Introducing an innovative IMPT algorithm toward clinic implementation of the MCF MKM RBE model for carbon ion therapy
Tong, Jindong, Liu, Hongcheng , Parisi, Alessio, Han, Dong , Yaddanapudi, Sridhar , Park, Chunjoo, Tan, Jun , Parisi, Alessio , Furutani, Keith, Parisi, Alessio , Yaddanapudi, Sridhar , Tong, Jindong, Parisi, Alessio, Yang, Yu , Liang, Xiaoying , Furutani, Keith M. , Beltran, Chris , Lu, Bo

Medical Physics | November 21, 2025 | Volume: 52 | Issue: 12 | Pages: No page available

10.1002/mp.70148 Get It

Abstract Purpose This study investigates a novel optimization framework that integrates the newly developed MCF MKM relative biological effectiveness (RBE) model into intensity modulated particle therapy (IMPT) planning for carbon ion therapy. Unlike conventional RBE models such as MKM or LEM, the MCF MKM provides detailed microdosimetric information, which improves predictive accuracy of cell survival but elevates both memory and time requirement in the optimization process. Furthermore, to the implicit nature of the MCF MKM, the gradient information, which is essential in inverse planning, is hardly accessible. In response, a randomized gradient‐free optimization method (RGFM) was developed to mitigate the computational challenge and achieve improved RBE dose distributions. Materials and Methods An RBE dose optimization problem was formulated based on the discretized MCF MKM, known as the Abridged Microdosimetry Distribution Model (AMDM). The RGFM was derived to find feasible and high‐quality settings of monitor unit for IMPT plans without the need for explicit gradient calculations. To verify the clinical plausibility of the proposed method, it was tested on two clinical scenarios—prostate and brain cases in comparison with benchmark plans derived solely from physical dose optimization. Computational times and dose‐volume histograms (DVHs) for both physical and RBE doses were evaluated. Results The RGFM algorithm successfully optimized the MCF MKM‐based IMPT plans. Compared to the benchmark, the RBE dose distributions showed improved coverage of the target and reduced hot spots. Such improvements were observed to coincide with trade‐offs in physical dose distributions. The complexity of the MCF MKM extended the computational time, yet high‐quality solutions were attainable in a clinically reasonable timeframe. Multi‐field optimization (MFO) further enhanced target coverage and critical organ sparing over single‐field optimization (SFO). Conclusions This proof‐of‐principle study confirmed the feasibility of using a randomized gradient‐free method to optimize RBE dose based on the MCF MKM in IMPT planning for carbon ion therapy. The approach provides a pathway for clinical adoption of advanced RBE models, potentially leading to more biologically informed and effective carbon ion therapy treatments. Future work involves refining algorithms, incorporating parallel computing, and performing additional case studies to improve computational efficiency and generalizability.
Optimizing dose rate to minimize delivery time in proton pencil beam dose‐driven continuous scanning
Han, Dong , Liu, Hongcheng , Tong, Jindong, Yaddanapudi, Sridhar , Park, Chunjoo, Tan, Jun , Beltran, Chris , Tan, Jun , Furutani, Keith, Beltran, Chris J , Yaddanapudi, Sridhar , Yang, Yu , Liang, Xiaoying , Tong, Jindong, Furutani, Keith M. , Lu, Bo, Tan, Jun

Medical Physics | September 10, 2025 | Volume: 52 | Issue: 9 | Pages: No page available

