Endovascular Treatment of Aneurysms Using Flow-Diversion Embolization: 2-Dimensional Operative Video
Cavalcanti, Daniel D. , Nelson, Peter Kim , Raz, Eytan , Shapiro, Maksim , Nossek, Erez , Tanweer, Omar , Riina, Howard A. , Bain, Mark, Bendock, Bernard, Boulos, Alan S. , Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Nelson, L Hopkins, Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levitt, Michael , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Raymond, Turner, Welch, Babu G. , Schirmer, Clemens M , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levitt, Michael, Lopes, Demetrius K. , Mocco, J , Rodriguez, Rafael, Siddiqui, Adnan H. , Thomas, Ajith J , White, Jonathan Samuel

Mayo Clinic

Operative Neurosurgery | January 31, 2021 | Volume: 20 | Issue: 4 | Pages: E284-E285

10.1093/ons/opaa462 | PMID 33517417 Get It

Abstract Initially developed for large and giant wide-necked aneurysms of the internal carotid artery, flow diverter devices are now used in almost every location safely and with effectiveness. 1-5 This video demonstrates a unique case of a giant aneurysm of the right petrous internal carotid artery in a 20-yr-old patient. This is an extremely rare location, and most of patients are asymptomatic. 3-6 Signs of compression of the seventh and eight cranial nerves can be present and even Horner syndrome and lower cranial nerves neuropathies. Nevertheless, rupture can lead to epistaxis and otorrhagia, and ultimately to hemorrhagic shock. The patient in the current report was otherwise healthy but presented with lightheadedness and dizziness for 10 d. The patient consented to the procedure. There was no history of major trauma or head and neck infection. A transradial endovascular flow diversion embolization of a giant aneurysm of the petrous internal carotid artery is herein demonstrated in a stepwise manner. A triaxial system was used to deploy 3 overlapping devices. Concepts of J-wire technique, multiple coverage, 1 and the so-called weld technique are emphasized. The role of adjunctive coiling and main reasons for failure are also discussed. 7,8 Brief cases of flow diversion embolization of aneurysms of different morphologies at different locations are used to highlight the importance of assessing vessel wall apposition and follow-up imaging.
Transarterial Embolization of a Transverse Sinus Dural Arteriovenous Fistula: 2-Dimensional Operative Video
Gomez‐Paz, Santiago , Akamatsu, Yosuke , Salem, Mohamed M. , Ogilvy, Christopher S. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levitt, Michael R. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Ringer, Andrew J. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Levitt, Michael R , Gomez-Paz, Santiago , Schirmer, Clemens M , Ogilvy, Christopher S , Moore, Justin M. , Thomas, Ajith J , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , White, Jonathan A.

Mayo Clinic

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E41-E42

10.1093/ons/opaa370 | PMID 33316817 Get It

Abstract A 40-yr-old male with no significant past medical history presented with sudden onset right-sided retro-orbital headache associated with vision loss after a session of strenuous exercise. Initial assessment with noncontrast head computed tomography at the local emergency department revealed a right sided occipital intracranial hemorrhage (ICH). On arrival the patient ad a left quadrantopsia with Glasgow Coma Scale of 15 and an ICH score of 0. A computed tomographic angiography showed a high density 6 × 9 mm vascular lesion associated with 2 tortuous vessels. Cerebral angiography revealed a right sided dural arteriovenous fistula, Cognard Type IV, with arterial feeders arising from dural branches of the right vertebral artery, the posterior division of the right middle meningeal artery and meningeal branches distal to the neuromeningeal trunk of the left ascending pharyngeal artery. 1 Four days after the ICH event the patient was treated with endovascular Onyx embolization of the fistula, through a transradial approach. Immediate angiographic assessment showed complete obliteration of the dAVF. The patient was discharged home and recovered his visual field deficit over 3 mo. The following operative video includes a discussion of the endovascular technique and treatment nuances associated with the transarterial management of a dural arteriovenous fistula. Patient consent was given prior to the procedure and consent and approval for this operative video was waived due to the retrospective nature of this manuscript and the anonymized video material.
Distal Access to Wide-Necked Aneurysms—‘Around the World’ Technique: 2-Dimensional Operative Video
Ringer, Andrew J. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levitt, Michael R. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Ogilvy, Christopher S. , Levitt, Michael R , Schirmer, Clemens M , Ogilvy, Christopher S , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Mayo Clinic

