Back to Authors

Manduca, Armando

https://orcid.org/0000-0002-9411-5671

Mayo Clinic

Mayo Clinic

Citations 70

Quantitative 3D magnetic resonance elastography: Comparison with dynamic mechanical analysis
Arunachalam, Shivaram P. , Rossman, Phillip J. , Arani, Arvin , Lake, David S. , Glaser, Kevin J. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin

Magnetic Resonance in Medicine | March 26, 2016 | Volume: 77 | Issue: 3 | Pages: 1184-1192

10.1002/mrm.26207 Get It

Purpose Magnetic resonance elastography (MRE) is a rapidly growing noninvasive imaging technique for measuring tissue mechanical properties in vivo. Previous studies have compared two‐dimensional MRE measurements with material properties from dynamic mechanical analysis (DMA) devices that were limited in frequency range. Advanced DMA technology now allows broad frequency range testing, and three‐dimensional (3D) MRE is increasingly common. The purpose of this study was to compare 3D MRE stiffness measurements with those of DMA over a wide range of frequencies and shear stiffnesses. Methods 3D MRE and DMA were performed on eight different polyvinyl chloride samples over 20–205 Hz with stiffness between 3 and 23 kPa. Driving frequencies were chosen to create 1.1, 2.2, 3.3, 4.4, 5.5, and 6.6 effective wavelengths across the diameter of the cylindrical phantoms. Wave images were analyzed using direct inversion and local frequency estimation algorithm with the curl operator and compared with DMA measurements at each corresponding frequency. Samples with sufficient spatial resolution and with an octahedral shear strain signal‐to‐noise ratio > 3 were compared. Results Consistency between the two techniques was measured with the intraclass correlation coefficient (ICC) and was excellent with an overall ICC of 0.99. Conclusions 3D MRE and DMA showed excellent consistency over a wide range of frequencies and stiffnesses. Magn Reson Med 77:1184–1192, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
Magnetic resonance elastography of frontotemporal dementia
Murphy, Matthew C. , Fattahi, Nikoo , Glaser, Kevin J. , Huston, John , Boeve, Bradley F. , Arani, Arvin , Manduca, Armando , Jones, David T. , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | January 19, 2016 | Volume: 43 | Issue: 2 | Pages: No page available

10.1002/jmri.25155 Get It

PurposeTo investigate the feasibility of utilizing brain stiffness as a potential biomarker for behavioral variant frontotemporal dementia (bvFTD) patients. Magnetic resonance elastography (MRE) is a noninvasive technique for evaluating the mechanical properties of brain tissue in vivo. MRE has demonstrated decreased brain stiffness in patients with Alzheimer's disease.Materials and MethodsWe examined five male subjects with bvFTD and nine cognitively normal age‐matched male controls (NC) with brain 3T MRE. Stiffness was calculated in nine regions of interest (ROIs): whole brain (entire cerebrum excluding cerebellum), frontal lobes, occipital lobes, parietal lobes, temporal lobes, deep gray matter / white matter (GM/WM; insula, deep gray nuclei and white matter tracts), cerebellum, sensorimotor cortex (pre‐ and postcentral gyri), and a composite region labeled FT (frontal and temporal lobes excluding the pre‐ and postcentral gyri).ResultsSignificantly lower stiffness values were observed in the whole brain (P = 0.007), frontal lobe (P = 0.001), and temporal lobes (P = 0.005) of bvFTD patients compared to NC. No significant stiffness differences were observed in any other ROIs of bvFTD patients compared to NC (P > 0.05). These results demonstrate that statistically significant brain softening occurs in the frontal and temporal lobes of bvFTD patients, which corresponds to the expected pathophysiology of bvFTD.ConclusionFuture studies evaluating the feasibility of brain MRE for early disease detection and monitoring disease progression could shed new insights into understanding the mechanisms involved in bvFTD. J. Magn. Reson. Imaging 2016;43:474–478.
In vivo, high‐frequency three‐dimensional cardiac MR elastography: Feasibility in normal volunteers
Arani, Arvin , Glaser, Kevin, Arunachalam, Shivaram P. , Rossman, Phillip J. , Lake, David S. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Glaser, Kevin L, Glaser, Kevin J. , Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin

Magnetic Resonance in Medicine | January 17, 2016 | Volume: 77 | Issue: 1 | Pages: 351-360

