Citations

Clear

798 citation(s) found for "Levy, E".

Effect of ramipril on walking times and quality of life among patients with peripheral artery disease and intermittent claudication: A randomized controlled trial. Journal of the American Medical Association 2013; 309: 453–460
Kurklinsky, Andrew K., Levy, Michael

Mayo Clinic

Vascular Medicine | July 19, 2013 | Volume: 18 | Issue: 4 | Pages: 234-236

10.1177/1358863x13497529 | PMID 23867841 Get It

Study objective: The objective of the trial was to examine whether ramipril, an angiotensin-converting enzyme (ACE), improves walking distance and health-related quality of life in patients with peripheral artery disease (PAD) associated with claudication. Study population: The study enrolled 212 patients with risk factors and symptoms of PAD treated by conventional therapies at three centers in Australia. All patients had an ankle–brachial index (ABI) of less than 0.90 at rest and intermittent claudication in at least one leg, which were stable for at least 6 preceding months along with the medication regimen. The patients were excluded if blood pressure was not controlled (brachial blood pressure of 160/100 mmHg or greater); if there was current or recent use of either ACE inhibitors or angiotensin II receptor blockers, potassium-sparing diuretics, or potassium supplements; renal failure (serum creatinine level 2.3 mg/dL or greater [200 µmol/L]); renal artery stenosis; previous coronary or peripheral artery revascularizations, recent myocardial infarction and other health conditions other than PAD that could adversely influence walking ability at the time of screening and for 1 year thereafter. Design and methods: This was a randomized, placebo-controlled, triple blinded study of ramipril at the high daily dose (10 mg) for 6 months. Primary outcomes were pain-free and maximum walking times assessed by a standard treadmill exercise test. Secondary outcomes were ABI changes; symptoms and functional status assessed by the Walking Impairment Questionnaire (WIQ) 1 ; health-related quality of life assessed by the Short-Form 36 Health Survey (SF-36) 2 ; and stenosis severity assessed by duplex ultrasound of the lower limb arteries. At baseline and at follow-up, pain-free and maximum walking distances were assessed by the standard constant load treadmill exercise test performed at a speed of 3.2 km/h and a grade of 12%. 3 ABI was calculated in both legs. Duplex ultrasonography was used to determine stenosis in lower-limb vessel segments. Functional changes per WIQ, and perceived disability assessed on the Physical Component Summary and the Mental Component Summary of the SF-36 were self-reported. Sample size was calculated as 100 patients per each group needed to provide a power of 80% at an α of 0.05 to detect a 120-second change in walking time and a 65-second change in pain-free walking time. A two-sided p-value of less than 0.05 was considered significant. Baseline variables were compared using the χ 2 test and one-way analysis of variance. The analysis of covariance model with baseline and post-treatment values after 6 months used Kruskal–Wallis analysis of variance. Imputations for missing 6-month data were performed. Data were analyzed on the intention-to-treat basis. Results: Of 921 potential participants screened, 212 eligible participants were randomized into equal-sized ramipril and placebo groups where baseline parameters were not different. Compliance was monitored by pill count and adverse effects were monitored through interval clinical assessments, laboratory tests, and telephone calls. There was a 100% adherence rate to the study medications among 200 patients who completed the study. Ramipril was associated with a 75-second increase in mean pain-free and a 255-second increase in maximum walking time. There was a modest (less than 5 mmHg) blood pressure reduction and a small (0.1) ABI increase at rest and after exercise compared to placebo. The maximum walking time increase after ramipril therapy compared to placebo was greater in the subgroup of patients with femoropopliteal disease (286 seconds) than in those with aortoiliac disease (127 seconds). Patients treated with ramipril showed improvement of the median distance, speed and stair climbing scores on the WIQ, as well as of the Physical, but not the Mental, Component Summary score on the SF-36. The most frequent side effect was dizziness, more common in the ramipril (8.5%) than in the placebo (2.8%) group. Persistent cough occurred in 6.6% of patients on ramipril, causing their withdrawal from the study.
CT and MRI Measurements of Tibial Tubercle–Trochlear Groove Distances Are Not Equivalent in Patients With Patellar Instability
Camp, Christopher L. , Krych, Aaron J. , Levy, Bruce A. , Bond, Jeffrey R., Collins, Mark S., Dahm, Diane L., Camp, Christopher L. , Stuart, Michael J. , Krych, Aaron J

Mayo Clinic

The American Journal of Sports Medicine | July 15, 2013 | Volume: 41 | Issue: 8 | Pages: 1835-1840

