Back to Authors

Saoji, Aniket A.

0009-0001-0318-1770

Mayo Clinic

Mayo Clinic

Citations 39

Speech Perception Performance Growth and Benchmark Score Achievement After Cochlear Implantation for Single-Sided Deafness
Nassiri, Ashley M. , Wallerius, Katherine P. , Lohse, Christine M. , Marinelli, John P. , Saoji, Aniket A. , Driscoll, Colin L. W., Neff, Brian A., Carlson, Matthew L.

Otology & Neurotology | December 10, 2021 | Volume: 43 | Issue: 1 | Pages: e64-e71

10.1097/mao.0000000000003407 Get It

Objectives: Compare speech perception performance growth and benchmark score achievement among adult cochlear implant (CI) recipients with single-sided deafness (SSD) versus bilateral moderate to profound hearing loss. Study Design: Retrospective matched cohort analysis. Setting: Tertiary referral center. Patients: Adults with SSD or bilateral moderate to profound hearing sensorineural hearing loss who underwent cochlear implantation from 2014 to 2019. Interventions: Cochlear implantation. Main outcome measures: Time-to-benchmark speech perception score (CNC, AzBio in quiet) and speech performance within first postoperative year. Results: Thirty-three SSD patients were matched to 66 bilateral hearing loss patients (referent cohort) for duration of deafness and preoperative ipsilateral CNC scores. Although SSD patients were more likely to achieve benchmark CNC scores more quickly compared with matched referents, this difference did not reach statistical significance (HR 1.72; 95% CI 0.78–3.82; p = 0.18). AzBio scores showed similar trends (HR 1.40; 95% CI 0.66–2.98; p = 0.38). At last follow-up, the SSD cohort had lower CNC (median 54% vs. 62%; p = 0.019) and AzBio scores (median 72% vs. 84%; p = 0.029) compared to the referent cohort. Conclusions: No significant difference in speech perception performance growth (i.e., time-to-benchmark speech perception score) was identified between SSD and bilateral hearing loss CI recipients, although patients with bilateral hearing loss achieved higher scores in the implanted ear within the first year of follow-up.
Does early activation within hours after cochlear implant surgery influence electrode impedances?
Saoji, Aniket A. , Adkins, Weston J., Graham, Madison K., Carlson, Matthew L.

International Journal of Audiology | July 18, 2021 | Volume: 61 | Issue: 6 | Pages: 520-525

10.1080/14992027.2021.1942569 Get It

Assessment of Pediatric Middle Ear Effusions With Wideband Tympanometry
Callaham, Sarah , Newby, Maxwell , Saoji, Aniket A. , Ramadan, Jad , Carr, Michele M.

Otolaryngology–Head and Neck Surgery | December 10, 2020 | Volume: 165 | Issue: 3 | Pages: 465-469

10.1177/0194599820978262 Get It

ObjectiveTo determine if wideband tympanometry (WBT) can differentiate types of middle ear effusion (MEE): serous, mucoid, and purulent.Study DesignProspective cohort study.SettingTertiary care children’s hospital.MethodsChildren who met American Academy of Otolaryngology–Head and Neck Surgery’s guidelines for ventilation tube insertion had WBT after anesthesia induction but before tympanotomy. MEE was categorized into 1 of 4 comparison groups: serous effusion, mucoid effusion, purulent effusion, or no effusion. WBT measurements were averaged to 16 one‐third octave frequency bands, and comparison of the absorbance patterns for each MEE type was performed through a linear mixed effects model.ResultsA total of 118 children (211 ears) were included: 47 females (39.8%) and 71 males (60.2%). The mean age was 2.73 years (95% CI, 2.25‐3.22); mean weight, 14.35 kg (95% CI, 12.85‐15.85); and mean Z score, 1.13 (95% CI, –0.64 to 2.33). Effusions included 61 mucoid (28.9%), 30 purulent (14.2%), and 14 serous (6.6%), with 106 (50.2%) having no effusion. No significant differences were found for sex, race, age, weight, or Z score among the 4 types of effusion (P <. 05). WBT showed a significant difference in median absorption among the effusion groups (P <. 001), with a medium effect size of 0.35.ConclusionsWBT has potential use to differentiate types of MEE and should be studied further as a tool for investigating how the natural history and management of serous and mucoid effusions may differ.
Increase in cochlear implant electrode impedances with the use of electrical stimulation
Saoji, Aniket A. , Adkins, Weston J., Olund, Amy P., Graham, Madison, Patel, Neil S. , Neff, Brian A., Carlson, Matthew L. , Driscoll, Colin L. W., Graham, Madison

International Journal of Audiology | August 4, 2020 | Volume: 59 | Issue: 11 | Pages: 881-888

10.1080/14992027.2020.1799251 Get It

Electrocochleography in cochlear implantation: Development, applications, and future directions
Barnes, Jason H. , Saoji, Aniket A. , Carlson, Matthew L. , Yin, Linda X.

