Treatment planning for metals using an extended CT number scale
Mullins, John, Herman, Michael , Brinkmann, Debra H. , Antolak, John A. , Mullins, John P, Grams, Michael P.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 6 | Pages: 179-188

10.1120/jacmp.v17i6.6153 | PMID 27929492 Get It

Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standard CT methods in the presence of high‐Z materials and artifacts, despite the reduced HU resolution of extended CT. Gafchromic film measurements were made for comparison to calculated doses. The method of direct dose calculation on extended CT scale was compared to our institution's standard method of manually contouring and assigning metal values on saturated CT images for each of the metal samples. Clinical patient plans with metal implants were investigated and DVHs were compared between standard CT and extended CT dose calculations. Dose calculations showed agreement within 2% between the two methods of metal characterization and the film measurement in the case of the strongest metal attenuator, cobalt‐chromium. In the clinical treatment plans, the greatest dose discrepancy between the two methods was 1.2%. This study suggests that direct dose calculation on an extended scale CT image in the presence of metal implants can produce accurate clinically viable treatment plans, thereby improving efficiency of clinical workflow and eliminating a potential source of human error by manual CT number assignment.PACS number(s): 87.55.dk
Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset
Carver, Robert L., Sprunger, Conrad P., Hogstrom, Kenneth R., Popple, Richard A. , Antolak, John A.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 3 | Pages: 52-60

10.1120/jacmp.v17i3.5885 | PMID 27167259 Get It

The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent commercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC‐calculated electron dose distributions for bolus ECT have been compared to previously measured TLD‐dose points throughout patient‐based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid‐PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and statistical uncertainties. The accuracy of the dose calculations using moderate smoothing and no smoothing were evaluated. Dose differences (eMC‐calculated less measured dose) were evaluated in terms of absolute dose difference, where 100% equals the given dose, as well as distance to agreement (DTA). Dose calculations were also evaluated for calculation speed. Results from the eMC for the retromolar trigone phantom using 1% statistical uncertainty without smoothing showed calculated dose at of the measured TLD‐dose points was within 3% dose difference or 3 mm DTA of the measured value. The average dose difference was , and the net standard deviation was 2.32%. Differences as large as 3.7% occurred immediately distal to the mandible bone. Results for the nose phantom, using 1% statistical uncertainty without smoothing, showed calculated dose at of the measured TLD‐dose points within 3% dose difference or 3 mm DTA. The average dose difference was 1.08%, and the net standard deviation was 3.17%. Differences as large as 10% occurred lateral to the nasal air cavities. Including smoothing had insignificant effects on the accuracy of the retromolar trigone phantom calculations, but reduced the accuracy of the nose phantom calculations in the high‐gradient dose areas. Dose calculation times with 1% statistical uncertainty for the retromolar trigone and nose treatment plans were 30 s and 24 s, respectively, using 16 processors (Intel Xeon E5‐2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high‐gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.PACS number(s): 87.55.kd
Measurement of tissue viscoelasticity with ultrasound
Greenleaf, James F. , Alizad, Azra

Mayo Clinic

SPIE Proceedings | February 28, 2017 | Volume: 10067 | Issue: No issue available | Pages: 1006705

10.1117/12.2256842 Get It

Perturbation of water‐equivalent thickness as a surrogate for respiratory motion in proton therapy
Matney, J, Park, Peter C., Court, Laurence E. , Zhu, X. Ron, Dong, Lei , Li, Heng , Liu, Wei , Mohan, Radhe

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 2 | Pages: 368-378

10.1120/jacmp.v17i2.5795 | PMID 27074459 Get It

Respiratory motion is traditionally assessed using tumor motion magnitude. In proton therapy, respiratory motion causes density variations along the beam path that result in uncertainties of proton range. This work has investigated the use of water‐equivalent thickness (WET) to quantitatively assess the effects of respiratory motion on calculated dose in passively scattered proton therapy (PSPT). A cohort of 29 locally advanced non‐small cell lung cancer patients treated with 87 PSPT treatment fields were selected for analysis. The variation in WET (ΔWET) along each field was calculated between exhale and inhale phases of the simulation four‐dimensional computed tomography. The change in calculated dose (ΔDose) between full‐inhale and full‐exhale phase was quantified for each field using dose differences, 3D gamma analysis, and differential area under the curve (ΔAUC) analysis. Pearson correlation coefficients were calculated between ΔDose and ΔWET. Three PSPT plans were redesigned using field angles to minimize variations in ΔWET and compared to the original plans. The median ΔWET over 87 treatment fields ranged from 1‐9 mm, while the ΔWET 95th percentile value ranged up to 42 mm. The ΔWET was significantly correlated to the ΔDose for all metrics analyzed. The patient plans that were redesigned using ΔWET analysis to select field angles were more robust to the effects of respiratory motion, as ΔAUC values were reduced by more than 60% in all three cases. The tumor motion magnitude alone does not capture the potential dosimetric error due to respiratory motion because the proton range is sensitive to the motion of all patient anatomy. The use of ΔWET has been demonstrated to identify situations where respiratory motion can impact the calculated dose. Angular analysis of ΔWET may be capable of designing radiotherapy plans that are more robust to the effects of respiratory motion.PACS number(s): 87.55.‐x
Implementation of an in‐house visual feedback system for motion management during radiation therapy
Ellerbusch, D, Cetnar, Ashley J. , James, Joshua A., Wang, Brian , Nguyen, Vi

