Citations

Clear

394 citation(s) found for "Kallmes, David F".

Abstract 4141987: Bionanomatrix coated flow diverters promote faster endothelialization and occlusion of brain aneurysms
Hwang, Patrick T.J. , Brott, Brigitta C. , Kadirvel, Ram , Kallmes, David F. , Jun, Ho‐Wook , Sherwood, Jennifer A. , Kadirvel, Ramanathan

Mayo Clinic

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4141987 Get It

Introduction: Intracranial aneurysms are associated with local degradation of the vessel wall resulting in the formation of a blood-filled sac. Approximately 6 million people are estimated to have intercranial saccular aneurysms in the US alone. Most aneurysms remain undetected until rupture, resulting in hemorrhage which carries a high mortality rate (>50%). Flow diverters are placed across the aneurysm neck to divert blood flow away from the sac, preventing rupture once occluded. However, flow diverters carry significant risk for thromboembolism, which is a major cause of morbidity. The elevated risk of thromboembolism is likely due to endothelial injury of the parent artery at the neck of the aneurysm. We hypothesize that the bionanomatrix can promote faster endothelialization and aneurysm occlusion thereby reducing the risk of thromboembolism after flow diverter treatment. Methods: The bionanomatrix is composed of peptide amphiphiles containing endothelial cell adhesive ligand (YIGSR) and a nitric oxide (NO) donor (KKKKK), both components critical for recruiting and retaining endothelial cells on the device. The NO releasing bionanomatrix was coated onto the flow diverters using ultrasonic spray coating, and the NO effects on endothelial cell (EC) and smooth muscle cell (SMC) proliferation on the coated devices was assessed, in vitro, using calcien-AM staining. For the in vivo study, an elastase-induced rabbit aneurysm model was created. The bionanomatrix coated and uncoated flow diverters were implanted into the rabbit aneurysm model for 4 weeks. The coated and uncoated flow diverters were then analyzed for endothelialization, smooth muscle cell proliferation, and aneurysm occlusion by angiography, gross image, and immunohistochemistry analyses. Results: In vitro , the bionanomatrix coated flow diverters significantly enhanced endothelial cell proliferation as well as reduced smooth muscle cell proliferation on the flow diverters compared to the uncoated device. In vivo, after 4 weeks, the bionanomatrix coated flow diverters demonstrated enhanced neck coverage, more complete endothelialization, and reduced smooth muscle thickness on the coated flow diverters compared to the uncoated devices as seen by gross image analysis and histology. Conclusions: The bionanomatrix coated flow diverters can successfully promote faster endothelialization and brain aneurysm occlusion which is critical for reducing the risk of thromboembolism after neurointervention.
Statins are rarely prescribed for incidentally discovered covert cerebrovascular disease: a retrospective cohort in a large electronic health record (EHR) identified using natural language processing
Leung, Lester Y. , Puttock, Eric J. , Kallmes, David F. , Chen, Wansu , Kent, David M. , Luetmer, Patrick, Kent, David M , Luetmer, Patrick H. , Fu, Sunyang , Zheng, Chengyi , Liu, Hongfang

Mayo Clinic

BMJ Neurology Open | November 11, 2024 | Volume: 6 | Issue: 2 | Pages: e000855

10.1136/bmjno-2024-000855 | PMID 39534403 Get It

Introduction While incidentally discovered covert cerebrovascular diseases (id-CCD) are associated with future stroke, it is not known if patients with id-CCD are prescribed statins. Methods Patients age ≥50 with id-CCD on neuroimaging from 2009 to 2019 with no prior ischaemic stroke, transient ischaemic attack or dementia were identified using natural language processing in a large real-world cohort. Robust Poisson multivariable regression was used to assess statin prescription among patients without prior statins. Results Among 2 41 050 patients, 74 975 patients (31.1%; 4.7% with covert brain infarcts (CBI); 29.0% with white matter disease (WMD)) had id-CCD. 53.5% (95% CI 53.2 to 53.9%) were not on statins within 6 months prior to the scan. Of those, 12.0% (95% CI 11.7 to 12.3%) were prescribed statins in the next 6 months compared with 9.3% (95% CI 9.1 to 9.4%) in those without CCD, a 2.7% (95% CI 2.4 to 3.1%) absolute increase in statin prescription for those with id-CCD. In adjusted analyses, the presence of id-CCD was only associated with minor increases in statin prescription (CBI or WMD (risk ratio (RR) 1.09, 95% CI 1.05 to 1.13), CBI alone (RR 1.34, 95% CI 1.21 to 1.47), WMD alone (RR 1.05, 95% CI 1.01 to 1.09), and CBI and WMD (RR 1.23, 95% CI 1.12 to 1.35)). Discussion Identification of id-CCD is not associated with substantial changes in statin prescription in routine clinical practice.
Bacterial signature in retrieved thrombi of patients with acute ischemic stroke—a systematic review
Zarrintan, Armin , Ghozy, Sherief , Thirupathi, K., Walden, Kalah, Brinjikji, Waleed , Kallmes, David F. , Kadirvel, Ramanathan , Thirupathi, Kasthuri, Ghozy, Sherief , Zarrintan, Armin , Thirupathi, Kasthuri

