Comparing Gamma Knife and CyberKnife in patients with brain metastases
Jang, Sunyoung, Curran, Bruce, Pyakuryal, Anil, Sternick, Edward S., Sio, Terence T. , Jang, Sunyoung, Lee, Sung‐Woo

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 1 | Pages: 14-26

10.1120/jacmp.v15i1.4095 | PMID 24423830 Get It

The authors compared the relative dosimetric merits of Gamma Knife (GK) and CyberKnife (CK) in 15 patients with 26 brain metastases. All patients were initially treated with the Leksell GK 4C. The same patients were used to generate comparative CK treatment plans. The tissue volume receiving more than 12 Gy (V12), the difference between V12 and tumor volume (V12net), homogeneity index (HI), and gradient indices (GI25, GI50) were calculated. Peripheral dose falloff and three conformity indices were compared. The median tumor volume was 2.50 cm3 (range, 0. 044‐19.9). A median dose of 18 Gy (range, 15‐22) was prescribed. In GK and CK plans, doses were prescribed to the 40‐50% and 77‐92% isodose lines, respectively. Comparing GK to CK, the respective parametric values were: minimum dose ( vs. , ); mean dose ( vs., ); maximum dose ( vs., ); and HI ( vs. , ). The median dosimetric indices (GK vs. CK, with range) were: RTOG_CI, 1.76 (1.12‐4.14) vs. 1.53 (1.16‐2.12), ; CI, 1.76 (1.15‐4.14) vs. 1.55 (1.18‐2.21), ; nCI, 1.76 (1.59‐4.14) vs. 1.57 (1.20‐2.30), ; GI50, 2.91 (2.48‐3.67) vs. 4.90 (3.42‐11.68), ; GI25, 6.58 (4.18‐10.20) vs. 14.85 (8.80‐48.37), . Average volume ratio (AVR) differences favored GK at multiple normalized isodose levels . We concluded that in patients with brain metastases, CK and GK resulted in dosimetrically comparable plans that were nearly equivalent in several metrics, including target coverage and minimum dose within the target. Compared to GK, CK produced more homogenous plans with significantly lower mean and maximum doses, and achieved more conformal plans by RTOG_CI criteria. By GI and AVR analyses, GK plans had sharper peripheral dose falloff in most cases.PACS number: 89.20.‐a
Total skin electron therapy in the lying‐on‐the‐floor position using a customized flattening filter to accommodate frail patients
Deufel, Christopher L. , Antolak, John A.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 14 | Issue: 5 | Pages: 115-126

10.1120/jacmp.v14i5.4309 | PMID 24036864 Get It

A total skin electron (TSE) floor technique is presented for treating patients who are unable to safely stand for extended durations. A customized flattening filter is used to eliminate the need for field junctioning, improve field uniformity, and reduce setup time. The flattening filter is constructed from copper and polycarbonate, fits into the linac's accessory slot, and is optimized to extend the useful height and width of the beam such that no field junctions are needed during treatment. A TSE floor with flattening filter (TSE FF) treatment course consisted of six patient positions: three supine and three prone. For all treatment fields, electron beam energy was 6 MeV; collimator settings were an x of 30 cm, y of 40 cm, and of 0°; and a 0.4 cm thick polycarbonate spoiler was positioned in front of the patient. Percent depth dose (PDD) and photon contamination for the TSE FF technique were compared with our standard technique, which is similar to the Stanford technique. Beam profiles were measured using radiochromic film, and dose uniformity was verified using an anthropomorphic radiological phantom. The TSE FF technique met field uniformity requirements specified by the American Association of Physicists in Medicine Task Group 30. TSE FF ranges from 4 to 4.8 mm. TSE FF photon contamination was ~ 3%. Anthropomorphic radiological phantom verification demonstrated that dose to the entire skin surface was expected to be within about of the prescription dose, except for the perineum, scalp vertex, top of shoulder, and soles of the feet. The TSE floor technique presented herein eliminates field junctioning, is suitable for patients who cannot safely stand during treatment, and provides comparable quality and uniformity to the Stanford technique.PACS number: 87
Negative margin technique — a novel planning strategy to improve dose conformation in SBRT using dynamic conformal arc delivery
Kim, Taeho , Serago, Christopher F., Vallow, Laura A., Peterson, Jennifer , Lee, Rena , Kim, Siyong , Ko, Stephen J. , Smith, Ashley A.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 14 | Issue: 5 | Pages: 79-89

