Back to Authors

Packer, Douglas L.

https://orcid.org/0000-0003-2060-869X

Mayo Clinic

Intermountain Medical Center

Citations 108

The hemodynamic spectrum of pulmonary vein stenosis from fibrosing mediastinitis
Ingraham, Brenden , Packer, Douglas L. , Holmes, David R. , Reddy, Yogesh N.V. , Ingraham, Brenden S , Nishimura, Rick

Catheterization and Cardiovascular Interventions | September 18, 2021 | Volume: 99 | Issue: 1 | Pages: 198-200

10.1002/ccd.29955 Get It

AbstractA 63‐year‐old man presented with hemoptysis and progressive dyspnea. His echocardiogram was concerning for pulmonary hypertension (PH) and CT chest showed fibrosing mediastinitis with possible cardiac involvement. Right heart catheterization revealed PH at rest and worsened with exercise. CT findings and simultaneous measurement of pulmonary capillary wedge pressure (PCWP), left atrial pressure, and left ventricular pressure helped diagnose pulmonary vein (PV) stenosis as the etiology of his PH. Both upper pulmonary veins were stented, and repeat exercise hemodynamic study revealed a substantial reduction in pulmonary arterial pressure with improvement in subjective dyspnea, cardiac output reserve, mechanical efficiency, and ventilatory efficiency. Repeat right upper PCWP normalized, consistent with resolution of the PV stenosis.
CABANA: underpowered and with detrimental protocol changes: is ‘ablation salvation’?—Reply by the authors of the CABANA trial
Packer, Douglas L. , Lee, Kerry L. , Mark, Daniel B.

EP Europace | September 8, 2021 | Volume: 24 | Issue: 1 | Pages: 3-3

10.1093/europace/euab237 Get It

Abstract 18318: Percutaneous Epicardial Access for Mapping and Ablation is Feasible in Patients With Prior Cardiac Surgery, Including Coronary Bypass Surgery
Killu, Ammar M. , Ebrille, Elisa , Munger, Thomas M. , Packer, Douglas L. , Friedman, Paul A. , Mulpuru, Siva K. , Asirvatham, Samuel J. , McLeod, Christopher J.

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.18318 Get It

Introduction: Prior cardiac surgery, especially the presence of coronary bypass grafts, is thought to preclude percutaneous epicardial access (EpiAcc) and, due to limited catheter maneuverability, mapping and ablation. The objective of our study was to evaluate the feasibility and safety of EpiAcc in patients with prior cardiac surgery. Methods: We retrospectively analyzed all patients who underwent EpiAcc as part of an ablation procedure between 01/01/2004-06/30/2013 at Mayo Clinic, Rochester, MN. All had documented VT or recurring, symptomatic PVCs. Baseline clinical characteristics and procedural characteristics were collected. Results: Of 162 patients that underwent EpiAcc, 18 had prior cardiac surgery (mean age 61 years, all male). This included 10 CABG, 2 epicardial ICD placement, 5 valve surgery (3 aortic valve, 2 mitral valve), 2 septal myectomy, 1 aortic arch replacement, 1 myocardial bridge unroofing and 1 myocardial perforation repair (3 patients had multiple procedures). Access was successful in 12 patients (66.7%); the inferior approach was utilized in 78%. Of patients with prior CABG, successful access was attained in 6 (60%). The average procedural time was 441.6 ± 141.3 minutes. Adhesiolysis was required in 10 patients with the sheath, access wire, pigtail catheter or ablation catheter. Intra-procedural coronary angiography was performed in 8 patients. There were a total of 45 VTs/PVCs ablated in 18 patients (average 2.5 ± 1.7), mean cycle length 463.6 ± 95.9ms. Ultimately, 12 patients (66.7%) underwent endocardial only ablation, 1 (5.5%) had epicardial only ablation while 5 (27.8%) had endocardial/epicardial ablation. The procedure was deemed successful in 13 patients (72.2%). Four patients had bleeding complications (pericardial effusion, pericardial hematoma, hemoperitoneum and pericardial tamponade [the latter required repair of the RV wall]). In patients with coronary grafts, there was no evidence of acute graft disruption. Conclusions: Percutaneous epicardial access is feasible in patients with previous cardiac surgery, including CABG. However, adhesiolysis is frequently required. Although the risk of coronary graft injury is low, life-threatening complications may occur.
Abstract 12443: In-Beam PET Verification of Catheter-free Arrhythmia Ablation by Scanned Carbon-12 Ion Beam Irradiation
Fiedler, F. , Helmbrecht, S. , Constantinescu, A., Lugenbiel, Patrick , Prall, Matthias, Kaderka, Robert, Takami, Mitsuru , Eichhorn, Anna, Thomas, Dierk , Katus, Hugo A. , Johnson, Susan B., Parker, Kay, Asirvatham, Samuel, Packer, Douglas L. , Lehmann, H. Immo , Graeff, Christian , Prall, M. W., Richter, Daniel , Parker, Kay, Debus, Jürgen , Bert, Christoph , Durante, Marco

