Citations

Showing 10 of 108094 citations.

Exocytosis at the Atomic Level
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 5 | Issue: 4 | Pages: 3-4

10.1017/s1551929500061332 Get It

Abstract As reviewed in this column on previous occasions, the atomic force microscope (AFM) is steadily making headway as an instrument that can make important contributions to biologic observations. Although the AFM is capable of operating in an aqueous environment, relatively little use has been made of this property to examine cellular structures under conditions that resemble those in vivo. A breakthrough in this regard was recently made by Stefan Schneider, Kumudesh Sritharan, John Geibel, Hans Oberleithner, and Bhanu Jena. of Yale University and the University of Würzburg.
A Tip For Primary Antibody Elutlon:
Plummer, Timothy B.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 6 | Issue: 9 | Pages: 29-29

10.1017/s155192950006956x Get It

Atomic Force Microscopy for Biologists
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 5 | Issue: 3 | Pages: 3-4

10.1017/s1551929500060193 Get It

Abstract Atomic force microscopy (AFM) has proven to be very useful to material scientists and physicists. Biologists are only beginning to utilize the potential of this methodology. In a recent article, Tatsuo Ushiki, Jiro Hitomi, Shigeaki Ogura, Takeshi Umemoto, and Masatsugu Shigeno reviewed the applications of AFM to biologic studies. They began by reviewing the basic principles of AFM, emphasizing the value of the non-contact mode for visualizing the relatively “soft” surface of biologic specimens. They presented some examples of biologic images: DNA, chromosomes, and collagen fibrils. The specimens examined with the AFM did not need to be coated, theoretically offering a view with a smaller potential for artifacts. AFM images have the advantage of containing quantitative information about the sample height.
An Electron Optical Achromat
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 5 | Issue: 6 | Pages: 3-5

10.1017/s1551929500056029 Get It

Abstract Spherical and chromatic aberrations have been the bane of optical lenses ever since they were first ground from a piece of glass. As light travels through a convex (converging) lens, the rays at the center of the optical axis are refracted (bent) less than the peripheral rays, so that the central rays are focused behind the peripheral rays. This is the essence of spherical aberration. Light of differing wavelengths (colors) interact differently with the lens so that longer wavelengths (red) are focused behind shorter wavelengths (blue). This is chromatic aberration. In the early days of light microscopy, these two inherent flaws seriously limited the quality of images.
Getting The Most Out Of Light
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 3 | Issue: 6 | Pages: 32-33

10.1017/s1551929500062647 Get It

Dissecting Chromosomes, One at a Time!
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 6 | Issue: 2 | Pages: 3-4

10.1017/s1551929500059526 Get It

Abstract The atomic force microscope (AFM) is proving to be as much a tool as an imaging device. Recently, Stefan Thalhammer, Robert Stark, Stefan Müller, Johannes Wienberg and Wolfgang M. Heckl have added another useful technique to this repertoire. They demonstrated that the AFM can be used to cut out an identified section of DNA and then extract that section for amplification. They began by flow sorting chromosomes, and then increased the specific amount of the target DNA with a “pre-set” in situ hybridization with chromosome-specific DMA to provide a specimen rich in chromosome 2. To identify the target area, selected chromosomes were examined with the AFM in the non-contact mode using stiff cantilevers.
Trapping Subfemtoliter-Sized Vesicles, and Analyzing Them
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 6 | Issue: 4 | Pages: 3-4

10.1017/s1551929500067158 Get It

Abstract The chemical analysis of secretory vesicles has long been limited by the fact that many vesicles are analyzed together, resulting in an averaging of a population. Differences between vesicles within that population could not be detected. Wouldn't it be great if vesicles could be analyzed one at a time? You guessed it, this breakthrough has been recently achieved. The technique of capillary electrophoresis (CE) was modified by Daniel Chiu, Sheri Lillard, Richard Scheller, Richard Zare, Sandra Rodriguez-Cruz, Evan Williams, Owe Orwar, Mats Sandberg, and Anders Lundqvist so that vesicles could be probed singly.
Watching Rafts Move Within Cells: A Fluorescence Microscope-Based Transport Assay
Carmichael, Stephen W., Salisbury, Jeffery L.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 1 | Pages: 3-7

10.1017/s1551929500057059 Get It

Abstract Imagine a raft in a canal between point A and point B. On that raft is a visible (fluorescent) cargo. Also, attached to that raft is a motor that will propel the raft only from A to B (anterograde transport). When the raft gets to point B, another motor is attached that can propel the raft, and its cargo, and the anterograde motor, back to point A (retrograde transport). Within a cell, the canals are microtubLiles, and a lot is known about anterograde and retrograde transport in some systems, but these phenomena have not been directly observed in a living, intact animal. Until now, that is. In a pair of very interesting papers, the laboratory of Jonathan Scholey has shown us convincing micrographs of anterograde and retrograde transport in an important animal model.
How to Slam a Cell
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 7 | Issue: 3 | Pages: 3-4

10.1017/s1551929500064026 Get It

Abstract Many important discoveries in cell biology have been made by introducing specific compounds into a certain cell and observing the effect. Several methods have been used for the introduction of the compounds. For example, permeabilizing the cell by electroporation (an electric shock that has been demonstrated to poke holes in the plasma membrane), the use of biologic molecules (such as streptolysin 0) to create channels in the plasma membrane, or detergents to dissolve hoies in the plasma membrane. Several laboratories have shown these methods to be effective, but one questions the physiologic state of a holey cell. Liposomes or similar vehicles can be packed with compounds and fused with the cells of interest, but this method of introduction has drawbacks as well.
Laser Capture Microdissection: A Punch Biopsy Under the Microscope
Carmichael, Stephen W.

Mayo Clinic

Microscopy Today | March 14, 2018 | Volume: 6 | Issue: 1 | Pages: 3-4

10.1017/s1551929500059009 Get It

Abstract The size and precision af a tissue sample has always been a concern. As it has become possible to analyze smaller and smaller samples with molecular techniques, one must be increasingly concerned that the sample is what we think it is. So how do you dissect out a specific cell or a small group of cells? Whereas several techniques have been suggested, a group at the National Institutes of Health (NIH) have come up with an ingenious solution. Robert Bonner, Michael Emmert-Buck, Kristina Cole, Thomas Pohida, Rodrigo Chuaqui, Seth Goldstein, and Lance Liotta have published a technique they have termed Laser Capture Microdissection (LCM). With LCM, Bonner et. al. have demonstrated that a specific cell can be identified and transferred to an appropriate container for molecular analysis. Using the polymerase chain reaction (PCR), the genetic material from a single cell can be amplified for analysis. However, data from several cells (about 20) needs to be examined so that variations in the cell cycle, etc., can be averaged.