ABSTRACT Pneumonia may be caused by a diverse group of microorganisms; however, a microbiologic diagnosis is not universally made. Molecular tests such as the BIOFIRE FILMARRAY Pneumonia Panel (BF-PP) offer the possibility of rapid identification of potential pneumonia pathogens. This retrospective analysis was conducted as a sub-study of a recently published randomized controlled trial. Specimens from patients with suspected pneumonia were tested by the BF-PP, with results compared to cultures. The overall BF-PP positivity rate was 44.8% (252/563), and was higher [64.6% (164/254)] in specimens from patients ultimately diagnosed with pneumonia. Discrepancies between the BF-PP and cultures were most common for Streptococcus pneumoniae , Haemophilus influenzae , Moraxella catarrhalis, and Streptococcus agalactiae . Positive percent agreement (PPA) and negative percent agreement (NPA) between the BF-PP and culture were 91.4% (CI 86.3%–94.9%) and 83.6% (CI 79.5%–87.2%), respectively. For most bacteria, a correlation between high genomic abundance (genomic copies/mL) reported from the BF-PP and culture growth abundance was found. In specimens from patients ultimately diagnosed with pneumonia, clinical consistency—assessed based on whether BF-PP results aligned with associated culture results—was 79.9% and was highest for bronchoalveolar lavage fluid specimens. The BF-PP has reliable analytical performance and offers the potential advantage over conventional cultures of providing higher detection rates and more rapid results. Interestingly, despite the use of this advanced molecular diagnostic tool, one-third of pneumonia cases remained without a microbiologic etiology. IMPORTANCE This study evaluates the BIOFIRE FILMARRAY Pneumonia Panel by comparing its performance to conventional cultures in a real-world patient population (including patients ultimately diagnosed as not having pneumonia) using different types of specimens. Findings show a higher detection rate of microorganisms with the panel compared to cultures, suggesting that this test could aid in tailoring treatments for pneumonia. However, challenges remain and require further study, including distinguishing true pathogens from colonizing microorganisms and determinig why one-third of patients diagnosed with pneumonia still lacked a microbiologic etiology.
Bloodstream Infection Due to Coagulase-Negative Staphylococci: Impact of Species on Prevalence of Infective Endocarditis
(1) Background: Coagulase-negative staphylococci (CoNS) are an important group of organisms that can cause bloodstream infection (BSI) and infective endocarditis (IE). The prevalence of IE in patients with BSI due to different CoNS species, however, has received limited attention; (2) Methods: A retrospective study of adults with monomicrobial CoNS BSI who had undergone echocardiography and a risk factor analysis was done to determine the most common CoNS species that cause definite IE; (3) Results: 247 patients with CoNS BSI were included in the investigation; 49 (19.8%) had definite IE, 124 (50.2%) possible IE, and 74 (30.0%) BSI only. The latter two entities were grouped in one category for further analysis. The most common species in CoNS BSI was Staphylococcus epidermidis (79.4%) and most patients (83.2%) had possible IE/BSI only. 59.1% of patients with BSI due to S. lugdunensis had definite IE. The majority of CoNS were healthcare-associated/nosocomial bacteremia. Multivariable analysis demonstrated that valve disease (p = 0.002) and a foreign cardiovascular material (p < 0.001) were risk factors associated with definite IE. Patients with S. lugdunensis BSI had an 8-fold higher risk of definite IE than did those with S. epidermidis BSI and nearly a 13-fold higher risk than did patients with BSI due to other species of CoNS (p = 0.002); (4) Conclusions: The prevalence of definite IE in patients with BSI due to different CoNS species was significant. CoNS bacteremia, particularly with S. lugdunensis, confers a significant risk of IE, particularly in patients with a valve disease or intravascular foreign body material and should not be immediately dismissed as a contaminant.