Preclinical testing platforms have been instrumental in the research and development of thrombectomy devices. However, there is no single model which fully captures the complexity of cerebrovascular anatomy, physiology, and the dynamic artery-clot-device interaction. This article provides a critical review of phantoms, in-vivo animal, and human cadaveric models used for thrombectomy testing and provides insights into the strengths and limitations of each platform. Articles published in the past 10 years that reported thrombectomy testing platforms were identified. Characteristics of each test platform, such as intracranial anatomy, artery tortuosity, vessel friction, flow conditions, device-vessel interaction, and visualization, were captured and benchmarked against human cerebral vessels involved in large-vessel occlusion stroke. Thrombectomy phantoms have been constructed from silicone, direct 3D-printed polymers, and glass. These phantoms represent oversimplified patient-specific cerebrovascular geometry but enable adequate visualization of devices and clots under appropriate flow conditions. They do not realistically mimic the artery-clot interaction. For the animal models, arteries from swine, canines, and rabbits have been reported. These models can reasonably replicate the artery-clot-device interaction and have the unique value of evaluating the safety of thrombectomy devices. However, the vasculature geometries are substantially less complex and flow conditions are different from human cerebral arteries. Cadaveric models are the most accurate vascular representations but with limited access and challenges in reproducibility of testing conditions. Multiple test platforms should be likely used for comprehensive evaluation of thrombectomy devices. Interpretation of the testing results should take into consideration platform-specific limitations.
Background To develop a preclinical thromboembolic occlusion model for studying revascularization strategies. Methods Clot analog with barium sulfate was injected into the distal aorta in 9 New Zealand white rabbits. The situation of aorta occlusion was compared among fibrin-rich (n=4), red blood cell (RBC)-rich (n=3), and whole blood clot analogs (n=2) using digital subtraction angiography. Arterial geometries, histologic features and circumferential stretch of the distal aorta in rabbits were compared with the common carotid artery in swine and the distal internal carotid artery (ICA) in humans. Aspiration thrombectomy and mechanical thrombectomy using a stent retriever were performed in two rabbits. Results The aortic bifurcation was occluded after a single delivery of clot in 4 cases. It was occluded after the second clot injection in the 5 remaining rabbits. Fragmentation of RBC-rich clots occurred during clot injection in 2 cases. The mean diameters of the distal aorta and right common iliac artery in rabbits were 3.7±0.4 and 2.8±0.3 mm, respectively; the mean diameters of human ICA, and first and second segments of the middle cerebral artery (M1, M2) were 3.6±0.4, 3.1±0.4, and 2.4±0.4 mm, respectively. Arterial revascularization was achieved in both rabbits. Geometric, mechanical and histological factors of the distal aorta in rabbit were more close to human distal ICA than swine carotid artery. Conclusion Arterial occlusion can be achieved at the aortic bifurcation in rabbits, which is comparable to human ICA bifurcation. This thrombectomy model has the potential to be used for testing of thrombectomy devices.
A human brain test bed for research in large vessel occlusion stroke
OBJECTIVE Endovascular removal of emboli causing large vessel occlusion (LVO)–related stroke utilizing suction catheter and/or stent retriever technologies or thrombectomy is a new standard of care. Despite high recanalization rates, 40% of stroke patients still experience poor neurological outcomes as many cases cannot be fully reopened after the first attempt. The development of new endovascular technologies and techniques for mechanical thrombectomy requires more sophisticated testing platforms that overcome the limitations of phantom-based simulators. The authors investigated the use of a hybrid platform for LVO stroke constructed with cadaveric human brains. METHODS A test bed for embolic occlusion of cerebrovascular arteries and mechanical thrombectomy was developed with cadaveric human brains, a customized hydraulic system to generate physiological flow rate and pressure, and three types of embolus analogs (elastic, stiff, and fragment-prone) engineered to match mechanically and phenotypically the emboli causing LVO strokes. LVO cases were replicated in the anterior and posterior circulation, and thrombectomy was attempted using suction catheters and/or stent retrievers. RESULTS The test bed allowed radiation-free visualization of thrombectomy for LVO stroke in real cerebrovascular anatomy and flow conditions by transmural visualization of the intraluminal elements and procedures. The authors were able to successfully replicate 105 LVO cases with 184 passes in 12 brains (51 LVO cases and 82 passes in the anterior circulation, and 54 LVO cases and 102 passes in the posterior circulation). Observed recanalization rates in this model were graded using a Recanalization in LVO (RELVO) scale analogous to other measures of recanalization outcomes in clinical use. CONCLUSIONS The human brain platform introduced and validated here enables the analysis of artery-embolus-device interaction under physiological hemodynamic conditions within the unmodified complexity of the cerebral vasculature inside the human brain.
