Back to Authors

Rea, Robert F.

Mayo Clinic

Mayo Clinic

Citations 19

Capsule Endoscopy in Patients with Implantable Electromedical Devices is Safe
Harris, Lucinda A. , Hansel, Stephanie L. , Rajan, Elizabeth , Rea, Robert F., Crowell, Michael D. , Fleischer, David E., Pasha, Shabana F., Gurudu, Suryakanth, Heigh, Russell I., Shiff, Arthur D., Post, J, Leighton, Jonathan A. , Srivathsan, Komandoor , Crowell, Michael D , Hansel, Stephanie L

Gastroenterology Research and Practice | April 3, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-5

10.1155/2013/959234 Get It

Background and Study Aims. The presence of an implantable electromechanical cardiac device (IED) has long been considered a relative contraindication to the performance of video capsule endoscopy (CE). The primary aim of this study was to evaluate the safety of CE in patients with IEDs. A secondary purpose was to determine whether IEDs have any impact on images captured by CE.Patients and Methods.A retrospective chart review of all patients who had a capsule endoscopy at Mayo Clinic in Scottsdale, AZ, USA, or Rochester, MN, USA, (January 2002 to June 2010) was performed to identify CE studies done on patients with IEDs. One hundred and eighteen capsule studies performed in 108 patients with IEDs were identified and reviewed for demographic data, method of preparation, and study data.Results.The most common indications for CE were obscure gastrointestinal bleeding (77%), anemia (14%), abdominal pain (5%), celiac disease (2%), diarrhea (1%), and Crohn’s disease (1%). Postprocedure assessments did not reveal any detectable alteration on the function of the IED. One patient with an ICD had a 25-minute loss of capsule imaging due to recorder defect. Two patients with LVADs had interference with capsule image acquisition.Conclusions.CE did not interfere with IED function, including PM, ICD, and/or LVAD and thus appears safe. Additionally, PM and ICD do not appear to interfere with image acquisition but LVAD may interfere with capsule images and require that capsule leads be positioned as far away as possible from the IED to assure reliable image acquisition.
A Test of the “Epinephrine Hypothesis” in Humans
Golczynska, Anna, Stuhlmuller, John E., Holmes, Courtney, Rea, Robert F., Grossman, Ehud , Lenders, Jacques W.M. , Goldstein, David S.

Hypertension | June 11, 2012 | Volume: 33 | Issue: 1 | Pages: 36-43

10.1161/01.hyp.33.1.36 Get It

Abstract —According to the “epinephrine hypothesis,” circulating epinephrine taken up by sympathetic nerves is coreleased with norepinephrine during sympathetic stimulation and binding of coreleased epinephrine to presynaptic β-adrenoceptors augments exocytotic release of norepinephrine, contributing to high blood pressure. This study examined whether infusion of a physiologically active amount of epinephrine affects subsequent vascular responses and the estimated rate of entry of norepinephrine into regional venous plasma (norepinephrine spillover). Each of 3 experiments included intravenous infusion of 3 H-norepinephrine, measurements of forearm vascular resistance, and intra-arterial infusion of epinephrine (3 ng/min per deciliter forearm volume). In experiment 1, subjects underwent lower body negative pressure (LBNP−25 mm Hg) before and after intra-arterial epinephrine; in experiment 2, LBNP and intra-arterial yohimbine before and after intra-arterial epinephrine; and in experiment 3, intravenous nitroprusside before and after intra-arterial epinephrine. In all subjects, intra-arterial epinephrine produced ipsilateral pallor and decreased forearm vascular resistance. Ipsilateral venous epinephrine increased by 10-fold. Epinephrine did not affect forearm vasoconstrictor responses to LBNP or vasodilator responses to intra-arterial yohimbine or intravenous nitroprusside; did not affect venous norepinephrine levels or norepinephrine spillover during LBNP, yohimbine, LBNP during yohimbine, or nitroprusside; and did not increase venous epinephrine levels during any of these manipulations. Loading of forearm sympathetic terminals with epinephrine therefore does not augment subsequent neurogenic vasoconstriction or norepinephrine release in the human forearm in response to sympathetic stimulation. The findings are inconsistent with the epinephrine hypothesis.
Global Right Atrial Mapping of Human Atrial Flutter: The Presence of Posteromedial (Sinus Venosa Region) Functional Block and Double Potentials
Friedman, Paul A. , Luria, David , Munger, Thomas M. , Shen, Win K., Rea, Robert F., Stanton, Marshall S., Hammill, Stephen C., Packer, Douglas L. , Fenton, Alexis M. , Jahangir, Arshad

