Citations

Showing 10 of 108162 citations.

Filter Paper Lead Testing
Moyer, Thomas P. , Nixon, David N, Ash, K O

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 12 | Pages: 2055-2056

10.1093/clinchem/45.12.2055 Get It

Immunoradiometric Assay for Intact Human Osteocalcin(1–49) without Cross-Reactivity to Breakdown Products
Colford, John W, Lueddecke, Bruce A, Salvati, Michael, Hanna, D. Alan., Sailer, Dawn E., Riggs, B. Lawrence, Langman, Craig B. , Lueddecke, Bruce A., Khosla, Sundeep

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 4 | Pages: 526-531

10.1093/clinchem/45.4.526 Get It

AbstractBackground: Osteocalcin (Oc), a serum marker of bone turnover, circulates in several forms. We developed an assay for intact human Oc and investigated its clinical features.Methods: We generated goat antibodies and N- and C-terminal Oc. The former was used on solid phase (polystyrene beads), and the latter was used as the tracer in an IRMA.Results: The assay was linear with no cross-reactivity to Oc(1–43), total imprecision (CV) of <10%, and recovery of 100% ± 10%. Assay values for intact Oc in EDTA plasma samples were unchanged at 18–25 °C for 6 h. Values for intact Oc in serum, EDTA plasma, and heparin plasma samples did not change after storage on ice for 8 h. Serum samples from patients with various conditions were stored at −70 or −135 °C for up to 5 years and yielded z-scores comparable to an Oc(1-43) IRMA for all conditions except for renal failure. In renal failure, the Oc(1–43) assay values were increased, whereas the intact assay values were in the reference interval.Conclusion: Decreases in Oc assay values are inhibited by calcium chelation, and slowed by reduced temperatures. The described assay for intact Oc allows improved specificity for bone compared with an assay for Oc(1–43).
Maximizing Efficacy of Endocrine Tests: Importance of Decision-focused Testing Strategies and Appropriate Patient Preparation
Klee, George G.

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 8 | Pages: 1323-1330

10.1093/clinchem/45.8.1323 Get It

AbstractThe efficacy of endocrine tests depends on the choice of tests, the preparation of the patients, the integrity of the specimens, the quality of the measurements, and the validity of the reference data. Close dialogue among the clinicians, the laboratory, and the patients is a key factor for optimal patient care. The characteristics of urine and plasma samples and the advantages and limitations of paired test measurements are presented. The importance of test sequence strategies, provocative or inhibitory procedures, and elimination of drug interferences is illustrated with four cases involving Cushing syndrome, pheochromocytoma, primary aldosteronism, and hypercalcemia. For each of these scenarios, key clinical issues are highlighted, along with discussions of the best test strategies, including which medications are likely to interfere. The importance of targeting laboratory tests to answer well-focused clinical decisions is emphasized. The roles of some time-honored provocative procedures are questioned in light of more sensitive and specific analytic methods. The importance of decision-focused analytical tolerance limits is emphasized by demonstrating the impact of analytic bias on downstream medical resource utilization. User-friendly support systems to facilitate the implementation of test strategies and postanalytic tracking of patient outcomes are presented as essential requirements for quality medical practice.
Drug Monitoring of Antiretroviral Therapy for HIV-1 Infection: Method Validation and Results of a Pilot Study
Moyer, Thomas P. , Temesgen, Zelalem , Enger, Robert, Estes, Lynn L., Charlson, Joel, Oliver, Lawrence K., Wright, Alan J. , Enger, Robert, Charlson, Joel R., Wright, Alan