10.1120/jacmp.v14i5.4283 | PMID 24036861 Get It

The purpose of this study was to introduce a planning strategy for dynamic conformal arc therapy (DCAT), named negative margin technique (NMT), and evaluate its dosimetric gain in lung stereotactic body radiation therapy (SBRT). In DCAT, the field aperture is continuously conformed to the planning target volume (PTV) with an aperture margin (AM) to compensate for the penumbra effect with gantry rotation. It is a common belief the AM should be positive (or at least ‘zero'). However, the radial penumbra width becomes significantly wider because of continuously overlapped beams in arc delivery. Therefore, we hypothesize if the ‘negative margin’ is applied in the radial direction, it would improve the PTV dose conformation while reducing normal tissue dose. For verification, trial plans were made using the NMT and compared with ‘zero margin (ZM)’ plans for five lung SBRT cases representing different situations depending on the location of the PTV and organs at risk. All plans met 95% PTV coverage with the prescription dose and spared the spinal cord below the tolerance. Two conventional conformation indices (the ratio of prescription isodose volume to the PTV (CI100) and the ratio of 50% prescription isodose volume to the PTV (CI50)) and a modified conformation index were investigated. The maximum dose at 2 cm from the PTV and the percent of lung volume receiving 20 Gy were also evaluated. Another planning simulation was performed with a total of ten randomly selected lung SBRT cases to mimic actual practice. In this simulation, optimization with ZM was first performed and further optimization using the NMT was processed for cases that could not meet a goal of with the ZM optimization. In all cases, both the and values were significantly reduced (overall, and for and , respectively). The modified conformation index values also showed similar improvement (overall, increase). Reduction of was also observed in all cases . values decreased in all cases but one (, excluding the increased case). In the random group simulation, it was possible to achieve the goal with just one NMT trial for five out of six cases that did not meet the goal in the ZM optimization. Interestingly, however, one case needed as many as six iterations to get the goal. The NMT turned out to be an effective planning strategy that could bring significant improvement of dose conformation. The NMT can be easily implemented in most clinics with no prerequisite.PACS number: 87.55.D‐
Coronary calcium quantification using contrast‐enhanced dual‐energy computed tomography scans
Yamak, Didem, Pavlicek, William , Boltz, Thomas, Panse, Prasad M., Akay, Metin

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 14 | Issue: 3 | Pages: 203-214

10.1120/jacmp.v14i3.4014 | PMID 23652239 Get It

The purpose of this study is to evaluate a direct measure of calcium burden by using dual‐energy computed tomography (DECT) during contrast‐enhanced coronary imaging, potentially eliminating the need for an extra noncontrast X‐ray acquisition. The ambiguity of separation of calcium from contrast material on contrast‐enhanced images was solved by using virtual noncontrast images obtained by DECT. A new threshold CT number was required to detect the calcium carrying potential risk for adverse coronary events on virtual noncontrast images. Two methods were investigated to determine the 130 HU threshold for DECT scoring. An in vitro anthropomorphic phantom with 29 excised patient calcium plaques inserted was used for both a linear and a logistic regression analysis. An IRB approved in vivo prospective study of six patients was also performed to be used for logistic regression analysis. The threshold found by logistic regression model to define the calcium burden on virtual noncontrast images detects the calcium carrying potential risk for adverse coronary events correctly (2.45% error rate). DECT calcium mass and volume scores obtained by using the threshold correlates with both conventional Agatston and volume scores . A conventional CT cardiac exam requires two scans, including a noncontrast scan for calcium quantification and a contrast‐enhanced scan for coronary angiography. With the ability to quantify calcium on DECT contrast‐enhanced images, a DECT cardiac exam could be accomplished with one contrast‐enhanced scan for both calcium quantification and coronary angiography.PACS numbers: 87.57.Q, 87.57.N
Association Between Pathology and Electroencephalographic Activity in Parkinson’s Disease
Caviness, John N., Beach, Thomas G. , Hentz, Joseph G. , Shill, Holly A. , Driver‐Dunckley, Erika , Driver-Dunckley, Erika D., Adler, Charles H.