Circulation | June 11, 2012 | Volume: 101 | Issue: 13 | Pages: 1568-1577

10.1161/01.cir.101.13.1568 Get It

Background —Previous studies of atrial flutter have found linear block at the crista terminalis; this was thought to predispose the patient to the arrhythmia. More recent observations, however, have demonstrated crista conduction. We sought to characterize the posterior boundary of atrial flutter. Methods and Results —Patients with counterclockwise flutter (n=20), clockwise flutter (n=3), or both (n=5) were studied using two 20-pole catheters. Biplane fluoroscopy determined catheter positions. During counterclockwise flutter, craniocaudal activation occurred along the entire lateral and posterior right atrial walls. Septal activation proceeded caudocranially. In all patients, a line of block was seen in the posteromedial (sinus venosa) right atrium; this was manifested by the presence of double potentials where the upward and downward activations collided. Anatomic location was confirmed by intracardiac echocardiography in 9 patients. In patients with clockwise flutter, the line of block and double potentials were seen in the same location during counterclockwise flutter, but the activation sequence around the line of block was reversed. Pacing near the site of double potentials during sinus rhythm excluded a fixed line of block, and premature atrial complexes demonstrated functional block with manifest double potentials. In 2 patients, posterior ectopy organized to subsequently initiate isthmus-dependent atrial flutter. Conclusions —(1) A functional line of block is seen at the posteromedial (sinus venosa region) right atrium during counterclockwise and clockwise atrial flutter. (2) All lateral wall right atrial activation can be uniform during flutter, without linear block or double potentials in the region of the crista terminalis. (3) Activation at the site of posteromedial right atrial functional block can organize to subsequently initiate isthmus-dependent atrial flutter.
Cardiac Sympathetic Reserve and Response to Cardiac Resynchronization Therapy
Cha, Yong‐Mei , Dong, Ying-Xue, Kemp, Bradley J. , Oh, Jae K. , Miyazaki, Chinami , Hayes, David L. , Rea, Robert F., Asirvatham, Samuel J. , Webster, Tracy L., Dalzell, Connie, Hodge, David O. , Herges, Regina M., Yong, Yan-zhong, Zhang, Yanhua, Chen, Peng‐Sheng , Chareonthaitawee, Panithaya , Zhang, Yanhua, Asirvatham, Samuel J

Circulation: Heart Failure | March 19, 2011 | Volume: 4 | Issue: 3 | Pages: 339-344

10.1161/circheartfailure.110.959858 Get It

Background— The objective of the present study was to investigate the effect of cardiac resynchronization therapy (CRT) on cardiac autonomic function. Methods and Results— This prospective study included 45 consecutive patients with heart failure who received CRT devices with defibrillator and 20 age-matched, healthy control subjects. At baseline and 3 months and 6 months after CRT, we assessed New York Heart Association (NYHA) class, 6-minute walk distance, plasma sympathetic biomarker nerve growth factor, echocardiography, heart rate variability and cardiac presynaptic sympathetic function determined by iodine 123 metaiodobenzylguanidine scintigraphy. After CRT, NYHA class improved by 1 class ( P <0.001), and left ventricular ejection fraction increased by 8% ( P <0.001). Along with improvement in the standard deviation of all normal-to-normal R-R intervals (85.63±31.66 ms versus 114.79±38.99 ms; P =0.004) and the standard deviation of the averaged normal-to-normal R-R intervals (82.62±23.03 ms versus 100.50±34.87 ms; P =0.004), the delayed heart/mediastinum (H/M) ratio increased (1.82 [0.58] versus 1.97 [0.59]; P =0.03), whereas the mean (SD) H/M washout rate was reduced (48% [19%] versus 37% [22%]; P =0.01). Twenty-two of 45 study patients responded to CRT, with a reduction of left ventricular end-systolic volume index >15%. Compared with nonresponders, responders had a higher delayed H/M ratio (2.11 versus 1.48; P =0.003) and lower H/M washout rate (37% versus 62%; P =0.003) at baseline. Conclusions— CRT improved sympathetic function. Cardiac sympathetic reserve may be a marker for the reversibility of failing myocardial function.
Dyssynchrony Indices To Predict Response to Cardiac Resynchronization Therapy
Miyazaki, Chinami , Redfield, Margaret M. , Powell, Brian D. , Lin, Grace, Herges, Regina M., Hodge, David O. , Olson, Lyle J. , Hayes, David L. , Espinosa, Raúl E. , Rea, Robert F., Nelson, Susan M., Miller, Fletcher A., Oh, Jae K. , Bruce, Charles J.