Mayo Clinic

Therapeutic Advances in Neurological Disorders | November 9, 2024 | Volume: 17 | Issue: No issue available | Pages: No page available

10.1177/17562864241296713 | PMID 39525877 Get It

Background: Acute ischemic stroke (AIS) imposes a major healthcare burden. It is hypothesized that bacterial infection could influence atherosclerosis and thrombus formation, potentially contributing to AIS. Objectives: We aim to systematically review all studies that have investigated the presence of bacterial signatures within thrombi retrieved following mechanical thrombectomy (MT) procedures in patients with AIS. Design: This systematic review is designed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 checklist. Data sources and methods: A comprehensive search was conducted in the Web of Sciences, PubMed, Scopus, and Embase databases to identify relevant studies. Results: The literature search and screening included 11 studies involving 674 patients, with 414 (61.4%) being male and 260 (38.6%) females. Among all the patients, 393 (58.3%) were positive for bacterial presence in their retrieved thrombi. The most utilized technique for bacterial signature detection was bacterial DNA extraction followed by polymerase chain reaction amplification of the 16S rRNA gene sequence. Staphylococcus aureus was the most studied bacteria among the studies analyzed. Conclusion: Bacterial infections and the presence of bacteria within thrombi may significantly contribute to AIS by initiating or exacerbating atherosclerosis or thrombosis. Understanding the mechanisms by which bacteria affect vascular health is crucial for developing effective preventive and therapeutic strategies for stroke patients.
Modeling Fibrin Accumulation on Flow‐Diverting Devices for Intracranial Aneurysms
Cebral, Juan R. , Mut, Fernando , Löhner, Rainald , Marsh, Laurel , Chitsaz, Alireza , Bilgin, Cem , Bayraktar, Esref Alperen , Kallmes, David F. , Kadirvel, Ramanathan , Bayraktar, Esref Alperen , Kallmes, David, Marsh, Laurel , Cebral, Juan R , Bilgin, Cem

Mayo Clinic

International Journal for Numerical Methods in Biomedical Engineering | November 6, 2024 | Volume: 40 | Issue: 12 | Pages: No page available

10.1002/cnm.3883 | PMID 39501466 Get It

ABSTRACT The mechanisms leading to aneurysm occlusion after treatment with flow‐diverting devices are not fully understood. Flow modification induces thrombus formation within the aneurysm cavity, but fibrin can simultaneously accumulate and cover the device scaffold, leading to further flow modification. However, the interplay and relative importance of these processes are not clearly understood. A computational model of fibrin accumulation and flow modification after flow diversion treatment of cerebral aneurysms has been developed under the guidance of in vitro experiments and observations. The model is based on the loose coupling of flow and transport‐reaction equations that are solved separately by independent codes. Interaction or reactive terms account for thrombin production from prothrombin stimulated by thrombogenic metallic wires and inhibition by antithrombin as well as fibrin production from fibrinogen stimulated by thrombin and flow shear stress, and fibrin adhesion to device wires and already attached fibrin. The computational model was demonstrated and tested on idealized vessel and aneurysm geometries. The model was able to reproduce the salient features of fibrin accumulation after the deployment of flow‐diverting devices in idealized in vitro models of cerebral aneurysms. Namely, fibrin production in regions of high shear stress, initial accumulation at the inflow zone, and progressive occlusion of the device and corresponding flow attenuation. The computational model linking flow dynamics to fibrin production, transport, and adhesion can be used to investigate and better understand the effects that lead to fibrin accumulation and the resulting aneurysm inflow reduction and intra‐aneurysmal flow modulation.
Safety and efficacy of intravenous thrombolytic therapy in the extended window up to 24 hours: A systematic review and meta‐analysis
Al‐Janabi, Omar , Toruno, Michelle A. , Mahmood, Yamama M., Ghozy, Sherief , Yaghi, Shadi , Kallmes, David F. , Al-Janabi, Omar M , Jazayeri, Seyed Behnam , Ghozy, Sherief , Yaghi, Shadi , Rabinstein, Alejandro A.

