Citations

Clear

53 citation(s) found for "Tan, Min C".

Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Tan, Min Choon , Karikalan, Suganya Arunachalam , Deshmukh, Abhishek , Srivathsan, Komandoor , Scott, Luis R. , McLeod, Christopher J. , Asirvatham, Samuel J. , Noseworthy, Peter A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Munger, Thomas M. , Lee, Justin Z. , Karikalan, Suganya , Deshmukh, Abhishek J , Srivathsan, Komandoor , Scott, Luis R , McLeod, Christopher J , Asirvatham, Samuel J , Noseworthy, Peter A , Deshmukh, Abhishek J , Tan, Min C , Rattanawong, Pattara

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | April 21, 2023 | Volume: 16 | Issue: 5 | Pages: No page available

10.1161/circep.122.011365 | PMID 37082954 Get It

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). Conclusions: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.
Chronic kidney disease is associated with increased all‐cause mortality in transvenous lead extraction: A systematic review and meta‐analysis
Tan, Min Choon , Talaei, Fahimeh , Trongtorsak, Angkawipa , Lee, Justin Z. , Rattanawong, Pattara , Tan, Min C , Rattanawong, Pattara

Mayo Clinic

Pacing and Clinical Electrophysiology | November 28, 2022 | Volume: 46 | Issue: 1 | Pages: 66-72

10.1111/pace.14631 | PMID 36441922 Get It

AbstractBackgroundThe impact of chronic kidney disease (CKD) or end‐stage renal disease (ESRD) on patients receiving transvenous lead extraction (TLE) is not well‐established. We performed a systematic review and meta‐analysis to explore the association between CKD and all‐cause mortality in TLE.MethodsWe searched the databases of PubMed and EMBASE from inception to April 2022. Included studies were published TLE studies that compared the risk of mortality in CKD patients compared to control patients. Data from each study were combined using the random‐effects model.ResultsEight studies (5,013 patients) were included. Compared with controls, CKD patients had a significantly higher risk of overall all‐cause mortality (hazard ratio [HR] = 2.14, 95% confidence interval [CI]: 1.65–2.77, I2 = 51.1%, p < .001). The risk of overall all‐cause mortality increased with the severity of CKD for nonspecific CKD (HR = 2.01, 95% CI: 1.49–2.69, I2 = 53.4, p < .001) and ESRD (HR = 2.79, 95% CI: 1.85–4.23, I2 = 0%, p < .001). The risk of all‐cause mortality in CKD is double at follow‐up ≤1 year (HR = 1.99, 95% CI: 1.29–3.09, I2 = 50.9%, p = .002) and higher at follow‐up >1 year (HR = 2.36, 95% CI: 1.63–3.42, I2 = 59.7%, p < .001).ConclusionsOur meta‐analysis demonstrates a significantly increased risk of overall all‐cause mortality in patients with CKD who underwent TLE compared to controls.
Complications of Endobronchial Valve Placement for Bronchoscopic Lung Volume Reduction
Swanson, Karen L., Lee, Justin Z. , Tan, Min Choon , Cartin‐Ceba, Rodrigo , Sakata, Kenneth K. , Maldonado, Fabien , Tan, Min C , Low, See‐Wei

Mayo Clinic

Journal of Bronchology & Interventional Pulmonology | June 14, 2022 | Volume: 29 | Issue: 3 | Pages: 206-212

10.1097/lbr.0000000000000859 | PMID 35698284 Get It

Background: Patients with advanced emphysema experience breathlessness due to impaired respiratory mechanics and diaphragm dysfunction. Bronchoscopic lung volume reduction (BLVR) is a minimally invasive bronchoscopic procedure done to reduce hyperinflation and air trapping, promoting atelectasis in the targeted lobe and allowing improved respiratory mechanics. Real-world data on safety and complications outside of clinical trials of BLVR are limited. Methods: We queried the US Food and Drug Administrations (FDA) Manufacturers and User Device Experience database from May 2019 to June 2020 for reports involving BLVR with endobronchial valve (EBV) placement. Events were reviewed for data analysis. Results: We identified 124 cases of complications during BLVR with EBV implantation. The most-reported complication was pneumothorax (110/124, 89%), all of which required chest tube placement. A total of 54 of these cases (54/110, 49%) were complicated by persistent air leak requiring additional interventions. Repeat bronchoscopy was needed to remove the valves in 28 patients, 12 were discharged with a Heimlich valve, and 10 had an additional pleural catheter placed. The other complications of BLVR with EBV placement included respiratory failure (6/124, 5%), pneumonia (4/124, 3%), hemoptysis (2/124, 1.6%), valve migration (1/124, 1%), and pleural effusion (1/124, 1%). A total of 14 deaths were reported during that year. Conclusion: Pneumothorax is the most-reported complication for BLVR with EBV placement, and in 65% of cases, pneumothorax is managed without removing valves. Importantly, 14 deaths were reported during that timeframe. Further studies are needed to estimate the true magnitude of the complications associated with BLVR.