10.1177/0363546513484895 | PMID 23857884 Get It

Background: Tibial tubercle–trochlear groove distance (TT-TG) is a commonly used measurement for surgical decision making in patients with patellofemoral malalignment and instability. This measurement has historically been performed utilizing axial computed tomography (CT). More recently, magnetic resonance imaging (MRI) has been proposed as an equivalent method, but this has not yet been fully validated. Purpose: To determine the reliability of TT-TG distance measurements on both MRI and CT and to determine whether the measurements are interchangeable with one another. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: All patients with patellar instability who underwent both CT and MRI of the knee from 2003 to 2011 were included (n = 59 knees in 54 patients). Two fellowship-trained musculoskeletal radiologists measured the TT-TG distances for each patient by CT and MRI in a randomized, blinded fashion. Interobserver reliability was calculated between radiologists for both imaging modalities, and intermethod reliability was calculated between the 2 imaging modalities. The results are reported using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Results: The 59 knees had a mean TT-TG distance of 16.9 mm (range, 8.3-25.8 mm) by CT and 14.7 mm (range, 1.5-25.1 mm) by MRI. Interobserver reliability between the radiologists was considered excellent for both CT and MRI (ICC = 0.777 and 0.843, respectively). When comparing CT to MRI, the ICC was considered only fair for each of the raters (0.532 and 0.539). Eleven patients (19%) had a TT-TG distance of ≥20 mm on CT preoperatively and underwent distal realignment by tibial tubercle osteotomy. In this surgical subgroup, the mean TT-TG distance was 22.5 mm (range, 19.8-25.8 mm) by CT and only 18.7 mm (range, 14.4-22.8 mm) by MRI for a mean difference of 3.80 mm ( P < .001). Conclusion: The TT-TG distance can be measured with excellent interrater reliability on both MRI and CT; however, the values derived from these 2 tests may not be interchangeable. This observation should be taken into consideration when MRI is used for surgical planning because MRI may underestimate the TT-TG distance when compared with CT.
O-009 Safety of flow diversion: Results from a multicentre registry
Kallmes, D, Boccardi, Edoardo , Çekirge, Saruhan , Lylyk, P, McDougall, Cameron M. , Woo, Henry H. , Bonafé, Alain , Fiorella, David , Hanel, Ricardó A. , Jabbour, Pascal , Levy, Elad I. , Lopes, Demetrius K. , Siddiqui, Adnan H. , Szikora, István

Mayo Clinic

Journal of NeuroInterventional Surgery | July 15, 2013 | Volume: 5 | Issue: Suppl 2 | Pages: A6.1-A6

10.1136/neurintsurg-2013-010870.9 Get It

Purpose To determine the rates of neurologic adverse events following Pipeline Embolic Device (PED) placement for intracranial aneurysm treatment. Methods A retrospective review of medical records was performed at 19 centres to identify consecutive intracranial aneurysms treated with the PED following regulatory approval for marketing the device in the given country. All patients in whom at least one PED was placed and in whom follow-up was available prior to IRB or ethics panel approval were enrolled. Three anatomic/size subgroups were defined, including 1) pre-PComm, internal carotid artery aneurysms 10mm or greater (“large ICA”), 2) ICA aneurysms >10mm and/or at/distal to the PComm region (“other anterior circulation”), and 3) posterior circulation aneurysms. “Primary safety events” included stroke, haemorrhage, parent artery stenosis, permanent cranial neuropathy, and spontaneous rupture of the target aneurysm. Severe safety events were defined as any event causing significant impairment of functioning causing the inability of the subject to carry out usual activities. Statistical analysis was performed using standard summary statistics; p-values comparing subgroups were computed using Pearson's chi-square test for discrete variables and analysis of variance for continuous variables. Results To date, 580 aneurysms, including 183 large ICA, 344 other anterior circulation, and 53 posterior circulation aneurysms have been treated and followed for a mean duration of 7.8 months (SD 7.3, range 0.1 - 40.8). 437 (76%) of 580 aneurysms were saccular and 80 (14%) were fusiform; 32 (5.5%) were classified as giant (<25mm diameter). 549 (93%) were unruptured. 241 (42%) were treated with multiple PEDs. Primary safety events were noted in 62 (12%) cases. Severe neurological events occurred in 35 (6.8%) cases, and occurred more frequently in posterior circulation aneurysms (7 (13%)) than in either large ICA or other anterior circulation aneurysms (15 (8.8%) and (13 (4.5%), respectively, p=.035). Major stroke occurred in 20 (3.9%) of 515 subjects (4.1%, 3.1%, and 7.5% in large ICA, other anterior circulation, and posterior circulation aneurysms, respectively, p=.31). Ipsilateral intracranial haemorrhage occurred in 12 (2.3%) subjects (3.5%, 1.7%, and 1.9% in large ICA, other anterior circulation, and posterior circulation aneurysms, respectively, p=.47). Spontaneous aneurysm rupture occurred in 3 (0.6%) aneurysms, all of which were giant, resulting in a 9% incidence of rupture in giant aneurysms. Mortality rate was 4.3% and was significantly higher for posterior circulation aneurysms (11.3%) as compared to anterior circulation aneurysms (3.5%, p=.019). Conclusions Preliminary data indicates that in approximately 7% of aneurysms treated with PED, substantial neurologic complications occurred, with rates of both severe neurologic events and mortality occurring significantly higher in the posterior as compared to the anterior circulation. Both ipsilateral haemorrhage and spontaneous aneurysm rupture were rare, with the latter event limited to giant aneurysms. Disclosures D. Kallmes: 1; C; MicroVention, Sequent, Benvenue, eV3. 2; C; General Electric, Codman, eV3. E. Boccardi: None. A. Bonafe: None. S. Cekirge: None. D. Fiorella: 2; C; Pipeline proctor, consultant, (<10K, EV3). R. Hanel: None. P. Jabbour: None. E. Levy: None. D. Lopes: 6; C; Receives compensation for training & proctoring for Pipeline devices. P. Lylyk: None. C. McDougall: None. A. Siddiqui: None. I. Szikora: None. H. Woo: None.
Cardiac Troponin Elevation Predicts Mortality in Patients Undergoing Orthotopic Liver Transplantation
Snipelisky, David , Donovan, Sean, Levy, Michael , Satyanarayana, Raj, Shapiro, Brian P.

