Citations

Clear

120 citation(s) found for "Abu Dayyeh, Barham K".

Efficacy and Safety of Endoscopic Balloon Placement for Weight Loss in Patients With Cirrhosis Awaiting Liver Transplantation
Watt, Kymberly D. , Rizk, Monika, Jaruvongvanich, Pete, Sánchez, William , Venkatesh, Sudhakar K. , Bamlet, Heather , Tiedtke, Kathryn, Malhi, Harmeet , Grothe, Karen, Clark, Matthew M. , Venkatesh, Sudhakar K , Malhi, Harmeet , Acosta Cardenas, Andres, Sanchez, William , Heimbach, Julie K. , Port, John D. , Cárdenas, Andrés , Mundi, Manpreet S. , Dayyeh, Barham K. Abu

Mayo Clinic

Liver Transplantation | April 18, 2021 | Volume: 27 | Issue: 9 | Pages: 1239-1247

10.1002/lt.26074 | PMID 33866660 Get It

The efficacy and safety of a fluid‐filled intragastric balloon (IGB) for weight loss in patients with cirrhosis on the liver transplantation (LT) waiting list is unknown. We enrolled stable compensated patients with body mass index >35 kg/m2 and on the waiting list for IGB placement endoscopically for a maximum of 6 months. A total of 8 patients (7 men) aged mean ± SD, 56 ± 4.6 years with Model for End‐Stage Liver Disease–sodium (MELD‐Na) scores 14.1 ± 3.4 experienced weight reduction (146 ± 22.2 kg versus 127 ± 21.6 kg [P = 0.005] with IGB in place and 130 ± 24.6 kg [P = 0.014] at 6 months), with a total body weight loss of 12.2% ± 8.8% with IGBs in place and 10.9% ± 8.9% at 6 months. Body fat decreased from 48.6% ± 5.8% to 40.6% ± 6.4% (P = 0.001) and lean mass increased from 51.3% ± 6% to 59.4% ± 6.4% (P = 0.001). No change in MELD‐Na scores occurred (P = 0.770). Early balloon retrieval was attributed to accommodative symptoms (n = 2) and liver decompensation (n = 1). Mallory Weiss tears (n = 3), but no portal hypertensive bleeding, occurred. Liver decompensation and/or hepatocellular carcinoma (HCC) developed in 3 patients. A total of 4 patients with LT ± sleeve gastrectomy maintained overall weight loss. Of 4 patients who did not receive transplants, 2 experienced weight regain. IGB results in short‐term weight loss in patients with cirrhosis awaiting LT, with body fat loss without lean mass loss. Adverse effects were common. Decompensation and HCC did occur, with uncertainty of the relation to weight loss, and thus careful patient selection and close follow‐up are required.
Gastrointestinal defect closure using a novel through-the-scope helix tack and suture device compared to endoscopic clips in a survival porcine model (with video)
Hernandez, Ariosto, Marya, Neil B. , Sawas, Tarek , Rajan, Elizabeth , Gades, Naomi M. , Song, Louis M. Wong Kee , Buttar, Navtej , Wong Kee Song, Louis M, Hernandez, Ariosto, Marya, Neil B. , Dayyeh, Barham K. Abu , Storm, Andrew C.

Mayo Clinic

Endoscopy International Open | April 12, 2021 | Volume: 09 | Issue: 04 | Pages: E572-E577