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E39-E40

10.1093/ons/opaa369 | PMID 33316816 Get It

Abstract Wide-necked aneurysms often pose challenges for distal access to the distal vasculature. This 64-yr-old woman without neurological deficits presented with atypical headaches of gradual onset. MRI revealed a large, symptomatic, unruptured carotid terminus aneurysm incorporating the origin of both the middle (MCA) and anterior cerebral arteries (ACA). Its wide neck created significant risks to coil prolapse and parent vessel compromise, risking stroke. With other options of higher risks, we recommended an around-the-world technique. Standard transfemoral access was used to the right internal carotid artery (ICA) with a 6F-Shuttle sheath and intracranial carotid with a 6F-Sofia distal access catheter. With dual-microcatheter access, 1 catheter was placed in the aneurysm dome, a second in the MCA for stent placement. Advancing the wire around the aneurysm first formed a loop from the lateral to medial wall for access to the MCA. The microcatheter was then advanced around the wire into the MCA, keeping the loop within the dome. With the loop's distal tip anchored, the distal end of the stent was deployed and anchored into the MCA. Both pitfalls (ie, lack of sufficient distal access, collapse of stent device during deployment) were resolved using a balloon catheter. With the balloon positioned and inflated as the anchor, the wire and catheter were pulled together. The loop in the aneurysm's dome straightened out across the neck, the stent was advanced into the MCA, and coiling proceeded. A large neck remnant had partially closed on 6-mo follow-up angiogram. Patient consented to undergo the procedure. Illustrations in video published/printed with permission from Mayfield Clinic.
Stent-Assisted Coiling of a Sidewall Aneurysm of the Distal Middle Cerebral Artery: 2-Dimensional Operative Video
Cavalcanti, Daniel D. , Delavari, Nader , Riina, Howard A. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levy, Elad, Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Schirmer, Clemens M , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levitt, Michael R. , Levy, E, Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Ringer, Andrew J. , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Mayo Clinic

Operative Neurosurgery | December 14, 2020 | Volume: 20 | Issue: 1 | Pages: E37-E38

