Citations

Showing 10 of 108094 citations.

Maya Blue Paint
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 4 | Issue: 10 | Pages: 3-5

10.1017/s1551929500063240 Get It

Abstract It has been noted by many people who have had the privilege of exploring Mayan ruins that there is a stunning blue color that has been preserved amazing well for centuries. Considering the tropical jungle is quite a hostile environment, the tenacity of this “paint” is remarkable. It had been suggested that this “paint” was made by mixing indigo dye with clay, but this did not explain its special characteristics. Recent work by Miguel José-Yacamán at the National University of Mexico and colleagues has revealed what is special about this material, which is called Maya blue paint. They collected specimens in Mexico at archeologic sites known as Jaina Island and Palenque.
A Blocking Agent for Endogenous Peroxide
Plummer, Timothy B.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 7 | Issue: 4 | Pages: 28-28

10.1017/s1551929500064324 Get It

Virtual Embryology
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 7 | Issue: 4 | Pages: 3-4

10.1017/s1551929500064221 Get It

Abstract Old embryos are now being looked at in a new way. About a hundred years ago, an embryologist by the name of FranMyn Paine Mall devoted his career to collecting human embryos and fetuses (an embryo becomes a fetus after 2 months of gestation) from miscarriages and abortions. These specimens form the core of what is known today as the Carnegie Collection of Human Embryos, housed in the National Museum of Health and Medicine of the Armed Forces Institute of Pathology in Washington, D.C. Whereas this is a priceless national educational resource, how do we extract the information about our embryonic development from these specimens? Classic techniques involve slicing a specimen as thinly as possible on a microtome, then reconstructing the slices in a model large enough to study. The problem is the specimen is effectively destroyed in the process. What is needed is a technique that allows whole embryos to be examined, but not destroyed.
A New Look at Old Beer and Bread
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 4 | Issue: 7 | Pages: 3-5

10.1017/s1551929500060934 Get It

Abstract We know from the pictographic history that the people in ancient Egypt were fond of beer and bread. Fortunately, they sent samples of these food items along with some of their more esteemed citizens to sustain them in the afterlife. Also, samples were available from rubbish heaps of ancient villages, allowing for the comparison of funerary goods with everyday foods. Additional luck was that the dry conditions have kept some samples from deteriorating even after thousands of years. Whereas they did leave us samples, they didn't leave recipes. There have been many theories about how they brewed and baked in ancient Egypt, but proof was lacking. Recently, Delwen Samuel of Cambridge University used optical and scanning electron microscopy (SEM) to determine how the ancient Egyptians brewed beer and baked bread.
Two For The Price Of One
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 3 | Issue: 7 | Pages: 20-20

10.1017/s1551929500062805 Get It

Can Dew Help us to Image Insulating Material?
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 3 | Issue: 1 | Pages: 18-21

10.1017/s1551929500062234 Get It

Abstract In high resolution imaging of biologic structure, atomic lorce microscopy (AFM) has been prevailing over scanning tunneling microscopy (STM). This is primarily because biologic materials do not conduct electricity, and STM requires that electrons flow to or from the surface of the specimen, whereas electron flow is not required for AFM. Microscopists intent on using STM have compensated by coating specimens with a thin coat of metal. However, the presence of metal atoms on the surface degrades the resolution. A new development may make STM more useful to biologists than ever before.
Down the Resolution Road: Freeze-Fracture Revisited?
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 3 | Issue: 1 | Pages: 3-4

10.1017/s1551929500062179 Get It

Abstract It must have seemed rather fantastic back in the fifties, when Russell Steere froze chunks of plant viruses (tobacco mosaic virus, tobacco nngspot virus, and squash mosaic virus) in drops of water, planed them freehand with a scalpel blade, made a replica of the surface, and examined the replica in a transmission electron microscope. But that was the birth of freeze-fracture and freeze-etch methodology that yielded enormous amounts of information about the morphology of membranes.
See Atoms in Motion!
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 4 | Issue: 1 | Pages: 3-4

10.1017/s155192950006692x Get It

Abstract It is impressive enough that individual atoms can be resolved with the atomic force microscope (AFM), but who would have thought that atomic motion would be detected so soon? Atomic resolution with the AFM was only recently achieved. As reported in this column, Franz Giessibl was able to demonstrate local resolution of adatoms of the Si(111) 7×7 reconstructed surface. Now, Yasuhiro Sugawara. Masahiro Ohta, Hitoshi Ueyama, and Seizo Morita of Hiroshima University have demonstrated atomic resolution of the surface of InP(110). Not only that, but images taken about one minute apart show that some of the atoms had moved! Sugawara et al, used a very compact AFM under ultrahigh vacuum (4 X 10-8 Pa) to accomplish this impressive feat. A stiff (spring constant of 34 N/m) silicon cantilever was used. This stiffness, along with a mechanical resonant frequency of 151 kHz, was used to keep the cantilever from jumping onto the sample and crushing the initially sharp tip.
A Microscope that looks Sideways
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 2 | Issue: 9 | Pages: 12-12

10.1017/s1551929500067663 Get It

Abstract When most of us use a microscope, we are looking through a specimen, or more and more frequently, at the “top” surface. It usually doesn't occur to us to look sideways. But that is what was done recently in the laboratory of Charles Lieber at Harvard University. As reported by Daniel Frisbie, Lawrence Rozsnyai, Aleksandr Nay, Mark Wrighton, and Prof, Lieber, an atomic force microscope (AFM) was modified to perform as a “chemical force microscope” (CFM). With the CFM they were able to precisely measure adhesive and frictional forces. These forces can be thought of as acting parallel to the surface of the specimen, whereas most observations are made perpendicular to the surface.
A “Pushy” Microscope
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 4 | Issue: 2 | Pages: 3-4

10.1017/s1551929500067468 Get It

Abstract The process of ultra-miniaturization has been termed nanofabrication. It looks like the scanning tunneling microscope (STU) and related microscopes will be players in this technology of the future. One of the most recent contributions has been the demonstration that single molecules can be “pushed” across a surface with the STM. This remarkable achievement was demonstrated by Thomas Jung, Reto Schlittler, and James Gimzewski of the IBM Zurich Research Laboratory and Hao Tang and Christian Joachim of the National Center for Scientific Research in Toulouse, They were able to position intact individual molecules on a two-dimensional surface at room temperature by a controlled “pushing” action of the tip of a STM. Similar positioning feats have been done at low temperatures while thermal motion is limited.