent subsequent aortic valve surgery, and four had repeat balloon valvuloplasty. Doppler echocardiography revealed a reduction in aortic valve mean gradient from 48 +/- 18 to 33 +/- 12 mm Hg after the procedure (p less than 0.0001) but a return to 46 +/- 16 mm Hg at follow-up (p less than 0.05). The aortic valve area increased from 0.54 +/- 0.15 to 0.85 +/- 0.23 cm2 after the procedure (p less than 0.0001), but there was a significant decrease to 0.67 +/- 0.19 cm2 at follow-up (p less than 0.05). Of patients free of aortic valve operation or death after 30 days after the procedure, 76% were severely symptomatic before the procedure as compared with 38% at follow-up. In patients undergoing percutaneous aortic balloon valvuloplasty, there is a continued high short-term mortality and a significant incidence of restenosis over short-term follow-up. Nonetheless, a subset of patients do experience sustained clinical improvement from this procedure.
Characteristics and Clinical Significance of Late Gadolinium Enhancement by Contrast-Enhanced Magnetic Resonance Imaging in Patients With Hypertrophic Cardiomyopathy
Background— Myocardial late gadolinium enhancement (LGE) on contrast-enhanced magnetic resonance imaging (CE-MRI) of patients with hypertrophic cardiomyopathy (HCM) has been suggested to represent intramyocardial fibrosis and, as such, an adverse prognostic risk factor. We evaluated the characteristics of LGE on CE-MRI and explored whether LGE among patients with HCM was associated with genetic testing, severe symptoms, ventricular arrhythmias, or sudden cardiac death (SCD). Methods and Results— Four hundred twenty-four patients with HCM (age=55±16 years [range 2 to 90], 41% females), without a history of septal ablation/myectomy, underwent CE-MRI (GE 1.5 Tesla). We evaluated the relation between LGE and HCM genes status, severity of symptoms, and the degree of ventricular ectopy on Holter ECG. Subsequent SCD and appropriate implanted cardioverter defibrillator (ICD) therapies were recorded during a mean follow-up of 43±14 months (range 16 to 94). Two hundred thirty-nine patients (56%) had LGE on CE-MRI, ranging from 0.4% to 65% of the left ventricle. Gene-positive patients were more likely to have LGE ( P <0.001). The frequencies of New York Heart Association class ≥3 dyspnea and angina class ≥3 were similar in patients with and without LGE (125 of 239 [52%] versus 94 of 185 [51%] and 24 of 239 [10%] versus 18 of 185 [10%], respectively, P =NS). LGE-positive patients were more likely to have episodes of nonsustained ventricular tachycardia (34 of 126 [27%] versus 8 of 94 [8.5%], P <0.001), had more episodes of nonsustained ventricular tachycardia per patient (4.5±12 versus 1.1±0.3, P =0.04), and had higher frequency of ventricular extrasystoles/24 hours (700±2080 versus 103±460, P =0.003). During follow-up, SCD occurred in 4 patients, and additional 4 patients received appropriate ICD discharges. All 8 patients were LGE positive (event rate of 0.94%/y, P =0.01 versus LGE negative). Two additional heart failure-related deaths were recorded among LGE-positive patients. Univariate associates of SCD or appropriate ICD discharge were positive LGE ( P =0.002) and presence of nonsustained ventricular tachycardia ( P =0.04). The association of LGE with events remained significant after controlling for other risk factors. Conclusions— In patients with HCM, presence of LGE on CE-MRI was common and more prevalent among gene-positive patients. LGE was not associated with severe symptoms. However, LGE was strongly associated with surrogates of arrhythmia and remained a significant associate of subsequent SCD and/or ICD discharge after controlling for other variables. If replicated, LGE may be considered an important risk factor for sudden death in patients with HCM.
Background— Bicuspid aortic valve is frequent and is reported to cause numerous complications, but the clinical outcome of patients diagnosed with normal or mildly dysfunctional valve is undefined. Methods and Results— In 212 asymptomatic community residents from Olmsted County, Minn (age, 32±20 years; 65% male), bicuspid aortic valve was diagnosed between 1980 and 1999 with ejection fraction ≥50% and aortic regurgitation or stenosis, absent or mild. Aortic valve degeneration at diagnosis was scored echocardiographically for calcification, thickening, and mobility reduction (0 to 3 each), with scores ranging from 0 to 9. At diagnosis, ejection fraction was 63±5% and left ventricular diameter was 48±9 mm. Survival 20 years after diagnosis was 90±3%, identical to the general population ( P =0.72). Twenty years after diagnosis, heart failure, new cardiac symptoms, and cardiovascular medical events occurred in 7±2%, 26±4%, and 33±5%, respectively. Twenty years after diagnosis, aortic valve surgery, ascending aortic surgery, or any cardiovascular surgery was required in 24±4%, 5±2%, and 27±4% at a younger age than the general population ( P <0.0001). No aortic dissection occurred. Thus, cardiovascular medical or surgical events occurred in 42±5% 20 years after diagnosis. Independent predictors of cardiovascular events were age ≥50 years (risk ratio, 3.0; 95% confidence interval, 1.5 to 5.7; P <0.01) and valve degeneration at diagnosis (risk ratio, 2.4; 95% confidence interval, 1.2 to 4.5; P =0.016; >70% events at 20 years). Baseline ascending aorta ≥40 mm independently predicted surgery for aorta dilatation (risk ratio, 10.8; 95% confidence interval, 1.8 to 77.3; P <0.01). Conclusions— In the community, asymptomatic patients with bicuspid aortic valve and no or minimal hemodynamic abnormality enjoy excellent long-term survival but incur frequent cardiovascular events, particularly with progressive valve dysfunction. Echocardiographic valve degeneration at diagnosis separates higher-risk patients who require regular assessment from lower-risk patients who require only episodic follow-up.
Background The early diastolic velocity of the mitral annulus (E′) is reduced in patients with diastolic dysfunction and increased filling pressures. Because transmitral inflow early velocity (E) increases progressively with higher filling pressures, E/E′ has been shown to have a strong positive relationship with pulmonary capillary wedge pressure (PCWP) and left ventricular end-diastolic pressure. However, previous studies have primarily involved patients without a pericardial abnormality. In constrictive pericarditis (CP), E′ is not reduced, despite increased filling pressures. This study evaluated the relationship between E/E′ and PCWP in patients with CP. Methods and Results We studied 10 patients (8 men; mean age, 64±7 years) with surgically confirmed CP. Doppler echocardiography was performed to measure early and late diastolic transmitral flow velocities. Tissue Doppler echocardiography was performed to measure E′. PCWP was measured with right heart catheterization. All patients were in sinus rhythm. Mean E and E′ were 91±15 cm/s and 11±4 cm/s, respectively. Mean PCWP was 25±6 mm Hg. E′ was positively correlated with PCWP ( r =0.69, P =0.027). There was a significant inverse correlation between E/E′ and PCWP ( r =−0.74, P =0.014). Despite high left ventricular filling pressures, E/E′ (mean, 9±4) was <15 in all but 1 patient. Conclusions Paradoxical to the positive correlation between E/E′ and PCWP in patients with myocardial disease, an inverse relationship was found in patients with CP.