Abstract Background Artificial intelligence (AI) research in colonoscopy is progressing rapidly but widespread clinical implementation is not yet a reality. We aimed to identify the top implementation research priorities. Methods An established modified Delphi approach for research priority setting was used. Fifteen international experts, including endoscopists and translational computer scientists/engineers, from nine countries participated in an online survey over 9 months. Questions related to AI implementation in colonoscopy were generated as a long-list in the first round, and then scored in two subsequent rounds to identify the top 10 research questions. Results The top 10 ranked questions were categorized into five themes. Theme 1: clinical trial design/end points (4 questions), related to optimum trial designs for polyp detection and characterization, determining the optimal end points for evaluation of AI, and demonstrating impact on interval cancer rates. Theme 2: technological developments (3 questions), including improving detection of more challenging and advanced lesions, reduction of false-positive rates, and minimizing latency. Theme 3: clinical adoption/integration (1 question), concerning the effective combination of detection and characterization into one workflow. Theme 4: data access/annotation (1 question), concerning more efficient or automated data annotation methods to reduce the burden on human experts. Theme 5: regulatory approval (1 question), related to making regulatory approval processes more efficient. Conclusions This is the first reported international research priority setting exercise for AI in colonoscopy. The study findings should be used as a framework to guide future research with key stakeholders to accelerate the clinical implementation of AI in endoscopy.
S0138 Soft Coagulation of the Resection Margin for the Prevention of Residual or Recurrent Adenoma After Endoscopic Mucosal Resection of Large Sessile Colonic Polyps: A Multi-Center, Randomized Controlled Trial
The NCCN Guidelines for Colorectal Cancer (CRC) Screening describe various colorectal screening modalities as well as recommended screening schedules for patients at average or increased risk of developing sporadic CRC. They are intended to aid physicians with clinical decision-making regarding CRC screening for patients without defined genetic syndromes. These NCCN Guidelines Insights focus on select recent updates to the NCCN Guidelines, including a section on primary and secondary CRC prevention, and provide context for the panel’s recommendations regarding the age to initiate screening in average risk individuals and follow-up for low-risk adenomas.
Breast Cancer Metastasis Presenting as Colonic Polyps
ABSTRACT Breast cancer is the most common malignancy among women and is the second leading cause of cancer-related death among women in the United States. Rarely, breast cancer can metastasize to the gastrointestinal tract. We present a case of metastatic breast cancer diagnosed after finding metastatic lesions appearing as polyps during a colonoscopy.
Multitarget Stool DNA Screening in Clinical Practice: High Positive Predictive Value for Colorectal Neoplasia Regardless of Exposure to Previous Colonoscopy
OBJECTIVES: Multitarget stool DNA (MT-sDNA) testing has grown as a noninvasive screening modality for colorectal cancer (CRC), but real-world clinical data are limited in the post-FDA approval setting. The effect of previous colonoscopy on MT-sDNA performance is not known. We aimed to evaluate findings of colorectal neoplasia (CRN) at diagnostic colonoscopy in patients with positive MT-sDNA testing, stratified by patient exposure to previous colonoscopy. METHODS: We identified consecutive patients completing MT-sDNA testing over a 39-month period and reviewed the records of those with positive tests for neoplastic findings at diagnostic colonoscopy. MT-sDNA test positivity rate, adherence to diagnostic colonoscopy, and the positive predictive value (PPV) of MT-sDNA for any CRN and neoplastic subtypes were calculated. RESULTS: Of 16,469 MT-sDNA tests completed, testing returned positive in 2,326 (14.1%) patients. After exclusion of patients at increased risk for CRC, 1,801 patients remained, 1,558 (87%) of whom underwent diagnostic colonoscopy; 918 of 1,558 (59%) of these patients had undergone previous colonoscopy, whereas 640 (41%) had not. Any CRN was found in 1,046 of 1,558 patients (PPV = 67%). More neoplastic lesions were found in patients without previous colonoscopy (73%); however, the rates remained high among those who had undergone previous colonoscopy (63%, P < 0.0001). The large majority (79%) of patients had right-sided neoplasia. DISCUSSION: MT-sDNA has a high PPV for any CRN regardless of exposure to previous colonoscopy. Right-sided CRN was found at colonoscopy in most patients with positive MT-sDNA testing, representing a potential advantage over other currently available screening modalities for CRC.