10.1093/ons/opaa332 | PMID 33316814 Get It

Abstract Sidewall aneurysm treatment often requires complex management strategies. These can include advanced clipping techniques or stent-assisted coiling techniques. Endovascular coiling alone has been associated with high recurrence rates and is often not feasible. 1-4 Flow-diversion embolization has recently become a standard of care for many aneurysms, demonstrating high occlusion rates. 4,5 However, the third generation of coil-assist stents can be delivered with 0.0165” microcatheters, being an ideal adjunct to manage this group of aneurysms in more distal locations. In this video, a 16-yr-old teenager with Parry-Romberg syndrome and congenital adrenal hyperplasia had an incidental finding of a 6.5-mm sidewall aneurysm arising off the angular branch of the left middle cerebral artery, found during the work-up of complex partial seizures. The patient consented to the procedure. Due to his young age and aneurysm size, a decision was made to treat the aneurysm through an endovascular approach. Under general anesthesia, a transfemoral approach was carried out using a 6-French short sheath. A 6-French guiding catheter was left in the distal cervical left internal carotid artery; a 0.0165” microcatheter was used to first deploy a 3.0 × 15 mm Neuroform Atlas stent, completely covering the length of the aneurysm. Then, the stent was traversed with the microcatheter to coil the aneurysm. Follow-up cerebral angiogram confirmed complete occlusion of the aneurysm.
Comparison of PED and FRED flow diverters for posterior circulation aneurysms: a propensity score matched cohort study
Enríquez-Marulanda, Alejandro , Xiang, Sissi, Zhang, Hongqi , Waqas, Muhammad , Tutino, Vincent M. , Siddiqui, Adnan H. , Ogilvy, Christopher S. , Ulfert, Christian , Möhlenbruch, Markus , Renieri, Leonardo , Limbucci, Nicola , Burkhardt, Jan‐Karl , Kan, Peter , Rinaldo, Lorenzo , Brinjikji, Waleed , Spears, Julian , Broussalis, Erasmia , Koçer, Naci , Sonnberger, Michael , Engelhorn, Tobias , Ghuman, Mandeep S. , Salehani, Arsalaan , Harrigan, Mark R. , Radovanovic, Ivan , Chen, Karen , Aziz‐Sultan, Mohammad Ali , Ghorbani, Mohammad , Schirmer, Clemens M. , Goren, Oded , Dalal, Shamsher , Koch, Matthew J. , Stapleton, Christopher J. , Patel, Aman B. , Finkenzeller, Thomas , Holtmannspötter, Markus, Buhk, Jan Hendrik, Foreman, Paul M. , Cress, Marshall C. , Hirschl, Robert , Reith, W. , Janssen, Hendrik , Marotta, Thomas R. , Dmytriw, Adam A. , Waqas, Muhammad , Siddiqui, Adnan H , Levy, Elad I , Thomas, Ajith J , Renieri, Leonardo , Parra-Fariñas, Carmen , Rinaldo, Lorenzo , Brinjikji, Waleed , Müller-Thies-Broussalis, Erasmia , Killer-Oberpfalzer, Monika , Koch, Matthew J , Simgen, Andreas , Janssen, Hendrik , Marotta, Thomas R , Dmytriw, Adam A , Tutino, Vincent M , Schirmer, Clemens M , Ulfert, Christian , Limbucci, Nicola , Ogilvy, Christopher S , Griessenauer, Christoph J. , Hong, Tao , Taussky, Philipp , Grandhi, Ramesh , Levy, Elad I. , Lanzino, Giuseppe , Işlak, Civan , Yang, Victor X. D. , Mendes Pereira, Vitor , Krings, Timo , Matouk, Charles

Mayo Clinic

Journal of NeuroInterventional Surgery | July 1, 2020 | Volume: 13 | Issue: 2 | Pages: 153-158

10.1136/neurintsurg-2020-016055 | PMID 32611622 Get It

Abstract Background Flow diversion is a common endovascular treatment for cerebral aneurysms, but studies comparing different types of flow diverters are scarce. Objective To perform a propensity score matched cohort study comparing the Pipeline Embolization Device (PED) and Flow Redirection Intraluminal Device (FRED) for posterior circulation aneurysms. Methods Consecutive aneurysms of the posterior circulation treated at 25 neurovascular centers with either PED or FRED were collected. Propensity score matching was used to control for age, duration of follow-up imaging, adjunctive coiling, and aneurysm location, size, and morphology; previously ruptured aneurysms were excluded. The two devices were compared for the following outcomes: procedural complications, aneurysm occlusion, and functional outcome. Results A total of 375 aneurysms of the posterior circulation were treated in 369 patients. The PED was used in 285 (77.2%) and FRED in 84 (22.8%) procedures. Aneurysms treated with the PED were more commonly fusiform and larger than those treated with FRED. To account for these important differences, propensity score matching was performed resulting in 33 PED and FRED unruptured aneurysm pairs. No differences were found in occlusion status and neurologic thromboembolic or hemorrhagic complications between the two devices. The proportion of patients with favorable functional outcome was higher with FRED (100% vs 87.9%, p=0.04). Conclusion Comparative analysis of PED and FRED for the treatment of unruptured posterior circulation aneurysms did not identify significant differences in aneurysm occlusion or neurologic complications. Variations in functional outcomes warrant additional investigations.
Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results
Kallmes, David F. , Nelson, Peter Kim , Siddiqui, Adnan H. , Szikora, István , Zaidat, Osama O. , Colby, Geoffrey P. , Schirmer, Clemens M. , Hellinger, Frank R, Given, Curtis A., Tóth, Gábor , Priest, Ryan , Kan, Peter , Frei, Don , Aagaard‐Kienitz, Beverly , Díaz, Orlando , Malek, Adel M. , Cawley, C. Michael , Puri, Ajit S , Zaidat, Osama O , Colby, Geoffrey P , Mokin, Maxim , Taussky, Philipp , Toth, Gabor , Fraser, Justin F , Fiorella, David , Siddiqui, Adnan H , Szikora, Istvan , Schirmer, Clemens M , Hanel, Ricardó A. , Lopes, Demetrius K. , Jabbour, Pascal , Mendes Pereira, Vitor , Bettegowda, Chetan , Krings, Timo , Chen, Michael , Fiorella, David