10.1055/a-1370-9256 | PMID 33860074 Get It

Abstract Background and aims Endoscopic resections are associated with bleeding and perforation and may be managed with through-the-scope (TTS) clips, over-the-scope clips and endoscopic suturing. The aim of this preclinical study was to compare technical success of closure using a novel TTS tissue helix tack and suture device (X-Tack) to TTS clips in a porcine model. Materials and methods Four subjects underwent 40 mucosal resections, diameter range 25–50 mm, in the stomach (n = 24) and colon (n = 16). Closures were randomized to X-Tack (n = 24) or clip (n = 16). Animals underwent weekly endoscopic follow-up for 4 weeks. Results Technical closure with X-Tack was successful in 24 of 24 (100 %) cases and with clips in 13 of 16 cases (81.3 %) (P = 0.0001). One colonic perforation occurred and was successfully managed using X-Tack. The rate of healing was not statistically different between the groups, and all sites healed at 4 weeks including the perforation and were confirmed by histology. Conclusions Compared to TTS clip, X-Tack is superior for effecting large mucosal defect closure, including durable sealing of full-thickness perforation. There was no difference in rate of healing between devices.
Selection of Antiobesity Medications Based on Phenotypes Enhances Weight Loss: A Pragmatic Trial in an Obesity Clinic
Acosta, Andrés , Camilleri, Michael , Dayyeh, Barham Abu, Mcrae, Alison, Rossini, William, Burton, Duane D. , Clark, Matthew M. , Abu Dayyeh, Barham, Calderon, Gerardo, Burton, Duane, Acosta, Andres , Calderon-Lopez, Gerardo , González, Daniel , Singh, Sneha

Mayo Clinic

Obesity | March 24, 2021 | Volume: 29 | Issue: 4 | Pages: 662-671

10.1002/oby.23120 | PMID 33759389 Get It

ObjectiveLittle is known about the predictors of response to obesity interventions.MethodsIn 450 participants with obesity, body composition, resting energy expenditure, satiety, satiation, eating behavior, affect, and physical activity were measured by validated studies and questionnaires. These variables were used to classify obesity phenotypes. Subsequently, in a 12‐month, pragmatic, real‐world trial performed in a weight management center, 312 patients were randomly assigned to phenotype‐guided treatment or non‐phenotype‐guided treatment with antiobesity medications: phentermine, phentermine/topiramate, bupropion/naltrexone, lorcaserin, and liraglutide. The primary outcome was weight loss at 12 months.ResultsFour phenotypes of obesity were identified in 383 of 450 participants (85%): hungry brain (abnormal satiation), emotional hunger (hedonic eating), hungry gut (abnormal satiety), and slow burn (decreased metabolic rate). In 15% of participants, no phenotype was identified. Two or more phenotypes were identified in 27% of patients. In the pragmatic clinical trial, the phenotype‐guided approach was associated with 1.75‐fold greater weight loss after 12 months with mean weight loss of 15.9% compared with 9.0% in the non‐phenotype‐guided group (difference −6.9% [95% CI −9.4% to −4.5%], P < 0.001), and the proportion of patients who lost >10% at 12 months was 79% in the phenotype‐guided group compared with 34% with non‐phenotype‐guided treatment group.ConclusionsBiological and behavioral phenotypes elucidate human obesity heterogeneity and can be targeted pharmacologically to enhance weight loss.
Contamination of Single Fluid-Filled Intragastric Balloons with Orogastric Fluid is not Associated with Hyperinflation: An Ex-vivo Study and Systematic Review of Literature
Hawa, Fadi , McRae, Alison , Vargas, Eric J. , Acosta, Andrés , Bazerbachi, Fateh , Dayyeh, Barham K. Abu

Mayo Clinic

No container title available | March 18, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-318739/v1 Get It

Abstract Background Spontaneous hyperinflation is reported to the Food and Drug Administration as a complication of intragastric balloons. It is postulated that orogastric contamination of the intragastric balloon may cause this phenomenon. We sought to investigate the effects of intentional balloon contamination with gastric contents on intragastric balloon diameter and contents, whether methylene blue plays a role in preventing spontaneous hyperinflation, and review the available literature on spontaneous hyperinflation. Methods Four pairs of balloons with different combinations of sterile saline, contaminants, and methylene blue were incubated in a 37° Celsius water bath for 6 months to simulate physiological conditions with serial measurements of balloon diameter. Our findings were compared against a systematic review across multiple databases to summarize the available literature. Results Balloon mean diameter decreased from 33.5 cm ± 0.53 cm to 28.5 cm ± 0.46 cm (p < 0.0001). No significant differences were seen with the methylene blue group. Only 11 cases were found reported in the literature. Conclusions Despite contaminating intragastric balloons with gastric aspirates, hyperinflation did not occur, and other factors may be in play to account for this phenomenon, when observed. Rates of hyperinflation remain under-reported in the literature. Further controlled experiments are needed.
Endoscopic pancreatic duct stenting for pain palliation in selected pancreatic cancer patients: a systematic review and meta-analysis
Siddappa, Pradeep K. , Hawa, Fadi , Chandrasekhara, Vinay , Topazian, Mark , Bazerbachi, Fateh , Chandrasekhara, Vinay , Bazerbachi, F , Prokop, Larry J. , Murad, M. Hassan , Dayyeh, Barham K. Abu

