Citations

Clear

168 citation(s) found for "Cha, Yong‐Mei".

Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery
Khalil, Fouad , Madhavan, Malini , Ahmad, Ali , Mulpuru, Siva K. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Siontis, Konstantinos C , Deshmukh, Abhishek J , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi , Badawy, Mohamed, Kapa, Suraj , DeSimone, Christopher V.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 | PMID 34911151 Get It

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
A Real-world Experience of Atrioventricular Synchronous Pacing with Leadless Ventricular Pacemakers
Kowlgi, Gurukripa N. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon-Chi , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Kowlgi, Narayan G , Tseng, Andrew S. , Asirvatham, Samuel J.

Mayo Clinic

No container title available | November 16, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163711930.05423871/v1 Get It

Aims: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are currently lacking. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous-ventricular pacing (AsVP) ≥70%. Results: Fifty-six percent of patients achieved AsVP ≥70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure and pulmonary hypertension. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were persistent atrial arrhythmias, small A4-wave amplitude, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. Conclusion: With the increasing popularity of leadless PM, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm
Amin, Mustapha, Hilaire, Emilie, Siontis, Konstantinos C. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Farwati, Medhat , Siontis, Konstantinos C , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Deshmukh, Abhishek J , Cha, Yong-Mei , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Kapa, Suraj

Mayo Clinic

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 | PMID 34664765 Get It

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.
Comparison of synchronization between left bundle branch and his bundle pacing in atrial fibrillation patients: An intra‐patient‐controlled study
Sheng, Xia , Pan, Yiwen , Yu, Chan, Wang, Bei , Zhang, Pei , Li, Jing , Zhang, Jiefang , Chen, Shiquan , Wang, Min , Sun, Yaxun , Jiang, Dongmei , Yang, Ying , Ye, Yang , Cha, Yong‐Mei , Pan, Yi-Wen , Zhang, Jie-Fang , Sun, Ya-Xun , Fu, Guo-Sheng

Mayo Clinic

Pacing and Clinical Electrophysiology | August 2, 2021 | Volume: 44 | Issue: 9 | Pages: 1523-1531

10.1111/pace.14331 | PMID 34337768 Get It

AbstractBackgroundHis bundle pacing (HBP) is a physiological pacing strategy to preserve the electrical synchrony of ventricular conduction and left ventricular (LV) function. Left bundle branch pacing (LBBP) has emerged as an alternative physiological pacing technique.ObjectiveTo evaluate cardiac electrical and mechanical synchrony comparing LBBP and HBP in patients with permanent atrial fibrillation (AF).MethodsConsecutive patients with symptomatic bradycardia and AF were enrolled from January to June of 2019. The cardiac electrical and mechanical synchrony in different pacing mode were evaluated at baseline and after implantation.ResultsBoth HBP and LBBP were performed in 20 patients. LBBP significantly widened the QRS duration compared with the intrinsic conduction (113.2 ± 14.5 vs. 96.5 ± 16.2 ms; p = .01), while HBP did not (104.5 ± 22.3 vs. 96.5 ± 16.2 ms; p = .12). Both LBBP and HBP patients had similar LV myocardial strain measurements for the mechanical synchrony evaluation without significant change compared with baseline. There was no significant difference in right ventricular synchrony measurement between LBBP and HBP. Compared to HBP, LBBP had less interventricular synchrony (IMVD, 14.7 ± 9.2 vs. 3.1 ± 12.7 ms, p < .01; Ts‐LV‐RV, 37.9 ± 10.7 vs. 18.5 ± 10.8 ms, p < .001).ConclusionsAlthough LBBP's a physiological pacing mode can achieve a similar cardiac electrical and mechanical synchronization when compared to HBP, LBBP results in modest delay in RV activation, and the clinical implication remains to be studied.
Portable Device Improves the Detection of Atrial Fibrillation After Ablation
Huang, Songqun , Liu, Chao , Qin, Aihong, Dong, Shaohua, Xing, Wenhui , Guo, Zhifu , Huang, Xinmiao, Cha, Yong‐Mei , Cao, Jiang, Cha, Yongmei, Zhao, Teng , Yuan, Binhang

Mayo Clinic

International Heart Journal | July 16, 2021 | Volume: 62 | Issue: 4 | Pages: 786-791

