Back to Authors

Binnicker, Matthew J.

https://orcid.org/0000-0003-2537-7165

Mayo Clinic

Mayo Clinic

Citations 55

Comparison of Respiratory Pathogen Detection in Upper versus Lower Respiratory Tract Samples Using the BioFire FilmArray Respiratory Panel in the Immunocompromised Host
Azadeh, Natalya , Sakata, Kenneth K. , Saeed, A.I. , Mullon, John J., Grys, Thomas E. , Binnicker, Matthew J. , Saeed, Ali, Limper, Andrew H. , Grys, Thomas E

Canadian Respiratory Journal | April 5, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-6

10.1155/2018/2685723 Get It

Background. The FilmArray Respiratory Panel (FARP) (BioFire Diagnostics, Inc.) is a multiplex, polymerase chain reaction (PCR) technique that can detect 17 respiratory viruses and 3 bacterial targets in a single reaction. Immunocompromised hosts (ICH) with respiratory illnesses often undergo bronchoscopy with bronchoalveolar lavage (BAL). This prospective study aimed to evaluate the yield and concordance of NP and BAL FARP testing when performed on the same patient concurrently. Methods. From February to December 2016, 125 patients (100 ICH and 25 non-ICH) were enrolled. NP swabs and BAL samples were sent for FARP testing. Results. The yield of the BAL FARP among ICH and non-ICH was 24% (24/100) and 8% (2/25), respectively. The yield of positive NP swabs in ICH was 27% (27/100) versus 4% (1/25) in non-ICH. The majority of patients (89%; 111/125) had concordant results between NP and BAL specimens. Of the 24 ICH patients who had a positive BAL FARP, the majority (79%) had the same pathogen detected from the NP swab. Conclusion. The FARP may be useful in the ICH. Given the high concordance, in patients whom a pathogen is identified on the NP FARP, a FARP performed on BAL will likely yield the same result. However, if the NP FARP is negative, performing the test on a BAL sample may have an incremental yield.
Evaluation of a Commercial Multiplex Molecular Panel for Diagnosis of Infectious Meningitis and Encephalitis
Liesman, Rachael M. , Strasburg, Angela P., Heitman, Angela K., Theel, Elitza S. , Patel, Robin , Binnicker, Matthew J. , Patel, Robin

Journal of Clinical Microbiology | February 8, 2018 | Volume: 56 | Issue: 4 | Pages: No page available

10.1128/jcm.01927-17 Get It

ABSTRACT Rapid and accurate laboratory tests are important for the timely diagnosis and treatment of central nervous system infections. The FilmArray meningitis/encephalitis (ME) panel (BioFire Diagnostics, Salt Lake City, UT) is an FDA-cleared, multiplex molecular panel that allows the detection of 14 pathogens (bacterial [ n = 6], viral [ n = 7], and fungal [ n = 1] pathogens) from cerebrospinal fluid (CSF). In this study, we evaluated the performance characteristics of the FilmArray ME panel using clinical, residual CSF samples ( n = 291) that tested positive by a routine method(s) (e.g., bacterial culture, individual real-time PCR assay) for a pathogen represented on the ME panel. Of note, a subset ( n = 76) of the CSF specimens was collected during the prevaccine era and had been characterized as positive for a bacterial pathogen. The FilmArray ME panel demonstrated an overall percent positive agreement (PPA) of 97.5% (78/80) for bacterial pathogens, 90.1% (145/161) for viruses, and 52% (26/50) for Cryptococcus neoformans/C. gattii . Despite the low overall agreement (52%) between the ME panel and antigen testing for detection of C. neoformans/C. gattii , the percent positive agreement of the FilmArray assay for C. neoformans/C. gattii was 92.3% (12/13) when the results were compared directly to the results of routine fungal smear or culture. The FilmArray ME panel offers a rapid (∼60-min), syndrome-based approach for the detection of select meningitis and encephalitis pathogens.
Syndromic Panel-Based Testing in Clinical Microbiology
Ramanan, Poornima , Bryson, Alexandra , Binnicker, Matthew J. , Pritt, Bobbi S. , Patel, Robin , Bryson, Alexandra L, Patel, Robin , Pritt, Bobbi S