Mayo Clinic

Gastroenterology Report | January 6, 2021 | Volume: 9 | Issue: 2 | Pages: 105-114

10.1093/gastro/goab001 | PMID 34026217 Get It

Abstract Background Abdominal pain is a debilitating symptom affecting ∼80% of pancreatic cancer (PC) patients. Pancreatic duct (PD) decompression has been reported to alleviate this pain, although this practice has not been widely adopted. We aimed to evaluate the role, efficacy, and safety of endoscopic PD decompression for palliation of PC post-prandial obstructive-type pain. Methods A systematic review until 7 October 2020 was performed. Two independent reviewers selected studies, extracted data, and assessed the methodological quality. Results We identified 12 publications with a total of 192 patients with PC presenting with abdominal pain, in whom PD decompression was attempted, and was successful in 167 patients (mean age 62.5 years, 58.7% males). The use of plastic stents was reported in 159 patients (95.2%). All included studies reported partial or complete improvement in pain levels after PD stenting, with an improvement rate of 93% (95% confidence interval, 79%–100%). The mean duration of pain improvement was 94 ± 16 days. Endoscopic retrograde cholangiopancreatography (ERCP)-related adverse events (AEs) were post-sphincterotomy bleeding (1.8%), post-ERCP pancreatitis (0.6%), and hemosuccus pancreaticus (0.6%). AEs were not reported in two patients who underwent endoscopic ultrasound-guided PD decompression. In the 167 patients with technical success, the stent-migration and stent-occlusion rates were 3.6% and 3.0%, respectively. No AE-related mortality was reported. The methodological quality assessment showed the majority of the studies having low or unclear quality. Conclusion In this exploratory analysis, endoscopic PD drainage may be an effective and safe option in selected patients for the management of obstructive-type PC pain. However, a randomized–controlled trial is needed to delineate the role of this invasive practice.
Safety and efficacy of lumen-apposing metal stents versus plastic stents to treat walled-off pancreatic necrosis: systematic review and meta-analysis
Devière, Jacques , Easler, Jeffrey J. , Peetermans, Joyce , McMullen, Edmund, Gjata, Ornela, Gourlay, Margaret L. , Chandrasekhara, Vinay , Barthet, Marc , Bazerbachi, Fateh , Lakhtakia, Sundeep , Dayyeh, Barham K. Abu

Mayo Clinic

Endoscopy International Open | October 22, 2020 | Volume: 08 | Issue: 11 | Pages: E1639-E1653