10.1002/mp.18098 Get It

Abstract Background Dose‐driven continuous scanning (DDCS) enhances the efficiency and precision of proton pencil beam delivery by reducing beam pauses inherent in discrete spot scanning (DSS). However, current DDCS optimization studies using traveling salesman problem (TSP) formulations often rely on fixed beam intensity and computationally expensive interpolation for move spot generation, limiting efficiency and methodological robustness. Purpose This study introduces a Break Spot‐Guided (BSG) method, combined with two acceleration strategies—dose rate skipping and bounding—to optimize beam intensity while minimizing beam delivery time (BDT). In addition, a ‐method is proposed for efficient move spot generation, aiming to balance computational efficiency and dose calculation accuracy. Methods The BSG framework simplifies the original mixed‐integer nonlinear programming (MINLP) problem by transforming it into a series of TSP evaluations using break‐spot dose rates. The two acceleration strategies are integrated to reduce computational complexity. The ‐method is introduced to efficiently generate move spots without compromising dose fidelity. The performance of the BSG method, with and without the acceleration strategies, and the ‐method, was evaluated across multiple clinical cases. Results By jointly optimizing the scan path and dose rate, the proposed BSG‐S‐B method offered the most efficient delivery, achieving a 64% reduction in BDT compared to DSS and a 57% reduction compared to Liu's method in the prostate case. These gains were consistently observed across all cases. Utilizing acceleration strategies, BSG‐S‐B significantly reduced computation time from hours to minutes (e.g., from 10 525.7 to 108.5 s in the prostate case, and from 6202.4 to 129.8 s in the head‐and‐neck case). When combined with the ‐method, it reduced the number of move spots by more than 50%, while still ensuring dosimetric quality. Conclusions The proposed framework significantly improves computational efficiency, making scan path optimization with dose rate selection feasible for clinical DDCS delivery. The ‐method effectively reduces computational complexity while maintaining dose calculation accuracy, demonstrating strong potential for clinical adoption in proton therapy treatment planning.
Redundancy‐weighted FDK reconstruction for dual‐detector combined‐scanning CBCT: Practical implementation for image guided particle therapy
Song, Bongyong , Whitaker, Thomas J. , Gautam, Archana S., Olberg, Sven, Choi, Byongsu , Lee, Sung Uk , Jeong, Jong Hwi , Kim, Jeongheon, Tan, Jun , Lü, Bo , Yaddanapudi, Sridhar , Beltran, Chris , Park, Justin C., Tan, Jun , Furutani, Keith, Beltran, Chris J , Yaddanapudi, Sridhar , Gautam, Archana S., Liang, Xiaoying , Furutani, Keith M. , Tan, Jun

Medical Physics | August 9, 2025 | Volume: 52 | Issue: 8 | Pages: No page available

10.1002/mp.17996 Get It

Abstract Background Cone‐beam computed tomography (CBCT) is essential for image‐guided particle therapy (IGPT), providing daily patient positioning, anatomical monitoring, and treatment verification. However, conventional single‐detector CBCT suffers from poor soft‐tissue contrast, long acquisition times, and motion artifacts, reducing its effectiveness for adaptive radiotherapy workflows. Addressing these challenges requires an advanced CBCT reconstruction approach capable of enhancing image quality while reducing scan time and radiation exposure. Purpose This study introduces a Dual Detector Combined Scanning (DDCS) CBCT reconstruction algorithm to overcome conventional CBCT limitations. By integrating a dual‐source, orthogonal imaging setup, DDCS significantly reduces scanning time and imaging artifacts. A modified Parker‐weighting algorithm further improves image reconstruction accuracy, ensuring high‐fidelity visualization. The goal is to enhance adaptive radiotherapy by improving real‐time patient positioning, dose verification, and motion management. Methods A dual‐detector CBCT system was designed to acquire orthogonal projections simultaneously, reducing scan time and improving data completeness. A modified Parker‐weighting algorithm corrected angular overlap distortions, ensuring better reconstruction accuracy. The system was evaluated using numerical and physical phantom studies to assess spatial resolution, contrast‐to‐noise ratio (CNR), and artifact reduction. Additionally, a dynamic phantom simulated respiratory motion, validating motion robustness for adaptive radiotherapy. Performance was compared against single‐detector CBCT, focusing on image fidelity, noise suppression, and computational efficiency. Results DDCS‐CBCT demonstrated higher CNR, reduced motion artifacts, and improved spatial resolution, leading to more accurate anatomical visualization. The system's efficiency enables faster, more reliable patient setup in IGPT while maintaining a lower imaging dose. Conclusion The proposed DDCS‐CBCT approach significantly improves imaging accuracy, reduces scan time, and enhances real‐time volumetric guidance in IGRT/IGPT. These findings support the clinical feasibility of the DDCS system and its integration into online adaptive radiotherapy workflows.
Dosimetric study of synchrotron rapid beam off control and skip spot function for high beam intensity proton therapy
Ogata, Toshiyuki, Nomura, Takuya , Umezawa, Masumi, Beltran, Chris , Beltran, Chris J , Yagi, Masashi , Furutani, Keith M. , Liang, Xiaoying , Yamada, Kei , Yamazaki, Hideya , Shimizu, Shinichi