Clinical Microbiology Reviews | November 15, 2017 | Volume: 31 | Issue: 1 | Pages: No page available

10.1128/cmr.00024-17 Get It

SUMMARY The recent development of commercial panel-based molecular diagnostics for the rapid detection of pathogens in positive blood culture bottles, respiratory specimens, stool, and cerebrospinal fluid has resulted in a paradigm shift in clinical microbiology and clinical practice. This review focuses on U.S. Food and Drug Administration (FDA)-approved/cleared multiplex molecular panels with more than five targets designed to assist in the diagnosis of bloodstream, respiratory tract, gastrointestinal, or central nervous system infections. While these panel-based assays have the clear advantages of a rapid turnaround time and the detection of a large number of microorganisms and promise to improve health care, they present certain challenges, including cost and the definition of ideal test utilization strategies (i.e., optimal ordering) and test interpretation.
Cytomegalovirus (CMV) DNA quantification in bronchoalveolar lavage fluid of immunocompromised patients with CMV pneumonia
Beam, Elena , Germer, Jeffrey J., Lahr, Brian D. , Yao, Joseph D. , Binnicker, Matthew J. , Lahr, Brian, Yao, Joseph D C, Limper, Andrew Harold, Beam, Elena , Limper, Andrew H. , Razonable, Raymund R.

Clinical Transplantation | November 7, 2017 | Volume: 32 | Issue: 1 | Pages: No page available

10.1111/ctr.13149 Get It

AbstractCytomegalovirus (CMV) pneumonia causes major morbidity and mortality. Its diagnosis requires demonstration of viral cytopathic changes in tissue, entailing risks of lung biopsy. This study aimed to determine CMV viral load (VL) thresholds in bronchoalveolar lavage fluid (BALF) for diagnosis of CMV pneumonia in immunocompromised patients. CMV VL in BALF was studied in 17 patients (83% transplant recipients) and 21 control subjects with and without CMV pneumonia, respectively, using an FDA‐approved PCR assay (Cobas® AmpliPrep/Cobas TaqMan® CMV Test, Roche Molecular Systems, Inc.) calibrated to the WHO International Standard for CMV DNA (NIBSC: 09/162). Receiver operating characteristic curve analysis produced a BALF CMV VL threshold of 34 800, IU/mL with 91.7% sensitivity and 100.0% specificity for diagnosis of possible, probable, and proven CMV pneumonia in transplant patients, while a threshold of 656 000 IU/mL yielded 100% sensitivity and specificity among biopsy‐proven cases. For all immunocompromised patients, a VL threshold of 274 IU/mL was selected. VL thresholds also were normalized to BALF cell count yielding a threshold of 0.32 IU/106 cells with 91.7% sensitivity and 90.5% specificity for possible, probable, and proven CMV pneumonia in transplant recipients. Monitoring CMV VL in BALF may be a less invasive method for diagnosing CMV pneumonia in immunocompromised patients.
A kidney transplant recipient with renal medullary viral cytopathic changes
Ramanan, Poornima , Timmerman, Elizabeth A., Fidler, Mary E., Amer, Hatem , Pritt, Bobbi S. , Schwab, Dale A. , Batterman, Hollis J., Binnicker, Matthew J. , Amer, Hatem , Pritt, Bobbi S

Transplant Infectious Disease | December 7, 2016 | Volume: 19 | Issue: 1 | Pages: No page available

10.1111/tid.12646 Get It

AbstractWe present a case of JC polyomavirus (JCV)‐associated nephropathy (PyVAN) in an asymptomatic deceased‐donor kidney transplant recipient. Despite the presence of viral cytopathic effect in the kidney biopsy and positive BK polyomavirus (BKV) in situ hybridization (ISH), BKV real‐time polymerase chain reaction (PCR) results of plasma and urine were negative. JCV ISH was performed and was found to be positive. JCV real‐time PCR on urine, plasma, and the kidney biopsy tissue was positive. Reduction in immunosuppression resulted in resolution of JCV viremia. This case highlights that JC‐PyVAN is a distinct clinical entity and is likely to have a better clinical outcome than BK‐PyVAN. Concurrent infection with BKV and JCV may occur, but may be difficult to confirm due to the potential for cross‐reactivity between BKV and JCV ISH stains.
CSF herpes virus and autoantibody profiles in the evaluation of encephalitis
Linnoila, Jenny, Binnicker, Matthew J. , Majed, Masoud , Linnoila, Jenny J, Klein, Christopher J. , McKeon, Andrew