10.1536/ihj.21-067 | PMID 34276021 Get It

Using ensemble of ensemble machine learning methods to predict outcomes of cardiac resynchronization
Cai, Cheng , Zhang, Pei , Xiao, Peilin , Dai, Mingyan , Noseworthy, Peter A. , Friedman, Paul A. , Cha, Yong‐Mei , Zhang, Pei , Noseworthy, Peter A , Chen, Ming-Long , Cha, Yong-Mei , Cai, Cheng, Tafti, Ahmad P , Ngufor, Che , Liu, Hongfang

Mayo Clinic

Journal of Cardiovascular Electrophysiology | July 14, 2021 | Volume: 32 | Issue: 9 | Pages: 2504-2514

10.1111/jce.15171 | PMID 34260141 Get It

AbstractIntroductionThe efficacy of cardiac resynchronization therapy (CRT) has been widely studied in the medical literature; however, about 30% of candidates fail to respond to this treatment strategy. Smart computational approaches based on clinical data can help expose hidden patterns useful for identifying CRT responders.MethodsWe retrospectively analyzed the electronic health records of 1664 patients who underwent CRT procedures from January 1, 2002 to December 31, 2017. An ensemble of ensemble (EoE) machine learning (ML) system composed of a supervised and an unsupervised ML layers was developed to generate a prediction model for CRT response.ResultsWe compared the performance of EoE against traditional ML methods and the state‐of‐the‐art convolutional neural network (CNN) model trained on raw electrocardiographic (ECG) waveforms. We observed that the models exhibited improvement in performance as more features were incrementally used for training. Using the most comprehensive set of predictors, the performance of the EoE model in terms of the area under the receiver operating characteristic curve and F1‐score were 0.76 and 0.73, respectively. Direct application of the CNN model on the raw ECG waveforms did not generate promising results.ConclusionThe proposed CRT risk calculator effectively discriminates which heart failure (HF) patient is likely to respond to CRT significantly better than using clinical guidelines and traditional ML methods, thus suggesting that the tool can enhanced care management of HF patients by helping to identify high‐risk patients.
Activation Pattern During His-Bundle Pacing
Yasin, Omar , Bush, Jaime, Vaidya, Vaibhav R. , Tri, Jason , Zyl, Martin van , Xiao, Peilin , Scheuermann, Cory, Asirvatham, Samuel J. , Cha, Yong‐Mei , Asirvatham, Samuel J , Xiao, Peilin , Han, Jie

Mayo Clinic

No container title available | July 11, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162602806.64990926/v1 Get It

Abstract 14833: National Trends in Complications and 30-day Re-hospitalization After Lead Removal/extraction: Analysis From a Cohort Of 42,878 Patients
Mulpuru, Siva K. , Sangaralingham, Lindsey R. , Mawangi, Raphael, Deshmukh, Abhishek , Shah, Nilay D. , Killu, Ammar M. , Cha, Yong‐Mei , Friedman, Paul A. , Noseworthy, Peter A. , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14833 Get It

Introduction: As the US population ages and indications for cardiac device implantation expand, there is a concomitant increase in patients undergoing lead removal/extraction (LR/E).. We sought to examine trends in outcomes and complications associated with LR/E. Methods: We conducted a retrospective analysis using data from a large U.S. commercial insurance database (privately insured and Medicare Advantage patients) identifying all patients undergoing LR/E between 2004 and 2013 with at least one year continuous medical plan enrollment prior to LR/E (to identify baseline comorbidities). Using ICD9 codes and CPT codes, major complications (hemorrhage requiring transfusion, vascular injury, pericardial complications, respiratory complications, cerebrovascular complications, and requirement for cardiac surgery) associated with LR/E and 30-day readmission rates were evaluated. Results: Among 42,878 patients who underwent LR/E (median age of 62 ( 54, 72) years, 70% male); approximately 1 in 40 experienced a major adverse event (2.4%) during the study period. Respiratory complications were the most common complication and 311 patients required cardiac surgery. 30-day readmission occurred in 11.1% of the total population. The most common reasons for readmission were heart failure exacerbation (18.7%) and device related complications (13.2%). Conclusion: The observed complication rates after LE/R in clinical practice are similar to those seen in recent clinical trials and have been relatively stable over the past 10 years.
Abstract 10903: Extraction Outcomes in Patients With Congenital Heart Disease
Fender, Erin A. , Killu, Ammar M. , Hodge, David O. , Cannon, Bryan C. , Friedman, Paul A. , Broberg, Craig S. , Cha, Yong‐Mei , McLeod, Christopher J. , Henrikson, Charles A.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.10903 Get It