Medical Physics | December 16, 2024 | Volume: 52 | Issue: 3 | Pages: 1867-1877

10.1002/mp.17589 Get It

Abstract Background All Hitachi proton pencil beam scanning facilities currently use discrete spot scanning (DSS). Mayo Clinic Florida (MCF) is installing a Hitachi particle therapy system with advanced technologies, including fast scan speeds, high beam intensity, rapid beam off control (RBOC), a skip spot function, and proton pencil beam scanning using dose driven continuous scanning (DDCS). A potential concern of RBOC is the generation of a shoulder at the end of the normal spot delivery due to a flap spot (FS) with a flap dose (FD), which has been investigated for carbon synchrotron but not for proton delivery. While investigated, for instance, for Hitachi's installation at MCF, this methodology could be applicable for all future high intensity proton deliveries. Purpose No Hitachi proton facility currently uses the proposed RBOC. This study aimed to understand the dosimetric impact of proton FD at MCF by simulating the FS with a Hitachi proton machine in research mode, reflecting the higher proton intensities expected with RBOC at MCF. Method Experiments were conducted to simulate MCF RBOC at Kyoto Prefecture University of Medicine (KPUM) in research mode, reducing delay time (Td) from 1.5 ms to 0.1 ms. 5,000 contiguous spots were delivered on the central axis for proton energies of 70.2, 142.5, and 220.0 MeV; at normal, high dose rate (HDR), and ultra‐high dose rate (uHDR) intensities; and at vertical and horizontal gantry angles for different Td. Measurements were taken using a fast oscilloscope and the nozzle's spot position monitor (SPM) and dose monitor (DM). A model was developed to predict FD dependence on beam intensity and assess the dosimetric impact for prostate and brain treatment plans. Two simulation types were planned: a flap DSS plan with FS at every spot and a flap DDCS plan with FS only at the end of each layer. Result FD was observed for RBOC with Td = 0.1 ms, showing no gantry angle dependence. FD increased with higher delayed dose rate (DDR), that is, beam intensity. The planning study showed dose volume histogram deterioration with increased FD compared to the clinical plan, but it was only significant for uHDR intensities. Deterioration was marginal in flap DSS plans for the HDR intensities planned at MCF, and flap DDCS plans were even less sensitive than flap DSS plans. Conclusion MCF is installing proton DDCS with higher beam intensities, a skip spot function, and fast beam‐off control. The resulting FD had an insignificant impact on dose distribution for two patient plans with both DSS and DDCS at the anticipated MCF intensities. However, significant dependence was observed in the case of uHDR. A method to measure the position and dose of the FS during commissioning is described in addition to recommendations for regular QA and log‐based proton patient‐specific quality assurance.
Enhanced IDOL segmentation framework using personalized hyperspace learning IDOL
Choi, Byong Su, Beltran, Chris , Olberg, Sven, Lü, Bo , Tan, Jun , Parisi, Alessio , Denbeigh, Janet M. , Yaddanapudi, Sridhar , Kim, Jin Sung , Park, Justin C., Song, Bongyong , Tan, Jun , Denbeigh, Janet, Beltran, Chris J , Parisi, Alessio , Yaddanapudi, Sridhar , Liang, Xiaoying , Furutani, Keith M. , Tan, Jun