Neurology Neuroimmunology & Neuroinflammation | June 2, 2016 | Volume: 3 | Issue: 4 | Pages: No page available

10.1212/nxi.0000000000000245 Get It

Testing for Herpes Simplex Virus in Low-Volume Cerebrospinal Fluid Samples: Comparison of Three Protocols To Optimize Detection
Espy, Mark J., Irish, Cole L., Binnicker, Matthew J.

Journal of Clinical Microbiology | September 24, 2015 | Volume: 53 | Issue: 12 | Pages: 3897-3899

10.1128/jcm.02386-15 Get It

ABSTRACT Detection of herpes simplex virus 1 and 2 (HSV-1 and HSV-2) in cerebrospinal fluid (CSF) is a medical emergency and requires rapid, sensitive testing. However, the volume of CSF received for microbiological studies may be limited, especially from young children. In this study, we compared three testing protocols to our routine real-time PCR method to determine the most sensitive approach for detecting HSV-1 and HSV-2 in low-volume (≤100 μl) CSF.
Multiplex Molecular Panels for Diagnosis of Gastrointestinal Infection: Performance, Result Interpretation, and Cost-Effectiveness
Binnicker, Matthew J.

Journal of Clinical Microbiology | August 27, 2015 | Volume: 53 | Issue: 12 | Pages: 3723-3728

10.1128/jcm.02103-15 Get It

ABSTRACT Gastrointestinal disease is a major cause of morbidity and mortality worldwide, especially among young children and immunocompromised patients. Diarrhea may result from infection with a variety of microbial pathogens, including bacteria, viruses, or parasites. Historically, the diagnosis of infectious diarrhea has been made using microscopy, antigen tests, culture, and real-time PCR. A combination of these traditional tests is often required due to the inability to distinguish between infectious etiologies based on the clinical presentation alone. Recently, several multiplex molecular assays have been developed for the detection of gastrointestinal pathogens directly from clinical stool samples. These panels allow for the detection and identification of up to 20 pathogens in as little as 1 h. This review will focus on the multiplex molecular panels that have received clearance from the FDA for the diagnosis of diarrheal disease and will highlight issues related to test performance, result interpretation, and cost-effectiveness of these new molecular diagnostic tools.
Direct Detection of Influenza A and B Viruses in Less Than 20 Minutes Using a Commercially Available Rapid PCR Assay
Binnicker, Matthew J. , Espy, Mark J., Irish, Cole L., Vetter, Emily A.

Journal of Clinical Microbiology | April 30, 2015 | Volume: 53 | Issue: 7 | Pages: 2353-2354

10.1128/jcm.00791-15 Get It

ABSTRACT We compared an FDA-cleared rapid (<20 min) PCR assay (Cobas Liat; Roche Diagnostics) to our routine influenza A and B real-time PCR assay (Simplexa Flu A/B & RSV Direct; Focus Diagnostics) using respiratory swabs ( n = 197). The Cobas Liat influenza A and B assays demonstrated sensitivities of 99.2% (123/124) and 100% (23/23), respectively, while showing a specificity of 100% for each target.
Simultaneous Detection of Herpes Simplex Virus 1 and 2 in the Cerebrospinal Fluid of a Patient with Seizures and Encephalitis
Anderson, Neil W. , Sistrunk, William, Binnicker, Matthew J. , Sistrunk, William W.

Journal of Clinical Microbiology | October 30, 2014 | Volume: 53 | Issue: 1 | Pages: 343-345

10.1128/jcm.02718-14 Get It

ABSTRACT We report a case of a 62-year-old female with seizures and encephalitis. Molecular testing of the patient's cerebrospinal fluid was positive for both herpes simplex virus 1 and 2 (HSV-1 and HSV-2). To our knowledge, this is the first report of simultaneous detection of HSV-1 and HSV-2 in cerebrospinal fluid.