10.1002/mrm.26101 Get It

Purpose Noninvasive stiffness imaging techniques (elastography) can image myocardial tissue biomechanics in vivo. For cardiac MR elastography (MRE) techniques, the optimal vibration frequency for in vivo experiments is unknown. Furthermore, the accuracy of cardiac MRE has never been evaluated in a geometrically accurate phantom. Therefore, the purpose of this study was to determine the necessary driving frequency to obtain accurate three‐dimensional (3D) cardiac MRE stiffness estimates in a geometrically accurate diastolic cardiac phantom and to determine the optimal vibration frequency that can be introduced in healthy volunteers. Methods The 3D cardiac MRE was performed on eight healthy volunteers using 80 Hz, 100 Hz, 140 Hz, 180 Hz, and 220 Hz vibration frequencies. These frequencies were tested in a geometrically accurate diastolic heart phantom and compared with dynamic mechanical analysis (DMA). Results The 3D Cardiac MRE was shown to be feasible in volunteers at frequencies as high as 180 Hz. MRE and DMA agreed within 5% at frequencies greater than 180 Hz in the cardiac phantom. However, octahedral shear strain signal to noise ratios and myocardial coverage was shown to be highest at a frequency of 140 Hz across all subjects. Conclusion This study motivates future evaluation of high‐frequency 3D MRE in patient populations. Magn Reson Med 77:351–360, 2017. © 2016 Wiley Periodicals, Inc.
Automated liver elasticity calculation for MR elastography
Dzyubak, Bogdan , Venkatesh, Sudhakar K. , Glaser, Kevin J. , Manduca, Armando , Ehman, Richard L. , Dzyubak, Bogdan , Venkatesh, Sudhakar K

Journal of Magnetic Resonance Imaging | October 23, 2015 | Volume: 43 | Issue: 5 | Pages: 1055-1063

10.1002/jmri.25072 Get It

PurposeMR elastography (MRE) is a phase‐contrast MRI technique that is used to quantitatively assess liver stiffness for staging hepatic fibrosis. The current approach requires manual selection of a region of interest (ROI) with good wave quality from which to measure stiffness. The purpose of this work was to develop and evaluate a fully automated approach for measuring hepatic stiffness from MRE images to further reduce measurement variability.Materials and MethodsAn automated liver elasticity calculation (ALEC) algorithm was developed to address reader stiffness measurement variability. ALEC has three stages: initial tissue estimation, segmentation, and ROI cleanup. Stiffnesses measured by the algorithm were compared with technicians and an expert radiologist in a set of 121 clinical cases acquired at 1.5 Tesla. Intra‐class correlation (ICC), Bland‐Altman analysis, and a noninferiority test were performed to evaluate whether the algorithm can be used in place of manual analysis by technicians.ResultsThe stiffness measurement difference with the expert was 1.42% ± 11.17% (mean ± standard deviation) for the algorithm and 1.82% ± 13.65% for the technicians. The ICCs were 0.981 and 0.984, respectively. Both the algorithm and technicians were equivalent to the expert within a 5% significance margin (P < 0.01). The algorithm had no failures in the 119 cases that were considered analyzable by the human readers.ConclusionThe results of this study show that the newly developed automated algorithm is able to measure stiffness in clinical liver MRE exams with an accuracy that is equivalent to that of an expert radiologist. ALEC may be useful for analysis of archived data and suitable for performing multi‐center studies. J. Magn. Reson. Imaging 2016;43:1055–1063.
Magnetic resonance elastography of frontotemporal dementia
Huston, John , Murphy, Matthew C. , Fattahi, Nikoo , Arani, Arvin , Glaser, Kevin J. , Boeve, Bradley F. , Manduca, Armando , Jones, David T. , Ehman, Richard L. , Arani, Arvin

Journal of Magnetic Resonance Imaging | June 30, 2015 | Volume: 43 | Issue: 2 | Pages: 474-478