Medical Physics | August 22, 2024 | Volume: 51 | Issue: 11 | Pages: 8568-8583

10.1002/mp.17361 Get It

AbstractBackgroundAdaptive radiotherapy (ART) workflows have been increasingly adopted to achieve dose escalation and tissue sparing under shifting anatomic conditions, but the necessity of recontouring and the associated time burden hinders a real‐time or online ART workflow. In response to this challenge, approaches to auto‐segmentation involving deformable image registration, atlas‐based segmentation, and deep learning‐based segmentation (DLS) have been developed. Despite the particular promise shown by DLS methods, implementing these approaches in a clinical setting remains a challenge, namely due to the difficulty of curating a data set of sufficient size and quality so as to achieve generalizability in a trained model.PurposeTo address this challenge, we have developed an intentional deep overfit learning (IDOL) framework tailored to the auto‐segmentation task. However, certain limitations were identified, particularly the insufficiency of the personalized dataset to effectively overfit the model. In this study, we introduce a personalized hyperspace learning (PHL)‐IDOL segmentation framework capable of generating datasets that induce the model to overfit specific patient characteristics for medical image segmentation.MethodsThe PHL‐IDOL model is trained in two stages. In the first, a conventional, general model is trained with a diverse set of patient data (n = 100 patients) consisting of CT images and clinical contours. Following this, the general model is tuned with a data set consisting of two components: (a) selection of a subset of the patient data (m < n) using the similarity metrics (mean square error (MSE), peak signal‐to‐noise ratio (PSNR), structural similarity index (SSIM), and the universal quality image index (UQI) values); (b) adjust the CT and the clinical contours using a deformed vector generated from the reference patient and the selected patients using (a). After training, the general model, the continual model, the conventional IDOL model, and the proposed PHL‐IDOL model were evaluated using the volumetric dice similarity coefficient (VDSC) and the Hausdorff distance 95% (HD95%) computed for 18 structures in 20 test patients.ResultsImplementing the PHL‐IDOL framework resulted in improved segmentation performance for each patient. The Dice scores increased from 0.810.05 with the general model, 0.83 for the continual model, 0.83 for the conventional IDOL model to an average of 0.87 with the PHL‐IDOL model. Similarly, the Hausdorff distance decreased from 3.06 with the general model, 2.84 for the continual model, 2.79 for the conventional IDOL model and 2.36 for the PHL‐IDOL model. All the standard deviations were decreased by nearly half of the values comparing the general model and the PHL‐IDOL model.ConclusionThe PHL‐IDOL framework applied to the auto‐segmentation task achieves improved performance compared to the general DLS approach, demonstrating the promise of leveraging patient‐specific prior information in a task central to online ART workflows.
Time structures of proton pencil beam scanning delivery on a microsecond scale measured with a pixelated semiconductor detector Timepix3
Ding, Xuanfeng , Liang, Xiaoying , Oancea, Cristina , Wang, Peilong, Rule, William G., Liu, Wei , Shen, Jiajian , Liang, Xiaoying , Liu, Wei , Shen, Jiajian , Charyyev, Serdar , Wang, Peilong, Bues, Martin , Lin, Liyong

Journal of Applied Clinical Medical Physics | August 13, 2024 | Volume: 25 | Issue: 9 | Pages: No page available

10.1002/acm2.14486 Get It

AbstractPurposeThe time structures of proton spot delivery in proton pencil beam scanning (PBS) radiation therapy are essential in many clinical applications. This study aims to characterize the time structures of proton PBS delivered by both synchrotron and synchrocyclotron accelerators using a non‐invasive technique based on scattered particle tracking.MethodsA pixelated semiconductor detector, AdvaPIX‐Timepix3, with a temporal resolution of 1.56 ns, was employed to measure time of arrival of secondary particles generated by a proton beam. The detector was placed laterally to the high‐flux area of the beam in order to allow for single particle detection and not interfere with the treatment. The detector recorded counts of radiation events, their deposited energy and the timestamp associated with the single events. Individual recorded events and their temporal characteristics were used to analyze beam time structures, including energy layer switch time, magnet switch time, spot switch time, and the scanning speeds in the x and y directions. All the measurements were repeated 30 times on three dates, reducing statistical uncertainty.ResultsThe uncertainty of the measured energy layer switch times, magnet switch time, and the spot switch time were all within 1% of average values. The scanning speeds uncertainties were within 1.5% and are more precise than previously reported results. The measurements also revealed continuous sub‐milliseconds proton spills at a low dose rate for the synchrotron accelerator and radiofrequency pulses at 7 µs and 1 ms repetition time for the synchrocyclotron accelerator.ConclusionThe AdvaPIX‐Timepix3 detector can be used to directly measure and monitor time structures on microseconds scale of the PBS proton beam delivery. This method yielded results with high precision and is completely independent of the machine log files.
Optimizing spot intensity with lower bound constraints for IMPT: Exposing shortcomings and introducing an enhanced strategy
Han, Dong , Tong, Jingdong, Liu, Hongcheng , Yaddanapudi, Sridhar , Park, Chunjoo, Tan, Jun , Beltran, Chris , Tan, Jun , Furutani, Keith, Beltran, Chris J , Yaddanapudi, Sridhar , Yang, Yu , Liang, Xiaoying , Furutani, Keith M. , Lu, Bo, Tan, Jun