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12443 Get It

Introduction: Highly precise irradiation using carbon-12 (12C) ions is a new means for catheter-free ablation. Besides energy deposition leading to the dose distribution, nuclear interactions lead to by-product β+-activity that can be measured using positron-emission-tomography (PET). Hypothesis: In-beam PET scanning during focused myocardial irradiation using 12C can adequately depict 12C dose deposition. Methods: Pigs were irradiated with 25, 40, and 55 Gy for AV node (AVN), LA-PV junction, and local LV freewall ablations. PET measurement was performed by means of a double head camera system installed at irradiation site. Coincidences were captured in end-expiration during beam extraction pauses of the accelerator. Results: Evaluation of PET images was qualitatively performed using the coronal plane of the activity distribution superimposed on the contrast-CT in the center of the target contour. Strong β+-activities were measured in AVN and LV ablations. In AVN ablations, activity was localized to the target location, without target activity spreading to the level of the aortic root or coronary sinus (Figure A). Local LV irradiations revealed strong activity in the target location, slightly extending into left lung and chest wall (Figure B). In 55 Gy animals, the cardiac entry channel showed increased activity, decreasing in 40 Gy and more so in 25 Gy animals. Conclusion: This is the first study applying in-beam PET to track 12C dose-deposition into the target location for catheter-free ablation in intact animals. Correlation of β+-activity to electrophysiological outcome, lesion induction, and potential side-effects may be critically important in dosing therapy and predicting outcomes.
Abstract 12112: Clinical Outcomes of Percutaneous Epicardial Ablation
Killu, Ammar M. , Sugrue, Alan , Hodge, David O. , Munger, Thomas M. , Mulpuru, Siva K. , Packer, Douglas L. , Friedman, Paul A. , Al‐Hijji, Mohammed , McLeod, Christopher J. , Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12112 Get It

Introduction: Percutaneous epicardial access (EAc) is increasingly performed as part of VT/PVC ablation, especially in those that have failed prior ablation. We aimed to delineate the outcomes of EAc. Methods: We retrospectively analyzed individuals undergoing EAc for arrhythmia ablation between June 2004 and July 2014. Acute procedural success was defined as elimination/non-inducibility of the clinical arrhythmia after ablation; clinical success was defined as absence of symptoms/arrhythmia. Results: Of 175 patients, 126 (72%) were male with a mean age of 52.8±15.7 years. Eighty-three (47.4%) patients had NICM, 25 (14.3%) had ICM and 34 (19.4%) had normal hearts. Baseline EF was 44±16%. Patients had failed an average of 1.7±1.2 antiarrhythmic drugs; 139 patients (79%) had failed prior endocardial (endo) ablation (average 1.3±1.1). Six (3.4%) had prior EAc and 18 (10.3%) prior cardiac surgery. The indication for ablation was VT or PVC in 113 (64.6%) and 60 (34.3%) patients, respectively. Successful access was obtained in 168 (98%) patients. Anterior access, inferior access, or both, was utilized in 89 (52.7%), 77 (45.6%) and 2 (1.2%) patients, respectively. There were an average of 2.7±2.2 VT/PVCs identified, and 1.6±1.1 ablated. Endo, epicardial (epi) or combined ablation was performed in 58 (33.1%), 14 (8%), and 100 (57.1%) patients, respectively; 3 did not undergo ablation. Procedural success was obtained in 158 of 173 (91.3%) patients for whom data was available. At 12 months, clinical success was maintained in 62% with no difference between endo, epi or combined ablation (figure). Cardiac tamponade requiring repeat EAc occurred in 12 (6.9%) patients. There were no procedural related deaths. Conclusion: Epicardial access is feasible in almost all patients with no prior cardiac surgery, and permits acute procedural success in 91.3% of patients, most of whom had failed previous ablation. Furthermore, complications are relatively infrequent in this complex cohort.
Abstract 3229: First Time Validation of Point to Point NavX Map Registration to 3D Subject-Specific Computed Tomography (CT)
Kolasa, Mark, Johnson, Susan B., Olson, Eric, Schweitzer, Jeffrey S. , Packer, Douglas L. , Okumura, Yasuo , Schweitzer, Jeffrey

