Citations

Showing 10 of 107964 citations.

Older men exhibit reduced efficacy of and heightened potency downregulation by intravenous pulses of recombinant human LH: a study in 92 healthy men
Veldhuis, Johannes D. , Liu, Peter Y. , Keenan, Daniel M., Takahashi, Paul Y. , Takahashi, Paul

Mayo Clinic

American Journal of Physiology-Endocrinology and Metabolism | October 5, 2011 | Volume: 302 | Issue: 1 | Pages: E117-E122

10.1152/ajpendo.00450.2011 | PMID 21971523 Get It

Direct sampling of the human spermatic veins has disclosed concomitant LH and testosterone (T) pulses, suggesting pulsatile LH concentration-dependent stimulation of T secretion. However, studies to date have examined this hypothesis using only pharmacological stimulation with hCG. The present study tests the hypothesis that age is marked by decreased T secretory responses to repeated near-physiological iv pulses of recombinant human LH administered in a Clinical Translational Science Center. Participants included 92 healthy men aged 18–75 yr with BMI 18–34 kg/m2. The contribution of endogenous LH pulses was minimized by combined injection of a selective GnRH receptor antagonist sc and successive pulses of biosynthetic LH iv. A new analytical dose response model was applied to estimate the properties of exogenous LH's drive of T secretion. Regression of LH-T dose response potency estimates on age showed that the efficacy of pulses of biosynthetic LH progressively decreased with age ( P = 0.014, r = 0.26). Testis sensitivity to exogenous LH pulses also declined with age ( P = 0.011, r = 0.27). Moreover, estimated Leydig cell downregulation by LH pulses rose significantly with age ( P = 0.039, r = 0.22). These outcomes were selective, since the recovery potency of infused LH was not affected by age but was reduced by increasing BMI ( P = 0.011, r = 0.27). Assuming stable bioactivity of infused recombinant human LH, these novel data indicate that factors associated with age and BMI attenuate LH efficacy and testis sensitivity and augment Leydig cell downregulation in healthy men.
The Transesophageal Echocardiography Probe: An Unusual Source of Pulmonary Venous Obstruction
Altarabsheh, Salah E. , Burkhart, Harold M. , Cetta, Frank , Deo, Salil V. , Altarabsheh, Salah

Mayo Clinic

World Journal for Pediatric and Congenital Heart Surgery | October 5, 2011 | Volume: 2 | Issue: 4 | Pages: 662-663

10.1177/2150135111413614 | PMID 23804485 Get It

We present a newborn patient who had surgical correction of supracardiac total anomalous pulmonary venous connection repair with an unusual cause of residual postoperative pulmonary venous obstruction secondary to compression from the transesophageal echocardiography (TEE) probe.
A comparison of high definition-image enhanced colonoscopy and standard white-light colonoscopy for colorectal polyp detection
Gross, Seth A. , Buchner, Anna M. , Cangemi, J., Picco, Michael F., Wolfsen, Herbert C. , DeVault, Kenneth R. , Loeb, David M. , Raimondo, Massimo , Woodward, Timothy A., Wallace, Michael B. , Crook, Julia E. , Wallace, Michael B

Mayo Clinic

Endoscopy | October 4, 2011 | Volume: 43 | Issue: 12 | Pages: 1045-1051

10.1055/s-0030-1256894 | PMID 21971929 Get It

New classification for probe-based confocal laser endomicroscopy in the colon
Kuiper, Teaco , Broek, F. van den, Eeden, S. van, Wallace, Michael B. , Buchner, Anna M. , Meining, Alexander, Hee, K. van, Dekker, Evelien , Meining, Alexander , Fockens, Paul , Wallace, Michael B , Dekker, Evelien

Mayo Clinic

Endoscopy | October 4, 2011 | Volume: 43 | Issue: 12 | Pages: 1076-1081

10.1055/s-0030-1256767 | PMID 21971922 Get It

Posterior Reversible Encephalopathy Syndrome as a Cause of Postoperative Blindness
Barbara, David W. , Onigkeit, James A., Smith, Benjamin , Hemmings, Hugh C.

Mayo Clinic

Anesthesiology | October 4, 2011 | Volume: 116 | Issue: 2 | Pages: 472-472

10.1097/aln.0b013e3182315ed0 | PMID 21881490 Get It

What We Know
Brull, Sorin J. , Naguib, Mohamed , Brull, Sorin J

Mayo Clinic

Anesthesiology | October 4, 2011 | Volume: 115 | Issue: 5 | Pages: 918-920

10.1097/aln.0b013e318234367d | PMID 21946093 Get It

Perioperative Nerve Injury after Total Hip Arthroplasty
Jacob, Adam K. , Mantilla, Carlos B. , Sviggum, Hans P. , Schroeder, Darrell R. , Pagnano, Mark W. , Hebl, James R., Mantilla, Carlos B , Schroeder, Darrell