Mayo Clinic

Journal of NeuroInterventional Surgery | July 15, 2019 | Volume: 12 | Issue: 1 | Pages: 62-66

10.1136/neurintsurg-2019-015091 | PMID 31308197 Get It

Background Preliminary clinical studies on the safety and efficacy of the pipeline embolization device (PED) for the treatment of small/medium aneurysms have demonstrated high occlusion rates with low complications. Objective To evaluate the safety and effectiveness of the PED for treatment of wide necked small and medium intracranial aneurysms. Methods PREMIER is a prospective, multicenter, single arm trial. Patients were treated with the PED for unruptured wide necked aneurysms, measuring ≤12 mm along the internal carotid artery or vertebral artery, between July 2014 and November 2015. At 1 year post-procedure, the primary effectiveness endpoint was complete occlusion (Raymond grade 1) without major parent vessel stenosis (≤50%) or retreatment, and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurologic death. Results A total of 141 patients were treated with PEDs (mean age 54.6±11.3 years, 87.9% (124/141) women). Mean aneurysm size was 5.0±1.92 mm, and 84.4% (119/141) measured <7 mm. PED placement was successful in 99.3% (140/141) of patients. Mean number of PEDs implanted per patient was 1.1±0.26; a single PED was used in 92.9% (131/141) of patients. At 1 year, 97.9% (138/141) of patients underwent follow-up angiography with 76.8% (106/138) of patients having met the study’s primary effectiveness endpoint. The combined major morbidity and mortality rate was 2.1% (3/140). Conclusions Treatment of wide necked small/medium aneurysms with the PED results in high rates of complete occlusion without significant parent vessel stenosis and low rates of permanent neurologic complications. Trial registration NCT02186561 .
Transvenous embolization of thalamic arteriovenous malformation under transient cardiac standstill
Rangel-Castilla, Leonardo , Shallwani, Hussain , Siddiqui, Adnan H. , Siddiqui, Adnan H , Rangel-Castilla, Leonardo

Mayo Clinic

Neurosurgical Focus | February 26, 2019 | Volume: 46 | Issue: Suppl_1 | Pages: V10

10.3171/2019.1.focusvid.18416 | PMID 30611173 Get It

Transvenous embolization (TE) has been increasingly applied for arteriovenous malformation (AVM) treatment. Transient cardiac standstill (TCS) has been described in cerebrovascular surgery but is uncommon for endovascular embolization. The authors present a patient with a ruptured thalamic AVM in whom both techniques were applied simultaneously. Surgery was considered, but the patient refused. Transarterial embolization was performed with an incomplete result. The deep-seated draining vein provided sole access to the AVM. A microcatheter was advanced into the draining vein. Under TCS, achieved with rapid ventricular pacing, complete AVM embolization was obtained. One-year magnetic resonance imaging and cerebral angiography demonstrated no residual AVM. The video can be found here: https://youtu.be/CAzb9md_xBU .