Back to Authors

Espy, Mark J.

Mayo Clinic

Mayo Clinic

Citations 47

Evaluation of LightCycler PCR for Implementation of Laboratory Diagnosis of Herpes Simplex Virus Infections
Espy, Mark J., Ross, Teri K., Teo, Rosaline, Svien, Kathleen A., Wold, Arlo D., Uhl, James R., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 8 | Pages: 3116-3118

10.1128/jcm.38.8.3116-3118.2000 Get It

ABSTRACT Five hundred specimens (288 genital, 192 dermal, and 20 ocular) were extracted by technologists, and the DNA was assayed by LightCycler PCR (DNA polymerase and thymidine kinase [TK] gene targets) and by conventional tube and shell vial cell culture. One hundred fifty-eight confirmed (by cell culture and TK target PCR) positive and LightCycler-positive specimens were detected during the first 30 PCR cycles. LightCycler PCR-positive results for cycles 31 to 45 (39 of 67 [58.2%]) required confirmation by another PCR target (TK). LightCycler PCR is more sensitive ( n = 197; 23.1%) than cell cultures ( n = 150) for the routine laboratory detection of herpes simplex virus infections.
Diagnosis of Herpes Simplex Virus Infections in the Clinical Laboratory by LightCycler PCR
Espy, Mark J., Uhl, James R., Mitchell, P. Shawn, Thorvilson, Jill N., Svien, Kathleen A., Wold, Arlo D., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 2 | Pages: 795-799

10.1128/jcm.38.2.795-799.2000 Get It

ABSTRACT Herpes simplex virus (HSV) causes several clinical manifestations in both normal and immunocompromised hosts; this agent is the most frequently detected virus in diagnostic laboratories. Recovery of the virus in cell culture is considered the “gold standard” for detection of this virus from sources other than cerebrospinal fluid. LightCycler is a newly developed, commercially available system designed to rapidly perform PCR, with real-time detection of PCR products by a fluorescence resonance energy transfer assay. We compared the detection of HSV for 200 specimens (number of genital specimens, 160; number of dermal specimens, 38; number of ocular specimens, 2) by shell vial cell cultures (MRC-5) and by LightCycler PCR. Of a total of 88 (44%) HSV strains detected, 69 (78%) were detected by both shell vial cell cultures and LightCycler PCR (DNA polymerase target). A total of 19 (22%) specimens were detected exclusively by LightCycler PCR. No specimens were positive by the shell vial assay only. All 19 discrepant samples had HSV DNA detected by an independent PCR directed to the thymidine kinase gene of the virus. The melting curve analysis feature of the LightCycler instrument identified identical genotype results for HSV type 1 (HSV-1) and HSV-2 from 84 of 88 (96%) positive samples. Specimens can be extracted, target HSV DNA can be amplified, and HSV PCR products can be identified by genotype within 2 h after receipt of specimen into the laboratory. The increased level of accurate identification (all 88 positive samples) compared with that of shell vial cell culture (69 of 88 samples identified as positive) and the agreement of LightCycler PCR results with all shell vial positive results indicate the potential for routine implementation of this technology for laboratory diagnosis of HSV infections.
Role of Genotypic Analysis of the Thymidine Kinase Gene of Herpes Simplex Virus for Determination of Neurovirulence and Resistance to Acyclovir
Lee, N. Y., Espy, Mark J., Kolbert, C. P., Rys, Paul N., Mitchell, P. Shawn, Henry, Semakula, Persing, David H., Smith, Thomas F., Tang, Yi‐Wei , Day, S. P.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3171-3174

10.1128/jcm.37.10.3171-3174.1999 Get It

ABSTRACT Mutations in the thymidine kinase (TK) gene of herpes simplex virus (HSV) have been associated with resistance to acyclovir (ACY) and possible recognition of neurotropic strains. We sequenced a 335-bp segment of the TK gene to determine the frequency of mutations in HSV strains recovered from dermal, genital, and cerebrospinal fluid (CSF) specimens ( n = 200; 102 HSV type 1 [HSV-1] 98 HSV-2 strains). Four polymorphic sites were detected in HSV-1 strains; C513T, A528G, C575T, and C672T. Among the polymorphisms, only C575T resulted in a change of amino acid sequence (residue 192, Ala→Val). For HSV-2 strains, only one polymorphism (G420T) which resulted in an amino acid substitution (residue 139, Leu→Phe) was detected. Phenotypic determination of resistance to ACY by a plaque reduction assay of 48 HSV isolates was not correlated with the sequence results of 11 strains in that 7 of these with genotypic polymorphisms were susceptible to the drug in vitro. In addition, of 32 ACY-resistant HSV strains, 28 (87.5%) had no polymorphisms detected in the 335-bp amplicon of the TK gene. There was no statistical difference in the frequency of polymorphisms according to the source of the specimens. We conclude that the detection of nucleic acid polymorphisms in a previously implicated 335-bp segment of the TK gene cannot be interpreted as indicative of either ACY resistance or neurotropism of HSV strains from dermal, genital, and CSF sources.
Assessment of Test Performance and Potential for Environmental Contamination Associated with a Point-of-Care Molecular Assay for Group A Streptococcus in an End User Setting
Myhre, Nikki K., Murray, Martha A. , McDonah, Margaret R. , Myers, Jane F., Maxson, Julie, Meek, Alicia M., Espy, Mark J., Furst, Joseph W. , Karon, Brad S. , Binnicker, Matthew J. , Donato, Leslie J. , Maxson, Julie A, Myhre, Nikki K.