World Journal of Otorhinolaryngology - Head and Neck Surgery | June 4, 2020 | Volume: 7 | Issue: 2 | Pages: 94-100

10.1016/j.wjorl.2020.04.006 Get It

Electrocochleography (ECochG) is an electrophysiological technique that records electrical potentials generated by different components of the inner ear and peripheral cochlear nerve in response to acoustic stimulation. ECochG responses can be analyzed into (1) cochlear microphonics (CM), (2) auditory nerve neurophonics, (3) summating potential, and (4) compound action potential. Over the past few decades, there have been ongoing refinements in technique and updates in the understanding of recorded potentials. Historically, ECochG found its main application in the diagnostic evaluation of Meniere's disease (MD). However, in the last decade, the focus has shifted towards cochlear implantation (CI). In patients with residual hearing after CI, combined electric and acoustic stimulation has resulted in improved hearing and speech outcomes. Despite efforts to mitigate trauma during electrode insertion, hearing preservation rates vary after surgery. During implantation, real‐time ECochG offers an opportunity to measure frequency specific CMs elicited from a localized region in the cochlea as the surgeon inserts the electrode array. In extracochlear ECochG recordings, the recording electrode can be placed on the promontory, the stapes, or the tympanic membrane. Intracochlear ECochG can be performed by inserting a recording electrode into the cochlea or by using one of the CI electrodes as the recording electrode. The loss of intraoperative ECochG signal may indicate cochlear trauma from electrode insertion, but the association between intraoperative ECochG changes and cochlear trauma remains controversial. The ability to monitor cochlear trauma during CI electrode placement holds promise to improve hearing preservation outcomes, modify surgical techniques, and change electrode design. The goal of this review is to provide a comprehensive overview of the electrophysiology and history of ECochG, discuss its recent applications in CI, and explore the ongoing research in this expanding field.
Comparison of Pure-Tone Thresholds and Cochlear Microphonics Thresholds in Pediatric Cochlear Implant Patients
Coulthurst, Sarah, Nachman, Alison Judith, Murray, Mike T., Koka, Kanthaiah , Saoji, Aniket A.

Ear & Hearing | April 25, 2020 | Volume: 41 | Issue: 5 | Pages: 1320-1326

10.1097/aud.0000000000000870 Get It

Objectives: In adult cochlear implant patients, conventional audiometry is used to measure postoperative residual hearing which requires active listening and patient feedback. However, audiological measurements in pediatric cochlear implant patients are both challenging as well as time consuming. Intracochlear electrocochleography (ECOG) offers an objective and a time-efficient method to measure frequency-specific cochlear microphonic or difference thresholds (CM/DIF) thresholds that closely approximate auditory thresholds in adult cochlear implant patients. The correlation between CM/DIF and behavioral thresholds has not been established in pediatric cochlear implant patients. In the present study, CM/DIF thresholds were compared with audiometric thresholds in pediatric cochlear implant patients with postoperative residual hearing. Design: Thirteen (11 unilateral and 2 bilateral) pediatric cochlear implant patients (mean age = 9.2 years ± 5.1) participated in this study. Audiometric thresholds were estimated using conventional, condition play, or visual reinforcement audiometry. A warble tone stimulus was used to measure audiometric thresholds at 125, 250, 500, 1000, and 2000 Hz. ECOG waveforms were elicited using 50-msec acoustic tone-bursts. The most apical intracochlear electrode was used as the recording electrode with an extra-cochlear ground electrode. The ECOG waveforms were analyzed to determine CM/DIF thresholds that were compared with pediatric cochlear implant patients’ audiometric thresholds. Results: The results show a significant correlation (r = 0.77, p < 0.01) between audiometric and CM/DIF thresholds over a frequency range of 125 to 2000 Hz in pediatric cochlear implant patients. Frequency-specific comparisons revealed a correlation of 0.82, 0.74, 0.69, 0.41, and 0.32 between the audiometric thresholds and CM/DIF thresholds measured at 125, 250, 500, 1000, and 2000 Hz, respectively. An average difference of 0.4 dB (±14 dB) was measured between the audiometric and CM/DIF thresholds. Conclusions: Intracochlear ECOG can be used to measure CM/DIF thresholds in pediatric cochlear implant patients with residual hearing in the implanted ear. The CM/DIF thresholds are similar to the audiometric thresholds at lower test frequencies and offer an objective method to monitor residual hearing in difficult-to-test pediatric cochlear implant patients.
Changes in Wide-band Tympanometry Absorbance Following Cochlear Implantation
Saoji, Aniket A. , Shapiro, Scott , Finley, Charles C., Koka, Kanthaiah , Cassis, Adam

Otology & Neurotology | March 28, 2020 | Volume: 41 | Issue: 6 | Pages: e680-e685

