Back to Authors

Pinter, Zachariah W.

https://orcid.org/0000-0003-3011-0991

Mayo Clinic

Mayo Clinic

Citations 35

The Effect of C2 Muscular Exposure Technique on Radiographic and Clinical Outcomes After C2–T2 Posterior Cervical Fusion
Pumford, Andrew, Townsley, Sarah, Reed, Ryder, Chen, Selby , Deen, H. Gordon , Bydon, Mohamad , Fogelson, Jeremy L. , Elder, Benjamin D. , Currier, Bradford L. , Freedman, Brett A. , Sebastian, Arjun S. , Katsos, Konstantinos, Clarke, Michelle, Levy, Hannah A. , Pinter, Zachariah W. , Salmons, Harold I. , Katsos, Konstantinos, Abode-Iyamah, Kingsley , Clarke, Michelle J. , Nassr, Ahmad , Karamian, Brian A.

Clinical Spine Surgery | April 19, 2024 | Volume: 37 | Issue: 10 | Pages: E448-E454

10.1097/bsd.0000000000001626 Get It

Study Design: Retrospective cohort analysis. Objective: To determine whether the C2 exposure technique was a predictor of change in cervical alignment and patient-reported outcomes measures (PROMs) after posterior cervical decompression and fusion (PCDF) for degenerative indications. Background: In PCDF handling of the C2 posterior paraspinal musculature during the operative approach varies by surgeon technique. To date, no studies have investigated whether maintenance of the upper cervical semispinalis cervicis attachments as compared with complete reflection of upper cervical paraspinal musculature from the posterior bony elements is associated with superior radiographic and clinical outcomes after PCDF. Patients and Methods: All adult patients who underwent C2–T2 PCDF for myelopathy or myeloradiculopathy at multi-institutional academic centers between 2013 and 2020 were retrospectively identified. Patients were dichotomized by the C2 exposure technique into semispinalis preservation or midline muscular reflection groups. Preoperative and short and long-term postoperative radiographic outcomes (upper cervical alignment, global alignment, and fusion status) and PROMs (Visual Analog Scale–Neck, Neck Disability Index, and Short Form-12) were collected. Univariate analysis compared patient factors, radiographic measures, and PROMs across C2 exposure groups. Results: A total of 129 patients met the inclusion/exclusion criteria (73 muscle preservation and 56 muscle reflection). Patients in the muscular preservation group were on average younger (P = 0.005) and more likely to have bone morphogenic protein (P < 0.001) and C2 pars screws (P = 0.006) used during surgery. Preoperative to postoperative changes in C2 slope, C2 tilt, C2–C3 segmental lordosis, C2–C3 listhesis, C0–C2 Cobb angle, proximal junctional kyphosis, ADI, C1 lamina-occiput distance, C2 sagittal vertical axis, C2–C7 lordosis, and PROMs at all follow-up intervals did not vary significantly by C2 exposure technique. Likewise, there were no significant differences in fusion status, C2–C3 pseudoarthrosis, C2 screw loosening, and complication and revision rates between C2 exposure groups. Conclusions: Preservation of C2 semispinalis attachments versus muscular reflection did not significantly impact cervical alignment, clinical outcomes, or proximal junction complications in long-segment PCDF. Level of Evidence: Level III.
Paraspinal Sarcopenia is Associated With Worse Patient-Reported Outcomes Following Laminoplasty for Degenerative Cervical Myelopathy
Pinter, Zachariah W. , Reed, Ryder, Townsley, Sarah E., Mikula, Anthony L. , Lakomkin, Nikita , Kazarian, Erick R., Michalopoulos, Giorgos D. , Freedman, Brett A. , Currier, Bradford L. , Elder, Benjamin D. , Bydon, Mohamad , Fogelson, Jeremy L. , Sebastian, Arjun S. , Kazarian, Erick, Fogelson, Jeremy, Michalopoulos, Giorgos , Nassr, Ahmad

