The antibiofilm activity of a hypochlorous acid (HOCl)-producing electrochemical bandage (e-bandage) was assessed against 14 yeast isolates in vitro . The evaluated e-bandage was polarized at +1.5 V Ag/AgCl to allow continuous production of HOCl.
Antibiofilm Activity of a Tunable Hypochlorous Acid‐Generating Electrochemical Bandage Controlled by a Wearable Potentiostat
Chronic wound biofilm infections represent a major clinical challenge which results in a substantial burden to patients and healthcare systems. Treatment with topical antibiotics is oftentimes ineffective as a result of antibiotic‐resistant microorganisms and biofilm‐specific antibiotic tolerance. Use of biocides such as hypochlorous acid (HOCl) has gained increasing attention due to the lack of known resistance mechanisms. An HOCl‐generating electrochemical bandage (e‐bandage) is designed that delivers HOCl continuously at low concentrations targeting infected wound beds in a similar manner to adhesive antimicrobial wound dressings. A battery‐operated wearable potentiostat is developed that controls the e‐bandage electrodes at potentials suitable for HOCl generation. It is demonstrated that e‐bandage treatment is tunable by changing the applied potential. HOCl generation on electrode surfaces is verified using microelectrodes. The developed e‐bandage shows time‐dependent responses against in vitro Acinetobacter baumannii and Staphylococcus aureus biofilms, reducing viable cells to nondetectable levels within 6 and 12 h of treatment, respectively. The developed e‐bandage should be further evaluated as an alternative to topical antibiotics to treat wound biofilm infections.
Activity of a hypochlorous acid‐producing electrochemical bandage as assessed with a porcine explant biofilm model
AbstractThe activity of a hypochlorous acid‐producing electrochemical bandage (e‐bandage) in preventing methicillin‐resistant Staphylococcus aureus infection (MRSA) infection and removing biofilms formed by MRSA was assessed using a porcine explant biofilm model. e‐Bandages inhibited S. aureus infection (p = 0.029) after 12 h (h) of exposure and reduced 3‐day biofilm viable cell counts after 6, 12, and 24 h exposures (p = 0.029). Needle‐type microelectrodes were used to assess HOCl concentrations in explant tissue as a result of e‐bandage treatment; toxicity associated with e‐bandage treatment was evaluated. HOCl concentrations in infected and uninfected explant tissue varied between 30 and 80 µM, decreasing with increasing distance from the e‐bandage. Eukaryotic cell viability was reduced by an average of 71% and 65% in fresh and day 3‐old explants, respectively, when compared to explants exposed to nonpolarized e‐bandages. HOCl e‐bandages are a promising technology that can be further developed as an antibiotic‐free treatment for wound biofilm infections.
Efficacy and toxicity of hydrogen peroxide producing electrochemical bandages in a porcine explant biofilm model
Abstract Aims Effects of H2O2 producing electrochemical-bandages (e-bandages) on methicillin-resistant Staphylococcus aureus colonization and biofilm removal were assessed using a porcine explant biofilm model. Transport of H2O2 produced from the e-bandage into explant tissue and associated potential toxicity were evaluated. Methods and Results Viable prokaryotic cells from infected explants were quantified after 48 h treatment with e-bandages in three ex vivo S. aureus infection models: (1) reducing colonization, (2) removing young biofilms and (3) removing mature biofilms. H2O2 concentration-depth profiles in explants/biofilms were measured using microelectrodes. Reductions in eukaryotic cell viability of polarized and nonpolarized noninfected explants were compared. e-Bandages effectively reduced S. aureus colonization (p = 0.029) and reduced the viable prokaryotic cell concentrations of young biofilms (p = 0.029) with limited effects on mature biofilms (p > 0.1). H2O2 penetrated biofilms and explants and reduced eukaryotic cell viability by 32–44% compared to nonpolarized explants. Conclusions H2O2 producing e-bandages were most active when used to reduce colonization and remove young biofilms rather than to remove mature biofilms. Significance and Impact of Study The described e-bandages reduced S. aureus colonization and young S. aureus biofilms in a porcine explant wound model, supporting their further development as an antibiotic-free alternative for managing biofilm infections.
