Background— Percutaneous repair has emerged as a potential therapy for patients with prosthetic paravalvular regurgitation. However, there is a relative paucity of data on the feasibility and outcome of this procedure. Methods and Results— All patients in whom percutaneous paravalvular regurgitation closure was attempted at our hospital were identified and included. Under echocardiographic and fluoroscopic guidance, patients underwent implantation of ≥1 an Amplatzer Septal Occluder, Duct Occluder, Muscular Ventricular Septal Defect Occluder, or Vascular Plug II. Percutaneous repair of 141 paravalvular defects was attempted in 115 patients (age, 67±12 years; men, 53%) with heart failure, hemolytic anemia, or both and who were at high risk of open surgery (mean estimated Society of Thoracic Surgeons mortality, 6.9%). Devices were implanted in 125 defects (89% of total defects), including in 19 patients with multiple defects. Because of the complexity of the procedures, wire exteriorization was required in 29 patients. Overall, successful percutaneous closure (defined as ≤1+ residual regurgitation) was achieved in 88 (77%) patients. Procedural time decreased with increasing case experience for percutaneous repair of both perimitral and periaortic defects. Overall, the 30-day complication rate was 8.7% (sudden and unexplained death, 1.7%; stroke, 2.6%; emergency surgery, 0.9%; bleeding, 5.2%). Two devices embolized during the procedure and were retrieved without sequelae. No procedural deaths occurred, but 2 (1.7%) patients died by 30 days. Conclusions— Percutaneous repair of paravalvular prosthetic regurgitation can be performed with a reasonable rate of procedural success and may be an initial therapeutic option, particularly in patients at significant risk for open surgery. Increased case experience is associated with shorter procedural time.
Application of Computer Modeling in Systemic VAD Support of Failing Fontan Physiology
Although the Fontan procedure has been enormously successful in palliation of single-ventricle patients, many seem to experience progressive failure of the Fontan circulation over time. Ventricular assist devices (VADs) have developed into stable platforms for long-term support of adult patients with heart failure. Given the success of axial flow devices, it was hypothesized that the technology could provide clinical benefit to failing Fontan patients. The aim of this study was to use a computer model to evaluate VAD support in failing Fontan physiology. A computer model of Fontan circulation with heart failure was developed and the HeartMate II (HM II) (Thoratec Corp) axial flow ventricular assist device was connected to this model in a systemic configuration to examine its impact. Cardiac catheterization data from 7 patients (8 catheterization studies) with failing Fontan physiology were applied to this model to evaluate the impact of using the HM II in this manner. When the HM II was used in a systemic configuration at 8000 rpm, there was a 35% decrease in the systemic venous pressure in the Fontan circuit and a 63% decrease in pulmonary capillary wedge pressure with a resultant 41% increase in CI. The model also predicted patient-specific parameters where the VAD may not benefit the patient, such as fixed elevated pulmonary vascular resistance, low systemic ventricular end-diastolic pressure, and high unresponsive systemic vascular resistance. These data suggest a potential benefit from application of axial flow VAD technology in the management of failing Fontan physiology. Clinical correlation will allow for refinement of this model as a predictive tool in discerning which patients may benefit from placement of a VAD and what issues must be addressed prior to implanting the device.