Background and importance Neurointervention is a very competitive specialty in the United States due to the limited number of training spots and the larger pool of applicants. The training standards are continuously updated to ensure solid training experiences. Factors affecting candidate(s) selection have not been fully established yet. Our study aims to investigate the factors influencing the selection process. Methods A 52-question survey was distributed to 93 program directors (PDs). The survey consisted of six categories: (a) Program characteristics, (b) Candidate demographics, (c) Educational credentials, (d) Personal traits, (e) Research and extracurricular activities, and (f) Overall final set of characteristics. The response rate was 59.1%. As per the programs’ characteristics, neurosurgery was the most involved specialty in running the training programs (69%). Regarding demographics, the need for visa sponsorship held the greatest prominence with a mean score of 5.9 [standard deviation (SD) 2.9]. For the educational credentials, being a graduate from a neurosurgical residency and the institution where the candidate's residency training is/was scored the highest [5.4 (SD = 2.9), 5.4 (SD = 2.5), respectively]. Regarding the personal traits, assessment by faculty members achieved the highest score [8.9 (SD = 1)]. In terms of research/extracurricular activities, fluency in English had the highest score [7.2 (SD = 1.9)] followed by peer-reviewed/PubMed-indexed publications [6.4 (SD = 2.2)]. Conclusion Our survey investigated the factors influencing the final decision when choosing the future neurointerventional trainee, including demographic, educational, research, and extracurricular activities, which might serve as valuable guidance for both applicants and programs to refine the selection process.
Safety and Efficacy of Flow Diverters for Treatment of Unruptured Anterior Communicating Artery Aneurysms: Retrospective Multicenter Study
Background The anterior communicating artery (AComm) region is the most common site of intracranial aneurysms, with increased rupture risk compared with other locations. Overall, flow diverters present as a safe and efficacious treatment for intracranial aneurysms, but there is paucity of data for their use in the treatment of unruptured AComm aneurysms. We present the largest multicentric analysis evaluating the outcomes of flow diverters in AComm aneurysm treatment. Methods Databases from 10 centers were retrospectively reviewed for unruptured AComm aneurysms treated with flow diverters. Demographics, clinical presentation, radiographic characteristics, procedural complications, and outcomes were assessed. Results A total of 144 patients harboring 147 AComm aneurysms were treated between January 2012 and December 2021. Seventy-four were women (51.4%) and median age was 60 (IQR 50–67) years. All were unruptured AComm aneurysms. Half of the cohort had similar anterior cerebral artery sizes (51.4%). The most common morphology was saccular (94.6%), with a branch involvement in 32.7% of cases. Median vessel diameter was 2.4 mm, and the Pipeline Flex was the most prevalent device (32.7%). Median follow-up time was 17 months, with complete occlusion in 86.4% at the last follow-up. Functional independence (modified Rankin Scale score 0–2) was reported in 95.1%. Intraprocedural complications occurred in 5.6%, and postoperative complications were noted in 9.7% of cases. Combined major complication and mortality rate was 2.1%. Conclusions Our study suggests that flow diverters are a useful treatment for AComm aneurysms. Mid-term results indicated favorable aneurysm occlusion with a good safety profile. Additional prospective studies with longer follow-up periods and independent adjudication are warranted to better assess these results.
Abstract Number ‐ 7: Final Angiographic, Clinical and Thrombus Composition Results of 1000 Patients in the EXCELLENT Registry
Introduction EXCELLENT (NCT03685578; Cerenovus) is a large, prospective, international, real‐world registry of endovascular clot removal in acute ischemic stroke (AIS) with EmboTrap as the first line mechanical thrombectomy (MT) device, which included collection and analysis of the retrieved thrombus material. Methods Between September 2018 and March 2021, 1000 “all‐comer” patients were enrolled at 34 global sites (27 US, 5 EU, 1 UK, 1 Israel) and treated according to standard of care at each center (with Embrotrap as first line). The study employed blind endpoint evaluation, including a core imaging lab and an independent 90‐day mRS assessment. Retrieved clot was collected per each MT maneuver from 538 subjects across 26 sites and clot analysis was performed by independent central labs blinded to clinical data. Results mITT population included 998 subjects. Mean age was 69.9±14.18 years (range 18–102), 51.8% (517/998) subjects were female and 9.9% (97/997) had a pre‐stroke mRS 3–5. Baseline NIHSS was 15.6±6.87 (range 0–36); 10.1% (82/815) subjects had a large core (ASPECTS 0–5); 5.8% (57/990) had posterior stroke; 56.3% (523/929) underwent MT ≤ 6hrs of onset and 38.1% (380/998) received IV‐tPA prior to MT. First pass eTICI 2c‐3 was achieved in 38.3% (377/984) and final 2b‐3 in 94.5 % (930/984; median number of passes = 1) of subjects. 90‐day mRS≤2 or ≤pre‐stroke was 46.9% (429/915) and 90‐day all‐cause mortality was 19.0% (175/921). The univariate analysis of clot components showed high red blood cell and low platelet content were significant predictors of good mRS outcome (p < 0.001 and 0.009) and negative predictors of 90‐day mortality (p < 0.001 and 0.017, respectively). Conclusions This large multi‐center, all‐comer cohort reflects the population undergoing thrombectomy today in a real world‐setting. Final angiographic, clinical and thrombus composition results, along with multivariate analysis of predictors of clinical outcomes, will be presented at the time of the conference.
