Back to Authors

Skjaerlund, Jonathan

Mayo Clinic

Mayo Clinic

Citations 3

Intraoperative Surgeon Assessment of Bone
Bernatz, James T. , Skjaerlund, Jonathan, Mikula, Anthony L. , Johnson, Sarah E. , Bydon, Mohamad , Fogelson, Jeremy L. , Elder, Benjamin D. , Sebastian, Arjun S. , Freedman, Brett A. , Goh, Brian C, Skjaerlund, Jonathan D, Fogelson, Jeremy, Elder, Benjamin, Huddleston, Paul, Karim, Mohammed, Sebastian, Arjun, Goh, Brian Chun Kim , Huddleston, P.M. , Karim, Mohammed, Nassr, Ahmad

Spine | October 19, 2023 | Volume: 49 | Issue: 16 | Pages: 1125-1129

10.1097/brs.0000000000004854 Get It

Study design. Retrospective observational study of consecutive patients. Objective. The purpose of the study is to determine if a surgeon’s qualitative assessment of bone intraoperatively correlates with radiologic parameters of bone strength. Summary of Background Data. Preoperative radiologic assessment of bone can include modalities such as computed tomography (CT) Hounsfield units (HUs), dual-energy x-ray absorptiometry (DXA) bone mineral density with trabecular bone score (TBS) and magnetic resonance imaging vertebral bone quality (VBQ). Quantitative analysis of bone with screw insertional torque and pull-out strength measurement has been performed in cadaveric models and has been correlated to these radiologic parameters. However, these quantitative measurements are not routinely available for use in surgery. Surgeons anecdotally judge bone strength, but the fidelity of the intraoperative judgment has not been investigated. Methods. All adult patients undergoing instrumented posterior thoracolumbar spine fusion by one of seven surgeons at a single center over a 3-month period were included. Surgeons evaluated the strength of bone based on intraoperative feedback and graded each patient’s bone on a 5-point Likert scale. Two independent reviewers measured preoperative CT HUs and magnetic resonance imaging VBQ. Bone mineral density, lowest T-score, and TBS were extracted from DXA within 2 years of surgery. Results. Eighty-nine patients were enrolled and 16, 28, 31, 13, and 1 patients had Likert grade 1 (strongest bone), 2, 3, 4, and 5 (weakest bone), respectively. The surgeon assessment of bone correlated with VBQ (τ=0.15, P=0.07), CT HU (τ=−0.31, P<0.01), lowest DXA T-score (τ=−0.47, P<0.01), and TBS (τ=−0.23, P=0.06). Conclusion. Spine surgeons’ qualitative intraoperative assessment of bone correlates with preoperative radiologic parameters, particularly in posterior thoracolumbar surgeries. This information is valuable to surgeons as this supports the idea that decisions based on feel in surgery have a statistical foundation.
Dynamic Radiographs Are Unreliable to Assess Arthrodesis Following Cervical Fusion: A Modeled Radiostereometric Analysis of Cervical Motion
Pinter, Zachariah W. , Skjaerlund, Jonathan, Michalopoulos, Giorgos D. , Bydon, Mohamad , Sebastian, Arjun S. , Freedman, Brett A. , Nathani, Karim R, Michalopoulos, Giorgos , Nathani, Karim Rizwan , Nassr, Ahmad

Spine | September 9, 2022 | Volume: 48 | Issue: 2 | Pages: 127-136

10.1097/brs.0000000000004470 Get It

Study Design. In vitro study. Objective. The purpose of the present study was to utilize an idealized cervical spine model to determine whether the parallax effect or changes in the position of the spine relative to the x-ray generator influence intervertebral motion parameters on dynamic cervical spine radiographs. Summary of Background Data. The utility of flexion-extension radiographs in clinical practice remains in question due to poor reliability of the parameters utilized to measure motion. Materials and Methods. A cervical spine model with tantalum beads inserted into the tip of each spinous process was utilized to measure interspinous process distance (IPD) on plain radiographs. The model was then manipulated to alter the generator angle and generator distance, and the IPD was measured. The impact of individual and combined changes in these parameters on IPD was assessed. Multivariate analysis was performed to identify independent drivers of variability in IPD measurements. Results. Isolated changes in the generator distance and generator angle and combined changes in these parameters led to significant changes in the measured IPD at each intervertebral level in neutral, flexion, and extension, which, in many instances, exceeded an absolute change of >1 mm or >2 mm. Multivariate analysis revealed that generator distance and generator angle are both independent factors impacting IPD measurements that have an additive effect. Conclusions. In an idealized cervical spine model, small clinically feasible changes in spine position relative to the x-ray generator produced substantial variability in IPD measurements, with absolute changes that often exceeded established cutoffs for determining the presence of pathologic motion across a fused segment. This study further reinforces that motion assessment on dynamic radiographs is not a reliable method for determining the presence of an arthrodesis unless these sources of variability can be consistently eliminated. Level of Evidence. 3
Titanium Cervical Cage Subsidence: Postoperative Computed Tomography Analysis Defining Incidence and Associated Risk Factors
Pinter, Zachariah W. , Reed, Ryder, Townsley, Sarah E., Mikula, Anthony L. , Dittman, Lauren E. , Xiong, Ashley , Skjaerlund, Jonathan, Michalopoulos, Giorgos D. , Currier, Bradford L. , Fogelson, Jeremy L. , Freedman, Brett A. , Bydon, Mohamad , Kepler, Christopher K. , Wagner, Scott C. , Elder, Benjamin D. , Sebastian, Arjun S. , Dittman, Lauren, Freedman, Brett A , Bydon, Mohamad , Michalopoulos, Giorgos , Nassr, Ahmad

Global Spine Journal | September 24, 2021 | Volume: 13 | Issue: 7 | Pages: 1703-1715

10.1177/21925682211046897 Get It

Study Design Retrospective cohort study Objective Substantial variability in both the measurement and classification of subsidence limits the strength of conclusions that can be drawn from previous studies. The purpose of this study was to precisely characterize patterns of cervical cage subsidence utilizing computed tomography (CT) scans, determine risk factors for cervical cage subsidence, and investigate the impact of subsidence on pseudarthrosis rates. Methods We performed a retrospective review of patients who underwent one- to three-levels of anterior cervical discectomy and fusion (ACDF) utilizing titanium interbodies with anterior plating between the years 2018 and 2020. Subsidence measurements were performed by two independent reviewers on CT scans obtained 6 months postoperatively. Subsidence was then classified as mild if subsidence into the inferior and superior endplate were both ≤2 mm, moderate if the worst subsidence into the inferior or superior endplate was between 2 to 4 mm, or severe if the worst subsidence into the inferior or superior endplate was ≥4 mm. Results A total of 51 patients (100 levels) were included in this study. A total of 48 levels demonstrated mild subsidence (≤2 mm), 38 demonstrated moderate subsidence (2-4 mm), and 14 demonstrated severe subsidence (≥4 mm). Risk factors for severe subsidence included male gender, multilevel constructs, greater mean vertebral height loss, increased cage height, lower Taillard index, and lower screw tip to vertebral body height ratio. Severe subsidence was not associated with an increased rate of pseudarthrosis. Conclusion Following ACDF with titanium cervical cages, subsidence is an anticipated postoperative occurrence and is not associated with an increased risk of pseudarthrosis.