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 1 | Pages: 421-427

10.1120/jacmp.v17i1.5817 | PMID 26894353 Get It

In this Technical Note, we describe an in‐house video goggles feedback system assembled using several commercially available products. This goggle video feedback system is currently being used at University of Louisville and Mayo Clinic for both CT simulation and linac treatment delivery. The setup details, including specific recommendations, are provided, along with an alternative option for using the video goggles system.PACS number: 07.07Hj
Alignment of multiradiation isocenters for megavoltage photon beam
Cowan, Garth, Tryggestad, E., Wang, Ken Kang‐Hsin, Zhang⋆, Yin , Ding, Kai , Armour, Elwood P. , Wang, Ken Kang‐Hsin

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 16 | Issue: 6 | Pages: 314-324

10.1120/jacmp.v16i6.5733 | PMID 26699586 Get It

The accurate measurement of the linear accelerator (linac) radiation isocenter is critical, especially for stereotactic treatment. Traditional quality assurance (QA) procedure focuses on the measurement of single radiation isocenter, usually of 6 megavoltage (MV) photon beams. Single radiation isocenter is also commonly assumed in treatment planning systems (TPS). Due to different flattening filters and bending magnet and steering parameters, the radiation isocenter of one energy mode can deviate from another if no special effort was devoted. We present the first experience of the multiradiation isocenters alignment on an Elekta linac, as well as its corresponding QA procedure and clinical impact. An 8 mm ball‐bearing (BB) phantom was placed at the 6 MV radiation isocenter using an Elekta isocenter search algorithm, based on portal images. The 3D radiation isocenter shifts of other photon energy modes relative to the 6 MV were determined. Beam profile scanning for different field sizes was used as an independent method to determine the 2D multiradiation isocenters alignment. To quantify the impact of radiation isocenter offset on targeting accuracy, the 10 MV radiation isocenter was manually offset from that for 6 MV by adjusting the bending magnet current. Because our table isocenter was mechanically aligned to the 6 MV radiation isocenter, the deviation of the table isocentric rotation from the "shifted" 10 MV radiation isocenter after bending magnet adjustment was assessed. Winston‐Lutz test was also performed to confirm the overall radiation isocenter positioning accuracy for all photon energies. The portal image method showed the radiation isocenter of the 10 MV flattening filter‐free mode deviated from others before beam parameter adjustment. After the adjustment, the deviation was greatly improved from 0.96 to 0.35 mm relative to the 6 MV radiation isocenter. The same finding was confirmed by the profile‐scanning method. The maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter was observed to linearly increase with the offset between 6 and 10 MV radiation isocenter; 1 mm radiation isocenter offset can translate to almost 2 mm maximum deviation of the table isocentric rotation from the 10 MV radiation isocenter. The alignment of the multiradiation isocenters is particularly important for high‐precision radiotherapy. Our study provides the medical physics community with a quantitative measure of the multiradiation isocenters alignment. A routine QA method should be considered, to examine the radiation isocenters alignment during the linac acceptance.PACS number: 87.55.Qr, 87.56.bd, 87.56.Fc
Seed coordinates of a new COMS‐like 24 mm plaque verified using the FARO Edge
Cutsinger, Jordan McCauley, Forsman, Renae M., Corner, Stephen, McCauley Cutsinger, Sarah E, Cutsinger, Jordan McCauley, Furutani, Keith M.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 16 | Issue: 6 | Pages: 293-301