Mayo Clinic

Annals of Clinical and Translational Neurology | October 29, 2024 | Volume: 11 | Issue: 12 | Pages: 3310-3319

10.1002/acn3.52239 | PMID 39469780 Get It

AbstractObjectiveAbout 25% of patients with acute ischemic stroke (AIS) present within the intravenous thrombolytic (IVT) therapeutic window of <4.5 h. This study is to elucidate the safety and efficacy of IVT in the extended therapeutic window (ETW) in patients with AIS.MethodsUsing PRISMA guidelines, a systematic review was conducted using PubMed, Embase, and Scopus. A rigorous risk of bias assessment was conducted using the RoB2 tool. Rates of excellent and good functional outcome (mRS 0–1 and mRS 0–2) at 90 days, symptomatic intracranial hemorrhage (sICH), and mortality at 90 days were pooled using generalized linear mixed model and compared with controls. Meta‐analyses were conducted employing random‐effect models with risk ratio (RR) and 95% confidence intervals (CIs). Subgroup analysis was performed to assess the effect of imaging modalities used for patient selection.ResultsEight randomized controlled trials (n = 2221, 59% male) were included. At 90 days IVT showed higher rates of functional recovery: mRS 0–1: RR 1.21 95% CI 1.1–1.34, p < 0.001, and mRS 0–2: RR 1.11 95% CI 1.03–1.18, p = 0.004. Rate of mortality at 90 day was not different between groups: RR 1.17 95% CI 0.93–1.48, p = 0.17. However, the rate of sICH was higher among IVT group: RR 2.93 95% CI 1.53–5.6, p = 0.001. Subgroup analysis showed higher mRS 0–1 among patients who were selected based on perfusion imaging (p < 0.05).InterpretationThe use of IVT in AIS in ETW is beneficial especially with the use of perfusion imaging for patients' selection.
Comparative analysis of single plane and biplane angiography systems for mechanical thrombectomy for acute ischemic stroke: a systematic review and meta-analysis
Orscelik, Atakan , Bilgin, Cem , Cortese, Jonathan , Cayme, Joshua J , Şenol, Yiğit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Beizavi, Zahra , Brinjikji, Waleed , Kallmes, David F. , Senol, Yigit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Brinjikji, Waleed , Orscelik, Atakan , Cortese, Jonathan , Zandpazandi, Sara

Mayo Clinic

Journal of NeuroInterventional Surgery | October 22, 2024 | Volume: 17 | Issue: 6 | Pages: 567-573

10.1136/jnis-2024-022381 | PMID 39438134 Get It

Background The choice of angiography system could influence the outcomes of mechanical thrombectomy (MT) in the treatment of acute ischemic stroke (AIS), but its impact is not yet well understood. This study aims to compare the clinical and technical outcomes of MT performed with single plane versus biplane angiography systems. Method We conducted a systematic review and meta-analysis, following PRISMA guidelines, by searching PubMed, Embase, Web of Science, and Scopus to include studies on patients with AIS who underwent MT with either single plane or biplane angiography up to May 4, 2024. The primary outcome was a favorable outcome defined as a modified Rankin Scale (mRS) score of 0–2 at 90 days after the procedure. Data were analyzed using a random-effects model and heterogeneity was assessed using the I2 test and Q statistics. Results Five studies with a total of 1562 patients were analyzed. Of these, 68.4% were treated with biplane systems and 31.6% with single plane systems. Single plane angiography was associated with a significantly higher rate of favorable outcomes (OR 1.43; 95% CI 1.13 to 1.80; P<0.01). There were no significant differences in successful recanalization, periprocedural complications, procedure time, total fluoroscopy time, or contrast volume between the two systems. Conclusion While single plane angiography systems may offer slightly better outcomes in MT for AIS, both systems appear equally effective in most clinical and technical perspectives, suggesting that system selection may be more dependent on availability and procedural requirements rather than inherent superiority. Our findings may encourage clinicians to use single-plane angiography in settings where the biplane angiography suite availability is limited, but it should be noted that this observation may have been influenced by selection bias, particularly since the larger studies included in our meta-analysis did not observe this effect in adjusted analyses for potential confounder factors.
Can the clot meniscus and claw signs predict thrombectomy and clinical outcomes in patients with stroke? A systematic review and meta-analysis
Cortese, Jonathan , Ghozy, Sherief , Gajjar, Aryan , Douri, Dani, Kadirvel, Ramanathan , Kallmes, David F. , Reda, Abdullah , Cortese, Jonathan , Ghozy, Sherief , Kadirvel, Ram , Reda, Abdullah