Circulation: Heart Failure | July 21, 2010 | Volume: 3 | Issue: 5 | Pages: 565-573

10.1161/circheartfailure.108.848085 Get It

Background— Whether mechanical dyssynchrony indices predict reverse remodeling (RR) or clinical response to cardiac resynchronization therapy (CRT) remains controversial. This prospective study evaluated whether echocardiographic dyssynchrony indices predict RR or clinical response after CRT. Methods and Results— Of 184 patients with heart failure with anticipated CRT who were prospectively enrolled, 131 with wide QRS and left ventricular ejection fraction <35% had 6-month follow-up after CRT implantation. Fourteen dyssynchrony indices (feasibility) by M-mode (94%), tissue velocity (96%), tissue Doppler strain (92%), 2D speckle strain (65% to 86%), 3D echocardiography (79%), and timing intervals (98%) were evaluated. RR (end-systolic volume reduction ≥15%) occurred in 55% and more frequently in patients without (71%) than in patients with (42%) ischemic cardiomyopathy ( P =0.002). Overall, only M-mode, tissue Doppler strain, and total isovolumic time had a receiver operating characteristic area under the curve (AUC) greater than the line of no information, but none of these were strongly predictive of RR (AUC, 0.63 to 0.71). In nonischemic cardiomyopathy, no dyssynchrony index predicted RR. In ischemic cardiomyopathy, M-mode (AUC, 0.67), tissue Doppler strain (AUC, 0.79), and isovolumic time (AUC, 0.76) -derived indices predicted RR ( P <0.05 for all), although the incremental value was modest. No indices predicted clinical response assessed by Minnesota Living with Heart Failure Questionnaire, 6-minute walk distance, and peak oxygen consumption. Conclusions— These findings are consistent with the Predictors of Response to CRT study and do not support use of these dyssynchrony indices to guide use of CRT.
Effect of Long-Term Right Ventricular Pacing in Young Adults With Structurally Normal Heart
Sagar, Sandeep , Shen, Win-Kuang, Asirvatham, Samuel J. , Cha, Yong‐Mei , Espinosa, Raúl E. , Friedman, Paul A. , Hodge, David O. , Munger, Thomas M. , Porter, Co-burn J., Rea, Robert F., Hayes, David L. , Jahangir, Arshad , Asirvatham, Samuel J

Circulation | April 5, 2010 | Volume: 121 | Issue: 15 | Pages: 1698-1705

10.1161/circulationaha.109.866343 Get It

Background— Right ventricular pacing increases the risk of heart failure in adults with structural heart disease. The impact of prolonged right ventricular pacing in adults without structural heart disease is not fully characterized and may depend on interactions of pacing with abnormal substrate predisposing to ventricular dysfunction. Methods and Results— We assessed the effect of right ventricular pacing in patients who underwent pacemaker implantation for isolated congenital atrioventricular block between 1964 and 2005. To assess for immunologic contribution to cardiac dysfunction, outcomes were compared between patients with (Ab + ) and without (Ab − ) antinuclear antibody during adulthood and an age- and sex-matched Olmsted County, Minnesota, population. Of 103 patients (mean±SD age, 32±19 years), 18 were Ab + . Long-term survival free of new heart failure after pacemaker implantation in isolated congenital atrioventricular block patients was worse than in the matched population ( P <0.001). This difference was attributable to the development of heart failure in 12 Ab + patients (67%; P <0.001), without differences between Ab − patients (2%) and the matched population (2%; P =0.7). Compared with baseline, at last follow-up, left ventricular ejection fraction did not decline in Ab − (53±9% to 57±12%) but decreased in Ab + (52±10% to 38±12%; P =0.03) patients. Survival was similar in Ab − patients and the Minnesota population (98%; P =0.7) but worse in Ab + patients (79%; P <0.01). Conclusions— The natural history of patients with isolated congenital atrioventricular block who require pacing depends upon their antibody status. Antinuclear antibody status was a predictor for the development of heart failure and death. Long-term right ventricular pacing alone does not appear to be associated with development of heart failure, deterioration in ventricular function, or reduced survival in Ab − isolated congenital atrioventricular block patients.
Strain Dyssynchrony Index Correlates With Improvement in Left Ventricular Volume After Cardiac Resynchronization Therapy Better Than Tissue Velocity Dyssynchrony Indexes
Miyazaki, Chinami , Lin, Grace, Powell, Brian D. , Espinosa, Raúl E. , Miller, Fletcher A., Karon, Barry L., Rea, Robert F., Hayes, David L. , Oh, Jae K. , Bruce, Charles J.