Spine | March 27, 2023 | Volume: 48 | Issue: 11 | Pages: 772-781

10.1097/brs.0000000000004650 Get It

Study Design. Retrospective cohort study. Objective. The present study is the first to assess the impact of paraspinal sarcopenia on patient-reported outcome measures (PROMs) following cervical laminoplasty. Background. While the impact of sarcopenia on PROMs following lumbar spine surgery is well-established, the impact of sarcopenia on PROMs following laminoplasty has not been investigated. Methods. We performed a retrospective review of patients undergoing laminoplasty from C4-6 at a single institution between 2010 and 2021. Two independent reviewers utilized axial cuts of T2-weighted magnetic resonance imaging sequences to assess fatty infiltration of the bilateral transversospinales muscle group at the C5-6 level and classify patients according to the Fuchs Modification of the Goutalier grading system. PROMs were then compared between subgroups. Results. We identified 114 patients for inclusion in this study, including 35 patients with mild sarcopenia, 49 patients with moderate sarcopenia, and 30 patients with severe sarcopenia. There were no differences in preoperative PROMs between subgroups. Mean postoperative neck disability index scores were lower in the mild and moderate sarcopenia subgroups (6.2 and 9.1, respectively) than in the severe sarcopenia subgroup (12.9, P=0.01). Patients with mild sarcopenia were nearly twice as likely to achieve minimal clinically important difference (88.6 vs. 53.5%; P<0.001) and six times as likely to achieve SCB (82.9 vs. 13.3%; P=0.006) compared with patients with severe sarcopenia. A higher percentage of patients with severe sarcopenia reported postoperative worsening of their neck disability index (13 patients, 43.3%; P=0.002) and Visual Analog Scale Arm scores (10 patients, 33.3%; P=0.03). Conclusion. Patients with severe paraspinal sarcopenia demonstrate less improvement in neck disability and pain postoperatively and are more likely to report worsening PROMs following laminoplasty. Level of Evidence. 3
Is Severe Neck Pain a Contraindication to Performing Laminoplasty in Patients With Cervical Spondylotic Myelopathy?
Pinter, Zachariah W. , Mikula, Anthony L. , Reed, Ryder, Lakomkin, Nikita , Townsley, Sarah E., Wright, Breydan, Kazarian, Erick R., Michalopoulos, Giorgos D. , Currier, Bradford L. , Freedman, Brett A. , Bydon, Mohamad , Elder, Benjamin D. , Fogelson, Jeremy L. , Sebastian, Arjun S. , Fogelson, Jeremy, Michalopoulos, Giorgos , Nassr, Ahmad

Clinical Spine Surgery | March 15, 2023 | Volume: 36 | Issue: 3 | Pages: 127-133

10.1097/bsd.0000000000001444 Get It

Study Design: Retrospective review. Objective: The purpose of this study was to investigate the surgical outcomes in a cohort of patients with severe preoperative axial neck pain undergoing laminoplasty for cervical spondylotic myelopathy (CSM). Summary of Background Data: No study has investigated whether patients with severe axial symptoms may achieve satisfactory neck pain and disability outcomes after laminoplasty. Methods: We performed a retrospective review of 91 patients undergoing C4-6 laminoplasty for CSM at a single academic institution between 2010 and 2021. Patient-reported outcome measures (PROMs), including Neck Disability Index (NDI), visual analog scale (VAS) Neck, and VAS Arm, were recorded preoperatively and at 6 months and 1 year postoperatively. Patients were stratified as having mild pain if VAS neck was 0–3, moderate pain if 4–6, and severe pain if 7–10. PROMs were then compared between subgroups at all the perioperative time points. Results: Both the moderate and severe neck pain subgroups demonstrated a substantial improvement in VAS neck from preoperative to 6 months postoperatively (−3.1±2.2 vs. −5.6±2.8, respectively; P<0.001), and these improvements were maintained at 1 year postoperatively. There was no difference in VAS neck between subgroups at either the 6-month or 1-year postoperative time points. Despite the substantially higher mean NDI in the moderate and severe neck pain subgroups preoperatively, there was no difference in NDI at 6 months or 1 year postoperatively (P=0.99). There were no differences between subgroups in the degree of cord compression, severity of multifidus sarcopenia, sagittal alignment, or complications. Conclusions: Patients with moderate and severe preoperative neck pain undergoing laminoplasty achieved equivalent PROMs at 6 months and 1 year as patients with mild preoperative neck pain. The results of this study highlight the multifactorial nature of neck pain in these patients and indicate that severe axial symptoms are not an absolute contraindication to performing laminoplasty in well-aligned patients with CSM.
Delayed open treatment of aortic penetration by a thoracic pedicle screw: illustrative case
Hobson, Sandra L. , Yaszemski, Michael J. , Levy, Hannah A. , Pinter, Zachariah W.