Mayo Clinic

Clinical EEG and Neuroscience | February 27, 2017 | Volume: 49 | Issue: 5 | Pages: 321-327

10.1177/1550059417696179 | PMID 29161906 Get It

Introduction. The key mechanisms that connect Parkinson’s disease pathology with dementia are unclear. We tested the hypothesis that the quantitative spectral electroencephalographic measure, delta bandpower, correlates with Lewy type synucleinopathy on pathological examination in Parkinson’s disease. As a corollary hypothesis, we analyzed whether there would be delta bandpower electroencephalographic differences between Parkinson’s disease dementia cases with and without pathological criteria for Alzheimer’s disease. Methods. We used pathological examination results from 44 Parkinson’s disease subjects from our brain bank with various degrees of cognitive decline, who had undergone electroencephalography. Pathological grading for Lewy type synucleinopathy, plaques, tangles, and indications of vascular pathology in subcortical and cortical areas were correlated with the most associated electroencephalographic biomarker with Parkinson’s disease dementia in our laboratory, delta bandpower. Group differences for all spectral electroencephalographic measures were also analyzed between cases with and without pathological criteria for Alzheimer’s disease. Results. Findings revealed significant correlations between delta bandpower with Lewy type synucleinopathy, whereas indications of Alzheimer’s disease or vascular pathology had nonsignificant correlation. The strongest association was with delta bandpower and Lewy type synucleinopathy in the anterior cingulate region. Mean delta bandpower was higher in the group for Parkinson’s disease dementia with Alzheimer’s disease pathology criteria than without. Conclusions. Lewy type synucleinopathy severity appears to be more associated with increased delta bandpower than with Alzheimer’s disease pathology or indications of vascular pathology over all cases. However, the presence of Alzheimer’s pathology may associate with more cortex physiological disruption in a subset of cases.
Using four‐dimensional computed tomography images to optimize the internal target volume when using volume‐modulated arc therapy to treat moving targets
Yakoumakis, N., Winey, Brian , Killoran, Joseph H., Mayo, Charles S. , Niedermayr, Thomas, Panayiotakis, George , Lingos, Tania, Court, Laurence E. , Mayo, Charles S.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 13 | Issue: 6 | Pages: 181-188

10.1120/jacmp.v13i6.3850 | PMID 23149778 Get It

In this work we used 4D dose calculations, which include the effects of shape deformations, to investigate an alternative approach to creating the ITV. We hypothesized that instead of needing images from all the breathing phases in the 4D CT dataset to create the outer envelope used for treatment planning, it is possible to exclude images from the phases closest to the inhale phase. We used 4D CT images from 10 patients with lung cancer. For each patient, we drew a gross tumor volume on the exhale‐phase image and propagated this to the images from other phases in the 4D CT dataset using commercial image registration software. We created four different ITVs using the N phases closest to the exhale phase (where , 8, 7, 6). For each ITV contour, we created a volume‐modulated arc therapy plan on the exhale‐phase CT and normalized it so that the prescribed dose covered at least 95% of the ITV. Each plan was applied to CT images from each CT phase (phases 1–10), and the calculated doses were then mapped to the exhale phase using deformable registration. The effect of the motion was quantified using the dose to 95% of the target on the exhale phase and tumor control probability. For the three‐dimensional and 4D dose calculations of the plan where , differences in the value varied from 3% to 14%, with an average difference of 7%. For 9 of the 10 patients, the reduction in was less than 5% if eight phases were used to create the ITV. For three of the 10 patients, the reduction in the was less than 5% if seven phases were used to create the ITV. We were unsuccessful in creating a general rule that could be used to create the ITV. Some reduction (8/10 phases) was possible for most, but not all, of the patients, and the ITV reduction was small.PACS number: 87.55.D‐
Book Review
McLemore, Luke B.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 12 | Issue: 1 | Pages: 239-240