Abstract WMP87: Primary Results From The CLEAR Study Of The Safety And Effectiveness Of The Neva Stent Retriever For Large Vessel Thrombectomy
Despite the proven benefit of stent retrievers, challenges to rapid revascularization of large vessel occlusions (LVO) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed with openings in the basket cell structure (“drop zones”) intended to capture organized thrombi within the central scaffold during retrieval. Prospective, multicenter, open label, single arm, FDA-regulated IDE study to evaluate the performance of the NeVa device for recanalizing occluded intracranial vessels including ICA, M1/M2 MCA, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of eTICI 2b-3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a margin of -10%. Additional efficacy endpoints included first pass effect to eTICI 2b-3 (FPE) and 90-day mRS 0-2. Primary safety endpoint was 90-day mortality. (ClinicalTrials.gov NCT04514562) (Site-adjudicated revascularization results are reported here. Final core lab results will be presented at the conference.) From April 1, 2021 to April 28, 2022, 139 subjects were enrolled at 25 centers in the US and Europe. Mean age was 67 ± 13 years; 47% were female. Median NIHSS score was 16 (IQR: 12-20). Occlusions were 14 (10%) ICA, 85 (61%) M1, 38 (27%) M2, 1 (1%) Basilar and 1 (1%) PCA. Mean time to first pass was 19 ± 12 minutes. eTICI 2b-3 within 3 NeVa passes occurred in 87.8% (122/139; CI 81.1%,92.7%; non-inferiority p<0.0001; post hoc superiority p=0.002, tested against performance goal of 72%). FPE (to eTICI 2b-3) was observed in 67.6% (94/139), with first pass to eTICI 2b67-3 in 61.2% (85/139) and to eTICI 2c-3 in 43.9% (61/139). Median number of passes was 1 (IQR 1-2). Final eTICI 2b-3 rate was 94.2% (131/139); final eTICI 2c-3 rate was 65.5% (91/139). Good outcome (90-day mRS 0-2) was seen in 62.6% (87/139) and was 74.4% in patients with FPE (70/94 vs. 17/45 (37.8%) without FPE; p<0.0001). Mortality was 9.4% (13/139) with sICH in 8 (5.8%) subjects. The NeVa device is effective and safe for revascularization of LVO strokes and demonstrates high first pass success in this international multicenter study. First pass reperfusion (eTICI 2b-3) was strongly associated with functional independence.
Abstract 99: Clot Composition And Reperfusion Outcomes In 1430 Mechanical Thrombectomy Patients: Analysis Of The Stroke Thromboembolism Registry Of Imaging And Pathology
Background: Understanding clot composition may allow for better technical planning and improved outcomes in mechanical thrombectomy (MT). We sought to correlate clot composition with reperfusion outcomes in MT. Methods: Clinical, imaging, and clot data from patients enrolled in the STRIP Registry from September 2016 to September 2020 were analyzed. Samples were fixed in 10% phosphate-buffered formalin and stained with hematoxylin and eosin and Martius Scarlett Blue. Percent composition, richness, and gross appearance were evaluated. Outcome measures included the rate of First-Pass Effect (mTICI2c/3, FPE) and the number of device passes. Results: A total of 1430 patients (mean age, 68.4±13.5years; median [IQR] baseline NIHSS,17.2 [10.5-23]; IV-tPA use, 36%; Stent-Retrievers [SR], 27%; Contact Aspiration [CA], 27%; Combined SR + CA, 43%) were included. The median [IQR] number of passes was 1 [1-2]. FPE was achieved in 39.3% of the cases. There was no association between percent histological composition or clot richness and FPE in the overall population. However, the combined technique resulted in lower FPE rates for RBC-rich (P<0.0001), platelet-rich (P=0.003), and mixed (P<0.0001) clots. Fibrin-rich and platelet-rich clots required a higher number of passes compared to RBC-rich and mixed clots (median, 2 and 1.5 vs.1, respectively, P=0.02). CA displayed a trend towards a higher number of passes with fibrin-rich clots (2 vs.1, P=0.12). By gross appearance, mixed/heterogeneous clots had lower FPE rates than red and white clots. Conclusion: Despite the lack of correlation between clot histology and FPE in the overall population, our study adds to the growing body of evidence supporting the notion that clot composition influences reperfusion treatment strategy outcomes. Additional studies are needed.