Mayo Clinic

Anesthesiology | October 4, 2011 | Volume: 115 | Issue: 6 | Pages: 1172-1178

10.1097/aln.0b013e3182326c20 | PMID 21934486 Get It

Background Perioperative nerve injury (PNI) is a recognized complication of total hip arthroplasty (THA). Regional anesthesia (RA) techniques may increase the risk of neurologic injury. Using a retrospective cohort study, the authors tested the hypothesis that use of RA increases the risk for PNI after elective THA. Methods All adult patients who underwent elective THA at Mayo Clinic during a 20-yr period were included. The primary outcome was the presence of a new PNI within 3 months of surgery. Multivariable logistic regression was used to evaluate patient, surgical, and anesthetic risk factors for PNI. Results Of 12,998 patients undergoing THA, 93 experienced PNI (incidence = 0.72%; 95% CI 0.58-0.88%). PNI was not associated with type of anesthesia (OR = 0.72 for neuraxial-combined vs. general; 95% CI 0.46-1.14) or peripheral nerve blockade (OR = 0.65; 95% CI 0.34-1.21). The risk for PNI was associated with younger age (OR = 0.79 per 10-yr increase; 95% CI 0.69-0.90), female gender (OR = 1.72; 95% CI 1.12-2.64), longer operations (OR = 1.10 per 30-min increase; 95% CI 1.03-1.18) or posterior surgical approach (OR = 1.91 vs. anterior approach; 95% CI 1.22-2.99). Neurologic recovery was not influenced by the use of RA techniques in patients with PNI. Conclusions The risk for PNI after THA was not increased with the use of neuraxial anesthesia or peripheral nerve blockade. Neurologic recovery in patients who experienced PNI was not affected by the use of RA. These results support the use of RA techniques in patients undergoing elective THA given their known functional and clinical benefits.
Early Experience with Robotic-Assisted Lung Resection
Fortes, Daniel L., Tomaszek, Sandra, Wigle, Dennis A.

Mayo Clinic

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | October 4, 2011 | Volume: 6 | Issue: 4 | Pages: 237-242

10.1097/imi.0b013e31822ca40c | PMID 22437981 Get It

Objective Robotic-assisted surgery is not widely accepted for general thoracic surgical procedures, and the technical advantages, cost effectiveness, and patient benefit are in question. Few reports have been published to date regarding clinical experience with this technology. We describe our first consecutive case experience with robotic-assisted lung resection. Methods A total of 23 robotic-assisted lung resections were performed from December 1, 2008, to September 30, 2010. Patients were selected on the basis of being candidates for a minimally invasive approach to their lung resection, including criteria such as known or suspected early-stage nonsmall-cell lung cancer, no prior thoracotomy, no neoadjuvant therapy, and a body mass index (BMI) less than 40 kg/cm 2 . Data on patient characteristics and perioperative results were collected retrospectively. Results Overall 90-day mortality was 0%. The total postoperative complication rate was 39%. Conversion of the robotic-assisted procedure to a video-assisted procedure was necessary in four patients (17%), and to a thoracotomy in one patient (4%). We assessed operative time, chest tube duration, and length of hospital stay. Comparison to published outcomes from the Society of Thoracic Surgeons database demonstrated comparable outcomes to standard approaches. Conclusions Robotic-assisted lung resection is safe and feasible, with comparable short-term outcomes to published results from video-assisted or open approaches.
Electronic Health Record
Kamath, Janine R., Donahoe-Anshus, Amerett L.

Mayo Clinic

Management Engineering for Effective Healthcare Delivery | October 4, 2011 | Volume: No volume available | Issue: No issue available | Pages: 309-332

10.4018/978-1-60960-872-9.ch015 Get It

Over the last two decades there has been considerable deliberation, experience, and research in the arena of Health Information Technology (HIT), Electronic Medical Records (EMR), Electronic Health Records (EHR), and more recently, Electronic Personal Health Records (PHR). Despite the challenges involved in adopting these systems and technologies, there is consensus that they bring significant value to the delivery of trusted and affordable healthcare. The investment involved and the impact on customers, clinical and non-clinical staff, and processes are significant and far reaching. This chapter attempts to synthesize the vast amount of information, experience, and implementation perspectives related to Electronic Health Records with the intent of assisting healthcare institutions and key stakeholders make informed choices as they embark on designing, developing, and implementing an EHR. EHR considerations, challenges, opportunities, and future directions are also addressed. The chapter highlights the power of management engineering to facilitate planning, implementation, and sustainability of the EHR, a critical asset for a healthcare organization and the overall healthcare industry.
Using Simulation to Design and Improve an Outpatient Procedure Center
Huschka, Todd R., Rohleder, Thomas R., Denton, Brian T.

Mayo Clinic

Management Engineering for Effective Healthcare Delivery | October 4, 2011 | Volume: No volume available | Issue: No issue available | Pages: 216-228

10.4018/978-1-60960-872-9.ch010 Get It

Discrete-event simulation (DES) is an effective tool to for analyzing and improving healthcare processes. In this chapter we discuss the use of simulation to improve patient flow at an outpatient procedure center (OPC) at Mayo Clinic. The OPC addressed is the Pain Clinic, which was faced with high patient volumes in a new, untested facility. Simulation was particularly useful due to the uncertain patient procedure and recovery times. We discuss the simulation process and show how it helped reduce patient waiting time while ensuring the clinic could meet its target patient volumes.