Journal of Neurosurgery: Case Lessons | February 27, 2023 | Volume: 5 | Issue: 9 | Pages: No page available

10.3171/case22533 Get It

BACKGROUND Iatrogenic aortic injury from pedicle screw malpositioning or anterior prominence in posterior spinal fusion represents a rare but potentially devasting complication. While intraoperative aortic injury is associated with hemodynamic instability, delayed presentations of pedicle screw aortic impingement or violation often present insidiously with pseudoaneurysm or vascular remodeling in clinically asymptomatic patients. Currently, there is a lack of guidance in the field for the recommended surveillance, urgency of operative intervention, and optimal surgical management of delayed pedicle screw aortic injuries. OBSERVATIONS The following case study discusses the open treatment of delayed thoracic aortic penetration from an excessively long T12 pedicle screw in an asymptomatic adolescent patient with idiopathic scoliosis. The pedicle screw prominence anteriorly was corrected by burring the screw tip until it was flush with the vertebral body. The associated aortic injury was addressed with open vascular repair via primary anastomosis supplemented with a bovine pericardial patch. LESSONS Complete aortic wall penetration from an excessively long thoracic pedicle screw with otherwise stable screw positioning may be addressed most effectively with a single anterior surgical approach for open aortic repair and screw tip burring.
Controversies in Spine Surgery
Bernatz, James T. , Fisher, Miles W.A. , Pinter, Zachariah W. , Sebastian, Arjun S. , Bernatz, James T.

Clinical Spine Surgery | February 2, 2023 | Volume: 36 | Issue: 6 | Pages: 224-226

10.1097/bsd.0000000000001416 Get It

Lower Hounsfield Units and Severe Multifidus Sarcopenia Are Independent Predictors of Increased Risk for Proximal Junctional Kyphosis and Failure Following Thoracolumbar Fusion
Pinter, Zachariah W. , Mikula, Anthony L. , Townsley, Sarah E., Lakomkin, Nikita , Michalopoulos, Giorgos D. , Freedman, Brett A. , Bydon, Mohamad , Fogelson, Jeremy L. , Sebastian, Arjun S. , Elder, Benjamin D. , Salmons Iv, Harold I, Fogelson, Jeremy, Michalopoulos, Giorgos , Salmons, Harold I. , Nassr, Ahmad

Spine | January 24, 2023 | Volume: 48 | Issue: 4 | Pages: 223-231

10.1097/brs.0000000000004517 Get It

Study Design. Retrospective cohort study. Objective. The purpose of the present study was to assess the impact of sarcopenia on the development of proximal junctional kyphosis (PJK) and proximal junctional failure (PJF) following thoracolumbar spine fusion surgery using opportunistic evaluation of paraspinal fatty degeneration on preoperative magnetic resonance imaging. Summary of Background Data. While paraspinal sarcopenia has been shown to have detrimental consequences following posterior cervicothoracic fusions, the impact of paraspinal sarcopenia on PJK and PJF following thoracolumbar spine fusion surgery remains unknown. Materials and Methods. We performed a retrospective review of patients who underwent posterior spine fusion surgery that extended caudally to the pelvis and terminated cranially between T10 and L2 between 2010 and 2017. The cohort was divided into three groups: (1) patients without PJK or PJF, (2) patients with PJK but no PJF, and (3) patients with PJF. Univariate and multivariate analyses were performed to determine risk factors for the development of proximal junctional complications. Results. We identified 150 patients for inclusion in this study. Mean Hounsfield Units at the upper instrumented vertebra (UIV) was 148.3±34.5 in the cohort of patients without PJK or PJF, which was substantially higher than values recorded in the PJK (117.8±41.9) and PJF (118.8±41.8) subgroups ( P <0.001). Severe multifidus sarcopenia was identified at a much higher rate in the subgroups of patients who developed PJK (76.0%) and PJF (78.9%) than in the subgroup of patients who developed neither PJK nor PJF (34.0%; P <0.001). Multivariate analysis demonstrated both low HU at the UIV and moderate-severe multifidus sarcopenia to be risk factors for the development of PJK and PJF. Conclusion. The results of this study suggest severe paraspinal sarcopenia and diminished bone density at the UIV impart an increased risk of developing PJK and PJF, while markers of systemic frailty such as modified Frailty Index and Charlson Comorbidity Index are not associated with an increased risk of these complications. Level of Evidence. III.
En bloc resection of a high cervical chordoma followed by reconstruction with a free vascularized fibular graft: illustrative case
Moore, Eric J. , Rose, Peter S. , Currier, Bradford L. , Pinter, Zachariah W. , Nassr, Ahmad