773. Hypochlorous Acid Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infections
Abstract Background Central-line associated bloodstream infection (CLABSI) contributes to mortality and cost. While aseptic dressings and antibiotic-impregnated catheters can prevent extraluminal infections, intraluminal infections remain a source of CLABSIs with limited prevention options. Methods In this proof-of-concept study, an electrochemical intravascular catheter (e-catheter) prototype capable of electrochemically generating hypochlorous acid intraluminally on the surface of platinum electrodes polarized at a constant potential of 1.5 VAg/AgCl was developed. After 24h of pre-polarization at 1.5 VAg/AgCl, their activity was tested by inoculating four clinical isolates derived from catheter-related infections, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium and Escherichia coli. Figure 1. In vitro catheter and e-catheter models. Results E-catheters generated a mean HOCl concentration of 15.86±4.03 μM and had a mean pH of 6.14±0.79. e-catheters prevented infections with all four species, with an average reduction of 8.41±0.61 log10 CFU/mL at 48h compared to controls. Figure 3. Measurement of pH and HOCl at 48 hours in polarized e-catheters. Each dot represents a replicate; bars represent means. Figure 4. Prevention of infection after 48 hours of polarization (24 hours of infections) using e-catheters (polarized and non-polarized) compared to blank catheters. * indicates statistically significant reduction of cell counts in polarized e-catheter compared to blank catheter (p <0.05). Conclusion Polarized e-catheters which generate low amounts of HOCl continuously should be further developed to prevent intraluminal infection. Disclosures Haluk Beyenal, Ph.D, patent (Other Financial or Material Support, HB holds a patent: Beyenal H CD, Fransson BA, Sultana ST. . 2018. Electrochemical reduction or prevention of infections. U.S. patent 20180207301A1, international patent WO/2017/011635.) Robin Patel, MD, 1928 Diagnostics (Consultant)BioFire Diagnostics (Grant/Research Support)ContraFect Corporation (Grant/Research Support)Curetis (Consultant)Hylomorph AG (Grant/Research Support)IDSA (Other Financial or Material Support, Editor's Stipend)Infectious Diseases Board Review Course (Other Financial or Material Support, Honoraria)Mammoth Biosciences (Consultant)NBME (Other Financial or Material Support, Honoraria)Netflix (Consultant)Next Gen Diagnostics (Consultant)PathoQuest (Consultant)PhAST (Consultant)Qvella (Consultant)Samsung (Other Financial or Material Support, Patent Royalties)Selux Diagnostics (Consultant)Shionogi & Co., Ltd. (Grant/Research Support)Specific Technologies (Consultant)TenNor Therapeutics Limited (Grant/Research Support)Torus Biosystems (Consultant)Up-to-Date (Other Financial or Material Support, Honoraria) Robin Patel, MD, BioFire (Individual(s) Involved: Self): Grant/Research Support; Contrafect (Individual(s) Involved: Self): Grant/Research Support; IDSA (Individual(s) Involved: Self): Editor's stipend; NBME, Up-to-Date and the Infectious Diseases Board Review Course (Individual(s) Involved: Self): Honoraria; Netflix (Individual(s) Involved: Self): Consultant; TenNor Therapeutics Limited (Individual(s) Involved: Self): Grant/Research Support; to Curetis, Specific Technologies, Next Gen Diagnostics, PathoQuest, Selux Diagnostics, 1928 Diagnostics, PhAST, Torus Biosystems, Mammoth Biosciences and Qvella (Individual(s) Involved: Self): Consultant
Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
Catheter-related infections constitute an economic and mortality burden in health care. Several options are available to reduce the risk of infection, but only a few focus on preventing intraluminal infection, which occurs in long-term catheters, most often used for dialysis, prolonged treatment, or chemotherapy.