10.1120/jacmp.v16i6.5721 | PMID 26699584 Get It

A 24 mm COMS‐like eye plaque was developed to meet the treatment needs of our eye plaque brachytherapy practice. As part of commissioning, it was necessary to determine the new plaque's seed coordinates. The FARO Edge, a commercially available measurement arm, was chosen for this purpose. In order to validate the FARO Edge method, it was first used to measure the seed marker coordinates in the silastic molds for the standard 10, 18, and 20 mm COMS plaques, and the results were compared with the standard published Task Group 129 coordinates by a nonlinear least squares match in MATLAB version R2013a. All measured coordinates were within 0.60 mm, and root mean square deviation was 0.12, 0.23, and 0.35 mm for the 10, 18, and 20 mm molds, respectively. The FARO Edge was then used to measure the seed marker locations in the new 24 mm silastic mold. Those values were compared to the manufacturing specification coordinates and were found to demonstrate good agreement, with a maximum deviation of 0.56 mm and a root mean square deviation of 0.37 mm. The FARO Edge is deemed to be a reliable method for determining seed coordinates for COMS silastics, and the seed coordinates for the new 24 mm plaque are presented.PACS number: 87.53.Jw
Structural properties of amyloid β(1‐40) dimer explored by replica exchange molecular dynamics simulations
Watts, Charles R. , Gregory, Andrew , Frisbie, Cole P., Lovas, Sándor , Gregory, Andrew J, Gregory, Andrew J.

Mayo Clinic

Proteins: Structure, Function, and Bioinformatics | February 27, 2017 | Volume: 85 | Issue: 6 | Pages: 1024-1045

10.1002/prot.25270 | PMID 28241387 Get It

ABSTRACTReplica exchange molecular dynamics simulations (300 ns) were used to study the dimerization of amyloid β(1‐40) (Aβ(1‐40)) polypeptide. Configurational entropy calculations revealed that at physiological temperature (310 K, 37°C) dynamic dimers are formed by randomly docked monomers. Free energy of binding of the two chains to each other was −93.56 ± 6.341 kJ mol−1. Prevalence of random coil conformations was found for both chains with the exceptions of increased β‐sheet content from residues 16‐21 and 29‐32 of chain A and residues 15‐21 and 30‐33 of chain B with β‐turn/β‐bend conformations in both chains from residues 1‐16, 21‐29 of chain A, 1‐16, and 21‐29 of chain B. There is a mixed β‐turn/β‐sheet region from residues 33‐38 of both chains. Analysis of intra‐ and interchain residue distances shows that, although the individual chains are highly flexible, the dimer system stays in a loosely packed antiparallel β‐sheet configuration with contacts between residues 17‐21 of chain A with residues 17‐21 and 31‐36 of chain B as well as residues 31‐36 of chain A with residues 17‐21 and 31‐36 of chain B. Based on dihedral principal component analysis, the antiparallel β‐sheet‐loop‐β‐sheet conformational motif is favored for many low energy sampled conformations. Our results show that Aβ(1‐40) can form dynamic dimers in aqueous solution that have significant conformational flexibility and are stabilized by collapse of the central and C‐terminal hydrophobic cores with the expected β‐sheet‐loop‐β‐sheet conformational motif. Proteins 2017; 85:1024–1045. © 2017 Wiley Periodicals, Inc.
Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study
Brinjikji, Waleed , Michalak, Gregory J. , Kadirvel, Ramanathan , Gilvarry, Michael , Duffy, Sharon , Kallmes, David F. , Dai, Daying , McCollough, Cynthia, McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Interventional Neuroradiology | February 27, 2017 | Volume: 23 | Issue: 3 | Pages: 279-284

10.1177/1591019917694479 | PMID 28604189 Get It

Background and purpose Because computed tomography (CT) is the most commonly used imaging modality for the evaluation of acute ischemic stroke patients, developing CT-based techniques for improving clot characterization could prove useful. The purpose of this in-vitro study was to determine which single-energy or dual-energy CT techniques provided optimum discrimination between red blood cell (RBC) and fibrin-rich clots. Materials and methods Seven clot types with varying fibrin and RBC densities were made (90% RBC, 99% RBC, 63% RBC, 36% RBC, 18% RBC and 0% RBC with high and low fibrin density) and their composition was verified histologically. Ten of each clot type were created and scanned with a second generation dual source scanner using three single (80 kV, 100 kV, 120 kV) and two dual-energy protocols (80/Sn 140 kV and 100/Sn 140 kV). A region of interest (ROI) was placed over each clot and mean attenuation was measured. Receiver operating characteristic curves were calculated at each energy level to determine the accuracy at differentiating RBC-rich clots from fibrin-rich clots. Results Clot attenuation increased with RBC content at all energy levels. Single-energy at 80 kV and 120 kV and dual-energy 80/Sn 140 kV protocols allowed for distinguishing between all clot types, with the exception of 36% RBC and 18% RBC. On receiver operating characteristic curve analysis, the 80/Sn 140 kV dual-energy protocol had the highest area under the curve for distinguishing between fibrin-rich and RBC-rich clots (area under the curve 0.99). Conclusions Dual-energy CT with 80/Sn 140 kV had the highest accuracy for differentiating RBC-rich and fibrin-rich in-vitro thrombi. Further studies are needed to study the utility of non-contrast dual-energy CT in thrombus characterization in acute ischemic stroke.