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_726-c Get It

Background: Current mapping systems use simultaneous displays of overlapping 3D maps and pre-acquired CT images of the LA to “pseudo-register” data sets rather than specifically “register” each point of one mapping data set to the other. The appropriateness of the 2 data set match has not been validated. Since significant surface to surface mismatch errors may occur, this study was undertaken to quanititatively validate NavX map to CT registration and determine its suitability for guiding AF ablation. Methods: Sixty-four slice, multidetector CT scans were acquired in 8 dogs and segmented to establish subject-specific LA/PV volumes for importation into the EnSite mapping system. A detailed multi-surface geometry (NavX map) was collected by navigating a mapping catheter in target LA and PVs. Using a novel developmental registration algorithm the map was registered to LA/PV CT volume. Validation was performed using the registered 3D CT model for the guidance of ablation at the location of multiple implanted radio-opaque markers. Results: A total of 39 radio-opaque markers were implanted before CT including 9 LSPV, 8 RSPV, 7 RIPV, 9 LIPV, 3 roof, and 3 LAA locations. Subsequent registration of individual NavX maps to acquired 3D CT volume was successfully completed in all animals. RF ablations were performed at the predicted 3D registered model locations of the radio-opaque markers using 5 mm tip RF ablation catheter. Resulting mean lesion size was 5.3 x 6.5 mm. The lesions enveloped the point of marker attachment to the myocardium in 31/36 (86%) ablations. The average distance from the center of the RF lesion to the targeted site was 2.5 ± 1.5mm. 47 points were successfully navigated under fluorscopic and ICE guidance. All points were accurately portrayed on the 3D registered model. 3 points in the region of the RSPV floor did have minor offsets on the model due to technically difficult segmentation of the RSPV from the right pulmonary artery. Conclusion: These data demonstrate the feasibility of registering NavX derived geometries to CT data sets accommodating sources of cardiac, respiratory, and translational cycle dependent error. Catheter navigation precisely conducted using the registered model demonstrates accuracy within the range required for RF ablation.
Abstract 3223: Feasibility and Safety of the Integrated 3D Image and Contact Force-Guided Ablation for Atrial Fibrillation with the Hansen Robotic Catheter Sheath System
Henz, Benhur Davi , Johnson, Susa B, Packer, Douglas L. , Okumura, Yasuo , Johnson, Susan B.