Mayo Clinic

Journal of Transplantation | July 14, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-6

10.1155/2013/252838 | PMID 23956840 Get It

Introduction. While patients undergoing orthotopic liver transplantation (OLT) have high cardiovascular event rates, preoperative risk stratification may not necessarily predict those susceptible patients. Troponin T (TnT) may help predict patients at risk for cardiovascular complications.Methods. Consecutive patients undergoing OLT at Mayo Clinic in Florida between 1998 and 2010 who had TnT obtained within 10 days following surgery were included. Three groups were compared based on TnT level: (1) normal (TnT≤0.01 ng/mL), (2) intermediate (TnT 0.02–0.11 ng/mL), and (3) elevated (TnT>0.11 ng/mL). Overall and cardiovascular mortality was assessed.Results. Of the 78 patients included, there was no difference in age, gender, severity of liver disease, and echocardiographic findings. Patients in the normal and intermediate TnT groups had a lower overall mortality rate (14.3% and 0%, resp.) when compared with those with elevated TnT (50%;P=0.001). Patients in the elevated TnT group had a cardiovascular mortality rate of 37.5% compared with 1.4% in the other groups combined (P<0.01). The elevated TnT group had a much higher mortality rate when compared with those in the intermediate group (P<0.0001).Conclusion. TnT may accurately help risk stratify patients in the early postoperative setting to better predict cardiovascular complications.
Retrorectal cystic hamartoma: this cyst has a “tail” to tell
Gleeson, Ferga C. , Lévy, Michaël

Mayo Clinic

Endoscopy | July 5, 2013 | Volume: 45 | Issue: S 02 | Pages: E191-E192

10.1055/s-0033-1344130 | PMID 23832502 Get It

Radiation Exposure in the Cardiac Catheterization Lab
Levy, Michael S. , Kumar, Preetham

Mayo Clinic

Catheterization and Cardiovascular Interventions | June 21, 2013 | Volume: 82 | Issue: 1 | Pages: 17-18

10.1002/ccd.25027 | PMID 23788383 Get It

Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses
Vázquez-Sequeiros, Enrique , Levy, Michael J. , Domselaar, Manuel Van , González-Panizo, Fernando, Foruny, José Ramón , Boixeda-Miquel, Daniel, Juzgado-Lucas, Diego, Lucas, Diego Juzgado, Albillos, Agustı́n

Mayo Clinic

Diagnostic and Therapeutic Endoscopy | May 30, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-6

