Back to Authors

Jackson, Daniel A.

Mayo Clinic

Mayo Clinic in Florida

Citations 3

Needleless Sampling and Medication Delivery: A Painless Innovation During CSF Irrigation
Salman, Saif Dawood, Peterson, Anna K. , Peterson, Wendy, Jackson, Daniel A., Vilela, Sara , Eallonardo, Sydney, Rambaram, Anya E., Miller, D, Mooney, Lesia , Brockman, Elyse , Jahromi, Behnam Rezai , Peterson, Wendy J, Mooney, Lesia H, Freeman, William D , Rezai Jahromi, Behnam , Freeman, William D.

Journal of Neuroscience Nursing | January 5, 2026 | Volume: 58 | Issue: 1 | Pages: 36-39

10.1097/jnn.0000000000000854 Get It

ABSTARCT BACKGROUND: IRRAflow is a novel active cerebrospinal fluid (CSF) exchange system for the treatment of hemorrhagic strokes and intracranial infections. It is a closed system that irrigates various medications dissolved in irrigation solutions at a speed of up to 180 mL/h, expediting resolution. Disrupting this closed system to withdraw CSF samples or infuse medications is necessary in certain circumstances. We report our novel approach for maintaining the sterility of the closed IRRAflow system using a needleless extension and assess the compatibility and safety of this technology throughout treatment. METHODS: We used a needleless extension to withdraw CSF samples and deliver medications to 5 patients treated with the IRRAflow system. We used 1 stopcock with a 3-way valve, 2 neutral needleless connectors, and 2 antiseptic caps. The stopcock was connected between the irrigation and drainage ports of the catheter. The needleless connectors were mounted at the 12 o’clock position of the attached stopcock and the irrigation port with antiseptic caps covering the distal ends. To initiate fluid exchange, the 2 needleless connectors were separated. The extra stopcock valve was connected between the drainage arm, the cassette, and the irrigation arm. The needleless connectors remained mounted at the 12 o’clock position of the stopcock and irrigation port throughout treatment. RESULTS: The needleless connectors mounted on the 12 o’clock position of the stopcock and irrigation port on the drainage and irrigation arms, respectively, provided efficient management of fluid exchange, CSF fluid sampling, and medication delivery. Our needleless extension was compatible with the IRRAflow device and prevented secondary infections despite repeated CSF sampling and medication delivery. CONCLUSION: The needleless extension facilitated a simple and safe interaction with the closed IRRAflow system without compromising the sterile environment during CSF sampling and medication delivery.
Safety and Tolerability of Concentrated Intraventricular Nicardipine for Poor-Grade Aneurysmal Subarachnoid Hemorrhage–Related Vasospasm
Zahra, Kaneez , Santos, Christan D. , Peacock, Sarah , Jackson, Daniel A., Siegel, Jason , Freeman, William D. , Peacock, Sarah H, Siegel, Jason L, Freeman, William D , Domingo, Ricardo A. , Turnbull, Marion T. , Tawk, Rabih G.

Journal of Personalized Medicine | February 27, 2023 | Volume: 13 | Issue: 3 | Pages: 428

10.3390/jpm13030428 Get It

Objective: To report the preliminary safety, tolerability, and cerebral spinal fluid (CSF) sampling utility of serial injections of concentrated intraventricular nicardipine (IVN) in the treatment of aneurysmal subarachnoid hemorrhage (aSAH). Methods: We report the clinical, radiographic, and laboratory safety and tolerability data of a retrospective case series from a single academic medical center. All patients with aSAH developed vasospasm despite enteral nimodipine and received serial injections of concentrated IVN (2.5 mg/mL). CSF injection safety, tolerability, and utility are defined and reported. Results: A total of 59 doses of concentrated IVN were administered to three patients with poor-grade SAH. In Case 1, a 33-year-old man with modified Fisher scale (mFS) grade 4 and Hunt-Hess scale (HH) score 4 received 26 doses; in Case 2, a 36-year-old woman with mFS grade 4 and HH score 5 received 13 doses; and in Case 3, a 70-year-old woman with mFS grade 3 and HH score 4 received 20 doses. No major safety or tolerability events occurred. Two patients were discharged to a rehabilitation facility, and one died after discharge from the hospital. Conclusions: A concentrated 4 mg IVN dose (2.5 mg/mL) in a 1.6 mL injection appears relatively safe and tolerable and potentially offers a second-line strategy for treating refractory vasospasm in poor-grade SAH without compromising intracranial pressure or cerebral perfusion pressure.
Colistin neurotoxicity mimicking Guillain-Barré syndrome in a patient with cystic fibrosis: case report and review
Camargo, Celeste, Narula, Tathagat , Jackson, Daniel A., Padro, Teresa , Freeman, W David, Freeman, William D.

Oxford Medical Case Reports | September 13, 2021 | Volume: 2021 | Issue: 9 | Pages: No page available

10.1093/omcr/omab080 Get It

ABSTRACT Guillain-Barré syndrome (GBS) is an immune-mediated polyneuropathy, which is characterized by areflexia and ascending paresthesia which can progress to a respiratory failure. Certain conditions, such as vasculitis and heavy metal and drug toxicity, may have misleadingly similar clinical presentation to GBS. We describe a case of a patient with cystic fibrosis and intravenous colistin-induced neurotoxicity mimicking GBS. The patient had used inhaled colistin on five occasions with no adverse effects, however, developed symptoms on the second day of intravenous treatment. Overlapping findings between immune-mediated polyneuropathy and drug-induced neurotoxicity include limb paresthesia and decreased reflexes. Perioral tingling, however, is a common presentation of colistin-induced neurotoxicity, and therefore, is an important differentiating factor. Early diagnosis prevents further neurologic decline, extensive unnecessary workup and potentially harmful incorrect management.