Abstract 28: First Pass Outcomes And Associated Clot Characteristics: Secondary Analysis Of The Excellent Registry
Introduction: EXCELLENT (NCT03685578) is a global prospective, multicenter, real-world registry of mechanical thrombectomy for stroke with the EmboTrap device as first line treatment which includes clot collection and analysis. Aim of the study: To report the rates of clinical outcomes and clot characteristics associated with first pass reperfusion in EXCELLENT. Methods: Per pass angiographic outcomes assessed by an independent core lab were available in 984 subjects Analysis of clot from 538 cases was performed by independent central labs blinded to clinical data. 90-day mRS assessment was blinded to subject data. Results: First pass reperfusion of mTICI 2b-3 (63.2%) and 2c-3 (38.3%) was significantly predictive of mRS 0-2 or ≤pre-stroke (p=0.011 and p=0.016) but not all-cause mortality at 90 days (p=0.080 and p=0.123, respectively). Further, mTICI 2c-3 in one pass was associated with a higher rate of mRS 0-2 or ≤pre-stroke vs. mTICI 2c-3 reperfusion in >1 pass, (55.5% and 45.1%, respectively, p=0.013) and a rate of all-cause mortality at 90 days of 14.6% vs. 19.8% (p=0.097). Full patient characteristics and clinical outcomes are shown in Table 1. Notable clot composition findings included: RBC (%, mean±SD): mTICI 2c-3, 1 pass 47.69±22.25, mTICI 2c-3, >1 pass 43.86±19.05, (p=0.088); fibrin: mTICI 2c-3, 1 pass 23.20±13.80, mTICI 2c-3 >1 pass 25.40 ± 13.52 (p=0.131); von Willebrand factor (VWF): mTICI2c-3, 1 pass 16.09±14.62, mTICI 2c-3, >1 pass 19.42±17.15 (p=0.038). Conclusions: First pass reperfusion in the EXCELLENT registry was associated with better clinical outcomes at 90 days. Clots retrieved with first pass reperfusion had higher RBC and lower fibrin and VWF content compared to those who achieved reperfusion at greater than one pass.
Treatment of giant intracranial aneurysms using the Pipeline flow-diverting stent: Long-term results from the International Retrospective Study of the Pipeline Embolization Device (IntrePED) study
Background Traditional endovascular treatments of giant intracranial aneurysms are associated with high rates of complications and retreatment. Our objective was to examine the safety and long-term efficacy of the Pipeline Embolization Device for treatment of these aneurysms. Methods This retrospective study using the IntrePED database included all patients with giant intracranial aneurysms treated with the Pipeline device between July 2008 and February 2013. Efficacy outcomes were stratified by using the Raymond-Roy Occlusion Classification. Predefined safety outcomes included spontaneous rupture of the target aneurysm; ipsilateral intracranial hemorrhage; ischemic stroke; parent artery stenosis; and sustained cranial neuropathy. Results Sixty-six embolizations were performed to treat 63 giant intracranial aneurysms (including 2 ruptured): 49 (77.8%) in the anterior and 14 (22.2%) in the posterior circulation. The median follow-up was 22.4 (0.1–60.5) months. Class I angiographic occlusion was achieved in 72.0% (36/50). The neurological morbidity/mortality rate was 23.8% (15/63), with higher rates in the posterior circulation than in the anterior circulation (22.4% vs. 28.6%). Among seven deaths, five had neurological causes. The procedure-related neurological morbidity and mortality rates were 22.7% (15/66) and 7.6% (5/66), respectively. The spontaneous rupture rate was 4.5% (3/66). Two spontaneous ruptures (1 death), 4/4 postprocedural intracranial hemorrhages, and 6/9 ischemic events occurred within 30 days. In-stent stenosis and new-onset cranial neuropathy were not observed during the angiographic follow-up period. Conclusions Although procedure-related neurological morbidity/mortality rates were not insignificant, this study confirms the feasibility and long-term efficacy of the Pipeline Embolization Device to treat giant intracranial aneurysms.