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 9 | Pages: 1465-1476

10.1093/clinchem/45.9.1465 Get It

Abstract Background: Antiretroviral therapy for HIV-1 infection has become increasingly complex. The availability of new and potent drugs and progress in understanding the pathogenesis of HIV-1 infection have led to the establishment of new treatment paradigms. The varying dosing regimens, associated toxicities, and the potential for drug-drug and food-drug interactions further complicate treatment. This complexity contributes to patient nonadherence. Because clinicians have no tools to monitor adherence or drug-drug interactions and because response requires that therapy exceed the known inhibiting concentration, serum monitoring of antiretroviral therapy may play a role in improving treatment of HIV-1 infection. We report methods to quantify serum concentrations of antiretroviral drugs used to treat HIV-1 infection, precision and interference studies of these methods, and results observed in a pilot evaluation of blood serum concentrations from 12 human subjects. Methods: HPLC offers adequate sensitivity to measure peak or trough serum concentrations of delavirdine, lamivudine, nevirapine, indinavir, nelfinavir, ritonavir, and saquinavir and peak serum concentrations of stavudine, zidovudine, and didanosine with reasonable precision. Results: Peak indinavir serum concentrations in most patients were in the range of 1–10 mg/L, and trough concentrations were in the range of 0.1–0.5 mg/L. Peak stavudine concentrations were in the range of 0.3–1.3 mg/L, and trough concentrations were in the range of 0.1–0.5 mg/L. Peak zidovudine concentrations were in the range of 0.1–1.1 mg/L. Conclusions: Because this was a blood serum concentration-seeking pilot study to evaluate analytic performance, we do not report on the correlation of drug response to blood concentration. However, the concentrations observed in patients are generally consistent with blood concentrations reported from studies of monotherapy.
Method for the Determination of Total Homocysteine in Plasma and Urine by Stable Isotope Dilution and Electrospray Tandem Mass Spectrometry
Magera, Mark J , Lacey, Jean M., Casetta, Bruno, Rinaldo, Piero

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 9 | Pages: 1517-1522

10.1093/clinchem/45.9.1517 Get It

Abstract Background: Total homocysteine (tHcy) has emerged as an important independent risk factor for cardiovascular disease. Analytical methods are needed to accommodate the high testing volumes for tHcy and provide rapid turnaround. Methods: We developed liquid chromatography electrospray tandem mass spectrometry (LC-MS/MS) method based on the analysis of 100 μL of either plasma or urine with homocystine-d8 (2 nmol) added as internal standard. After sample reduction and deproteinization, the analysis was performed in the multiple reaction monitoring mode in which tHcy and Hcy-d4 were detected through the transition from the precursor to the product ion (m/z 136 to m/z 90 and m/z 140 to m/z 94, respectively). The retention time of tHcy and Hcy-d4 was 1.5 min in a 2.5-min analysis. Results: Daily calibrations between 2.5 and 60 μmol/L exhibited consistent linearity and reproducibility. At a plasma concentration of 0.8 μmol/L, the signal-to-noise ratio for tHcy was 17:1. The regression equation for the comparison between our previous HPLC method (y) and the LC-MS/MS method (x) was y = 1.097x − 1.377 (r = 0.975; Sy|x =1.595 μmol/L; n = 367), and for comparison between a fluorescence polarization immunoassay (Abbott IMx; y) and LC-MS/MS (x) was y = 1.039x + 0.025 (r = 0.969; Sy|x =1.146 μmol/L; n = 367). Inter- and intraassay CVs were 2.9–5.9% and 3.6–5.3%, respectively, at mean concentrations of 3.9, 22.7, and 52.8 μmol/L. Mean recovery of tHcy was 94.2% (20 μmol/L) and 97.8% (50 μmol/L). Conclusions: The sensitivity and specificity of tandem mass spectrometry are well suited to perform high-volume analysis of tHcy. Reagents are inexpensive and sample preparation of a batch of 40 specimens is completed in less than 1 h and is amenable to automation.
Defect in Dimethylglycine Dehydrogenase, a New Inborn Error of Metabolism: NMR Spectroscopy Study
Moolenaar, Sytske H., Poggi-Bach, Jo, Engelke, Udo F. H. , Corstiaensen, Jacqueline MB, Jong, Jan GN de, Binzak, Barbara A., Heerschap, Arend , Jong, Jan G.N. de, Vockley, Jerry , Wevers, Ron A.