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_725-a Get It

Background: Current technologies to fully “register” surrogate maps onto 3D CT (CartoMerge, NavxMerge) or 3D ICE images (CartoSound) have emerged to guide ablation. The feasibility of navigation with the Hansen Robotic Catheter Sheath System (HRCS) has also been reported. Integrated 3D Image and contact force sensor with this robotic system may allow for feasibility and safety for guiding complex anatomic-based ablation. Methods: Circumferential pulmonary vein (PV) ablation with the robotic system guided by integrated 3D images (CartoMerge, NavxMerge or CartoSound) (n=3), were done and compared to manual manipulation guided by the integrated 3D images (CartoSound) (n=8). Each ablation was performed using contact force ranges of 10 –20 grams (20W, 17 ml/min flow, 30 seconds). Accuracy of PV ablation was assessed by comparing distance from the PV ostia (specific 4 sites) to the ablative points on the 3D image structures, and the corresponding distances of the actual ablative lesions at pathologic exam. Results: Using three integrated 3D image systems, circumferential PV ablation was successfully guided in 6 PVs (3 RSPVs and 3 LSPVs) with the robotic system. During all ablations with contact forces of 10 –20 grams, no impedance rises, pops or type 2 microbubbles were seen. Accuracy of the PV ablation was 0.22±0.84 mm (range 0 –2). The PV rings were 100% circumferential by electroanatomic mapping, yielding an 86±7% (range 80 –98%) uninterrupted circumferential ablative ring around each PV with 1.1 ± 0.4 gaps (3.0 ± 0.9 mm). These resulting parameters were equal to those in the integrated 3D image-based manual navigation (Accuracy: 0.5±0.9 (range 0 –2.5) mm, Gaps:1.3 ± 0.9 ( 2.6 ± 0.9 mm), circumferential lesions 88 ± 10% (range 70 –100). Conclusions: This feasibility study demonstrated successful integrated 3D image and contact force-guided robotic ablation. Contact sensor guided 3D volume construction and real time 3D images accurately replicated atrial and venous anatomy, resulting in successful circumferential ablation.
Abstract 2750: Multi-detector Computed Tomography Is An Accurate Screening Imaging Modality For Detection Of Thrombus In Patients Undergoing Catheter Ablation Of Atrial Fibrillation
Martinez, Matthew W. , Kirsch, Jacobo , Williamson, Eric E. , Cha, Yong‐Mei , Friedman, Paul A. , Ommen, Steve R. , Callahan, Mark J., Syed, Imran S., Feng, DaLi, Beinborn, Douglas S., Packer, Douglas L. , Brady, Peter A. , Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_610-b Get It

Introduction Multi-detector computed tomography (MDCT) is commonly used to identify pulmonary vein and left atrial anatomy prior to catheter ablation for atrial fibrillation (CAAF). Additionally, transesophageal echocardiography (TEE) is utilized to exclude left atrial/left atrial appendage thrombus (ICT). Whether MDCT alone can be used to exclude thrombus obviating the need for TEE is unknown. Methods All Pts referred for CAAF at Mayo Clinic between March 2004 and October 2006 were included. Clinical data (including CHADS score), 64 slice MDCT (non-ECG gated), TEE and intra-cardiac echocardiograph (ICE) were all performed and recorded. Image data was reviewed independently and blinded. The left atrial appendage (LAA) was defined as fully opacified or underfilled. An underfilled LAA was further interrogated using a region of interest over the filling defect and mean attenuation in Hounsfield Units (HU) were recorded. Results In total 400 Pts (mean age 56 ± 10 yrs; 76% male; EF 56 ± 10 % ) were included. 362 had no ICT by TEE nor filling defect by MDCT. 38 patients had an underfilled LAA in whom ICT was confirmed by TEE in 7. Sensitivity and specificity of MDCT for ICT was 100% and 92% respectively with a NPV of 100%. In 19 Pts with underfilled LAA’s, a mean LAA emptying velocity was found to be significantly reduced at 26 cm/s (6 – 61 cm/s). Those with a thrombus had a mean attenuation value below 70 HU. CHADS2 score was higher (2.0 versus 1.0) in Pts with LAA filling defect versus those without LAA filling defect. All Pts with confirmed thrombus were taking Warfarin. ICT was not seen in any Pts aged <52 yrs with CHADS score ≤1. Conclusions Sensitivity and specificity of MDCT for detection of LAA thrombus is high. LAA filling defects on MDCT correlate with low emptying velocities by TEE and low attenuation value in HU. These data would suggest that in the absence of MDCT filling defect, no further imaging is required. TEE should be utilized prior to CAAF to investigate MDCT filling defects. Multidetector Computed Tomography for the Detection of LAA Thrombus
Abstract 2247: Feasibility of Long Ventricular Transmural Linear Lesions Created with a New Novel Saline-Injection Needle Catheter: Utility for Ablating Scar Related VT
Henz, Benhur Davi , Curley, Michael , Johnson, Susan B., Packer, Douglas L. , Okumura, Yasuo