Impact of feedback on adenoma detection rates: Outcomes of quality improvement program
AbstractBackground and AimFeedback has been shown to improve performance in colonoscopy including adenoma detection rate (ADR). The frequency at which feedback should be given is unknown. As part of a quality improvement program, we sought to measure the outcome of providing quarterly and monthly feedback on colonoscopy quality measures.MethodsAll screening colonoscopies performed at endoscopy unit at Mayo Clinic Arizona by gastroenterologists between October 2010 and December 2012 were reviewed. Quality indicators, including ADR, were extracted for each individual endoscopist, and feedback was provided. The study period was divided into four distinct groups: pre‐intervention that served as baseline, quarterly feedback, monthly feedback, and post‐intervention. Based on ADR, endoscopists were grouped into “low detectors” (≤ 25%), “average detectors” (26–35%), and “high detectors” (> 35%).ResultsA total of 3420 screening colonoscopies were performed during the study period (555 patients during pre‐intervention, 1209 patients during quarterly feedback, 599 during monthly feedback, and 1057 during the post‐intervention period) by 16 gastroenterologists. The overall ADR for the group improved from 30.5% to 37.7% (P = 0.003). Compared with the pre‐interventional period, all quality indicators measured significantly improved during the monthly feedback and post‐intervention periods but not in the quarterly feedback period.ConclusionsIn our quality improvement program, monthly feedback significantly improved colonoscopy quality measures, including ADR, while quarterly feedback did not. The impact of the intervention was most prominent in the “low detectors” group. Results were durable up to 6 months following the intervention.
Background. Appropriate recommendations for a followup exam after an index colonoscopy are an important quality indicator. Lack of knowledge of polyp pathology at the time of colonoscopy may be one reason that followup recommendations are not made. Aim. To describe and compare the accuracy of followup recommendations made at colonoscopy based on the size and number of polyps with recommendations made at a later date based on actual polyp pathology. Methods. All patients who underwent screening and surveillance colonoscopy from March, 2012, to August, 2012, were included. Surveillance recommendations from the endoscopy reports were graded as “accurate” or “not accurate” based on the postpolypectomy surveillance guidelines established by US Multisociety Task Force on Colon Cancer. Polyp pathology was then used to regrade the surveillance recommendations. Results. Followup recommendations were accurate in 759/884 (86%) of the study colonoscopies, based upon size and number of polyps with the assumption that all polyps were adenomatous. After incorporating actual polyp pathology, 717/884 (81%) colonoscopies had accurate recommendations. Conclusion. In our practice, the knowledge of actual polyp pathology does not change the surveillance recommendations made at the time of colonoscopy in the majority of patients.
Capsule Endoscopy in Patients with Implantable Electromedical Devices is Safe
Background and Study Aims. The presence of an implantable electromechanical cardiac device (IED) has long been considered a relative contraindication to the performance of video capsule endoscopy (CE). The primary aim of this study was to evaluate the safety of CE in patients with IEDs. A secondary purpose was to determine whether IEDs have any impact on images captured by CE.Patients and Methods.A retrospective chart review of all patients who had a capsule endoscopy at Mayo Clinic in Scottsdale, AZ, USA, or Rochester, MN, USA, (January 2002 to June 2010) was performed to identify CE studies done on patients with IEDs. One hundred and eighteen capsule studies performed in 108 patients with IEDs were identified and reviewed for demographic data, method of preparation, and study data.Results.The most common indications for CE were obscure gastrointestinal bleeding (77%), anemia (14%), abdominal pain (5%), celiac disease (2%), diarrhea (1%), and Crohn’s disease (1%). Postprocedure assessments did not reveal any detectable alteration on the function of the IED. One patient with an ICD had a 25-minute loss of capsule imaging due to recorder defect. Two patients with LVADs had interference with capsule image acquisition.Conclusions.CE did not interfere with IED function, including PM, ICD, and/or LVAD and thus appears safe. Additionally, PM and ICD do not appear to interfere with image acquisition but LVAD may interfere with capsule images and require that capsule leads be positioned as far away as possible from the IED to assure reliable image acquisition.
Using CT Enterography to Monitor Crohn's Disease Activity: A Preliminary Study