Angle-Free Ultrasound-assisted Technique for Difficult Lumbar Puncture to Enhance Precision and Success in Complex Spinal Anatomy: A Case Series with Longitudinal Learning Curve Analysis
Abstract Background Lumbar puncture is a routinely performed procedure, yet it presents significant challenges in patients with abnormal spinal anatomy, such as severe scoliosis or obesity. Conventional ultrasound-assisted neuraxial techniques, while superior to landmark-based methods, are constrained by two fundamental limitations: inaccurate projection of the probe’s geometric center onto the skin when the probe is tilted or rocked, and the difficulty of consistently replicating the exact probe angle during needle insertion. These limitations contribute to multiple needle passes, prolonged procedure time, and increased patient discomfort and complication risk. To address these issues, we developed a novel angle-free ultrasound-assisted technique designed to eliminate the need for replicating probe angulation during needle insertion. Case presentation: This angle-free approach was utilized for serial lumbar punctures in two patients with spinal muscular atrophy requiring repeated intrathecal nusinersen administration. Both patients presented with extreme anatomical complexity, including high body mass index (30 and 35.1 kg/m²) and severe scoliosis (Cobb angles 90° and 83°). The technique follows a three-step protocol: (1) Preprocedural imaging to select the optimal interlaminar space; (2) Ultrasound-guided postural adjustment until the probe could be held perpendicular to the bed edge and parallel to the floor while maintaining target visualization; (3) Needle insertion along this orthogonal trajectory. All 22 procedures (11 per patient) were completed successfully without persistent neurological complications. Procedural outcomes demonstrated a first-attempt success rate of 81.8% (Case 1) and 100% (Case 2), with first-pass success rates of 45.5% and 54.5%, respectively. Longitudinal analysis across sequential procedures revealed a consistent reduction in both the number of needle passes and needling time, reflecting a favorable learning curve. Conclusions The angle-free ultrasound-assisted neuraxial technique offers a valuable alternative for patients with complex spinal anatomy. By using real-time postural adjustments to achieve a needle trajectory, it enhances procedural precision and eliminates the technical hurdle of replicating probe angulation. The structured "4P" framework (Planning, Positioning, Perpendicular, Parallel) offers a practical guide for clinical adoption. The observed learning curve suggests that clinicians can readily acquire and apply this technique to manage such challenging cases.
Twice‐daily administration improves the effectiveness of 0.01% atropine for controlling myopia in slowing axial elongation and refractive progression
Abstract Purpose It remains unclear whether increasing the frequency of administration of 0.01% atropine improves its effectiveness in slowing axial elongation or refractive progression. This study compared twice‐daily 0.01% atropine administration and traditional once‐nightly administration. Methods A hybrid design was adopted incorporating both retrospective and prospective elements, with participants observed for 1 year. The control group (received saline eye drops) and once‐daily 0.01% atropine group (Atropine‐1 group) were derived from two previous trials, while the twice‐daily 0.01% atropine group (Atropine‐2 group) was enrolled prospectively. A total of 163 participants were included in the intention‐to‐treat set, with 51, 70 and 42 participants in the control, Atropine‐1 and Atropine‐2 groups, respectively. The primary outcome was the change in axial length (AL), and the secondary outcome was the change in cycloplegic spherical equivalent refraction (SER). Results Compared with the control group (0.48 ± 0.22 mm), both Atropine‐1 (0.26 ± 0.17 mm) and Atropine‐2 (0.15 ± 0.18 mm) groups showed significantly reduced AL elongation ( p < 0.001). Notably, Atropine‐2 significantly improved slowing of AL elongation compared with Atropine‐1 ( p = 0.008). The result of the secondary outcome (adjusted SER change) was consistent. Atropine‐2 was significantly more effective in slowing SER progression (−0.15 ± 0.37 D) than Atropine‐1 (−0.41 ± 0.50 D) ( p = 0.02). Based on a multivariable model, age was identified as the key covariate to perform subgroup analyses. In the younger subgroup (8–10 years), AL elongation was significantly reduced in the Atropine‐2 group (0.16 ± 0.17 mm) compared with the Atropine‐1 group (0.36 ± 0.22 mm; p = 0.002). In the older subgroup (10–12 years), there was no significant difference in progression. Consistent results were observed in the sensitivity analyses based on the per‐protocol set. Conclusion Twice‐daily administration of 0.01% atropine was more effective than once daily in slowing AL elongation and SER progression in children 8 to 10 years of age. Further investigation with extended follow‐up is warranted to substantiate this finding.