Mayo Clinic

Journal of NeuroInterventional Surgery | October 11, 2024 | Volume: 17 | Issue: 9 | Pages: 932-938

10.1136/jnis-2024-022322 | PMID 39393916 Get It

Background The angiographic shape of an occlusion, like the clot meniscus sign and the claw sign, has been reported to potentially impact the recanalization rate and clinical outcome in patients undergoing mechanical thrombectomy for acute ischemic strokes. Method Following PRISMA guidelines, a systematic literature search was conducted across PubMed, Scopus, Embase and Web of Science databases. Patients were grouped into clot meniscus/claw sign positive and negative groups based on the definitions obtained from each study. Primary outcomes included technical success, with a meta-analysis performed using a random-effects model to calculate proportions and odds ratios (OR) with 95% confidence intervals (Cl). Results We included seven studies recruiting 1572 patients. The results indicated that the positive and negative groups had comparable first-pass effect (OR 1.95; 95% CI 0.76 to 5.01; P=0.167) and final recanalization (OR 1.36; 95% CI 0.81 to 2.27; P=0.248) rates. However, the rate of having a favorable functional outcome was significantly higher in the positive group than in the negative sign group (OR 1.91; 95% CI 1.25 to 2.92; P<0.003). Within the sign-positive population, the use of contact aspiration was associated with a significantly higher rate of recanalization compared with using a stent retriever (OR 0.18; 95% CI 0.07 to 0.49; P<0.001). This result did not translate into a clinical impact, as both stent retriever and contact aspiration showed comparable rates of functional independence at 3 months (OR 0.22; 95% CI 0.02 to 2.33; P=0.210). Conclusion The presence of the clot meniscus/claw sign is not associated with recanalization outcomes after thrombectomy. However, it might be a good sign to predict which thrombectomy technique might be associated with better recanalization, although current evidence may need further confirmation.
Braids and beyond: a comprehensive study on pipeline device braid stability from PREMIER data
Rodriguez‐Erazú, Fernanda , Cortez, Gustavo M , Gutierrez‐Aguirre, Salvador F. , Toledo, Otavio F. De , Aghaebrahim, Amin, Sauvageau, Eric , Kallmes, David F. , Fiehler, Jens , Hanel, Ricardó A. , Gutierrez-Aguirre, Salvador F , De Toledo, Otavio Frederico , Aghaebrahim, Amin , Sauvageau, Eric , Fiehler, Jens , Hanel, Ricardo A , Lopes, Demetrius K.

Mayo Clinic

Journal of NeuroInterventional Surgery | October 2, 2024 | Volume: 17 | Issue: 12 | Pages: 1362-1367

10.1136/jnis-2024-022350 | PMID 39357888 Get It

Background The pipeline embolization device (PED) has been increasingly used to treat brain aneurysms; however, concerns have been raised about braid stability with newer drawn filled tubing technology devices. Objective To evaluate braid stability of PED early generations using data from the PREMIER trial. Methods All consecutive intracranial aneurysms treated with PED (Classic and Flex) within the PREMIER trial were reviewed for braid stability (fish mouthing, foreshortening, braid bump, braid collapsing). Immediate postprocedure cone-beam CT and angiography were compared with 1- and 2- years' follow-up. Analyses included safety, measured with the modified Rankin Scale (mRS) score, including +1 mRS point and a good clinical outcome (mRS score 0–2), vessel stenosis ≥50%, effectiveness measured with Raymond-Roy Scale, and re-treatment rates. Results 133/141 aneurysms had a complete dataset. 8/133 (6%) aneurysms showed braid deformations. Inter-reader agreement was excellent (κ=0.83). Braid deformations were statistically significantly associated with in-stent vessel stenosis >50% (P=0.029), without impact on effectiveness or safety. Fish mouthing was found in 1/133 (0.75%) at 1 year, causing >50% vessel stenosis. Foreshortening occurred in 6/133 (4.5%), and braid bump in 1/133 (0.75%) associated with severe in-stent stenosis. Four other cases (3.0%) of asymptomatic in-stent stenosis due to neointimal hyperplasia were seen without braid changes. No new braid stability deformations were found at the 2-year follow-up. Conclusion Our study demonstrates excellent braid stability among patients treated with the PED Classic and Flex in the PREMIER trial. Within the uncommon braid changes observed, none affected the PED safety or efficacy. Trial registration number NCT02186561 .
Endovascular thrombectomy for severe cerebral venous thrombosis: A comprehensive meta-analysis assessing safety and efficacy
Ghozy, Sherief , Tolba, Hatem , Abdelghaffar, Mariam , Kobeissi, Hassan , Ghaith, Hazem S. , Abbas, Alzhraa Salah , Kadirvel, Ramanathan , Brinjikji, Waleed , Kallmes, David F. , Kobeissi, Hassan , Abbas, Alzhraa S, Kadirvel, Ram , Kallmes, David F , Ghozy, Sherief , Orscelik, Atakan , Abbas, Alzhraa Salah