Introduction: Patients with congenital heart disease (CHD) frequently require implantable cardiac devices. Device infection or malfunction may necessitate lead extraction. Extraction may be challenging due to long lead dwell times, anatomic abnormalities, and prior cardiac surgery. Little is known about extraction outcomes in the CHD population. Methods and Results: This retrospective study included 41 CHD patients and 82 age and gender matched controls that underwent lead extractions at two centers between 2001-2014. Only patients with leads older than 12 months were included. There were 79 leads in CHD patients and 150 in controls. Patients with CHD had a mean age of 39±17 years at extraction and on average their leads had been implanted for 81±84 months, this was not significantly different from the control group. Eighty eight percent of CHD patients had 1 or more cardiac surgeries as compared to only 22% of controls (p<0.001). The number of abandoned leads was also significantly different with 16 abandoned leads in the CHD group and 3 in controls (p<0.001). There was no statistically significant difference in extraction techniques between the groups. Complete extraction was achieved in 94% of patients in both groups. There were no CHD group complications. Control group complications included 3 SVC lacerations requiring sternotomy (one was fatal), and 1 ventricular perforations with tamponade requiring sternotomy. None of these patients had a history of cardiac surgery. The average age of leads in patients with a complication was 15.3 years which was older than the mean lead age seen in the CHD and control populations which was 6.75 and 4.6 years respectively. Conclusions: Lead extraction can be safely performed in patients with CHD. Despite anatomic abnormalities and previous cardiac surgery, the outcome of lead extraction in patients with CHD is comparable to controls. Prior cardiac surgery may lower the risk for extraction complications.
Abstract 2750: Multi-detector Computed Tomography Is An Accurate Screening Imaging Modality For Detection Of Thrombus In Patients Undergoing Catheter Ablation Of Atrial Fibrillation
Martinez, Matthew W. , Kirsch, Jacobo , Williamson, Eric E. , Cha, Yong‐Mei , Friedman, Paul A. , Ommen, Steve R. , Callahan, Mark J., Syed, Imran S., Feng, DaLi, Beinborn, Douglas S., Packer, Douglas L. , Brady, Peter A. , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_610-b Get It

Introduction Multi-detector computed tomography (MDCT) is commonly used to identify pulmonary vein and left atrial anatomy prior to catheter ablation for atrial fibrillation (CAAF). Additionally, transesophageal echocardiography (TEE) is utilized to exclude left atrial/left atrial appendage thrombus (ICT). Whether MDCT alone can be used to exclude thrombus obviating the need for TEE is unknown. Methods All Pts referred for CAAF at Mayo Clinic between March 2004 and October 2006 were included. Clinical data (including CHADS score), 64 slice MDCT (non-ECG gated), TEE and intra-cardiac echocardiograph (ICE) were all performed and recorded. Image data was reviewed independently and blinded. The left atrial appendage (LAA) was defined as fully opacified or underfilled. An underfilled LAA was further interrogated using a region of interest over the filling defect and mean attenuation in Hounsfield Units (HU) were recorded. Results In total 400 Pts (mean age 56 ± 10 yrs; 76% male; EF 56 ± 10 % ) were included. 362 had no ICT by TEE nor filling defect by MDCT. 38 patients had an underfilled LAA in whom ICT was confirmed by TEE in 7. Sensitivity and specificity of MDCT for ICT was 100% and 92% respectively with a NPV of 100%. In 19 Pts with underfilled LAA’s, a mean LAA emptying velocity was found to be significantly reduced at 26 cm/s (6 – 61 cm/s). Those with a thrombus had a mean attenuation value below 70 HU. CHADS2 score was higher (2.0 versus 1.0) in Pts with LAA filling defect versus those without LAA filling defect. All Pts with confirmed thrombus were taking Warfarin. ICT was not seen in any Pts aged <52 yrs with CHADS score ≤1. Conclusions Sensitivity and specificity of MDCT for detection of LAA thrombus is high. LAA filling defects on MDCT correlate with low emptying velocities by TEE and low attenuation value in HU. These data would suggest that in the absence of MDCT filling defect, no further imaging is required. TEE should be utilized prior to CAAF to investigate MDCT filling defects. Multidetector Computed Tomography for the Detection of LAA Thrombus