Back to Authors

Kallmes, David

A5137469292 | I1330342723

Mayo Clinic

Mayo Clinic

Citations 13

Flow diverter mechanism influenced by concurrent processes: progressive neck coverage and intrasaccular thrombus formation

Journal of NeuroInterventional Surgery | October 9, 2026 | Volume: No volume available | Issue: No issue available | Pages: jnis-2026-025874

10.1136/jnis-2026-025874 | PMID 42855284

Effect of Thrombus Composition on Functional Outcomes After Ischemic Stroke Therapy: A GRADE-Assessed Systematic Review and Meta-Analysis

Asian Journal of Neurosurgery | September 17, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0046-1829092

Abstract Stroke thrombi are heterogeneous; their composition influences their mechanical properties, including stiffness, elasticity, and adhesiveness, which in turn affect their response to therapy. Systemic characterization of the thrombi components could help select therapeutic techniques and anticipate outcomes. We conducted a systematic review and meta-analysis to evaluate associations between thrombi composition and angiographic and functional outcomes in acute ischemic stroke (AIS). Up to May 2025, relevant studies were sourced from four databases: PubMed, Web of Science, Scopus, and Embase. We included cohort studies whose populations are patients with AIS in relation to thrombi composition. Thirty-six studies involving 5,462 patients matched our eligibility criteria. Angiographic success (Thrombolysis in Cerebral Infarction ≥ 2b/3) did not differ significantly between red blood cell (RBC)-rich and fibrin-rich thrombi (risk ratio [RR] 1.02, 95% confidence interval [CI] 0.85–1.22; p = 0.84; I 2 = 63.8%; very low certainty). However, thrombi from patients with good angiographic outcomes had a significantly higher RBC content compared to patients with poor outcomes (mean difference = 7.22%, 95% CI 3.31–11.13; p < 0.001; low certainty). No significant difference was observed between RBC-rich and fibrin-rich thrombi regarding functional independence at 90 days (modified Rankin Scale 0–2) (RR = 1.22, 95% CI 0.73–2.05; p = 0.31; low certainty). While RBC-rich thrombi are associated with more favorable angiographic performance, thrombus composition alone does not predict functional outcomes. Stroke outcomes remain multifactorial, dominated by time to reperfusion, collateral circulation, and baseline severity. Preinterventional assessment of clot composition via imaging or biomarkers may support individualized therapy but should complement, not replace, other prognostic determinants.
Modeling Perforator Occlusion After Flow Diversion

International Journal for Numerical Methods in Biomedical Engineering | August 20, 2026 | Volume: 42 | Issue: 8 | Pages: No page available

10.1002/cnm.70207 | PMID 42619559

ABSTRACT Endoluminal flow diverters are increasingly used to treat cerebral aneurysms. Despite good aneurysm occlusion efficacy, delayed ischemic complications due to side branch or perforator occlusion remain a serious concern. However, the mechanisms leading to side branch occlusion are poorly understood. To investigate these mechanisms, a combination of animal and computational models was utilized. Flow diverters were deployed in four rabbit superior mesenteric artery (SMA) and studied with computational fluid dynamics (CFD) and a previously developed fibrin dynamics model. Subject‐specific vascular models were reconstructed from 3D rotational angiography images and flow conditions were derived from Doppler ultrasound velocity measurements. Flow diverting devices were virtually deployed within the vascular models under guidance from angiography images. Coupled flow and fibrin production, transport, and adhesion simulations were carried out and the effects of fibrin accumulation at the origin of jailed side branches after flow diverter implantation were analyzed. The results of the computational models suggest significant fibrin accumulation across the struts of all flow diverting devices jailing side branches. Larger accumulation was observed at the more distal branches. However, minor flow alterations were produced which were not detectable in angiography sequences. These results were in agreement with experimental observations. On the other hand, fibrin accumulation alone did not explain complete side branch occlusions, which are likely the result of the interaction between initial fibrin accumulation and subsequent cell migration from the peripheral parent artery.
Evaluation of Hemodynamic Environment of Intracranial Aneurysms After Flow Disruption Based on Angiographic Signatures

International Journal for Numerical Methods in Biomedical Engineering | June 1, 2026 | Volume: 42 | Issue: 6 | Pages: No page available

10.1002/cnm.70179 | PMID 42219373

ABSTRACT Incomplete aneurysm occlusion after flow disruption treatment strongly depends on the persistence of strong flow into the aneurysm, which in turn depends on the aneurysm and parent artery geometry as well as the device placement. However, at the time of treatment it remains challenging to predict future outcomes (complete or incomplete occlusion). This paper describes a strategy to evaluate the local hemodynamic environment created immediately after flow‐modifying device deployment to treat cerebral aneurysms and connect it to the subsequent long‐term outcomes. The approach is based on the concept of angiographic signatures that can be extracted from DSA sequences or computational models and represented as images that can be used to compare different aneurysmal environments. The methodology is demonstrated on two small series of four experimental rabbit aneurysms each, treated with either intrasaccular flow disruptors or endoluminal flow diverters. Noticeable differences in the angiographic signatures of completely and incompletely occluded aneurysms at follow‐up were observed. Specifically, larger values of mean transit times and longer time‐to‐peaks were observed deeper into the aneurysms that remained incompletely occluded in both series. The findings suggest that angiographic signatures can be used to assess the underlying hemodynamic environment immediately after device implantation and prognosticate the likelihood of future complete or incomplete occlusion.
Influence of Vessel Geometry, Flow Conditions, and Thrombin Concentration on Fibrin Accumulation and Cerebral Aneurysm Occlusion After Flow Diversion

International Journal for Numerical Methods in Biomedical Engineering | December 26, 2024 | Volume: 41 | Issue: 1 | Pages: No page available

10.1002/cnm.3904 | PMID 39725674

ABSTRACT As the number of cerebral aneurysms treated with flow diverters continues to increase, it is important to understand what factors influence not only thrombus formation within the aneurysm cavity but also fibrin accumulation across the device and its associated disruption and blockage of the inflow stream. Both processes contribute to the eventual occlusion of the aneurysm or its continued patency and incomplete occlusion which may require future re‐treatment. To investigate fibrin accumulation on flow diverters placed across the neck of cerebral aneurysms, a previously developed computational model that couples flow and fibrin dynamics is used in combination with experimental in vitro models of cerebral aneurysms treated with flow diverters. Fibrin accumulation was previously investigated in four glass models of cerebral aneurysms with varying parent artery geometries placed in a flow loop at different flow rates. Corresponding computational models were constructed and compared with the experimental findings. The computational model based on fibrin production stimulated from flow shear stress and subsequent adhesion to device wires was able to reproduce and explain the fibrin accumulation patterns observed in the experimental aneurysms treated with flow diverters. Specifically, these models indicated that increasing vessel curvature, flow rate, and thrombin concentration induced faster fibrin accumulation and associated aneurysm inflow disruption and blockage. The models described and tested in this paper are valuable to understand the detailed mechanisms leading to aneurysm occlusion and healing or incomplete occlusions after treatment with flow diverting devices.
Modeling Fibrin Accumulation on Flow‐Diverting Devices for Intracranial Aneurysms

International Journal for Numerical Methods in Biomedical Engineering | November 6, 2024 | Volume: 40 | Issue: 12 | Pages: No page available

10.1002/cnm.3883 | PMID 39501466

ABSTRACT The mechanisms leading to aneurysm occlusion after treatment with flow‐diverting devices are not fully understood. Flow modification induces thrombus formation within the aneurysm cavity, but fibrin can simultaneously accumulate and cover the device scaffold, leading to further flow modification. However, the interplay and relative importance of these processes are not clearly understood. A computational model of fibrin accumulation and flow modification after flow diversion treatment of cerebral aneurysms has been developed under the guidance of in vitro experiments and observations. The model is based on the loose coupling of flow and transport‐reaction equations that are solved separately by independent codes. Interaction or reactive terms account for thrombin production from prothrombin stimulated by thrombogenic metallic wires and inhibition by antithrombin as well as fibrin production from fibrinogen stimulated by thrombin and flow shear stress, and fibrin adhesion to device wires and already attached fibrin. The computational model was demonstrated and tested on idealized vessel and aneurysm geometries. The model was able to reproduce the salient features of fibrin accumulation after the deployment of flow‐diverting devices in idealized in vitro models of cerebral aneurysms. Namely, fibrin production in regions of high shear stress, initial accumulation at the inflow zone, and progressive occlusion of the device and corresponding flow attenuation. The computational model linking flow dynamics to fibrin production, transport, and adhesion can be used to investigate and better understand the effects that lead to fibrin accumulation and the resulting aneurysm inflow reduction and intra‐aneurysmal flow modulation.
Endovascular Therapy Versus Medical Therapy Alone for Basilar Artery Stroke: A Systematic Review and Meta‐Analysis Through Nested Knowledge

Stroke: Vascular and Interventional Neurology | February 8, 2022 | Volume: 2 | Issue: 3 | Pages: No page available

10.1161/svin.121.000147 | PMID 41583624

Background Endovascular thrombectomy (EVT) is an effective treatment for acute ischemic stroke attributable to the anterior circulation large‐vessel occlusion. Randomized trials of patients with posterior circulation large‐vessel occlusion (PC‐LVO) have failed to show a benefit of EVT over medical therapy (MEDT). We performed a systematic review and meta‐analysis to understand better whether EVT is beneficial for PC‐LVO. Methods Using the Nested Knowledge AutoLit living review platform, we identified randomized control trials and prospective studies that reported functional outcomes in patients with PC‐LVO treated with EVT versus MEDT. The primary outcome variable was 90‐day modified Rankin scale score of 0 to 3, and secondary outcome variables included 90‐day modified Rankin scale score of 0 to 2, 90‐day mortality, and rate of symptomatic intracranial hemorrhage. A separate random effects model was fit for each outcome measure to calculate pooled odds ratios. Results Three studies with 1248 patients, 860 in the EVT arm and 388 in the MEDT arm, were included in the meta‐analysis. The favorable outcome rate (modified Rankin scale score of 0–3) in patients undergoing EVT was 39.9% (95% CI, 30.6%–50.1%) versus 24.5% in patients undergoing MEDT (95% CI, 9.6%–49.8%). Patients undergoing EVT had higher modified Rankin scale score of 0 to 2 rates (31.8% [95% CI, 25.7%–38.5%] versus 19.7% [95% CI, 7.4%–42.7%]) and lower mortality (42.1% [95% CI, 35.9%–48.6%] versus 52.8% [95% CI, 33.3%–71.5%]) compared with patients undergoing MEDT, but neither result was statistically significant. Patients undergoing EVT were more likely to develop symptomatic intracranial hemorrhage (odds ratio, 10.36; 95% CI, 3.92–27.40). Conclusions EVT treatment of PC‐LVO trended toward superior functional outcomes and reduced mortality compared with MEDT despite a trend toward increased symptomatic intracranial hemorrhage in patients undergoing EVT. Existing randomized and prospective studies are insufficiently powered to demonstrate a benefit of EVT over MEDT in patients with PC‐LVO.
Response to: Some Questions About the Article “The Efficacy and Safety of Vertebral Augmentation: A Second ASBMR Task Force Report”

Journal of Bone and Mineral Research | November 19, 2019 | Volume: 35 | Issue: 1 | Pages: 212-213

10.1002/jbmr.3906 | PMID 31743502

Response Letter to the Editor—Diamond et al, JBMR

Journal of Bone and Mineral Research | May 28, 2019 | Volume: 34 | Issue: 6 | Pages: 1185-1186

10.1002/jbmr.3724 | PMID 31135998

The Efficacy and Safety of Vertebral Augmentation: A Second ASBMR Task Force Report

Journal of Bone and Mineral Research | January 24, 2019 | Volume: 34 | Issue: 1 | Pages: 3-21

10.1002/jbmr.3653 | PMID 30677181

ABSTRACT Vertebral augmentation is among the current standards of care to reduce pain in patients with vertebral fractures (VF), yet a lack of consensus regarding efficacy and safety of percutaneous vertebroplasty and kyphoplasty raises questions on what basis clinicians should choose one therapy over another. Given the lack of consensus in the field, the American Society for Bone and Mineral Research (ASBMR) leadership charged this Task Force to address key questions on the efficacy and safety of vertebral augmentation and other nonpharmacological approaches for the treatment of pain after VF. This report details the findings and recommendations of this Task Force. For patients with acutely painful VF, percutaneous vertebroplasty provides no demonstrable clinically significant benefit over placebo. Results did not differ according to duration of pain. There is also insufficient evidence to support kyphoplasty over nonsurgical management, percutaneous vertebroplasty, vertebral body stenting, or KIVA®. There is limited evidence to determine the risk of incident VF or serious adverse effects (AE) related to either percutaneous vertebroplasty or kyphoplasty. No recommendation can be made about harms, but they cannot be excluded. For patients with painful VF, it is unclear whether spinal bracing improves physical function, disability, or quality of life. Exercise may improve mobility and may reduce pain and fear of falling but does not reduce falls or fractures in individuals with VF. General and intervention-specific research recommendations stress the need to reduce study bias and address methodological flaws in study design and data collection. This includes the need for larger sample sizes, inclusion of a placebo control, more data on serious AE, and more research on nonpharmacologic interventions. Routine use of vertebral augmentation is not supported by current evidence. When it is offered, patients should be fully informed about the evidence. Anti-osteoporotic medications reduce the risk of subsequent vertebral fractures by 40–70%. © 2018 American Society for Bone and Mineral Research.