10.1155/2013/150492 | PMID 23818747 Get It

Background and Aims . EUS-FNA is an accurate and safe technique to biopsy mediastinal lymph nodes. However, there are few data pertaining to the role of EUS-FNA to biopsy central lung masses. The aim of the study was to assess the diagnostic yield and safety of EUS-FNA of indeterminate central mediastinal lung masses. Methods . Design: Retrospective review of a prospectively maintained database; noncomparative. Setting: Tertiary referral center. From 10/2004 to 12/2010, all patients with a lung mass located within proximity to the esophagus were referred for EUS-FNA. Main Outcome Measurement: EUS-FNA diagnostic accuracy and safety. Results . 73 consecutive patients were included. EUS allowed detection in 62 (85%) patients with lack of visualization prohibiting FNA in 11 patients. Among sampled lesions, one patient (1/62 = 1.6%) had a benign lung mass (hamartoma), while the remaining 61 patients (61/62 = 98.4%) had a malignant mass (primary lung cancer: 55/61 = 90%; lung metastasis: 6/61 = 10%). The sensitivity, specificity, and accuracy of EUS-FNA were 96.7%, 100%, and 96.7%, respectively. The sensitivity was 80.8% when considering nonvisualized masses. One patient developed a pneumothorax (1/62 = 1.6%). Conclusions . EUS-FNA appears to be an accurate and safe technique for tissue diagnosis of central mediastinal lung masses.
Hepatic artery pseudoaneursym formation following intraductal biliary radiofrequency ablation
Topazian, Mark , Levy, Michael J. , Patel, Smita , Baron, Todd H. , Levy, Michael J. , Charlton, Michael

Mayo Clinic

Endoscopy | May 28, 2013 | Volume: 45 | Issue: S 02 | Pages: E161-E162

10.1055/s-0032-1326644 | PMID 23716112 Get It

Simple Risk Model Predicts Incidence of Atrial Fibrillation in a Racially and Geographically Diverse Population: the CHARGE‐AF Consortium
Alonso, Álvaro , Krijthe, Bouwe P., Aspelund, Thor , Stepas, Katherine A., Pencina, Michael , Moser, Carlee , Sinner, Moritz F. , Sotoodehnia, Nona, Fontes, João D. , Janssens, A. Cecile J.W. , Witteman, Jacqueline C.M., Chamberlain, Alanna M. , Lubitz, Steven A. , Agarwal, Sunil , McManus, David D. , Ellinor, Patrick T. , Larson, Martin G. , Burke, Gregory L. , Hofman, Albert , Levy, Daniel , Gottdiener, John S. , Couper, David , Harris, Tamara B. , Soliman, Elsayed Z. , Stricker, Bruno H. , Guðnason, Vilmundur , Heckbert, Susan R. , Benjamin, Emelia J. , Kronmal, Richard A. , Magnani, Jared W. , Schnabel, Renate B. , Launer, Lenore J. , Kääb, Stefan , Alonso, Alvaro , Chamberlain, Alanna M , Benjamin, Emelia J , Lubitz, Steven A , Ellinor, Patrick T , Levy, Daniel , Couper, David

Mayo Clinic

Journal of the American Heart Association | May 24, 2013 | Volume: 2 | Issue: 2 | Pages: No page available

10.1161/jaha.112.000102 | PMID 23537808 Get It

Background Tools for the prediction of atrial fibrillation ( AF ) may identify high‐risk individuals more likely to benefit from preventive interventions and serve as a benchmark to test novel putative risk factors. Methods and Results Individual‐level data from 3 large cohorts in the U nited S tates (Atherosclerosis Risk in Communities [ ARIC ] study, the Cardiovascular Health Study [ CHS ], and the Framingham Heart Study [ FHS ]), including 18 556 men and women aged 46 to 94 years (19% A frican A mericans, 81% whites) were pooled to derive predictive models for AF using clinical variables. Validation of the derived models was performed in 7672 participants from the Age, Gene and Environment—Reykjavik study ( AGES ) and the Rotterdam Study ( RS ). The analysis included 1186 incident AF cases in the derivation cohorts and 585 in the validation cohorts. A simple 5‐year predictive model including the variables age, race, height, weight, systolic and diastolic blood pressure, current smoking, use of antihypertensive medication, diabetes, and history of myocardial infarction and heart failure had good discrimination (C‐statistic, 0.765; 95% CI , 0.748 to 0.781). Addition of variables from the electrocardiogram did not improve the overall model discrimination (C‐statistic, 0.767; 95% CI , 0.750 to 0.783; categorical net reclassification improvement, −0.0032; 95% CI , −0.0178 to 0.0113). In the validation cohorts, discrimination was acceptable ( AGES C‐statistic, 0.664; 95% CI , 0.632 to 0.697 and RS C‐statistic, 0.705; 95% CI , 0.664 to 0.747) and calibration was adequate. Conclusion A risk model including variables readily available in primary care settings adequately predicted AF in diverse populations from the U nited S tates and E urope.
Drug‐eluting stents and diabetes
Parikh, Pragnesh , Levy, Michael S.

Mayo Clinic

Catheterization and Cardiovascular Interventions | May 24, 2013 | Volume: 81 | Issue: 7 | Pages: 1115-1116

10.1002/ccd.24962 | PMID 23704064 Get It