Journal of Clinical Microbiology | December 4, 2018 | Volume: 57 | Issue: 2 | Pages: No page available

10.1128/jcm.01629-18 Get It

Although U.S. Food and Drug Administration-approved and CLIA-waived point-of-care (POC) molecular systems are being implemented in routine clinical practice, instrument reliability, test performance in the hands of end users, and the potential for environmental contamination resulting from use of POC molecular systems have not been extensively evaluated.
The Effect of Centrifugation on the Rapid Detection of Adenovirus in Shell Vials
Espy, Mark J., Hierholzer, John C., Smith, Thomas F.

American Journal of Clinical Pathology | March 17, 2016 | Volume: 88 | Issue: 3 | Pages: 358-360

10.1093/ajcp/88.3.358 Get It

Testing for Herpes Simplex Virus in Low-Volume Cerebrospinal Fluid Samples: Comparison of Three Protocols To Optimize Detection
Espy, Mark J., Irish, Cole L., Binnicker, Matthew J.

Journal of Clinical Microbiology | September 24, 2015 | Volume: 53 | Issue: 12 | Pages: 3897-3899

10.1128/jcm.02386-15 Get It

ABSTRACT Detection of herpes simplex virus 1 and 2 (HSV-1 and HSV-2) in cerebrospinal fluid (CSF) is a medical emergency and requires rapid, sensitive testing. However, the volume of CSF received for microbiological studies may be limited, especially from young children. In this study, we compared three testing protocols to our routine real-time PCR method to determine the most sensitive approach for detecting HSV-1 and HSV-2 in low-volume (≤100 μl) CSF.
Direct Detection of Influenza A and B Viruses in Less Than 20 Minutes Using a Commercially Available Rapid PCR Assay
Binnicker, Matthew J. , Espy, Mark J., Irish, Cole L., Vetter, Emily A.

Journal of Clinical Microbiology | April 30, 2015 | Volume: 53 | Issue: 7 | Pages: 2353-2354

10.1128/jcm.00791-15 Get It

ABSTRACT We compared an FDA-cleared rapid (<20 min) PCR assay (Cobas Liat; Roche Diagnostics) to our routine influenza A and B real-time PCR assay (Simplexa Flu A/B & RSV Direct; Focus Diagnostics) using respiratory swabs ( n = 197). The Cobas Liat influenza A and B assays demonstrated sensitivities of 99.2% (123/124) and 100% (23/23), respectively, while showing a specificity of 100% for each target.
Rapid and Direct Detection of Herpes Simplex Virus in Cerebrospinal Fluid by Use of a Commercial Real-Time PCR Assay
Binnicker, Matthew J. , Espy, Mark J., Irish, Cole L.

Journal of Clinical Microbiology | October 2, 2014 | Volume: 52 | Issue: 12 | Pages: 4361-4362

10.1128/jcm.02623-14 Get It

ABSTRACT Central nervous system infection due to herpes simplex virus (HSV) is a medical emergency and requires rapid diagnosis and initiation of therapy. In this study, we compared a routine real-time PCR assay for HSV types 1 (HSV-1) and 2 (HSV-2) to a recently FDA-approved direct PCR assay (Simplexa HSV-1/2 Direct; Focus Diagnostics, Cypress, CA) using cerebrospinal fluid samples ( n = 100). The Simplexa HSV-1/2 assays demonstrated a combined sensitivity and specificity of 96.2% (50/52) and 97.9% (47/48), respectively. In addition, the Simplexa assay does not require nucleic acid extraction, and the results are available in 60 min.
Comparative Evaluation of Three Commercial Systems for Detection of High-Risk Human Papillomavirus in Cervical and Vaginal ThinPrep PreservCyt Samples and Correlation with Biopsy Results
Binnicker, Matthew J. , Pritt, Bobbi S. , Duresko, Brian J., Espy, Mark J., Grys, Thomas E. , Zarka, Matthew A., Kerr, Sarah E. , Henry, Michael , Pritt, Bobbi S , Grys, Thomas E