10.1055/a-1243-0092 | PMID 33140020 Get It

Abstract Background and study aims Lumen-apposing metal stents (LAMS) are increasingly used for drainage of walled-off pancreatic necrosis (WON). Recent studies suggested greater adverse event (AE) rates with LAMS for WON. We conducted a systematic review and meta-analysis to compare the safety and efficacy of LAMS with double-pigtail plastic stents (DPPS) for endoscopic drainage of WON. The primary aim was to evaluate stent-related AEs. Methods In October 2019, we searched the Ovid (Embase, MEDLINE, Cochrane) and Scopus databases for studies assessing a specific LAMS or DPPS for WON drainage conducted under EUS guidance. Safety outcomes were AE rates of bleeding, stent migration, perforation, and stent occlusion. Efficacy outcomes were WON resolution and number of procedures needed to achieve resolution. A subanalysis including non-EUS-guided cases was performed. Results Thirty studies including one randomized controlled trial (total 1,524 patients) were analyzed. LAMS were associated with similar bleeding (2.5 % vs. 4.6 %, P = 0.39) and perforation risk (0.5 % vs. 1.1 %, P = 0.35) compared to DPPS. WON resolution (87.4 % vs. 87.5 %, P = 0.99), number of procedures to achieve resolution (2.09 vs. 1.88, P = 0.72), stent migration (5.9 % vs. 6.8 %, P = 0.79), and stent occlusion (3.8 % vs. 5.2 %, P = 0.78) were similar for both groups. Inclusion of non-EUS-guided cases led to significantly higher DPPS bleeding and perforation rates. Conclusions LAMS and DPPS were associated with similar rates of AEs and WON resolution when limiting analysis to EUS-guided cases. Higher bleeding rates were seen in historical studies of DPPS without EUS guidance. Additional high-quality studies of WON treatment using consistent outcome definitions are needed.
Utilisation of artificial intelligence for the development of an EUS-convolutional neural network model trained to enhance the diagnosis of autoimmune pancreatitis
Marya, Neil B. , Powers, Patrick, Chari, Suresh T. , Gleeson, Ferga C. , Leggett, Cadman L. , Dayyeh, Barham K. Abu , Iyer, Prasad G. , Majumder, Shounak , Pearson, Randall K., Petersen, Bret T. , Rajan, Elizabeth , Sawas, Tarek , Vege, Santhi Swaroop, Chen, Shigao , Long, Zaiyang , Hough, David M., Mara, Kristin C. , Levy, Michael J. , Abu Dayyeh, Barham K , Iyer, P G , Majumder, Shounak , Sawas, T , Vege, Santhi S, Mara, Kristin, Mara, Kristin C , Leggett, Cadman L , Chari, Suresh T , Marya, Neil B. , Chandrasekhara, Vinay , Storm, Andrew C. , Vege, Santhi Swaroop , Levy, Michael J.

Mayo Clinic

Gut | October 7, 2020 | Volume: 70 | Issue: 7 | Pages: 1335-1344

10.1136/gutjnl-2020-322821 | PMID 33028668 Get It

Objective The diagnosis of autoimmune pancreatitis (AIP) is challenging. Sonographic and cross-sectional imaging findings of AIP closely mimic pancreatic ductal adenocarcinoma (PDAC) and techniques for tissue sampling of AIP are suboptimal. These limitations often result in delayed or failed diagnosis, which negatively impact patient management and outcomes. This study aimed to create an endoscopic ultrasound (EUS)-based convolutional neural network (CNN) model trained to differentiate AIP from PDAC, chronic pancreatitis (CP) and normal pancreas (NP), with sufficient performance to analyse EUS video in real time. Design A database of still image and video data obtained from EUS examinations of cases of AIP, PDAC, CP and NP was used to develop a CNN. Occlusion heatmap analysis was used to identify sonographic features the CNN valued when differentiating AIP from PDAC. Results From 583 patients (146 AIP, 292 PDAC, 72 CP and 73 NP), a total of 1 174 461 unique EUS images were extracted. For video data, the CNN processed 955 EUS frames per second and was: 99% sensitive, 98% specific for distinguishing AIP from NP; 94% sensitive, 71% specific for distinguishing AIP from CP; 90% sensitive, 93% specific for distinguishing AIP from PDAC; and 90% sensitive, 85% specific for distinguishing AIP from all studied conditions (ie, PDAC, CP and NP). Conclusion The developed EUS-CNN model accurately differentiated AIP from PDAC and benign pancreatic conditions, thereby offering the capability of earlier and more accurate diagnosis. Use of this model offers the potential for more timely and appropriate patient care and improved outcome.
Endoscopic suturing and plication in the stomach for weight loss
Jaruvongvanich, Veeravich , Maselli, Daniel B. , Matar, Reem , Dayyeh, Barham K. Abu , Abu Dayyeh, Barham K , Matar, Reem

Mayo Clinic

Minimally Invasive Therapy & Allied Technologies | September 23, 2020 | Volume: 31 | Issue: 3 | Pages: 325-331

10.1080/13645706.2020.1818582 | PMID 32965142 Get It

A Preclinical Animal Study of Combined Intragastric Balloon and Duodenal-Jejunal Bypass Liner for Obesity and Metabolic Disease
Ghoz, Hassan , Jaruvongvanich, Veeravich , Matar, Reem , Maselli, Daniel B. , Abu Dayyeh, Barham K, Matar, Reem , Beran, Azizullah , Storm, Andrew C. , Dayyeh, Barham K. Abu