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_489-d Get It

Introduction: Unstable scar related ventricular tachycardia (VT) is a common problem after myocardial infarction. Aggressive ablation may be limited, however, by incomplete scar penetration with available RF energy delivery technologies. The purpose of this study was to test the feasibility of full thickness linear ablation of infarcted ventricular substrate with a high penetration virtual electrode needle based electrode system. Methods: Chronic infarcted (> 2months) mongrel dogs (35–40 kg) underwent percutaneous catheter ablation of the LV with a saline-injection needle catheter employing an 8 mm 20-GA tip. Constant power at 40W was delivered for 90 sec via the virtual electrode needle during infusion of saline 10 ml/h at 50°C. The lines were created under electroanatomic map guidance and intracardiac ultrasound (ICE). The ejection fraction was monitored immediately before and after the ablation. One week after ablation, the dogs where restudied using CARTO epicardial and endocardial voltage mapping and hemodynamic testing. Results: The ablation lines created by a virtual electrode energy delivery made in the antero-lateral wall showed mean length of 4.4±1.4 cm. The mean area of ablation per lesion in the endocardium, mid myocardium and epicardium was 1.1±1.0, 2.6±1.3 and 1.9±1.3 cm 2 (p<0.05) respectively, with a mean ablation depth of 1.5±0.5 cm. Sixty-four percent of the length of lesions were transmural and in non-transmural areas had an average depth of 90±16% of wall thickness. The mean number of gaps/line was 0.5±0.7 with a length of 0.6 cm. Ejection fraction was 50±14, 52±17 and 52±13% before, after and 1 week post ablation respectively. At one week the epicardial and endocardial areas of low bipolar voltage < 1.5mV and dense scar < 0.5mV in the Carto map were 11.4±1.2 and 7.9±6.1cm 2 respectively which measurements were confirmed at necropsy by macroscopic scar in the epicardium and endocardium of 11.8±4.3 and 6.6±4.1 cm 2 respectively. Conclusion: This new novel saline-injection needle catheter effectively creates continuous long transmural lines in the infarcted LV. These data also confirm that the macroscopic ablation lesions can be consistently and accurately monitored by 3D electroanatomical mapping in both endocardium and epicardium.
Abstract 1733: Complete Ablation of Typical Atrial Flutter in Patients with Corrected Congenital Heart Defects: “Non-Traditional” Access to the Surgically Excluded Cavotricuspid Isthmus
Yaman, Malek M. El, Packer, Douglas L. , Porter, Co-burn J., Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_365-b Get It

Background: Although multiple macroreentrant atrial flutters are seen in postoperative patients with congenital heart disease, cavotricuspid isthmus (CVTI) dependent flutter remains a fairly common arrhythmia in this group. When a Fontan or atrial switch (Mustard/Senning) type of procedure is performed, a portion of the CVTI is excluded from catheter access obtainable via a systemic venous route. We evaluated different techniques to access this excluded portion and completely ablate CVTI dependent flutter. Methods/Results: Between 1990 and 2007, 140 patients with surgically corrected congenital heart disease underwent an ablation procedure at our institution. Their records were reviewed to identify those with prior Fontan or atrial switch procedure who had documented CVTI dependent flutter requiring ablation. Data collected included methods of catheter access, circuits observed or induced, the location and number of ablation lines, immediate and long-term success, and complications. Results: Sixteen patients were identified (14, Fontan; 2, Mustard). In 12/16 (75%) patients bidirectional block of CVTI dependent flutter could not be achieved by right atrial (venous approach) ablation alone. In 7 of those, the excluded portion of the CVTI was targeted for ablation. This was accomplished by a retrograde transaortic approach via an interventricular communication then through the right atrioventricular valve (5 patients). Another retrograde transaortic approach was used with the catheter crossing the left atrioventricular valve then an atrial septal communication (one patient). A third approach involved an antegrade transconduit puncture (one patient). In all 7 patients, successful ablation of CVTI dependent flutter with bidirectional block was achieved. Post-procedure, one patient had temporary AV block requiring pacemaker placement. Follow-up was available on 4/7 patients (3 to 22 months, mean 10 months) with no documented recurrence of their CVTI dependent flutter. Conclusion: Even when surgical procedures exclude a portion of the CVTI, complete ablation for typical atrial flutter with resulting bidirectional block can be achieved via “non-traditional” approaches targeting the surgically excluded arrhythmogenic tissue.