Journal of Clinical Microbiology | August 14, 2014 | Volume: 52 | Issue: 10 | Pages: 3763-3768

10.1128/jcm.01928-14 Get It

ABSTRACT Genital human papillomavirus (HPV) is the etiologic agent of more than 99% of all cervical cancers worldwide, with 14 genotypes being considered oncogenic or “high risk” because of their association with severe dysplasia and cervical carcinoma. Among these 14 high-risk types, HPV-16 and -18 account for approximately 70% of cervical cancers. The aim of this study was to evaluate three FDA-approved HPV nucleic acid-based tests for the ability to predict high-grade cervical intraepithelial neoplasias (CIN2 or worse) in corresponding tissue biopsy specimens. Residual specimens (total n = 793, cervical n = 743, vaginal n = 50) collected in ThinPrep PreservCyt medium with a cytologic result of ≥atypical squamous cells of undetermined significance were tested by the Hybrid Capture 2 (HC2) assay (Qiagen, Gaithersburg, MD), the cobas HPV test (Roche Diagnostics, Indianapolis, IN), and the APTIMA HPV assay (Hologic, San Diego, CA). Genotyping for HPV-16 and HPV-18 was simultaneously performed by the cobas HPV test. Results were compared to cervical or vaginal biopsy findings, when they were available ( n = 350). Among the 350 patients with corresponding biopsy results, 81 (23.1%) showed ≥CIN2 by histopathology. The ≥CIN2 detection sensitivity was 91.4% by the cobas and APTIMA assays and 97.5% by HC2 assay. The specificities of the cobas, APTIMA, and HC2 assays were 31.2, 42.0, and 27.1%, respectively. When considering only positive HPV-16 and/or HPV-18 genotype results, the cobas test showed a sensitivity and a specificity of 51.9 and 86.6%, respectively. While the HC2, cobas, and APTIMA assays showed similar sensitivities for the detection of ≥CIN2 lesions, the specificities of the three tests varied, with the greatest specificity (86.6%) observed when the HPV-16 and/or HPV-18 genotypes were detected.
Comparative Evaluation of Two Commercial Multiplex Panels for Detection of Gastrointestinal Pathogens by Use of Clinical Stool Specimens
Khare, Reeti , Espy, Mark J., Cebelinski, Elizabeth , Boxrud, David, Sloan, Lynne M., Cunningham, Scott A. , Pritt, Bobbi S. , Patel, Robin , Binnicker, Matthew J. , Patel, Robin , Pritt, Bobbi S , Cunningham, Scott A

Journal of Clinical Microbiology | August 7, 2014 | Volume: 52 | Issue: 10 | Pages: 3667-3673

10.1128/jcm.01637-14 Get It

ABSTRACT The detection of pathogens associated with gastrointestinal disease may be important in certain patient populations, such as immunocompromised hosts, the critically ill, or individuals with prolonged disease that is refractory to treatment. In this study, we evaluated two commercially available multiplex panels (the FilmArray gastrointestinal [GI] panel [BioFire Diagnostics, Salt Lake City, UT] and the Luminex xTag gastrointestinal pathogen panel [GPP] [Luminex Corporation, Toronto, Canada]) using Cary-Blair stool samples ( n = 500) submitted to our laboratory for routine GI testing (e.g., culture, antigen testing, microscopy, and individual real-time PCR). At the time of this study, the prototype (non-FDA-cleared) FilmArray GI panel targeted 23 pathogens (14 bacterial, 5 viral, and 4 parasitic), and testing of 200 μl of Cary-Blair stool was recommended. In contrast, the Luminex GPP assay was FDA cleared for the detection of 11 pathogens (7 bacterial, 2 viral, and 2 parasitic), but had the capacity to identify 4 additional pathogens using a research-use-only protocol. Importantly, the Luminex assay was FDA cleared for 100 μl raw stool; however, 100 μl Cary-Blair stool was tested by the Luminex assay in this study. Among 230 prospectively collected samples, routine testing was positive for one or more GI pathogens in 19 (8.3%) samples, compared to 76 (33.0%) by the FilmArray and 69 (30.3%) by the Luminex assay. Clostridium difficile (12.6 to 13.9% prevalence) and norovirus genogroup I (GI)/GII (5.7 to 13.9% prevalence) were two of the pathogens most commonly detected by both assays among prospective samples. Sapovirus was also commonly detected (5.7% positive rate) by the FilmArray assay. Among 270 additional previously characterized samples, both multiplex panels demonstrated high sensitivity (>90%) for the majority of targets, with the exception of several pathogens, notably Aeromonas sp. (23.8%) by FilmArray and Yersinia enterocolitica (48.1%) by the Luminex assay. Interestingly, the FilmArray and Luminex panels identified mixed infections in 21.1% and 13.0% of positive prospective samples, respectively, compared to only 8.3% by routine methods.