Medical Physics | June 23, 2024 | Volume: 51 | Issue: 10 | Pages: 7523-7544

10.1002/mp.17265 Get It

AbstractBackgroundIntensity Modulated Proton Therapy (IMPT) is a sophisticated radiation treatment allowing for precise dose distributions. However, conventional spot selection strategies in IMPT face challenges, particularly with minimum monitor unit (MU) constraints, affecting planning quality and efficiency.PurposeThis study introduces an innovative Two‐Stage Mixed Integer Linear Programming (MILP) method to optimize spot intensity in IMPT with Lower Bound (LB) constraints. This method seeks to improve treatment planning efficiency and precision, overcoming limitations of existing strategies.MethodsOur approach evaluates prevalent IMPT spot selection strategies, identifying their limitations, especially concerning MU constraints. We integrated LB constraints into a MILP framework, using a novel three‐phase strategy for spot pool selection, to enhance performance over traditional heuristic methods and L1 + L∞ strategies. The method's efficacy was tested in eight study cases, using Dose‐Volume Histograms (DVHs), spot selection efficiency, and computation time analysis for benchmarking against established methods.ResultsThe proposed method showed superior performance in DVH quality, adhering to LB constraints while maintaining high‐quality treatment plans. It outperformed existing techniques in spot selection, reducing unnecessary spots and balancing precision with efficiency. Cases studies confirmed the method's effectiveness in producing clinically feasible plans with enhanced dose distributions and reduced hotspots, especially in cases with elevated LB constraints.ConclusionsOur Two‐Stage MILP strategy signifies a significant advancement in IMPT treatment planning. By incorporating LB constraints directly into the optimization process, it achieves superior plan quality and deliverability compared to current methods. This approach is particularly advantageous in clinical settings requiring minimum spot number and high MU LB constraints, offering the potential for improved patient outcomes through more precise and efficient radiation therapy plans.
Impact of Relative Biologic Effectiveness for Proton Therapy for Head and Neck and Skull-Base Tumors: A Technical and Clinical Review
Holtzman, Adam L. , Mohammadi, Homan , Furutani, Keith M. , Koffler, Daniel , McGee, L.A. , Gamez, Mauricio E. , Beltran, Chris , Koffler, Daniel M , McGee, Lisa A, Lester, Scott C. , Beltran, Chris J , Furutani, Keith M , Holtzman, Adam , Routman, David M. , Liang, Xiaoying

Cancers | May 21, 2024 | Volume: 16 | Issue: 11 | Pages: 1947

10.3390/cancers16111947 Get It

Proton therapy has emerged as a crucial tool in the treatment of head and neck and skull-base cancers, offering advantages over photon therapy in terms of decreasing integral dose and reducing acute and late toxicities, such as dysgeusia, feeding tube dependence, xerostomia, secondary malignancies, and neurocognitive dysfunction. Despite its benefits in dose distribution and biological effectiveness, the application of proton therapy is challenged by uncertainties in its relative biological effectiveness (RBE). Overcoming the challenges related to RBE is key to fully realizing proton therapy’s potential, which extends beyond its physical dosimetric properties when compared with photon-based therapies. In this paper, we discuss the clinical significance of RBE within treatment volumes and adjacent serial organs at risk in the management of head and neck and skull-base tumors. We review proton RBE uncertainties and its modeling and explore clinical outcomes. Additionally, we highlight technological advancements and innovations in plan optimization and treatment delivery, including linear energy transfer/RBE optimizations and the development of spot-scanning proton arc therapy. These advancements show promise in harnessing the full capabilities of proton therapy from an academic standpoint, further technological innovations and clinical outcome studies, however, are needed for their integration into routine clinical practice.
Impact of proton PBS machine operating parameters on the effectiveness of layer rescanning for interplay effect mitigation in lung SBRT treatment
Liang, Xiaoying , Flampouri, Stella , Park, Justin C., Yaddanapudi, Sridhar , Tan, Jun , Beltran, Chris , Tan, Jun , Shen, Jiajian , Yaddanapudi, Sridhar , Beltran, Chris J , Liang, Xiaoying , Liu, Chunbo , Shen, Jiajian , Lu, Bo, Furutani, Keith M. , Tan, Jun