Systematic review and meta-analysis of current rates of first pass effect by thrombectomy technique and associations with clinical outcomes
Background First pass effect (FPE) in mechanical thrombectomy is thought to be associated with good clinical outcomes. Objective To determine FPE rates as a function of thrombectomy technique and to compare clinical outcomes between patients with and without FPE. Methods In July 2020, a literature search on FPE (defined as modified Thrombolysis in Cerebral Infarction (TICI) 2c–3 after a single pass) and modified FPE (mFPE, defined as TICI 2b–3 after a single pass) and mechanical thrombectomy for stroke was performed. Using a random-effects meta-analysis, we evaluated the following outcomes for both FPE and mFPE: overall rates, rates by thrombectomy technique, rates of good neurologic outcome (modified Rankin Scale score ≤2 at day 90), mortality, and symptomatic intracerebral hemorrhage (sICH) rate. Results Sixty-seven studies comprising 16 870 patients were included. Overall rates of FPE and mFPE were 28% and 45%, respectively. Thrombectomy techniques shared similar FPE (p=0.17) and mFPE (p=0.20) rates. Higher odds of good neurologic outcome were found when we compared FPE with non-FPE (56% vs 41%, OR=1.78) and mFPE with non-mFPE (57% vs 44%, OR=1.73). FPE had a lower mortality rate (17% vs 25%, OR=0.62) than non-FPE. FPE and mFPE were not associated with lower sICH rate compared with non-FPE and non-mFPE (4% vs 18%, OR=0.41 for FPE; 5% vs 7%, OR=0.98 for mFPE). Conclusions Our findings suggest that approximately one-third of patients achieve FPE and around half of patients achieve mFPE, with equivalent results throughout thrombectomy techniques. FPE and mFPE are associated with better clinical outcomes.
Construction of a comprehensive endovascular test bed for research and device development in mechanical thrombectomy in stroke
OBJECTIVE The development of new endovascular technologies and techniques for mechanical thrombectomy in stroke has greatly relied on benchtop simulators. This paper presents an affordable, versatile, and realistic benchtop simulation model for stroke. METHODS A test bed for embolic occlusion of cerebrovascular arteries and mechanical thrombectomy was developed with 3D-printed and commercially available cerebrovascular phantoms, a customized hydraulic system to generate physiological flow rate and pressure, and 2 types of embolus analogs (elastic and fragment-prone) capable of causing embolic occlusions under physiological flow. RESULTS The test bed was highly versatile and allowed realistic, radiation-free mechanical thrombectomy for stroke due to large-vessel occlusion with rapid exchange of geometries and phantom types. Of the transparent cerebrovascular phantoms tested, the 3D-printed phantom was the easiest to manufacture, the glass model offered the best visibility of the interaction between embolus and thrombectomy device, and the flexible model most accurately mimicked the endovascular system during device navigation. None of the phantoms modeled branches smaller than 1 mm or perforating arteries, and none underwent realistic deformation or luminal collapse from device manipulation or vacuum. The hydraulic system created physiological flow rate and pressure leading to iatrogenic embolization during thrombectomy in all phantoms. Embolus analogs with known fabrication technique, structure, and tensile strength were introduced and consistently occluded the middle cerebral artery bifurcation under physiological flow, and their interaction with the device was accurately visualized. CONCLUSIONS The test bed presented in this study is a low-cost, comprehensive, realistic, and versatile platform that enabled high-quality analysis of embolus–device interaction in multiple cerebrovascular phantoms and embolus analogs.
Analysis of human emboli and thrombectomy forces in large-vessel occlusion stroke
OBJECTIVE This study’s purpose was to improve understanding of the forces driving the complex mechanical interaction between embolic material and current stroke thrombectomy devices by analyzing the histological composition and strength of emboli retrieved from patients and by evaluating the mechanical forces necessary for retrieval of such emboli in a middle cerebral artery (MCA) bifurcation model. METHODS Embolus analogs (EAs) were generated and embolized under physiological pressure and flow conditions in a glass tube model of the MCA. The forces involved in EA removal using conventional endovascular techniques were described, analyzed, and categorized. Then, 16 embolic specimens were retrieved from 11 stroke patients with large-vessel occlusions, and the tensile strength and response to stress were measured with a quasi-static uniaxial tensile test using a custom-made platform. Embolus compositions were analyzed and quantified by histology. RESULTS Uniaxial tension on the EAs led to deformation, elongation, thinning, fracture, and embolization. Uniaxial tensile testing of patients’ emboli revealed similar soft-material behavior, including elongation under tension and differential fracture patterns. At the final fracture of the embolus (or dissociation), the amount of elongation, quantified as strain, ranged from 1.05 to 4.89 (2.41 ± 1.04 [mean ± SD]) and the embolus-generated force, quantified as stress, ranged from 63 to 2396 kPa (569 ± 695 kPa). The ultimate tensile strain of the emboli increased with a higher platelet percentage, and the ultimate tensile stress increased with a higher fibrin percentage and decreased with a higher red blood cell percentage. CONCLUSIONS Current thrombectomy devices remove emboli mostly by applying linear tensile forces, under which emboli elongate until dissociation. Embolus resistance to dissociation is determined by embolus strength, which significantly correlates with composition and varies within and among patients and within the same thrombus. The dynamic intravascular weakening of emboli during removal may lead to iatrogenic embolization.