Abstract W MP43: Platelet Testing is Associated With Worse Clinical Outcomes for Intracranial Aneurysm Patients Treated with the Pipeline Embolization Device
Objective: Controversy exists as to whether platelet inhibition testing is necessary prior to aneurysm treatment in patients premedicated with antiplatelet agents. Using the IntrePED ( Int ernational Re trospective Study of P ipeline E mbolization D evice) registry, we studied complication rates in platelet-testing and non-platelet testing groups to determine if platelet testing is associated with improved outcomes. Materials and Methods: Patients with unruptured intracranial aneurysms from the INTREPED registry were divided into those who received platelet testing (testing group) and those who did not (nontesting group). Morbidity, mortality and thrombotic and hemorrhagic complication rates were studied. Comparisons between groups for continuous variables were evaluated using t -tests and Fisher’s exact test or Pearson’s chi-square for binary categorical variables. Multivariate logistic regression analysis was performed to determine if platelet function testing was independently associated with poor outcomes adjusting for age, number of devices, aneurysm location, size, and use of multiple exchange wires. Results: When compared to the non-testing group, the platelet testing group suffered higher rates of ipsilateral intracranial hemorrhage (12/511, 2.3% versus 0/187, 0.0%, P=0.04), neurological morbidity (42/511, 8.2% versus 4/187, 2.1%, P=0.01), and combined neurological morbidity and mortality (45/511, 8.8% versus 6/187, 3.2%, P=0.01). More patients in the testing group were treated with multiple PEDs (228 patients, 38.1% versus 57 patients, 28.4%, P=0.01). On multivariate analysis, the platelet testing group had a higher odds of total major morbidity (OR=3.80, 95%CI=1.30=11.08, P=0.01) and total major morbidity and neurological mortality (OR=2.74, 95%CI=1.11-6.79). Conclusion: Our findings caution against blind acceptance of platelet testing in Pipeline patients. Further prospective studies are needed to determine if and when platelet testing in Pipeline patients is appropriate.
Abstract 44: Influence of Antithrombotics on Outcome Following Subarachnoid Hemorrhage
Objective: This study seeks to investigate the impact of antithrombotics, including Aspirin, Clopidogrel, and Warfarin, on the severity of bleeding and outcomes in patients with subarachnoid hemorrhage (SAH). We hypothesize that patients with a history of antithrombotic use have a more severe injury from SAH. Methods: Two hundred twenty-eight patients admitted to the Mayo Clinic Florida consecutively between July 2008 and July 2011 were studied retrospectively. Of this group, 77 patients had a known history of antithrombotic use while 151 did not. Both aneurysmal and non-aneurysmal cases were included in the study. Each patient’s Hunt and Hess Score, Fisher Grade, modified Rankin Scale (mRS) and Glasgow Coma Scale (GCS) were evaluated. Associations between history of antithrombotic use and severity of SAH were assessed using Spearman’s test of correlation and Mann-Whitney tests. Results: There was strong evidence of higher mRS grades in patients with a history of antithrombotic use compared to other patients (Median: 3 vs. 2, P=0.001). There was no significant difference between patients with and without a history of antithrombotic use regarding SAH Fisher grade (Median: 3 vs. 3, P=0.31) and Hunt and Hess score (Median: 2 vs. 2, P=0.93). The difference in GCS score was not statistically significant (Median: 14 vs. 15, P=0.20). Conclusion: This analysis found a significant effect of previous use of antithrombotics on overall outcome following SAH. Further analysis is needed to correlate the outcomes with specific medications and investigate the role of aggressive reversal of coagulopathy on overall outcomes.
Embotrap Extraction & Clot Evaluation & Lesion Evaluation for NeuroThrombectomy (EXCELLENT) Registry design and methods
Background Relationships between occlusive clot histopathology, baseline characteristics, imaging findings, revascularization rates, and clinical outcomes of stroke patients with large vessel occlusion (LVO) are not well understood. This study will assess the real-world experience on the efficacy and safety of using the EmboTrap device as the first approach in LVO patients and explore the associations between clot histological characteristics, imaging and clinical findings, revascularization rates, and clinical outcomes. Methods Prospective, global, multicenter, single-arm, imaging core laboratory, and clot analysis central laboratory observational registry. Adult patients (>18 years) with LVO, treated with EmboTrap as the first attempted device, will be eligible for study participation. Results Up to 1000 subjects at 50 international sites may be enrolled. Occlusive clots will be collected from at least 500 subjects. Independent central and imaging core laboratories will perform clot analysis and image adjudication. Statistical analysis will assess the association between imaging and clinical findings, clot characteristics, subject comorbidities, revascularization, and clinical outcomes. Study endpoints are functional independence (modified Rankin Scale score ≤2 at 90 days), expanded Thrombolysis In Cerebral Infarction (eTICI) score ≥2b50 rate, first-pass effect, number of passes, embolization into new territory, symptomatic intracranial hemorrhage, and 90-day mortality. Conclusions The EXCELLENT registry will provide reproducible effectiveness and safety data of EmboTrap for its use for mechanical thrombectomy. Additionally, the study will characterize the blood clots retrieved during mechanical thrombectomy with respect to their composition and histopathological analysis and potential correlations with clinical and imaging findings. Trial registration number NCT03685578 .