3D printable biopolymers as pelvic floor scaffolds
Our polyvinyl alcohol feedstock was prepared through carbic anhydride functionalization, UV curing during direct ink writing, and base treatment. The scaffold exhibited mechanical properties similar to pelvic floor tissue.
Recent advances of nanomaterials in imaging liver fibrosis
AbstractLiver fibrosis is a pathological process resulting from prolonged exposure to various injury factors. It is characterized by the abnormal proliferation and activation of hepatic stellate cells and excessive deposition of extracellular matrix. If left untreated, it can progress to cirrhosis, liver failure, and even liver cancer. There is currently no efficient and accurate clinical diagnostic method for early liver fibrosis. Therefore, there is an urgent need to address the challenge of accurate staging and early diagnosis of liver fibrosis in clinical practice. Recently, nanomaterials have demonstrated significant potential for enhancing the diagnosis of liver fibrosis. Nanomaterials possess the ability to precisely identify and target the microenvironment associated with liver fibrosis. By enhancing their enrichment in the target area, nanomaterials can improve imaging contrast of fibrosis lesions in the liver, thereby enabling accurate diagnosis of liver fibrosis. Accordingly, this review delves into the latest research and advancements concerning nanomaterials in liver fibrosis diagnosis.
Guidelines for the use and interpretation of assays for monitoring autophagy (4th edition)
1
Abstract Chicago Classification v4.0 (CCv4.0) is the updated classification scheme for esophageal motility disorders using metrics from high‐resolution manometry (HRM). Fifty‐two diverse international experts separated into seven working subgroups utilized formal validated methodologies over two‐years to develop CCv4.0. Key updates in CCv.4.0 consist of a more rigorous and expansive HRM protocol that incorporates supine and upright test positions as well as provocative testing, a refined definition of esophagogastric junction (EGJ) outflow obstruction (EGJOO), more stringent diagnostic criteria for ineffective esophageal motility and description of baseline EGJ metrics. Further, the CCv4.0 sought to define motility disorder diagnoses as conclusive and inconclusive based on associated symptoms, and findings on provocative testing as well as supportive testing with barium esophagram with tablet and/or functional lumen imaging probe. These changes attempt to minimize ambiguity in prior iterations of Chicago Classification and provide more standardized and rigorous criteria for patterns of disorders of peristalsis and obstruction at the EGJ.
Mucosal impedance for esophageal disease: evaluating the evidence
AbstractImpedance has traditionally been employed in esophageal disease as a means to assess bolus flow and reflux episodes. Recent and ongoing research has provided new and novel applications for this technology. Measurement of esophageal mucosal impedance, via either multichannel intraluminal impedance catheters or specially designed endoscopically deployed impedance catheters, provides a marker of mucosal integrity. Mucosal impedance has been shown to segregate gastroesophageal reflux disease (GERD) and eosinophilic esophagitis from non‐GERD controls and may play a role in predicting response to reflux intervention. More data are needed with regard to other esophageal subgroups, outcome studies, and functional disease. Our paper reviews the history of impedance in esophageal disease, the means of assessing baseline and mucosal impedance, data with regard to the newly developed mucosal impedance probes, the clinical utility of mucosal impedance in specific clinical conditions, and limitations in our existing knowledge, along with suggestions for future studies.