Journal of Neurosurgery: Case Lessons | December 19, 2022 | Volume: 4 | Issue: 25 | Pages: No page available

10.3171/case22305 Get It

BACKGROUND Wide excision of chordoma provides better local control than intralesional resection or definitive radiotherapy. The en bloc excision of high cervical chordomas is a challenging endeavor because of the complex anatomy of this region and limited reconstructive options. OBSERVATIONS This is the first case report to describe reconstruction with a free vascularized fibular graft following the en bloc excision of a chordoma involving C1–3. LESSONS This report demonstrates the durability of this construct at 10-year follow-up and is the first case report demonstrating satisfactory long-term oncological outcomes after a true margin-negative resection of a high cervical chordoma.
A Prospective Study of Lumbar Facet Arthroplasty in the Treatment of Degenerative Spondylolisthesis and Stenosis
Freedman, Brett A. , Sebastian, Arjun S. , Coric, Domagoj , Welch, William C. , Steinmetz, Michael P. , Robbins, Stephen E. , Ament, Jared D. , Anand, Neel , Baron, Eli M. , Whitmore, Robert G. , Whiting, Donald, Tahernia, David, Chahlavi, Ali, Chi, John, Pirris, Stephen M. , Groff, Michael W. , Fabi, Alain Y., Meyer, Scott A., Kushwaha, Vivek, Kent, Roland , DeLuca, Steven, Smorgick, Yossi , Anekstein, Yoram , Group, TOPS Study, Pinter, Zachariah W. , Nassr, Ahmad , Arnold, Paul M. , Huang, Jason Haitao , Sandhu, Faheem A. , Cheng, Joseph S. , Group, TOPS Study

Clinical Spine Surgery | October 3, 2022 | Volume: 36 | Issue: 2 | Pages: E59-E69

10.1097/bsd.0000000000001365 Get It

Study Design: Prospective randomized Food and Drug Administration investigational device exemption clinical trial. Objective: The purpose of the present study is to report the 1-year clinical and radiographic outcomes and safety profile of patients who underwent lumbar facet arthroplasty through implantation of the Total Posterior Spine System (TOPS) device. Summary of Background Data: Lumbar facet arthroplasty is one proposed method of dynamic stabilization to treat grade-1 spondylolisthesis with stenosis; however, there are currently no Food and Drug Administration-approved devices for facet arthroplasty. Methods: Standard demographic information was collected for each patient. Radiographic parameters and patient-reported outcome measures were assessed preoperatively and at regular postoperative intervals. Complication and reoperation data were also collected for each patient. Results: At the time of this study, 153 patients had undergone implantation of the TOPS device. The mean surgical time was 187.8 minutes and the mean estimated blood loss was 205.7cc. The mean length of hospital stay was 3.0 days. Mean Oswestry Disability Index, Visual Analog Score leg and back, and Zurich Claudication Questionnaire scores improved significantly at all postoperative time points (P>0.001). There were no clinically significant changes in radiographic parameters, and all operative segments remained mobile at 1-year follow-up. Postoperative complications occurred in 11 patients out of the 153 patients (7.2%) who underwent implantation of the TOPS device. Nine patients (5.9%) underwent a total of 13 reoperations, 1 (0.6%) of which was for device-related failure owing to bilateral L5 pedicle screw loosening. Conclusions: Lumbar facet arthroplasty with the TOPS device demonstrated a statistically significant improvement in all patient-reported outcome measures and the ability to maintain motion at the index level while limiting sagittal translation with a low complication rate.
Comparison of surgical interventions for the treatment of early-onset scoliosis: a systematic review and meta-analysis
Kim, Gloria, Sammak, Sally El , Michalopoulos, Giorgos D. , Freedman, Brett A. , Bydon, Mohamad , Mualem, William , Michalopoulos, Giorgos , Pinter, Zachariah W.