10.1120/jacmp.v12i1.3428 Get It

The Checklist Manifesto: How to Get Things Right by Atul Gawande, M.D. Metropolitan Books, Henry Hold and Company, LLC, 2009, ISBN 978‐0‐8050‐9174‐8
Systematic offset of kV and MV localization systems as a function of gantry angle
Mullins, John, Herman, Michael , Mullins, John P

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 12 | Issue: 1 | Pages: 122-128

10.1120/jacmp.v12i1.3314 | PMID 21330978 Get It

Mechanical flex of the gantry and mounted imaging panels leads to systematic offsets in localization image isocenter as a function of gantry angle for linear accelerator‐mounted image guidance systems. Subsequently, object positions obtained from localization radiographs may be offset, resulting in greater target positioning uncertainty. While current QA procedures measure kV/MV image agreement, these measurements do not provide insight to apparent isocenter position for either single imaging system as a function of gantry rotation. This study measures offset as a function of gantry angle in kV and MV imaging systems on four treatment machines to investigate the magnitude of systematic offsets and their reproducibility between systems and machines, as well as over time. It is shown that each machine and energy has a reproducible pattern of offset as a function of gantry angle that is independent of kV/MV agreement, and it varies by machine. kV and MV offset ranges are on the order of 1.5 mm in the R/L and A/P directions, and 0.5 mm in the S/I direction. Variability of kV‐MV agreement is on the order of 0.7 mm. At certain angles, combinations of localization images could show a compounded offset of over 2 mm, exceeding the desired certainty threshold. Since these trends are persistent over time for each machine, online correction for image offsets as a function of gantry angle could improve the margin of positioning uncertainty.PACS number: 87.55.Qr
A static multi‐slit collimator system for scatter reduction in cone‐beam CT
Jang, Doh-Yun, Suh, Tae Suk , Chang, Jina , Kim, Siyong

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 11 | Issue: 4 | Pages: 196-205

10.1120/jacmp.v11i4.3269 | PMID 21081885 Get It

A multiple‐slit collimator (MSC) design was introduced for scatter reduction in cone‐beam computed tomography (CBCT). Unlike most other collimators, the open and closed septa of the proposed MSC are placed in an equi‐angular interval on a circular track of the central sagittal plane. Therefore, one gantry rotation provides only the half of necessary dataset and two gantry rotations are needed to obtain full information. During the first gantry rotation, the MSC position relative to the source is fixed. For the second rotation, the MSC is rotated by the equi‐angle interval. We assume signals under the closed septa are totally attributed to scatter radiation. Then, scatter contributions under open septa are determined by interpolating them.Monte Carlo (MC) simulations for two virtual phantoms (one with a simple geometry and the other with two heterogeneities simulating the bone and the lung) were performed to evaluate the effectiveness of the system. Using the method developed, we could obtain images with significant scatter reduction. Contrast ratio (CR) improvement factors were 1.165 in a 2D projection view, and 1.210 and 1.223 at the central and peripheral slice of the reconstructed CBCT image of the simple geometry phantom.This preliminary study demonstrated that the proposed MSC, together with the imaging process technique, had a great potential to reduce scatter contribution in CBCT. Further studies will be performed to investigate the effect of various factors, such as reducing the detector size, increasing the number of history of MC simulation, and including many structures with different densities.PACS number: 87.57.C
Guest Editorial: Patient safety and errors in the application of medical radiation: our responsibility
Herman, Michael

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 11 | Issue: 2 | Pages: 2-4

10.1120/jacmp.v11i2.3329 | PMID 20592707 Get It