SummaryRecent studies suggest that cyclosporine may be an alternative to colectomy in children with severe ulcerative colitis who fail traditional therapy with bowel rest and high‐dose corticosteroids. We report the clinical course of two such children. Patient I received oral cyclosporine at 15 mg/kg/day for 1 week followed by 8 mg/kg/day for 6 weeks. Clinical remission occurred within 5 days and has been sustained for 24 weeks after azathioprine was substituted for cyclosporine. Patient 2 received oral cyclosporine at 7–8 mg/kg/day for 7 days after which colectomy was performed due to lack of clinical improvement. Blood cyclosporine levels for patient 1 ranged from 95 to 406 ng/ml and for patient 2 from 36 to 65 ng/ml. Sigmoid colonic tissue cyclosporine concentrations for patients 1 and 2 were 10,058 and 3,205 ng/g, respectively. The patient who responded had significantly higher blood and colonic tissue cyclosporine concentrations than the patient who did not respond. Further studies with larger numbers of patients are needed to determine if there is a correlation between blood and colonic tissue cyclosporine concentrations and clinical response.
A New Gas Chromatography–Mass Spectrometry Method for Simultaneous Determination of Total and Free trans-3′-Hydroxycotinine and Cotinine in the Urine of Subjects Receiving Transdermal Nicotine
Abstracttrans-3′-Hydroxycotinine (THOC) has been recognized as the most abundant metabolite of nicotine. In an attempt to assess THOC and cotinine (COT) concentrations during nicotine transdermal therapy, we developed a new quantitative gas chromatography–mass spectrometry (GC–MS) method for simultaneous determination of total and free THOC and COT in human urine. The method utilizes the following: (a) hydrolysis of conjugated THOC and COT by β-glucuronidase; (b) basic extraction of THOC and COT with mixed dichloromethane and n-butyl acetate; (c) derivatization of THOC with bis(trimethylflurosilyl)acetamide; and (d) separation and identification by GC–MS with selective ion monitoring. Lower limits of quantification for the assay were 50 and 20 μg/L for THOC and COT, respectively. The intra- and interassay CVs were 4.4% and 11% for THOC, and 3.9% and 10% for COT at 1000 μg/L. The results from six consecutive 24-h urine collections in 71 subjects administered daily transdermal nicotine doses of 11, 22, and 44 mg showed that, on average, free THOC was 76% of total THOC and free COT was 48% of total COT in all subjects. THOC is the major metabolite of nicotine and constitutes 20% of total nicotine intake at steady state, whereas urinary nicotine and COT excretion were 8% and 17%, respectively. The method is useful for simultaneous determination of free and total THOCand COT and can be used to assess the urinary excretion of these metabolites during transdermal nicotine therapy.
A Solid Phase Extraction Method for Determination of Nicotine in Serum and Urine by Isotope Dilution Gas Chromatography/Mass Spectrometry with Selected Ion Monitoring
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine | February 5, 2014 | Volume: 35 | Issue: 4 | Pages: 522-527
A rapid method for measuring nicotine concentration in serum and urine is described. Deuterated nicotine is used as an internal standard. Nicotine and deuterated nicotine are extracted using a copolymeric-bonded phase silica column. The extract is analysed by gas chromatography coupled with mass spectrometry (GC/MS) operating in selected ion monitoring mode. The method has a lower limit of detection of approximately 2 μg/L and is linear to at least 2000 μg/L. Within-run percentage coefficients of variation (% CV) are < 4 in both assays over a nicotine concentration range of 10–2000 μg/L. Between-run %CV in the serum assay are 5.4, 5.2, 4.8 and 5.9, respectively, at nicotine concentrations of 10, 15, 25, and 50 μg/L. Between-run %CV in the urine assay are 5.9, 4.5, 2.7 and 5.2, respectively, at nicotine concentrations of 100, 250, 500, and 2000 μg/L. The absolute recovery of nicotine is 61±+6% (mean±SD) over the range of 10–250 μg/L. The assay has been used to measure serum nicotine concentrations and 24-h urinary excretion of nicotine to monitor the extent of replacement in subjects receiving transdermal nicotine therapy for smoking cessation.
Enhanced Throughput with Capillary Electrophoresis via Continuous-Sequential Sample Injection