Mayo Clinic

Interventional Neuroradiology | September 30, 2024 | Volume: 32 | Issue: 4 | Pages: 1765-1774

10.1177/15910199241285071 | PMID 39344306 Get It

Background Cerebral sinus venous thrombosis (CSVT) has traditionally been treated medically with systemic anticoagulation. Recent advances in endovascular therapy (EVT) may represent an alternative treatment to medical therapy for CSVT. We conducted a systematic review and meta-analysis to evaluate the use of EVT for CSVT. Methods We conducted a systematic literature review using PubMed, Embase, Scopus, and Web of Science. We included studies that reported outcomes following EVT for CSVT. The primary outcome of interest was rate of modified Rankin Scale (mRS) 0–2. Secondary outcomes of interest were rates of complete, partial, and failed recanalization, mortality, and new or expansion of hematoma. We calculated pooled rates (%) and their corresponding 95% confidence intervals (CIs). Results Thirty-eight studies with 682 patients were included. Rate of mRS 0–2 was 82.6% (95% CI, 75.3%–88.0%). Rate of complete recanalization was 60.9% (95% CI, 49.1%–71.5%), rate of partial recanalization was 34.2% (95% CI, 24.1%–45.9%), and rate of failed recanalization was 5.4% (95% CI, 3.1%–9.2%). Rate of mortality was 6.7% (95% CI, 4.1%–10.8%), and rate of new hematoma or expansion of hematoma was 5.1% (2.9%–8.8%). Conclusions In this systematic review and meta-analysis, EVT for CSVT was associated with favorable rates of mRS 0–2 and recanalization. Furthermore, EVT was associated with a promising safety profile. Future prospective, comparative studies are warranted to assess EVT for CSVT.
pRESET thrombectomy device outcomes in patients with acute ischemic stroke: A systematic review and meta-analysis
Cwajna, Mark , Kobeissi, Hassan , Kendall, Nicholas , Elgazzar, Tasnim , Ghozy, Sherief , Brinjikji, Waleed , Kallmes, David F. , Cwajna, Mark , Kobeissi, Hassan , Ghozy, Sherief , Kallmes, David F , Hamouda, Abdelrahman M.

Mayo Clinic

Interventional Neuroradiology | September 27, 2024 | Volume: 32 | Issue: 4 | Pages: 1749-1755

10.1177/15910199241286753 | PMID 39327944 Get It

Background Many devices are used to perform mechanical thrombectomy in the setting of large vessel occlusion acute ischemic stroke. We sought to evaluate the efficacy and safety of pRESET stent-retriever systems. Methods We conducted a comprehensive systematic review and meta-analysis following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Relevant studies up to March 2024 were retrieved from PubMed, Scopus, Web of Science, and Embase databases. Results A total of 8 papers met the inclusion/exclusion criteria comprising a total of 1140 participants (average age 72.4 ± 11.9, female percentage (50%). Preintervention intravenous thrombolysis was utilized in 46.5% (range 32.9–65.4) of patients, with a median National Institute of Health Stroke Scale at presentation of 15 (range 0–38). The middle cerebral artery was the most commonly affected artery, with a prevalence of 76.4% (range 62.8–100). The pRESET stent-retriever systems demonstrated a first-passing effect rate of 53.4% [95% confidence interval [CI] 44.8; 61.7] and a final thrombolysis in cerebral infarction 2b-3 grade rate of 90.41% [95% CI 82.13; 95.08]. Ninety-day modified Rankin Scale (0–2) rate was 42.2% [95% CI 27.6; 58.4], and 90-day mortality rate was 15.1% [95% CI 9.8; 22.6]. Postintervention hemorrhage occurred at a rate of 28.6% [CI 17.2; 43.6]. Conclusion Our systematic review and meta-analysis describes the efficacy of the pRESET stent retriever system in managing acute ischemic stroke patients. The pRESET device was found to have a similar safety and efficacy profile to other mechanical thrombectomy devices currently in use.