Journal of Applied Clinical Medical Physics | April 9, 2024 | Volume: 25 | Issue: 7 | Pages: No page available

10.1002/acm2.14342 Get It

Abstract Background Rescanning is a common technique used in proton pencil beam scanning to mitigate the interplay effect. Advances in machine operating parameters across different generations of particle therapy systems have led to improvements in beam delivery time (BDT). However, the potential impact of these improvements on the effectiveness of rescanning remains an underexplored area in the existing research. Methods We systematically investigated the impact of proton machine operating parameters on the effectiveness of layer rescanning in mitigating interplay effect during lung SBRT treatment, using the CIRS phantom. Focused on the Hitachi synchrotron particle therapy system, we explored machine operating parameters from our institution's current (2015) and upcoming systems (2025A and 2025B). Accumulated dynamic 4D dose were reconstructed to assess the interplay effect and layer rescanning effectiveness. Results Achieving target coverage and dose homogeneity within 2% deviation required 6, 6, and 20 times layer rescanning for the 2015, 2025A, and 2025B machine parameters, respectively. Beyond this point, further increasing the number of layer rescanning did not further improve the dose distribution. BDTs without rescanning were 50.4, 24.4, and 11.4 s for 2015, 2025A, and 2025B, respectively. However, after incorporating proper number of layer rescanning (six for 2015 and 2025A, 20 for 2025B), BDTs increased to 67.0, 39.6, and 42.3 s for 2015, 2025A, and 2025B machine parameters. Our data also demonstrated the potential problem of false negative and false positive if the randomness of the respiratory phase at which the beam is initiated is not considered in the evaluation of interplay effect. Conclusion The effectiveness of layer rescanning for mitigating interplay effect is affected by machine operating parameters. Therefore, past clinical experiences may not be applicable to modern machines.
Investigation of scan path optimization in improving proton pencil beam scanning continuous delivery
Liu, Chunbo , Beltran, Chris , Park, Chunjoo, Yaddanapudi, Sridhar , Tan, Jun , Furutani, Keith M. , Liang, Xiaoying , Tan, Jun , Shen, Jiajian , Furutani, Keith M , Liang, Xiaoying , Beltran, Chris J , Yaddanapudi, Sridhar , Shen, Jiajian , Lu, Bo, Tan, Jun

Physics in Medicine & Biology | September 13, 2023 | Volume: 68 | Issue: 19 | Pages: 195023

10.1088/1361-6560/acf98e Get It

Abstract Objective . To investigate the impact of scan path optimization on the dose accuracy and beam delivery time (BDT) of proton pencil beam scanning in the dose-driven continuous scanning (DDCS). Approach . A diverse set of six clinical plans, representing various spot patterns and treatment sites, was used to evaluate the effectiveness of scan time optimization and scan length optimization. The DDCS dose discrepancy and BDT with optimized scan paths was compared to the default serpentine scan path. Main results . Both scan time optimization and scan path optimization were able to reduce the DDCS dose discrepancy compared to the default serpentine scan path. All plans, except for the layer repainting lung plan, achieved a 2%/2 mm gamma pass rate of over 99% and less than 1% PTV DVH root mean square error (RMSE) through scan path optimization. In the case of the layer repainting lung plan, when compared to the default serpentine scan path, the 2%/2 mm gamma pass rate showed improvements from 91.3% to 93.1% and 95.8%, while the PTV DVH RMSE decreased from 2.1% to 1.7% and 1.1% for scan time optimization and scan length optimization, respectively. Although scan time optimization resulted in shorter total scan times for all plans compared to the default scan path and scan length optimization tended to have longer total scan times. However, due to the short total scan times and their minimal contribution to the total BDT, the impact of scan path optimization on the total BDT was practically negligible. Significance . Both scan time optimization and scan length optimization proved to be effective in minimizing DDCS dose discrepancy. No definitive winner can be determined between these two optimization approaches. Both scan time and scan length optimization had minimal effect on the total BDT.