Back to Authors

Adkins, Weston J.

Mayo Clinic

Mayo Clinic

Citations 4

Multi-Frequency Electrocochleography and Electrode Scan to Identify Electrode Insertion Trauma during Cochlear Implantation
Saoji, Aniket A. , Graham, Madison K., Adkins, Weston J., Koka, Kanthaiah , Carlson, Matthew L. , Neff, Brian A., Driscoll, Colin L. W., Fitzpatrick, Douglas C.

Brain Sciences | February 15, 2023 | Volume: 13 | Issue: 2 | Pages: 330

10.3390/brainsci13020330 Get It

Intraoperative electrocochleography (ECOG) is performed using a single low-frequency acoustic stimulus (e.g., 500 Hz) to monitor cochlear microphonics (CM) during cochlear implant (CI) electrode insertion. A decrease in CM amplitude is commonly associated with cochlear trauma and is used to guide electrode placement. However, advancement of the recording electrode beyond the sites of CM generation can also lead to a decrease in CM amplitude and is sometimes interpreted as cochlear trauma, resulting in unnecessary electrode manipulation and increased risk of cochlear trauma during CI electrode placement. In the present study, multi-frequency ECOG was used to monitor CM during CI electrode placement. The intraoperative CM tracings were compared with electrode scan measurements, where CM was measured for each of the intracochlear electrodes. Comparison between the peak CM amplitude measured during electrode placement and electrode scan measurements was used to differentiate between different mechanisms for decrease in CM amplitude during CI electrode insertion. Analysis of the data shows that both multi-frequency electrocochleography and electrode scan could potentially be used to differentiate between different mechanisms for decreasing CM amplitude and providing appropriate feedback to the surgeon during CI electrode placement.
Does early activation within hours after cochlear implant surgery influence electrode impedances?
Saoji, Aniket A. , Adkins, Weston J., Graham, Madison K., Carlson, Matthew L.

International Journal of Audiology | July 18, 2021 | Volume: 61 | Issue: 6 | Pages: 520-525

10.1080/14992027.2021.1942569 Get It

Increase in cochlear implant electrode impedances with the use of electrical stimulation
Saoji, Aniket A. , Adkins, Weston J., Olund, Amy P., Graham, Madison, Patel, Neil S. , Neff, Brian A., Carlson, Matthew L. , Driscoll, Colin L. W., Graham, Madison

International Journal of Audiology | August 4, 2020 | Volume: 59 | Issue: 11 | Pages: 881-888

10.1080/14992027.2020.1799251 Get It

Cochlear Implantation in Craniometaphyseal Dysplasia
Huang, Alice E. , Adkins, Weston J., Patel, Neil

Otology & Neurotology | November 17, 2019 | Volume: 41 | Issue: 3 | Pages: e317-e321

10.1097/mao.0000000000002504 Get It

Objective: Describe the first case of cochlear implantation (CI) for auditory rehabilitation of a patient with craniometaphyseal dysplasia (CMD) and progressive mixed hearing loss. Patients: A 65-year-old woman with known autosomal dominant CMD presented with progressive mixed hearing loss and declining benefit from conventional hearing aids. Computed tomography and magnetic resonance imaging revealed hyperostosis of the entire craniofacial skeleton. Hearing evaluation demonstrated pure-tone thresholds in the profound range bilaterally by air conduction, and bone conduction thresholds that matched aided thresholds for her left ear, though testing was somewhat limited by inability to mask at high air-conduction thresholds. CI candidacy testing confirmed poor word and sentence scores in the right ear. Intervention: Due to the inability to access the cochlea via a conventional mastoidectomy and facial recess approach, cochlear implantation via a postauricular subtotal petrosectomy approach with ear canal overclosure was performed. Main Outcome Measures: Post-implantation word and sentence testing. Results: Despite extensive internal auditory canal stenosis, the patient demonstrated excellent early speech understanding results 5 weeks after device activation. Postimplantation audiologic evaluation showed thresholds between 20 and 30 dB HL from 250 to 6000 Hz. Word and sentence testing scores were 76% Consonant-nucleus-consonant in quiet (up from 2% preoperatively) and 77% AzBio sentences in quiet (up from 10% preoperatively). Conclusion: This report describes the first description of CI for CMD. Despite the extensive radiologic abnormalities, the patient has demonstrated excellent benefit from implantation. Further study of rare temporal bone dysplasias, such as CMD, is critical to better characterize the progression of otologic disease and determine optimal treatment.