Circulation: Cardiovascular Imaging | July 23, 2008 | Volume: 1 | Issue: 1 | Pages: 14-22

10.1161/circimaging.108.774513 Get It

Background— Various dyssynchrony indexes derived from tissue velocity and strain imaging have been proposed to predict the effectiveness of cardiac resynchronization therapy (CRT). We sought to compare the effect of CRT on dyssynchrony indexes derived by tissue velocity and strain and to determine which baseline intraventricular dyssynchrony parameters correlate with improvement in left ventricular volume after CRT. Methods and Results— Echocardiography with tissue Doppler imaging was performed in 45 patients with systolic heart failure at baseline, 1 day after CRT, and a median of 6 months after CRT. We calculated septal–lateral delay and anteroseptal–posterior delay and standard deviation of time to peak systolic velocity in the 12 basal and mid-left ventricular segments (Tv-SD). The standard deviation for time to peak strain in the 12 basal and mid-left ventricular segments (Tε-SD) was calculated as a strain-derived dyssynchrony index. None of the tissue velocity–derived dyssynchrony indexes improved after CRT (septal–lateral delay, P =0.39; anteroseptal–posterior delay, P =0.46; Tv-SD, P =0.30), whereas Tε-SD decreased significantly after CRT ( P <0.001). Improvement in Tε-SD 1 day after CRT correlated with the reduction in end-systolic volume at follow-up ( r =0.66; P <0.001). Baseline Tε-SD demonstrated significant correlation with the reduction of end-systolic volume at follow-up ( r =0.57; P <0.001); however, baseline tissue velocity–derived dyssynchrony indexes failed to predict the effect of CRT. Conclusions— The strain-derived dyssynchrony index is a better measurement than the tissue velocity dyssynchrony index for monitoring changes in mechanical dyssynchrony after CRT and for predicting reduction in left ventricular volume after CRT.
Mechanisms and Utility of Discrete Great Arterial Potentials in the Ablation of Outflow Tract Ventricular Arrhythmias
Bunch, T. Jared , Asirvatham, Samuel J. , Edwards, William D. , Friedman, Paul A. , Munger, Thomas M. , Hammill, Stephen C., Cha, Yong‐Mei , Brady, Peter A. , Rea, Robert F., Packer, Douglas L. , Shen, Win-Kuang, Srivathsan, Komandoor , Jahangir, Arshad , Bradley, David J. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | June 5, 2008 | Volume: 1 | Issue: 1 | Pages: 30-38

10.1161/circep.107.750315 Get It

Background— Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. Methods and Results— Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients’ average age was 41�14 years. The average ejection fraction was 0.52�0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential–ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential–ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential–spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10�4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. Conclusions— Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.
Catheter Ablation for Atrial Fibrillation in Patients With Obesity
Cha, Yong‐Mei , Friedman, Paul A. , Asirvatham, Samuel J. , Shen, Win-Kuang, Munger, Thomas M. , Rea, Robert F., Brady, Peter A. , Monahan, Kristi H. , Hodge, David O. , Meverden, Ryan A., Hammill, Stephen C., Packer, Douglas L. , Jahangir, Arshad , Gersh, Bernard J. , Asirvatham, Samuel J

Circulation | May 13, 2008 | Volume: 117 | Issue: 20 | Pages: 2583-2590

10.1161/circulationaha.107.716712 Get It

Background— Obesity is a risk factor for atrial fibrillation and other cardiovascular conditions. Our objective was to determine whether catheter-based ablation effectively treated atrial fibrillation in obese patients. Methods and Results— Five hundred twenty-three consecutive patients with symptomatic, medication-refractory atrial fibrillation underwent catheter ablation. Patients were grouped by body mass index (lean, <25 kg/m 2 ; overweight, 25 to 29.9 kg/m 2 ; obese, ≥30 kg/m 2 ). Outcome and quality of life were measured with a general health survey (Medical Outcomes Study 36-item Short-Form General Health Survey [SF-36]); patients were assessed before ablation and at 3 and 12 months after the procedure. Two hundred twenty-eight study patients (44%) were overweight, and 201 (38%) were obese. Twelve months after curative ablation, 72% of patients were free of atrial fibrillation without the use of antiarrhythmic agents; 84% were arrhythmia free when those receiving medication were included. Atrial fibrillation was eliminated in 75%, 72%, and 70% of the lean, overweight, and obese patients, respectively, at 12 months ( P =0.41, trend test). SF-36 scores were lower for patients with higher body mass index ( P <0.05) at baseline. SF-36 scores improved in every functional domain for all body mass index groups after ablation. The mean SF-36 total physical score increased from 59±20 at baseline to 77±19 in 12 months ( P <0.001). The total mental health score improved from 66±18 to 79±16 in 12 months ( P <0.001). Conclusions— Catheter ablation of atrial fibrillation was effective in obese patients. Coexistence of atrial fibrillation and obesity indicated lower SF-36 scores, but the improvement in quality of life was consistent across all body mass index categories.