Mayo Clinic

Clinical and Translational Gastroenterology | September 21, 2020 | Volume: 11 | Issue: 9 | Pages: e00234

10.14309/ctg.0000000000000234 | PMID 33094961 Get It

INTRODUCTION: Endoscopic bariatric and metabolic therapies can potentially reproduce similar gastric and small intestinal anatomic and physiologic manipulations as Roux-en-Y gastric bypass. This proof of concept animal study was aimed to assess the feasibility, safety, efficacy, and impact on gastrointestinal physiology of combined intragastric balloons (IGB) and duodenal-jejunal bypass liner (DJBL) for the treatment of obesity. METHODS: Five Ossabaw pigs were fed a high-calorie diet to develop obesity and were randomly assigned to receive IGB or DJBL in sequence. The weight gain rate was calculated. Fasting and postprandial blood samples were drawn before any intervention (serving as the baseline group) and 1 month after second device insertion (serving as the combination group) to measure gut neurohormonal changes and metabolic parameters. RESULTS: Four pigs successfully received a sequential device insertion. One pig developed duodenal sleeve prolapse that was spontaneously resolved. One pig was early terminated because of developing a central line infection. The rate of weight gain in the combination group (0.63 ± 1.3 kg/wk) was significantly lower than the baseline group (1.96 ± 2.17 kg/wk) and numerically lower than after insertion of the IGB (1.00 ± 1.40 kg/wk) or the DJBL (0.75 ± 2.27 kg/wk) alone. A trend of higher postprandial glucagon-like peptide-1 was observed in the combination group compared with the baseline group. DISCUSSION: A combination of IGB and DJBL is feasible and well tolerated. A strategy of sequential use of these devices might offer a synergistic approach that can enhance weight loss and metabolic outcomes.
Esophageal Pathophysiologic Changes and Adenocarcinoma After Bariatric Surgery: A Systematic Review and Meta-Analysis
Jaruvongvanich, Veeravich , Matar, Reem , Vantanasiri, Kornpong , Wongjarupong, Nicha , Ungprasert, Patompong , Maselli, Daniel B. , Abu Dayyeh, Barham K, Matar, Reem , Ravi, Karthik , Murad, M. Hassan , Vargas, Eric J. , Prokop, Larry J. , Dayyeh, Barham K. Abu

Mayo Clinic

Clinical and Translational Gastroenterology | August 24, 2020 | Volume: 11 | Issue: 8 | Pages: e00225

10.14309/ctg.0000000000000225 | PMID 32955206 Get It

INTRODUCTION: To assess the effects of sleeve gastrectomy (SG) and Roux-en-Y gastric bypass (RYGB) on acid reflux and esophageal motor function and to evaluate the observation of esophageal adenocarcinoma (EAC) after bariatric surgery. METHODS: We searched 5 databases for adults who underwent SG or RYGB and had esophageal pH test and/or esophageal manometry before and after surgery. A separate systemic search of observational studies and a retrospective review at 3 institutions of adults who developed EAC after these surgeries were conducted. Outcomes were changes in manometric and pH parameters and EAC cases after SG and RYGB. RESULTS: A total of 27 nonrandomized studies (SG: 612 patients; RYGB: 470 patients) were included. After SG, lower esophageal sphincter pressure and esophageal body amplitude were decreased and the risk of ineffective esophageal motility was increased. Total and recumbent acid exposure times were increased. After RYGB, an increased risk of ineffective esophageal motility was observed. Total, upright, and recumbent acid exposure times were decreased. The total reflux episodes remained unchanged but with increased nonacid reflux and decreased acid reflux events. Including our largest series, 31 EAC cases have been reported to date after SG and RYGB. DISCUSSION: This systematic review demonstrates increased acid reflux after SG and decreased acid reflux after RYGB. An observed increased nonacid reflux after RYGB might contribute to failure of gastroesophageal reflux disease improvement. This refluxate might be noxious to the esophagus, warranting further studies. RYGB might not entirely preserve esophageal function as previously believed.