Hydrogen peroxide‐producing electrochemical bandage controlled by a wearable potentiostat for treatment of wound infections
AbstractChronic wound infections caused by biofilm‐forming microorganisms represent a major burden to healthcare systems. Treatment of chronic wound infections using conventional antibiotics is often ineffective due to the presence of bacteria with acquired antibiotic resistance and biofilm‐associated antibiotic tolerance. We previously developed an electrochemical scaffold that generates hydrogen peroxide (H2O2) at low concentrations in the vicinity of biofilms. The goal of this study was to transition our electrochemical scaffold into an H2O2‐generating electrochemical bandage (e‐bandage) that can be used in vivo. The developed e‐bandage uses a xanthan gum‐based hydrogel to maintain electrolytic conductivity between e‐bandage electrodes and biofilms. The e‐bandage is controlled using a lightweight, battery‐powered wearable potentiostat suitable for use in animal experiments. We show that e‐bandage treatment reduced colony‐forming units of Acinetobacter buamannii biofilms (treatment vs. control) in 12 h (7.32 ± 1.70 vs. 9.73 ± 0.09 log10[CFU/cm2]) and 24 h (4.10 ± 12.64 vs. 9.78 ± 0.08 log10[CFU/cm2]) treatments, with 48 h treatment reducing viable cells below the limit of detection of quantitative and broth cultures. The developed H2O2‐generating e‐bandage was effective against in vitro A. baumannii biofilms and should be further evaluated and developed as a potential alternative to topical antibiotic treatment of wound infections.
In Vitro
Antibacterial Activity of Hydrogen Peroxide and Hypochlorous Acid, Including That Generated by Electrochemical Scaffolds
Hydrogen peroxide (H 2 O 2 ) and hypochlorous acid (HOCl) are biocides used for cleaning and debriding chronic wound infections, which often harbor drug-resistant bacteria. Here, we evaluated the in vitro activity of H 2 O 2 and HOCl against 27 isolates of eight bacterial species involved in wound infections.
An Integrated HOCl-Producing E-Scaffold Is Active against Monomicrobial and Polymicrobial Biofilms
Oxidizing agents like hypochlorous acid (HOCl) have antimicrobial activity. We developed an integrated electrochemical scaffold, or e-scaffold, that delivers a continuous low dose of HOCl aimed at targeting microbial biofilms without exceeding concentrations toxic to humans as a prototype of a device being developed to treat wound infections in humans.
Abstract Aims Wound infections involving Candida albicans can be challenging to treat because of the fungus’ ability to penetrate wound tissue and form biofilms. The goal of this study was to assess the activity of a hypochlorous acid (HOCl)-generating electrochemical scaffold (e-scaffold) against C. albicans biofilms in vitro and on porcine dermal explants (ex vivo). Methods and Results C. albicans biofilms were grown either on acrylic-bottom six-well plates (in vitro) or on skin tissue excised from porcine ears (ex vivo), and the polarized e-scaffold was used to generate a continuous supply of low concentration HOCl near biofilm surfaces. C. albicans biofilms grown in vitro were reduced to undetectable amounts within 24 h of e-scaffold exposure, unlike control biofilms (5·28 ± 0·034 log10 (CFU cm-2); P < 0·0001). C. albicans biofilms grown on porcine dermal explants were also reduced to undetectable amounts in 24 h, unlike control explant biofilms (4·29 ± 0·057 log10 (CFU cm-2); P < 0·0001). There was a decrease in the number of viable mammalian cells (35·6 ± 6·4%) in uninfected porcine dermal explants exposed to continuous HOCl-generating e-scaffolds for 24 h compared to explants exposed to nonpolarized e-scaffolds (not generating HOCl) (P < 0·05). Conclusions Our HOCl-generating e-scaffold is a potential antifungal-free strategy to treat C. albicans biofilms in chronic wounds. Significance and Impact of the Study Wound infections caused by C. albicans are difficult to treat due to presence of biofilms in wound beds. Our HOCl producing e-scaffold provides a promising novel approach to treat wound infections caused by C. albicans.