Journal of Neurosurgery: Pediatrics | September 23, 2022 | Volume: 31 | Issue: 4 | Pages: 342-357

10.3171/2022.8.peds22156 Get It

OBJECTIVE Several growth-preserving surgical techniques are employed in the management of early-onset scoliosis (EOS). The authors’ objective was to compare the use of traditional growing rods (TGRs), magnetically controlled growing rods (MCGRs), Shilla growth guidance techniques, and vertically expanding prosthetic titanium ribs (VEPTRs) for the management of EOS. METHODS A systematic review of electronic databases, including Ovid MEDLINE and Cochrane, was performed. Outcomes of interest included correction of Cobb angle, T1–S1 distance, and complication rate, including alignment, hardware failure and infection, and planned and unplanned reoperation rates. The percent changes and 95% CIs were pooled across studies using random-effects meta-analysis. RESULTS A total of 67 studies were identified, which included 2021 patients. Of these, 1169 (57.8%) patients underwent operations with TGR, 178 (8.8%) Shilla growth guidance system, 448 (22.2%) MCGR, and 226 (11.1%) VEPTR system. The mean ± SD age of the cohort was 6.9 ± 1.2 years. The authors found that the Shilla technique provided the most significant improvement in coronal Cobb angle immediately after surgery (mean [95% CI] 64.3% [61.4%–67.2%]), whereas VEPTR (27.6% [22.7%–33.6%]) performed significantly worse. VEPTR also performed significantly worse than the other techniques at final follow-up. The techniques also provided comparable gains in T1–S1 height immediately postoperatively (mean [95% CI] 10.7% [8.4%–13.0%]); however, TGR performed better at final follow-up (21.4% [18.7%–24.1%]). Complications were not significantly different among the patients who underwent the Shilla, TGR, MCGR, and VEPTR techniques, except for the rate of infections. The TGR technique had the lowest rate of unplanned reoperations (mean [95% CI] 15% [10%–23%] vs 24% [19%–29%]) but the highest number of planned reoperations per patient (5.31 [4.83–5.82]). The overall certainty was also low, with a high risk of bias across studies. CONCLUSIONS This analysis suggested that the Shilla technique was associated with a greater early coronal Cobb angle correction, whereas use of VEPTR was associated with a lower correction rate at any time point. TGR offered the most significant height gain at final follow-up. The complication rates were comparable across all surgical techniques. The optimal surgical approach should be tailored to individual patients, taking into consideration the strengths and limitations of each option.
Dynamic Radiographs Are Unreliable to Assess Arthrodesis Following Cervical Fusion: A Modeled Radiostereometric Analysis of Cervical Motion
Pinter, Zachariah W. , Skjaerlund, Jonathan, Michalopoulos, Giorgos D. , Bydon, Mohamad , Sebastian, Arjun S. , Freedman, Brett A. , Nathani, Karim R, Michalopoulos, Giorgos , Nathani, Karim Rizwan , Nassr, Ahmad

Spine | September 9, 2022 | Volume: 48 | Issue: 2 | Pages: 127-136

10.1097/brs.0000000000004470 Get It

Study Design. In vitro study. Objective. The purpose of the present study was to utilize an idealized cervical spine model to determine whether the parallax effect or changes in the position of the spine relative to the x-ray generator influence intervertebral motion parameters on dynamic cervical spine radiographs. Summary of Background Data. The utility of flexion-extension radiographs in clinical practice remains in question due to poor reliability of the parameters utilized to measure motion. Materials and Methods. A cervical spine model with tantalum beads inserted into the tip of each spinous process was utilized to measure interspinous process distance (IPD) on plain radiographs. The model was then manipulated to alter the generator angle and generator distance, and the IPD was measured. The impact of individual and combined changes in these parameters on IPD was assessed. Multivariate analysis was performed to identify independent drivers of variability in IPD measurements. Results. Isolated changes in the generator distance and generator angle and combined changes in these parameters led to significant changes in the measured IPD at each intervertebral level in neutral, flexion, and extension, which, in many instances, exceeded an absolute change of >1 mm or >2 mm. Multivariate analysis revealed that generator distance and generator angle are both independent factors impacting IPD measurements that have an additive effect. Conclusions. In an idealized cervical spine model, small clinically feasible changes in spine position relative to the x-ray generator produced substantial variability in IPD measurements, with absolute changes that often exceeded established cutoffs for determining the presence of pathologic motion across a fused segment. This study further reinforces that motion assessment on dynamic radiographs is not a reliable method for determining the presence of an arthrodesis unless these sources of variability can be consistently eliminated. Level of Evidence. 3