Back to Authors

Yao, Joseph D C

Mayo Clinic

Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, USA jdcyao@mayo.edu.

Citations 2

Cytomegalovirus (CMV) DNA quantification in bronchoalveolar lavage fluid of immunocompromised patients with CMV pneumonia
Beam, Elena , Germer, Jeffrey J., Lahr, Brian D. , Yao, Joseph D. , Binnicker, Matthew J. , Lahr, Brian, Yao, Joseph D C, Limper, Andrew Harold, Beam, Elena , Limper, Andrew H. , Razonable, Raymund R.

Clinical Transplantation | November 7, 2017 | Volume: 32 | Issue: 1 | Pages: No page available

10.1111/ctr.13149 Get It

AbstractCytomegalovirus (CMV) pneumonia causes major morbidity and mortality. Its diagnosis requires demonstration of viral cytopathic changes in tissue, entailing risks of lung biopsy. This study aimed to determine CMV viral load (VL) thresholds in bronchoalveolar lavage fluid (BALF) for diagnosis of CMV pneumonia in immunocompromised patients. CMV VL in BALF was studied in 17 patients (83% transplant recipients) and 21 control subjects with and without CMV pneumonia, respectively, using an FDA‐approved PCR assay (Cobas® AmpliPrep/Cobas TaqMan® CMV Test, Roche Molecular Systems, Inc.) calibrated to the WHO International Standard for CMV DNA (NIBSC: 09/162). Receiver operating characteristic curve analysis produced a BALF CMV VL threshold of 34 800, IU/mL with 91.7% sensitivity and 100.0% specificity for diagnosis of possible, probable, and proven CMV pneumonia in transplant patients, while a threshold of 656 000 IU/mL yielded 100% sensitivity and specificity among biopsy‐proven cases. For all immunocompromised patients, a VL threshold of 274 IU/mL was selected. VL thresholds also were normalized to BALF cell count yielding a threshold of 0.32 IU/106 cells with 91.7% sensitivity and 90.5% specificity for possible, probable, and proven CMV pneumonia in transplant recipients. Monitoring CMV VL in BALF may be a less invasive method for diagnosing CMV pneumonia in immunocompromised patients.
Adoption of Lean Principles in a High-Volume Molecular Diagnostic Microbiology Laboratory
Mitchell, P. Shawn, Mandrekar, Jayawant N. , Yao, Joseph D. , Yao, Joseph D C

Journal of Clinical Microbiology | May 15, 2014 | Volume: 52 | Issue: 7 | Pages: 2689-2693

10.1128/jcm.00430-14 Get It

ABSTRACT Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved.