ABSTRACT Endoluminal flow diverters are increasingly used to treat cerebral aneurysms. Despite good aneurysm occlusion efficacy, delayed ischemic complications due to side branch or perforator occlusion remain a serious concern. However, the mechanisms leading to side branch occlusion are poorly understood. To investigate these mechanisms, a combination of animal and computational models was utilized. Flow diverters were deployed in four rabbit superior mesenteric artery (SMA) and studied with computational fluid dynamics (CFD) and a previously developed fibrin dynamics model. Subject‐specific vascular models were reconstructed from 3D rotational angiography images and flow conditions were derived from Doppler ultrasound velocity measurements. Flow diverting devices were virtually deployed within the vascular models under guidance from angiography images. Coupled flow and fibrin production, transport, and adhesion simulations were carried out and the effects of fibrin accumulation at the origin of jailed side branches after flow diverter implantation were analyzed. The results of the computational models suggest significant fibrin accumulation across the struts of all flow diverting devices jailing side branches. Larger accumulation was observed at the more distal branches. However, minor flow alterations were produced which were not detectable in angiography sequences. These results were in agreement with experimental observations. On the other hand, fibrin accumulation alone did not explain complete side branch occlusions, which are likely the result of the interaction between initial fibrin accumulation and subsequent cell migration from the peripheral parent artery.
Evaluation of Hemodynamic Environment of Intracranial Aneurysms After Flow Disruption Based on Angiographic Signatures
International Journal for Numerical Methods in Biomedical Engineering | June 1, 2026 | Volume: 42 | Issue: 6 | Pages: No page available
ABSTRACT Incomplete aneurysm occlusion after flow disruption treatment strongly depends on the persistence of strong flow into the aneurysm, which in turn depends on the aneurysm and parent artery geometry as well as the device placement. However, at the time of treatment it remains challenging to predict future outcomes (complete or incomplete occlusion). This paper describes a strategy to evaluate the local hemodynamic environment created immediately after flow‐modifying device deployment to treat cerebral aneurysms and connect it to the subsequent long‐term outcomes. The approach is based on the concept of angiographic signatures that can be extracted from DSA sequences or computational models and represented as images that can be used to compare different aneurysmal environments. The methodology is demonstrated on two small series of four experimental rabbit aneurysms each, treated with either intrasaccular flow disruptors or endoluminal flow diverters. Noticeable differences in the angiographic signatures of completely and incompletely occluded aneurysms at follow‐up were observed. Specifically, larger values of mean transit times and longer time‐to‐peaks were observed deeper into the aneurysms that remained incompletely occluded in both series. The findings suggest that angiographic signatures can be used to assess the underlying hemodynamic environment immediately after device implantation and prognosticate the likelihood of future complete or incomplete occlusion.
Influence of Vessel Geometry, Flow Conditions, and Thrombin Concentration on Fibrin Accumulation and Cerebral Aneurysm Occlusion After Flow Diversion
International Journal for Numerical Methods in Biomedical Engineering | December 26, 2024 | Volume: 41 | Issue: 1 | Pages: No page available
ABSTRACT As the number of cerebral aneurysms treated with flow diverters continues to increase, it is important to understand what factors influence not only thrombus formation within the aneurysm cavity but also fibrin accumulation across the device and its associated disruption and blockage of the inflow stream. Both processes contribute to the eventual occlusion of the aneurysm or its continued patency and incomplete occlusion which may require future re‐treatment. To investigate fibrin accumulation on flow diverters placed across the neck of cerebral aneurysms, a previously developed computational model that couples flow and fibrin dynamics is used in combination with experimental in vitro models of cerebral aneurysms treated with flow diverters. Fibrin accumulation was previously investigated in four glass models of cerebral aneurysms with varying parent artery geometries placed in a flow loop at different flow rates. Corresponding computational models were constructed and compared with the experimental findings. The computational model based on fibrin production stimulated from flow shear stress and subsequent adhesion to device wires was able to reproduce and explain the fibrin accumulation patterns observed in the experimental aneurysms treated with flow diverters. Specifically, these models indicated that increasing vessel curvature, flow rate, and thrombin concentration induced faster fibrin accumulation and associated aneurysm inflow disruption and blockage. The models described and tested in this paper are valuable to understand the detailed mechanisms leading to aneurysm occlusion and healing or incomplete occlusions after treatment with flow diverting devices.
Modeling Fibrin Accumulation on Flow‐Diverting Devices for Intracranial Aneurysms
International Journal for Numerical Methods in Biomedical Engineering | November 6, 2024 | Volume: 40 | Issue: 12 | Pages: No page available
ABSTRACT The mechanisms leading to aneurysm occlusion after treatment with flow‐diverting devices are not fully understood. Flow modification induces thrombus formation within the aneurysm cavity, but fibrin can simultaneously accumulate and cover the device scaffold, leading to further flow modification. However, the interplay and relative importance of these processes are not clearly understood. A computational model of fibrin accumulation and flow modification after flow diversion treatment of cerebral aneurysms has been developed under the guidance of in vitro experiments and observations. The model is based on the loose coupling of flow and transport‐reaction equations that are solved separately by independent codes. Interaction or reactive terms account for thrombin production from prothrombin stimulated by thrombogenic metallic wires and inhibition by antithrombin as well as fibrin production from fibrinogen stimulated by thrombin and flow shear stress, and fibrin adhesion to device wires and already attached fibrin. The computational model was demonstrated and tested on idealized vessel and aneurysm geometries. The model was able to reproduce the salient features of fibrin accumulation after the deployment of flow‐diverting devices in idealized in vitro models of cerebral aneurysms. Namely, fibrin production in regions of high shear stress, initial accumulation at the inflow zone, and progressive occlusion of the device and corresponding flow attenuation. The computational model linking flow dynamics to fibrin production, transport, and adhesion can be used to investigate and better understand the effects that lead to fibrin accumulation and the resulting aneurysm inflow reduction and intra‐aneurysmal flow modulation.