Comparing Surgical and Clinical Success Rates of Ahmed FP7, and Baerveldt 250 and Baerveldt 350 Glaucoma Drainage Devices
Kilgore, Khin P. , Grosinger, Alexander J. , Liu, Liang Yen , Jamali, Sepideh, Arora, Nitika, White, Launia J. , Khanna, Cheryl L.

Journal of Glaucoma | October 12, 2022 | Volume: 32 | Issue: 3 | Pages: 210-220

10.1097/ijg.0000000000002136 Get It

Précis: Surgical and clinical success rates were similar among Ahmed FP7, and Baerveldt 250 and 350 glaucoma drainage devices at three years. Purpose: To compare rates of surgical and clinical success in patients with Ahmed FP7 (FP7), Baerveldt 250 (B250), or Baerveldt 350 (B350) glaucoma drainage devices (GDDs). Design: A retrospective cohort study. Methods: A total of 157 eyes of 129 adult patients with FP7, B250, B350 GDDs, and 190 eyes of 99 medically controlled glaucoma patients were enrolled at a tertiary care institution from August 2017 through July 2019. They were followed through April 2020. The main outcome measures included surgical and clinical failure. Surgical failure was defined as intraocular pressure (IOP) outside 5–21 mm Hg, IOP reduced <20% below baseline, additional glaucoma surgery, GDD removal, or no light perception. Eyes that did not meet their goal IOP ranges or required secondary glaucoma interventions were deemed clinical failures. Results: A total of 43 (12.4%) FP7, 36 (10.4%) B250, 78 (22.5%) B350, and 190 (54.8%) medically treated control eyes were enrolled. By the postoperative year 3 visit, 10 (23.2%) FP7, 11 (30.6%) B250, and 32 (41.0%) B350 eyes had met a surgical failure criterion (P=0.127). There were no significant differences in the numbers of eyes meeting their IOP target ranges (P=0.510), and rates of secondary glaucoma surgeries (P=0.270). Overall clinical success was attained among 83.3% FP7, 81.8% B250, and 68.0% B350 eyes (P=0.447). Conclusions: The GDD groups were similar in their rates of success, based on both the surgical and clinical success definitions.
Rates of Diplopia in Ahmed FP7, Baerveldt 250, and 350 Glaucoma Patients Compared With Medical Controls
Kilgore, Khin P. , Stern, Nicole Caroline, Sabbagh, Nouran, Jamali, Sepideh, White, Launia J. , Sit, Arthur J. , Bitrian, Elena , Roddy, Gavin W. , Khanna, Cheryl L. , Sit, Arthur J , Wang, Feng

Journal of Glaucoma | May 28, 2021 | Volume: 30 | Issue: 7 | Pages: 579-584

10.1097/ijg.0000000000001886 Get It

Precis: Diplopia was present in ~20% of patients with Ahmed FP7 (FP7) or Baerveldt 350 (B350), compared with 5% to 6% in those with Baerveldt 250 (B250) or controls, suggesting risk of diplopia should be included in preoperative counseling. Purpose: The purpose of this study was to examine the prevalence of diplopia and strabismus in patients with B250, B350, or FP7 glaucoma drainage devices (GDD). Materials and Methods: In this cohort study, glaucoma patients 18 years and above who had received, or would be receiving, a B250, B350, or FP7 GDD, and medically treated controls were consecutively enrolled from August 8, 2017, through July 31, 2019. The Diplopia Questionnaire was administered ≥30 days postoperatively, and upon enrollment to the controls. All diplopic patients underwent orthoptic measurements, which were reviewed by a strabismus specialist. Patients with GDDs in quadrants other than superotemporal, multiple GDDs, or scleral buckles were excluded. Bonferroni correction was applied for pairwise comparisons. Results: Diplopia was reported in 23/129 (17.8%) GDD patients and 5/99 (5.1%) control patients (P=0.003): 8/35 (22.9%) FP7, 2/32 (6.3%) B250, and 13/62 (21.0%) B350, with significant differences between FP7 versus controls (P=0.014) and B350 versus controls (P=0.011). Diplopia was attributable to GDD in 2 FP7 (5.9%, 95% confidence interval: 0.7-19.2), 0 B250, and 4 B350 (6.5%, 95% confidence interval: 1.7-15.2) patients, without significant differences between the GDDs. Conclusions: Patients with the larger (B350) or the higher profile plate (FP7) GDDs were more likely to experience diplopia than controls, and diplopia was attributable to the GDD in ~6% of patients with either a FP7 or a B350 GDD. Since diplopia can affect patients’ quality of life, preoperative counseling for GDD surgery, particularly B350 and FP7, should include a discussion of the risk of diplopia.
Efficacy and safety of blepharoptosis repair after incisional glaucoma surgery
Song, Allisa J. , Khanna, Cheryl L. , Jamali, Sepideh, Roddy, Gavin W. , Wagner, Lilly H.

European Journal of Ophthalmology | March 29, 2021 | Volume: 32 | Issue: 1 | Pages: 122-128

10.1177/11206721211006643 Get It

Purpose: There is an increased risk for development of blepharoptosis after incisional glaucoma surgery. Data on safety and efficacy of ptosis repair in this group of patients in limited. The goal of this study is to evaluate outcomes and identify potential risk factors for failure of ptosis repair in eyes with history of incisional glaucoma surgery. Methods: A retrospective chart review was performed of all patients who underwent incisional glaucoma surgery, specifically trabeculectomy or implantation of glaucoma drainage device (GDD), and subsequent ptosis repair at a single institution from 2009 to 2019. Ptosis surgery outcomes were compared to a control group who underwent ptosis repair after cataract surgery. Results: Seventy-eight eyes of 64 patients were included in the glaucoma surgery group. The rate of severe ptosis (margin reflex distance 1 ⩽ 0 mm) among glaucoma surgery patients was higher compared to control (35 of 78 (44.9%) vs 23 of 82 (28.6%). Ptosis repair was successful in 59 of 78 eyes (75.6%), which was similar to control. Risk for revision surgery was increased more than five-fold in the GDD group compared to control. There were no cases of early or late bleb-related complications. Conclusions: Ptosis repair can be performed safely in patients after incisional glaucoma surgery. Müller muscle conjunctival resection and external levator advancement are equally effective. Patients with history of GDD should be advised about the potentially increased risk of need for revision surgery.
Personal Experience With COVID-19 and Community Screening of Diabetic Retinopathy in Iran
Jamali, Sepideh, Ashrafi, Elham , Mohammadi, Seyed-Farzad

Journal of Diabetes Science and Technology | May 28, 2020 | Volume: 14 | Issue: 4 | Pages: 737-738

10.1177/1932296820930045 Get It