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 4 | Pages: 459-464

10.1093/clinchem/45.4.459 Get It

AbstractBackground: A38-year-old man presented with a history of fish odor (since age 5) and unusual muscle fatigue with increased serum creatine kinase. Our aim was to identify the metabolic error in this new condition.Methods: We used 1H NMR spectroscopy to study serum and urine from the patient.Results: The concentration of N,N-dimethylglycine (DMG) was increased ∼100-fold in the serum and ∼20-fold in the urine. The presence of DMG as a storage product was confirmed by use of 13C NMR spectroscopy and gas chromatography–mass spectrometry. The high concentration of DMG was caused by a deficiency of the enzyme dimethylglycine dehydrogenase (DMGDH). A homozygous missense mutation was found in the DMGDH gene of the patient.Conclusions: DMGDH deficiency must be added to the differential diagnosis of patients complaining of a fish odor. This deficiency is the first inborn error of metabolism discovered by use of in vitro 1H NMR spectroscopy of body fluids.
A New Gas Chromatography–Mass Spectrometry Method for Simultaneous Determination of Total and Free trans-3′-Hydroxycotinine and Cotinine in the Urine of Subjects Receiving Transdermal Nicotine
Ji, Allena , Lawson, George M., Anderson, Rodger W , Dale, Lowell C., Croghan, Ivana T. , Hurt, R. Douglas

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 1 | Pages: 85-91

10.1093/clinchem/45.1.85 Get It

Abstracttrans-3′-Hydroxycotinine (THOC) has been recognized as the most abundant metabolite of nicotine. In an attempt to assess THOC and cotinine (COT) concentrations during nicotine transdermal therapy, we developed a new quantitative gas chromatography–mass spectrometry (GC–MS) method for simultaneous determination of total and free THOC and COT in human urine. The method utilizes the following: (a) hydrolysis of conjugated THOC and COT by β-glucuronidase; (b) basic extraction of THOC and COT with mixed dichloromethane and n-butyl acetate; (c) derivatization of THOC with bis(trimethylflurosilyl)acetamide; and (d) separation and identification by GC–MS with selective ion monitoring. Lower limits of quantification for the assay were 50 and 20 μg/L for THOC and COT, respectively. The intra- and interassay CVs were 4.4% and 11% for THOC, and 3.9% and 10% for COT at 1000 μg/L. The results from six consecutive 24-h urine collections in 71 subjects administered daily transdermal nicotine doses of 11, 22, and 44 mg showed that, on average, free THOC was 76% of total THOC and free COT was 48% of total COT in all subjects. THOC is the major metabolite of nicotine and constitutes 20% of total nicotine intake at steady state, whereas urinary nicotine and COT excretion were 8% and 17%, respectively. The method is useful for simultaneous determination of free and total THOCand COT and can be used to assess the urinary excretion of these metabolites during transdermal nicotine therapy.
Rapid, nonradioactive screening for mutations in exons 10, 11, and 16 of the RET protooncogene associated with inherited medullary thyroid carcinoma
Siegelman, Mark, Mohabeer, A J, Fahey, Thomas J. , Mayambala, Chris, Jafari, Sepideh , Noll, Walter W., Thibodeau, Stephen N. , Dawson, D. Brian, Tomlinson, Gail Elizabeth , Jafari, Sepideh

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 43 | Issue: 3 | Pages: 453-457

10.1093/clinchem/43.3.453 Get It

Abstract Germline mutations in exons 10, 11, and 16 of the RET protooncogene are associated with the heritable cancer syndromes multiple endocrine neoplasia (MEN) type 2A, familial medullary thyroid carcinoma (FMTC), and MEN type 2B. Nonradioactive mutation analysis with nondenaturing Phastgels® and the Phast System™ was performed on DNA amplified by the polymerase chain reaction from exons 10, 11, and 16 of the RET protooncogene from patients with MEN 2A, MEN 2B, or FMTC. The analysis requires ∼45–90 min for electrophoresis and 35 min for staining. This assay detected 20 of 21 different mutations that represented ∼90% of all known mutations associated with these lesions. A rare silent polymorphism within exon 10 was also detected. This form of mutation analysis provides simple, rapid, and highly sensitive nonradioactive detection of mutations known to be associated with MEN 2A, FMTC, and MEN 2B.
Serum Neuron-Specific Enolase in Patients with Pituitary Adenoma
Heshmati, Hassan , Foubert, L., Turpin, G, Touitou, Yvan , Foubert, Luc, Young, William F. , Bruckert, Éric

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 43 | Issue: 3 | Pages: 540-541

10.1093/clinchem/43.3.540 Get It

Clinical Implications of a Sandwich Enzyme Immunoassay for Big Endothelin-1
Mathew, Verghese, Lerman, Amir

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 43 | Issue: 1 | Pages: 9-10

10.1093/clinchem/43.1.9 Get It