10.1002/jmri.24977 Get It

PurposeTo investigate the feasibility of utilizing brain stiffness as a potential biomarker for behavioral variant frontotemporal dementia (bvFTD) patients. Magnetic resonance elastography (MRE) is a noninvasive technique for evaluating the mechanical properties of brain tissue in vivo. MRE has demonstrated decreased brain stiffness in patients with Alzheimer's disease.Materials and MethodsWe examined five male subjects with bvFTD and nine cognitively normal age‐matched male controls (NC) with brain 3T MRE. Stiffness was calculated in nine regions of interest (ROIs): whole brain (entire cerebrum excluding cerebellum), frontal lobes, occipital lobes, parietal lobes, temporal lobes, deep gray matter / white matter (GM/WM; insula, deep gray nuclei and white matter tracts), cerebellum, sensorimotor cortex (pre‐ and postcentral gyri), and a composite region labeled FT (frontal and temporal lobes excluding the pre‐ and postcentral gyri).ResultsSignificantly lower stiffness values were observed in the whole brain (P = 0.007), frontal lobe (P = 0.001), and temporal lobes (P = 0.005) of bvFTD patients compared to NC. No significant stiffness differences were observed in any other ROIs of bvFTD patients compared to NC (P > 0.05). These results demonstrate that statistically significant brain softening occurs in the frontal and temporal lobes of bvFTD patients, which corresponds to the expected pathophysiology of bvFTD.ConclusionFuture studies evaluating the feasibility of brain MRE for early disease detection and monitoring disease progression could shed new insights into understanding the mechanisms involved in bvFTD. J. Magn. Reson. Imaging 2016;43:474–478.
P4‐332: Regional brain stiffness changes across the Alzheimer's disease spectrum
Murphy, Matthew C. , Glaser, Kevin J. , Felmlee, Joel P. , Huston, John , Jack, Clifford R. , Jones, David T. , Senjem, Matthew L. , Manduca, Armando , Ehman, Richard L.

Alzheimer's & Dementia | March 29, 2014 | Volume: 8 | Issue: 4S_Part_21 | Pages: No page available

10.1016/j.jalz.2013.08.113 Get It

Magnetic resonance elastography
Ehman, Richard L. , Manduca, Armando

The Journal of the Acoustical Society of America | October 23, 2013 | Volume: 117 | Issue: 4_Supplement | Pages: 2587-2587

10.1121/1.4777170 Get It

The goal of our research is to develop MRI-based methods for assessing the mechanical properties of tissues in vivo. We have focused on a novel MRI technique for visualizing propagating acoustic shear waves [Science 269, 1854–1857 (1995)]. Suitable dynamic shear stress for Magnetic Resonance Elastography (MRE) can be generated by surface drivers, inertial effects, acoustic radiation pressure, or endogenous physiologic mechanisms. The MRE acquisition sequence is capable of visualizing cyclic tissue motion of less than 1 micron in displacement amplitude, with imaging times ranging from 100 ms to several minutes. Inversion algorithms based on continuum mechanics are used to process the acquired data to generate maps of mechanical properties such as depict stiffness, viscosity, attenuation, and anisotropic behavior. We have applied MRE to assess specimens of a variety of tissues, ranging in stiffness from lung to cartilage. Human studies have demonstrated that it is feasible to apply MRE to quantitatively image the mechanical properties of skeletal muscles, gray and white matter in the brain, thyroid, kidney, liver, and skin. Our preliminary clinical studies have to date applied MRE to observe changes in tissue mechanical properties in patients with breast, brain, and thyroid tumors, liver fibrosis, and diffuse diseases of skeletal muscle.
Noncathartic CT Colonography: Image Quality Assessment and Performance and in a Screening Cohort
Silva, Alvin C. , Fidler, Jeff L. , Cernigliaro, Joseph G. , Wilson, Lynn A., Engelby, Trudy A., Spencer, Garrett, Harmsen, William S. , Mandrekar, Jay , Johnson, C. Daniel, Fletcher, Joel G. , Fidler, Jeff L. , Manduca, Armando , Limburg, Paul J.

American Journal of Roentgenology | September 24, 2013 | Volume: 201 | Issue: 4 | Pages: 787-794

10.2214/ajr.12.9225 Get It

MR Elastography of Breast Cancer: Preliminary Results
McKnight, Alexia L., Kugel, Jennifer L., Rossman, Phillip J. , Hartmann, Lynn C. , Manduca, Armando , Ehman, Richard L.

American Journal of Roentgenology | February 28, 2013 | Volume: 178 | Issue: 6 | Pages: 1411-1417

10.2214/ajr.178.6.1781411 Get It