ABSTRACT Pneumonia may be caused by a diverse group of microorganisms; however, a microbiologic diagnosis is not universally made. Molecular tests such as the BIOFIRE FILMARRAY Pneumonia Panel (BF-PP) offer the possibility of rapid identification of potential pneumonia pathogens. This retrospective analysis was conducted as a sub-study of a recently published randomized controlled trial. Specimens from patients with suspected pneumonia were tested by the BF-PP, with results compared to cultures. The overall BF-PP positivity rate was 44.8% (252/563), and was higher [64.6% (164/254)] in specimens from patients ultimately diagnosed with pneumonia. Discrepancies between the BF-PP and cultures were most common for Streptococcus pneumoniae , Haemophilus influenzae , Moraxella catarrhalis, and Streptococcus agalactiae . Positive percent agreement (PPA) and negative percent agreement (NPA) between the BF-PP and culture were 91.4% (CI 86.3%–94.9%) and 83.6% (CI 79.5%–87.2%), respectively. For most bacteria, a correlation between high genomic abundance (genomic copies/mL) reported from the BF-PP and culture growth abundance was found. In specimens from patients ultimately diagnosed with pneumonia, clinical consistency—assessed based on whether BF-PP results aligned with associated culture results—was 79.9% and was highest for bronchoalveolar lavage fluid specimens. The BF-PP has reliable analytical performance and offers the potential advantage over conventional cultures of providing higher detection rates and more rapid results. Interestingly, despite the use of this advanced molecular diagnostic tool, one-third of pneumonia cases remained without a microbiologic etiology. IMPORTANCE This study evaluates the BIOFIRE FILMARRAY Pneumonia Panel by comparing its performance to conventional cultures in a real-world patient population (including patients ultimately diagnosed as not having pneumonia) using different types of specimens. Findings show a higher detection rate of microorganisms with the panel compared to cultures, suggesting that this test could aid in tailoring treatments for pneumonia. However, challenges remain and require further study, including distinguishing true pathogens from colonizing microorganisms and determinig why one-third of patients diagnosed with pneumonia still lacked a microbiologic etiology.
Comparison of the BioFire Joint Infection Panel to 16S Ribosomal RNA Gene-Based Targeted Metagenomic Sequencing for Testing Synovial Fluid from Patients with Knee Arthroplasty Failure
The diagnosis of periprosthetic joint infection (PJI) is challenging, often requiring multiple clinical specimens and diagnostic techniques, some with prolonged result turnaround times. Here, the diagnostic performance of the Investigational Use Only (IUO) BioFire Joint Infection (JI) Panel was compared to 16S rRNA gene-based targeted metagenomic sequencing (tMGS) applied to synovial fluid for PJI diagnosis.
Evaluation of a Commercial Multiplex Molecular Panel for Diagnosis of Infectious Meningitis and Encephalitis
ABSTRACT Rapid and accurate laboratory tests are important for the timely diagnosis and treatment of central nervous system infections. The FilmArray meningitis/encephalitis (ME) panel (BioFire Diagnostics, Salt Lake City, UT) is an FDA-cleared, multiplex molecular panel that allows the detection of 14 pathogens (bacterial [ n = 6], viral [ n = 7], and fungal [ n = 1] pathogens) from cerebrospinal fluid (CSF). In this study, we evaluated the performance characteristics of the FilmArray ME panel using clinical, residual CSF samples ( n = 291) that tested positive by a routine method(s) (e.g., bacterial culture, individual real-time PCR assay) for a pathogen represented on the ME panel. Of note, a subset ( n = 76) of the CSF specimens was collected during the prevaccine era and had been characterized as positive for a bacterial pathogen. The FilmArray ME panel demonstrated an overall percent positive agreement (PPA) of 97.5% (78/80) for bacterial pathogens, 90.1% (145/161) for viruses, and 52% (26/50) for Cryptococcus neoformans/C. gattii . Despite the low overall agreement (52%) between the ME panel and antigen testing for detection of C. neoformans/C. gattii , the percent positive agreement of the FilmArray assay for C. neoformans/C. gattii was 92.3% (12/13) when the results were compared directly to the results of routine fungal smear or culture. The FilmArray ME panel offers a rapid (∼60-min), syndrome-based approach for the detection of select meningitis and encephalitis pathogens.