10.1097/mao.0000000000002625 Get It

Objective: Determine if changes in middle ear absorbance measured with wide-band tympanometry (WBT) occur following hearing-preservation cochlear implantation (CI). Such measures may provide insight into the mechanisms of acoustic hearing loss postimplantation. Study Design: Clinical capsule report. Setting: Tertiary academic referral center. Design: WBT absorbance was measured bilaterally during pre- and postoperative clinical office visits in five unilaterally-implanted cochlear implant recipients. Pre- and postoperative WBT measures were compared within each subject in the implanted and contralateral, unimplanted ears. Results: In general, WBT absorbance measurements show a broad spectral pattern including two or three distinct peaks measured over a frequency range of 226 to 8000 Hz. Grand average and linear mixed model comparisons between the pre- and postoperative WBT patterns show significantly reduced (p < 0.05) low-frequency absorbance in the implanted ears in the frequency region over 0.6 to 1.1 kHz, but not in the unimplanted ears. The maximum effect occurred at 1 kHz with absorbance decreasing from ∼0.8 to ∼0.5 after implantation. The limited data are consistent with expected relationships between WBT absorbance and air- and bone-conduction thresholds, assuming an increased air-bone gap reflects conductive hearing loss. Conclusion: Cochlear implantation can result in reduction of low-frequency acoustic absorbance as measured by WBT. WBT may be a useful and sensitive tool for monitoring the mechanical status of the middle and inner ears following cochlear implantation.
Monitoring Cochlear Nerve Integrity During Vestibular Schwannoma Microsurgery in Real-Time Using Cochlear Implant Evoked Auditory Brainstem Response and Streaming Neural Response Imaging
Patel, Neil , Saoji, Aniket A. , Olund, Amy P., Carlson, Matthew L.

Otology & Neurotology | January 10, 2020 | Volume: 41 | Issue: 2 | Pages: e201-e207

10.1097/mao.0000000000002458 Get It

Objective: Intraoperative far-field auditory brainstem response (ABR) and direct cochlear nerve action potential monitoring using neural response imaging (NRI) are techniques for monitoring the cochlear nerve during vestibular schwannoma (VS) surgery. A new paradigm has developed where the cochlear nerve is anatomically preserved during tumor removal to facilitate cochlear implantation in select circumstances. This report describes the use of an unmodified commercial cochlear implant (CI) to elicit electrically-evoked direct cochlear nerve and far-field ABR monitoring to evaluate the status of the cochlear nerve during tumor resection in real time. Patients: Adult female with unilateral, sporadic VS. Intervention(s): Cochlear implantation followed by translabyrinthine resection of VS in single operation. Main Outcome Measures: During tumor resection intra-cochlear electrodes were used to deliver electrical stimulation and measure NRI or the cochlear nerve action potential. Electrically-evoked ABR (eABR) was measured using surface electrodes and wave V was monitored (far-field ABR) during surgery. Results: A 61-year-old female was evaluated for a unilateral, enlarging intracanalicular VS with asymmetric SNHL. The patient opted for microsurgery and due to her bilateral hearing loss was a candidate for CI. Cochlear implantation with an unmodified, commercially available lateral wall electrode was performed. The remainder of the approach and tumor resection was performed under continuous eABR and NRI monitoring. Gross total resection was achieved with intact eABR and NRI at the conclusion of the case. Changes in ABR and NRI consistently recovered after modifying dissection strategy. The patient reported auditory percepts with her cochlear implant postoperatively. Conclusions: This report demonstrates the feasibility of using real-time NRI and eABR with a CI to facilitate preservation of the cochlear nerve during VS microsurgery. Using this method to mitigate cochlear nerve trauma during microsurgery may preserve the option of CI for hearing rehabilitation.
Multi-frequency Electrocochleography Measurements can be Used to Monitor and Optimize Electrode Placement During Cochlear Implant Surgery
Saoji, Aniket A. , Patel, Neil S. , Carlson, Matthew L. , Neff, Brian A., Koka, Kanthaiah , Tarigoppula, Venkata S Aditya , Driscoll, Colin L. W.

Otology & Neurotology | October 23, 2019 | Volume: 40 | Issue: 10 | Pages: 1287-1291

10.1097/mao.0000000000002406 Get It

Objective: To report the use of multi-frequency intra-cochlear electrocochleography (ECOG) in monitoring and optimizing electrode placement during cochlear implant surgery. An acoustic pure tone complex comprising of 250, 500, 1000, and 2000 Hz was used to elicit ECOG, or more specifically cochlear microphonics (CMs), responses from various locations in the cochlea. The most apical cochlear implant electrode was used as the recording electrode. Study Design: Clinical capsule report. Setting: Tertiary academic referral center. Results: ECOG measurements were performed during cochlear implant surgery in an adult patient with significant residual acoustic hearing. The 500, 1000, and 2000 Hz CM tracings from the most apical electrode showed an amplitude peak at three different instances during the early phase of cochlear implant electrode insertion. These results are consistent with the tonotopic organization of the cochlea. During final electrode placement a slight advancement of the electrode array resulted in a correlated decrease in 250, 500, and/or 1000 Hz CM amplitude. The electrode array was retracted and repositioned which resulted in a recovery of CM amplitude. Intraoperative CM thresholds revealed a correlation of r = 0.87 with preoperative audiometric thresholds. Conclusion: We present a report on simultaneous multi-frequency ECOG monitoring during cochlear implant surgery. Multi-frequency ECOG can be used to differentiate between electrode trauma and the advancement of the apical electrode beyond the CM source in the cochlea.